R3think your options. For US distribution only.

Similar documents
Reaching new heights. Comprehensive. Efficient. Simple.

We would like to thank the following surgeons for their participation as part of the R3 Acetabular System design team:

One system for all revision types

Design Rationale. ECHELON Primary Hip System

Dr. John Masonis Charlotte, NC OrthoCarolina. Dr. James Waddell Toronto, Ontario University of Toronto, St. Michael s Hospital

REFLECTION Constrained Liner Introduction

Trusted technology. Trusted performance. Supporting healthcare professionals

Specifications guide ECHELON. Hip System

Understanding Hip Implant Options

Product Information. *smith&nephew POLARCUP Dual Mobility System

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Explore the possibilities

Arcos Modular Femoral Revision System

PINNACLE REVISION CUP SYSTEM

The Leader in Orthopaedic Innovation

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

EMPERION Modular Hip System was designed in conjunction with: Robert Barrack, MD St. Louis, MO. Mathias Bostrom, MD New York, NY

Zimmer Segmental System

Optimum implant geometry

The power of simplicity

CERAMIC-ON-METAL. References: Cat No: version 2

Trinity. Advanced Bearing Acetabular System Surgical technique

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Manza Cup HA SURGICAL TECHNIQUE.

*smith&nephew POLARCUP Dual Mobility System. Product Information

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

TOTAL HIP REPLACEMENT:

Duraloc CONSTRAINED LINER

Featuring. Technology. Product Rationale

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear

Optimum implant geometry

Bone Bangalore

INTERTAN Nails Geared for Stability

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

Comprehensive. Simple. Efficient.

ACETABULAR CUP SURGICAL TECHNIQUE

G7 ACETABULAR SYSTEM. beautifully. efficient.

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Stability without compromise. Epsilon Durasul Constrained Insert

Bone Preservation Stem

*smith&nephew CONTOUR

28 Surgical Technique

Optimum implant geometry

Surgical Technique. Poly and Ceramic

A better knee replacement begins with you

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

DURALOC. Acetabular Cup System. Surgical Technique

PLR. Proximal Loading Revision Hip System

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Trabecular Metal Natural Cup System

Clinical Evaluation Surgical Technique

The information contained in this document is intended for healthcare professionals only.

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Surgical Technique. Revision Acetabular System Acetabular Augments

Recertification Program. JET-X <> External Fixator

Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Surgical Technique. Cup System

The information contained in this document is intended for healthcare professionals only.

PROPHECY INBONE. Preoperative Navigation Guides

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery

RECOVERY. P r o t r u s i o

Surgical Technique. *smith&nephew. REFLECTION NO HOLE Acetabular Shell. REFLECTION THREE HOLE Acetabular Shell

Product Rationale. Where Strength and Modularity Connect

Trabecular Metal Primary Hip Prosthesis

Comprehensive Reverse Shoulder System

LEGION Total Knee System. Exceptional Durability

Bi-Polar 22.2mm & 28mm System - Operative technique

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

The TRIGEN SURESHOT system has my back.

Does the self-centering mechanism of bipolar hip endoprosthesis really work in vivo?

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

DISLOCATION OF THE TOTAL HIP Arthroplasty

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

Trabecular Metal Acetabular Revision System Cemented Constrained Liner

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

Scan Bi-Polar 22/28. Operative Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

The next generation in all suture implant technology. Q-FIX All-Suture Implants

Surgical Technique. Hinge Disassembly and Rebuild Technique

Knee spanning solutions

Hip Product Brochure

Making strides toward effective diabetic foot treatment. Foot and ankle solutions from smith&nephew

Allofit /Allofit -S Alloclassic Acetabular Cup System

GENESIS II/ LEGION Total Knee System

INTENDED FOR NON-US USE ONLY

Transcription:

R3think your options For US distribution only.

R3think acetabular surgery It is widely accepted that total hip replacement surgery is one of the most successful procedures done today. Typically more thought is given to the choice of stem, than the acetabular prosthesis. So why should you think about your acetabular prosthesis? Does your acetabular system offer optimal bearing options? With the R3 system, you have a wide range of possibilities from OXINIUM heads on XLPE, to ceramic-on-ceramic. No longer are your bearing options limited by your choice of acetabular shell. Is shell fixation important to you? Boney ingrowth has been shown to initiate within two to three weeks of implantation with porous coatings, 1 but what is happening in those first few weeks? Can the implant move? With STIKTITE porous coating, the implant is designed to have excellent initial fixation. STIKTITE coating has been shown to have a higher coefficient of friction against cortical and cancellous bone than trabecular metal. 2 STIKTITE coating has also been shown to be more stable over time than last generation porous coatings. 3 The R3 system gives you the security of knowing that your cup will stay where you put it. Are postoperative impingement, dislocation and range of motion important to you? When using most acetabular systems, the liner does not sit flush with the shell. With the R3 system, we have maximized the range of motion by ensuring that all of our liners sit flush with the rim of the cup and that our head-to-shell diameter ratios are optimized. Combine the R3 system with a Smith & Nephew stem and gain even greater range of motion due to our circulotrapezoidal neck geometry. 4,5,6,7

R3think bearings Not every patient requires the same type of bearing. So why limit your options? The R3 Acetabular System supports XLPE and ceramic liners allowing you to decide what is right for your patient without changing your system.

R3think stability At Smith & Nephew we know that stability is crucial to the success of any hip surgery. The R3 Acetabular System is designed to address stability from all angles. Our revolutionary STIKTITE porous coating provides proven cup stability, 3,8 and our unique locking system provides outstanding liner stability with all bearing options. 9 Jump distance q ROM Joint stability and head-to-shell ratios With the R3 system, we have optimized our head-to-shell ratio. Larger diameter heads have the potential to increase the jump distance and possibly reduce the dislocation risk. Additionally, R3 liners sit flush with the rim of the cup to increase ROM and reduce impingement. 4,5,6,7 q R3 XLPE liner locking mechanism R3 ceramic liner locking mechanism Cup stability and STIKTITE STIKTITE coating on an R3 Acetabular Shell ensures a true scratch-fit feel immediately upon impaction. This is because STIKTITE coating has been shown to have a higher coefficient of friction than trabecular metal against all types of bone. 2 Also, STIKTITE coating has pores that are ideally sized to allow for exceptional boney ingrowth properties. In fact, STIKTITE has been shown to be more stable in the acetabulum when compared to last generation porous coatings. 3 All of these features ensure your cup will stay where you put it. Liner stability and R3 locking system The unique R3 locking system not only accepts multiple bearings, it provides exceptional stability and protection to our XLPE liner while preventing soft tissue entrapment. The double channel lock is located deep within the shell to ensure axial stability of our XLPE liner. The 12 large anti-rotational tabs provide rotational stablity.

R3think confidence Confidence in hip surgery comes from knowing that you are going to have a successful result before you start. We designed the R3 system to help ensure that you get consistently great results every time. Simple instrumentation The R3 system uses one streamlined set to implant all of your bearing options both now and in the future. Liner seating All R3 bearings sit flush with the rim of the shell, which increases the range of motion and reduces the opportunity for impingement postoperatively. 4,5,6,7 This also provides intraoperative tactile feedback that the liner is fully seated inside the shell. Alignment ring The R3 ceramic liner comes preloaded with an alignment ring. The alignment ring ensures that the liner seats in the shell each and every time. 10,11

R3 liner offering chart XLPE Ceramic Cup size 22 28 32 36 40 44 28 32 36 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80

Orthopaedic References 1 Lopez-Heredia MA, et al, Bone growth in rapid prototyped porous titanium implants, Journal of Biomedical Materials, Part A, pp. 664-673, 2007. 2 Heiner AD, Brown TD. Frictional coefficients of a new bone ingrowth structure. Poster no. 1623 presented at: Orthopaedic Research Society Annual Meeting; Feb 11-14, 2007; San Diego, CA. 3 Bourne, RB, McCalden, RW, Naude, D, Cherron, KDJ, Yuan, X, Holdsworth, DW. The next generation of acetabular shell design and bearing surfaces. Supplement to Orthopaedics Innovation in Total Hip Arthroplasty, pp. 92-96, December 2008. 4 Berry DJ, von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2005 Nov; 87(11):2456 2463. 5 Barrack RL, Butler RA, Laster DR, Andrews P. Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling. J Arthroplasty. 2001 Dec; 16(8 Suppl 1):8 12. 6 Barrack RL. Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003 Mar-Apr; 11(2):89 99. 7 Barrack RL, Lavernia C, Ries M, Thornberry R, Tozakoglou E. Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. Orthop Clin North Am. 2001 Oct; 32(4):569 577, vii. 8 Bourne R. Randomized controlled trial to compare acetabular component fixation of two porous ingrowth surfaces using RSA analysis. London, Ontario, Canada: London Health Science Center. 2007. Internal report on file at Smith & Nephew, Memphis, TN. 9 Internal Smith & Nephew testing on file. 10 Padgett DE, Miller AN, Su EP, Bostrom MPG, Nestor BJ. Ceramic liner malseating in total hip arthroplasty. Poster PO97 at American Academy of Orthopaedic Surgeons; Feb 14 18, 2007; San Diego, CA. 11 Langdown AJ, Pickard RJ, Hobbs CM, Clarke HJ, Dalton DJ, Grover ML. Incomplete seating of the liner with the Trident acetabular system: a cause for concern? J Bone Joint Surg Br. 2007 Mar; 89(3):291 295. Smith & Nephew, Inc. 7135 Goodlett Farms Parkway Cordova, TN 38016 USA www.smith-nephew.com Telephone: 1-901-396-2121 Information: 1-800-821-5700 Orders and Inquiries: 1-800-238-7538 Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off. For US distribution only. 2013 Smith & Nephew, Inc. 00373 V1 09/13