IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults.

Similar documents
Surgical technique. IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults.

Technique Guide. IMF Screw Set. For intermaxillary fixation.

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

LCP Metaphyseal Plates. For extra-articular fractures.

Distal Radius Plate 2.4/2.7 dorsal and volar

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Button Plate. Reinforcement for transosseous fixations.

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

MatrixNEURO. The next generation cranial plating system.

Compact 2.0 LOCK Mandible. The locking system for the mandible.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

3.0/3.5/4.0/4.5/6.5/7.0/7.3. Cannulated Screws. Surgical Technique

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Orthodontic Bone Anchor (OBA) System

Wrist Fusion Instrument and Implant Set.

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

LCP Superior Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Mandible External Fixator II

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

LCP DISTAL TIBIA PLATE

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

Compact Midface. The systematic solution for craniomaxillofacial indications and displacement osteotomies.

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Cannulated Pediatric Osteotomy System (CAPOS). A single system of osteotomy blade plates and cannulated instrumentation.

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

Mini External Fixator.

Internal Midface Distractor.

VA LOCKING CALCANEAL PLATES 2.7

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

ANGLED BLADE PLATES FOR ADULTS

LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Femoral Neck System. Surgical Technique

MATRIX PLATFORM FEATURES DESIGNED TO COMPLEMENT AO FIXATION PRINCIPLES

Condylar Head Add-on System. Adjustable system for condylar head reconstruction.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Surgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

Technique Guide. Orthodontic Bone Anchor (OBA) System. Skeletal implants for the orthodontic movement of the teeth.

MatrixMIDFACE Plate and Screw System. Surgical Technique

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

VA-LCP Olecranon Plates 2.7/3.5. The fracture-specific low-profile fixation system with variable angle locking technology.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

Clavicle Hook Locking Plate

VECTRA-T SURGICAL TECHNIQUE. The Translational Anterior Cervical Palate System. This publication is not intended for distribution in the USA.

Cannulated Pediatric Osteotomy System (CAPOS). A single system of osteotomy blade plates and cannulated instrumentation.

Distal Ulnar Locking Plate

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Midfoot Fusion Bolt 6.5 mm. Intramedullary fixation of the medial column of the foot.

CSLP-Cervical Spine Locking Plate

Rotation Correction Plates 1.5 and 2.0. Reposition plates for fractures and osteotomies at the metacarpals and phalanges.

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

MatrixNEURO. The next generation cranial plating system.

LCP Ulna Osteotomy System 2.7. Low profile angular stable fixation for ulna shortening osteotomies.

ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

Cannulated Pediatric Osteotomy System (CAPOS). A single system of osteotomy blade plates and cannulated instrumentation.

VA-LCP Ankle Trauma System 2.7/3.5. Our most comprehensive ankle plating system.

Humerus Block. Discontinued December 2016 DSEM/TRM/0115/0296(1) Surgical Technique. This publication is not intended for distribution in the USA.

Collinear Reduction Clamp

WINSTA-C. Clavicle Plating System

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

LCP Periarticular Proximal Humerus Plate 3.5. The anatomic fixation system with anterolateral shaft placement.

LCP Proximal Tibial Plate 4.5/5.0 with Periarticular Aiming Arm Instruments

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

VA-LCP Ankle Trauma System 2.7/3.5. Our most comprehensive ankle plating system.

Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Procedures.

ARCH Laminoplasty System

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

matrixwave tm mmf expand your possibilities A novel system that expands and compresses to achieve maxillomandibular fixation

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

LCP DHHS. The Dynamic Helical Hip System for Proximal Femur Fractures.

VA LCP MEDIAL COLUMN FUSION PLATES 3.5

TSLP Thoracolumbar Spine Locking Plate

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Olecranon Locking Plate II

TomoFix Medial Distal Femur (MDF). For closed-wedge varus femoral osteotomies.

VA-LCP Distal Humerus Plates 2.7/3.5. The low-profile fixation system with variable angle locking technology.

Periarticular Aiming Arm Instruments for LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Aiming Arm Instrument System (large).

orthodontic Bone anchor (oba) SYStem

SynCage-C short. Surgical Technique. This publication is not intended for distribution in the USA.

3.5 mm LCP Clavicle Hook Plates

TELEFIX SURGICAL TECHNIQUE. Implant system for the anterior stabilization of the thoracolumbar spine

USS II ILIO-SACRAL Modular System for Stable Fixation in the Sacrum and Illium

LCP Distal Humerus Plates

Low Bend Distal Tibia Plates

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

The Versatile Polyaxial Solution for the Universal Spine Systems. USS II Polyaxial. Surgical Technique

LCP Pediatric Condylar Plate 90, 3.5 and 5.0. For distal femur osteotomies.

2.0 mm Mandible Locking Plate System

Transcription:

IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

Table of Contents Features 2 Intended Use, Indications and Contraindications 3 MRI Information 4 Surgical Technique 5 Instruments and Implants 9 General Adverse Events As with all major surgical procedures, risks, side effects and adverse events can occur. While many possible reactions may occur, some of the most common include: Problems resulting from anesthesia and patient positioning (e.g. nausea, vomiting, neurological impairments, etc.), thrombosis, embolism, infection or injury of other critical structures including blood vessels, excessive bleeding, damage to soft tissues incl. swelling, abnormal scar formation, functional impairment of the musculoskeletal system, pain, discomfort or abnormal sensation due to the presence of the device, allergy or hyperreactions, side effects associated with hardware prominence, loosening, bending, or breakage of the device, mal-union, non-union or delayed union which may lead to breakage of the implant, reoperation. Device Specific Adverse Events Device specific adverse events include but are not limited to: Intraoperative Screw breakage, Screw Loosening/pull out, Explantation, Pain, Hematoma, Infection. Warnings These devices can break during use (when subjected to excessive forces or outside the recommended surgical technique). While the surgeon must make the final decision on removal of the broken part based on associated risk in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. Medical devices containing stainless steel may elicit an allergic reaction in patients with hypersensitivity to nickel. Image intensifier control Warning This description is not sufficient for immediate application of the instrument set. Instruction by a surgeon experienced in handling these instruments is highly recommended. Processing / reprocessing of the device Detailed instructions for processing implants and reprocessing reusable devices, instrument trays and cases are described in the DePuy Synthes brochure Important Information. Assembly and disassembly instructions of instruments Dismantling multipart instruments can be downloaded from http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance IMF Screw Set Surgical Technique DePuy Synthes 1

Features 316L stainless steel for maximum strength Self-drilling screws for one-step insertion Groove under screw head secures wires or elastics Cruciform screw head fits with existing Synthes instrumen tation Two cross holes in the screw head align with the cruciform head slots, simplifying wire passage 2 DePuy Synthes IMF Screw Set Surgical Technique

Intended Use, Indications and Contraindications Intended use Temporary, perioperative stabilization of the occlusion in adults. Indications Simple nondisplaced mandibular and maxillary fractures Orthognatic procedures For temporary use during bone healing Contraindications Severely comminuted and/or displaced fractures Unstable, segmented maxillary or mandibular arches Combined maxillary and mandibular fractures Paediatric IMF Screw Set Surgical Technique DePuy Synthes 3

MRI Information Torque, Displacement and Image Artifacts according to ASTM F2213-06, ASTM F2052-06e1 and ASTM F2119-07 Non-clinical testing of a worst case scenario in a 3 T MRI system did not reveal any relevant torque or displacement of the construct for an experimentally measured local spatial gradient of the magnetic field of 5.4 T/m. The largest image artifact extended approximately 31 mm from the construct when scanned using the Gradient Echo (GE). Testing was conducted on a 3 T MRI system. Radio Frequency (RF) induced heating according to ASTM F2182-11a Non-clinical electromagnetic and thermal simulations of a worst case scenario lead to temperature rises of 13.7 C (1.5 T) and 6.5 C (3 T) under MRI Conditions using RF Coils (whole body averaged specific absorption rate [SAR] of 2 W/kg for 15 minutes). Precautions: The above mentioned test relies on nonclinical testing. The actual temperature rise in the patient will depend on a variety of factors beyond the SAR and time of RF application. Thus, it is recommended to pay particular attention to the following points: It is recommended to thoroughly monitor patients undergoing MR scanning for perceived temperature and/or pain sensations. Patients with impaired thermo regulation or temperature sensation should be excluded from MR scanning procedures. Generally it is recommended to use an MRI system with low field strength in the presence of conductive implants. The employed specific absorption rate (SAR) should be reduced as far as possible. Using the ventilation system may further contribute to reduce temperature increase in the body. 4 DePuy Synthes IMF Screw Set Surgical Technique

Surgical Technique The following surgical technique assumes that the first screw is placed in the maxilla. However, screw placement, num ber of screws, and order of insertion are dependent on the fracture type, location and the surgeon s preference. The screws must be positioned superior to the maxillary tooth roots and inferior to the mandibular tooth roots and be inserted either medial or lateral to the long axis of the canine roots. The advantages of the lateral approach include increased lateral stability and greater control over posterior open bite. For wiring recommendations, refer to figures 11 and 12, page 7. 1 Determine number and position of screws Determine the number and the position of the IMF screws to be inserted, based on the fracture type and location (figure 1). Fig. 1 Medial to canine root C Lateral to canine roots 2 Locate maxillary tooth roots Locate and identify the maxillary tooth roots, paying particular attention to the canine roots which are the longest of the tooth roots. It is important to avoid the existing dentition as well as infraorbital and mental nerves. A helpful guide to estimating the length of the dentition from radiographs can be found in figure 2. 20.4 21.6 24.6 26.8 26.4 32.4 32.4 28.2 28.2 25.8 27.0 25.8 24.021.6 Precautions: Supernumerary, unerupted and developing teeth may be present and should be confirmed or refuted with ap pro priate x-rays. The maxillary screws should be placed 5 mm superior to the tooth roots. Special care must be employed to identify and avoid canine roots and the dental nerve. Fig. 2 Average tooth lengths (mm) including a 20 % magnification associated with the radiograph. Actual lengths modified from RC Wheeler (1974) Dental Anatomy, Physiology and Occlusion. WB Saunders Co., 20, Philadelphia. IMF Screw Set Surgical Technique DePuy Synthes 5

Surgical Technique 3 Insert screw into maxilla Pick up an IMF Screw (8 mm [201.928] or 12 mm [201.932]) using the 2.4 mm cruciform Screwdriver with Holding Sleeve (313.940). Insert the screw into the maxilla (figure 3) and advance it making sure that the screw head does not compress the gingiva. The cruciform slots of the screw head can be used to orient the cross holes relative to the occlusal plane (figure 4). Fig. 3 Precaution: In dense cortical bone, it may be necessary to predrill with a B 1.5 mm drill bit. Since the IMF screws are self-drilling it may not always be necessary to incise and elevate the gingiva. If making an initial incision, an electrocautery device, which helps to control bleeding, may be used rather than a scalpel. This may ensure a smoother insertion. Fig. 4 4 Insert screw into mandible Before inserting the mandibular screw, identify the important anatomic structures. Again, special attention should be paid to the canine roots and the mental nerve (figure 2). Insert the second screw into the mandible 5 mm inferior and medial or lateral to the canine root (figure 5). If placing these screws inferior and lateral to the canine root in the mandible, greater care must be employed to identify and avoid the mental nerve. Fig. 5 6 DePuy Synthes IMF Screw Set Surgical Technique

5 Insert additional screws Repeat the procedure by inserting at least two additional screws on the contralateral side, one in the maxilla and one in the mandible following the previously outlined procedure (figure 6). Fig. 6 6 Insert wire Insert a wire through the cross holes of the maxillary and opposing mandibular screws (figure 7). The wire may also be wrapped around the screw head grooves rather than inserting it through the cross holes. Fig. 7 7 Establish occlusion Before tightening the wires, the occlusion should be established. Bring the maxillary and mandibular dentition into occlusion, making sure that each condyle is in its proper position within the glenoid fossa. IMF Screw Set Surgical Technique DePuy Synthes 7

Surgical Technique 8 Tighten wires Clamp the free ends of the wires into the Wire Twister (398.906). Pull the wires taut to hold the jaws in occlusion and then twist the wires to tension (figure 8). Cut the wires with the Wire-Cutting Scissors (398.909) and bend the cut wire end under to prevent soft tissue irritation (figures 9 and 10). In order to consolidate the segments it is important to secure the wire in an X-pattern in addition to the vertical pattern that provides maxillomandibular stabilisation and reduces lateral excursion (figures 11 and 12). Fig. 8 Precaution: Due to the tension placed on the wires, there is a poten tial for loosening of the wire or the screw if left in postoperatively. The wire and screw should be carefully monitored for this condition during postsurgical evaluations and tightened as necessary. Fig. 9 Fig. 10 Fig. 11 Fig. 12 9 Check stability Check to ensure that no posterior open bite is produced during tensioning of the wires. The placement of additional IMF screws, Ernst ligatures or Ivy loops on the posterior dentition my be used to prevent or correct this condition (figure 13). Precaution: Overtightening of the wires could lead to rotation of the segments and interference with the reduction. Verify that the fracture is adequately reduced at the inferior border. Fig. 13 8 DePuy Synthes IMF Screw Set Surgical Technique

Instruments and Implants Instrument Set for IMF Screws (174.736) Module IMF Screws (674.736) IMF Screws, Stainless Steel (201.928/932) Diameter 2.0 mm Length 8 and 12 mm Cerclage Wire, Stainless Steel (291.240) Diameter 0.6 mm Length 175 mm Handle, medium, with Quick Coupling (311.421) Screwdriver Shaft 2.4, cruciform, not self-holding (313.448) Holding Sleeve (313.970) IMF Screw Set Surgical Technique DePuy Synthes 9

Instruments and Implants Drill Bit B 1.5 mm with Stop (317.680) Length 44.5/8 mm, 2-flute, for J-Latch Coupling Drill Bit B 1.5 mm with Stop (317.720) Length 44.5/12 mm, 2-flute, for J-Latch Coupling Wire Twister (398.906) Wire-Cutting Scissors, Straight (398.909) Additionally available: Module, small, for IMF Screws B 2.0 mm (304.728) Screwdriver Shaft 2.4, cruciform, self-holding, for Quick Coupling (314.447) Drill Bit B 1.5 mm with Stop, length 44.5/8 mm, 2-flute, for Mini Quick Coupling (317.780) Drill Bit B 1.5 mm with Stop, length 44.5/12 mm, 2-flute, for Mini Quick Coupling (317.820) 11 DePuy Synthes IMF Screw Set Surgical Technique

DSEM/CMF/0115/0052(1) 06/15 Synthes GmbH Eimattstrasse 3 4436 Oberdorf Switzerland Tel: +41 61 965 61 11 Fax: +41 61 965 66 00 www.depuysynthes.com This publication is not intended for distribution in the USA. All surgical techniques are available as PDF files at www.depuysynthes.com/ifu 0123 DePuy Synthes CMF, a division of Synthes GmbH. 2015. All rights reserved. 036.000.325