Trust Cook s line of ports to meet your vascular access needs.
Vascular access sets The convenience of power injection with the comfort of Vital-Port. Features: Maximum flow rate: 5 ml/sec Maximum pressure setting: 325 psi Maximum viscosity of media: 11.8 cp Used only with infusion needles that are approved for power injection MR conditional status
Vital-Port Vascular Access System (power injectable) These standard size, single-chamber titanium Vital-Port models are approved for power injection. Global Product Order Catheter ID Catheter OD Introducer Silicone Catheter Attached with Peel-Away Introducer Sets G26434 IP-S7010 1.4 7.5 8.0 5 G26438 IP-S9010 1.6 9.5 10.0 5 Silicone Catheter Detached with Peel-Away Introducer Sets G26436 IP-S7110 1.4 7.5 8.0 5 G26440 IP-S9110 1.6 9.5 10.0 5 Silicone Catheter Without Introducer Set G20254 IP-7110 1.4 7.5 5 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Only use infusion sets approved for power injection with power injectable Vital-Port models. MR conditional, tested up to 3T. Visit cookmedical.com for more information. Flow Rate ml/sec
Single-chamber titanium High-strength titanium port is designed for patient comfort and ease of access. STANDARD TITANIUM SINGLE-CHAMBER SYSTEMS Weight: 17.8 g Volume:.62 ml 12.7 30.0 Global Product Order Catheter ID Catheter OD Introducer Silicone Catheter Detached with Peel-Away Introducer Set G26432 IP-S6110 1.0 6.5 7.0 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. 12.7 PETITE TITANIUM SINGLE-CHAMBER SYSTEMS Weight: 9.0 g Volume:.35 ml 10.2 24.1 9.7 Global Product Order Catheter ID Catheter OD Introducer Silicone Catheter Attached with Peel-Away Introducer Set G26431 IP-S6013 1.0 6.5 7.0 Silicone Catheter Detached with Peel-Away Introducer Set G26433 IP-S6113 1.0 6.5 7.0 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Single-chamber titanium set includes: Standard or petite port 22 gage noncoring needle 18 gage access needle 50 cm wire guide 20 cm metal tunneler Syringe Peel-Away sheath
Mini titanium set One of the lowest profile ports available for ease of peripheral and other placement. 4 6 Mini titanium set 1 2 Low profile mini port 22 gage noncoring needle 1 3 4 5 6 7 21 gage echogenic access needle* Catheter and obturator with stopcock** 50 cm wire guide Syringe Peel-Away sheath Not shown: 20 cm metal tunneler 7 2 3 5 MINI TITANIUM SINGLE-CHAMBER SYSTEMS Weight: 5.0 g Volume:.15 ml 6.6 19.0 7.2 Global Product Order Catheter ID Catheter OD Introducer Silicone Catheter Attached G26469 IP-S5016.9 5.0 6.0 Silicone Catheter Detached G26470 IP-S5116.9 5.0 6.0 Silicone Catheter Detached with Obturator and Micropuncture Introducer Set G26489 IP-S5116W-MPIS-NT.9 5.0 5.5 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. *IP-S5016 and IP-S5116 include a 19 gage noncoring needle. ** Included only in IP-S5116W-MPIS-NT. MR conditional, tested up to 3T. Visit cookmedical.com for more information.
References Lenhart M, Schätzler S, Manke C, et al. Radiological placement of peripheral central venous access ports at the forearm: technical results and long term outcome in 391 patients. (This article is written in German.) Rofo. 2010;182(1):20-28. Wildgruber M, Borgmeyer S, Haller B, et al. Short-term and long-term outcome of radiological-guided insertion of central venous access port devices implanted at the forearm: a retrospective monocenter analysis in 1704 patients. Eur Radiol. 2015;25(3):606-616. Wildgruber M, Lueg C, Borgmeyer S, et al. Polyurethane versus silicone catheters for central venous port devices implanted at the forearm. Eur J Cancer. 2016;59:113-124. Kawamura J, Nagayama S, Nomura A, et al. Long-term outcomes of peripheral arm ports implanted in patients with colorectal cancer. Int J Clin Oncol. 2008;13(4):349-354. Burbridge B, Stoneham G, Szkup P, et al. Catheter fracture and embolization associated with arm implantation of the Cook Vital-Port. Can Assoc Radiol J. 2013;64(3):269-273. Burbridge B, Krieger E, Stoneham G. Arm placement of the Cook titanium petite Vital-Port: results of a radiologic placement in 125 patients with cancer. Can Assoc Radiol J. 2000;51(3):163-169.
Notes
MEDICAL COOK 12/2016 IR-D30148-EN-F