Abstract Patients and Methods:

Similar documents
Original Article INTRODUCTION. Abstract

The Effect of Bispectral Index Monitoring on Anesthetic Use and Recovery in Children Anesthetized with Sevoflurane in Nitrous Oxide

Evaluation of Postoperative Complications Occurring in Patients after Desflurane or Sevoflurane in Outpatient Anaesthesia: A Comparative Study

Original Article. * Received for Publication: September 2, 2006 * Revision Received: December 27, 2006 * Revision Accepted: April 4, 2007

Hypotension after induction, corrected with 20 mg ephedrine x cc LR EBL 250cc Urine output:

COMPARISON OF RECOVERY PROFILES OF PROPOFOL & SEVOFLURANE ANESTHESIA WITH BISPECTRAL INDEX MONITORING (BIS) IN GENERAL ANESTHESIA

HEMODYNAMIC PROFILE DURING LAPAROSCOPIC CHOLECYSTECTOMY VERSUS LAPAROSCOPIC BARIATRIC SURGERY

Inhalational Agents in Bariatric Procedures

BIS Technology Enabling safety and quality improvements in the cardiac operating room

Comparison of Hemodynamic, Emergence and Recov Ery Characteristics of Sevoflurane with Desflurane in General Anesthesia

Abstract. Introduction

Type of intervention Anaesthesia. Economic study type Cost-effectiveness analysis.

The correlation of bispectral index with endtidal sevoflurane concentration and haemodynamic parameters in preschoolers

Monitoring cortical electrical activity in anesthesia for obese patient

Remifentanil. Addressing the challenges of ambulatory orthopedic procedures 1-3

Setting The setting was tertiary care. The economic study appears to have been performed in Heidelberg, Germany.

Multi-center (5 centers); United States and Canada. September 10, 1992 to April 9, 1993

RIA ABSTRACT INTRODUCTION MATERIALS AND METHODS

Comparing Patient Recovery after Laparoscopic Surgery for Women using Bispectral Index and Standard Clinical Method

COMPARISON OF INDUCTION WITH SEVOFLURANE-FENTANYL AND PROPOFOL-FENTANYL ON POSTOPERATIVE NAUSEA AND VOMITING AFTER LAPAROSCOPIC SURGERY

Original contribution. Department of Anesthesiology, Sapporo Medical University, School of Medicine, Sapporo, Hokkaido, Japan

BIS Monitoring. ASSESSMENT OF DEPTH OF ANAESTHESIA. Why measure depth of anaesthesia? or how to avoid. awareness in one easy lesson

Bispectral index (Bis) guided comparison of control of haemodynamic responses by fentanyl and butorphanol during tracheal intubation in neurosurgical

Tracheal intubation in children after induction of anesthesia with propofol and remifentanil without a muscle relaxant

INTUBATING CONDITIONS AND INJECTION PAIN

Childhood Obesity: Anesthetic Implications

Mr David A McDonald Service Improvement Manager Whole System patient Flow Improvement Programme Scottish Government

ABSTRACT. Alexandria Journal of Anaesthesia and Intensive Care INTRODUCTION. AJAIC-Vol. (9) No. 1 Marsh 2006

Mark D. Antoszyk, CRNA, BS Director Anesthesia Services Department of Anesthesiology Carolina s Medical Center Northeast Concord, North Carolina

Setting The setting was a hospital (tertiary care). The economic study was carried out in Ankara, Turkey.

DEXAMETHASONE WITH EITHER GRANISETRON OR ONDANSETRON FOR POSTOPERATIVE NAUSEA AND VOMITING IN LAPAROSCOPIC SURGERY

SEEING KETAMINE IN A NEW LIGHT

Efficacy of a single-dose ondansetron for preventing post-operative nausea and vomiting

Manual versus target-controlled infusions of propofol

January 27, 1992 to November 26, A total of 120 patients (60/site) were enrolled in the study as follows: PATIENT ENROLLMENT

A SAFE AND EFFECTIVE WAY TO OPTIMIZE ANESTHESIA DURING SURGERY

Bispectral index monitoring does not improve early recovery of geriatric outpatients undergoing brief surgical procedures

Dexamethasone Compared with Metoclopramide in Prevention of Postoperative Nausea and Vomiting in Orthognathic Surgery

Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients

Table showing induction time (seconds) among studied groups Induction time (Seconds)

Use of cerebral monitoring during anaesthesia: Effect on recovery profile

Sleep Apnea and ifficulty in Extubation. Jean Louis BOURGAIN May 15, 2016

Chapter 25. General Anesthetics

Comparative randomized study of propofol target-controlled infusion versus sevoflurane anesthesia for third molar extraction

A PROSPECTIVE, RANDOMIZED COMPARISON OF THE EFFECTS OF THIOPENTAL AND PROPOFOL ON BISPECTRAL INDEX DURING CAESAREAN SECTION TILL DELIVERY OF NEWBORN

Cover Page. The handle holds various files of this Leiden University dissertation.

Bispectral Index Monitoring Improves the Cognitive Function after Desflurane Anaesthesia in Elderly Patients Undergoing Spine Surgery

Research Article. Shital S. Ahire 1 *, Shweta Mhambrey 1, Sambharana Nayak 2. Received: 22 July 2016 Accepted: 08 August 2016

Awake regional versus general anesthesia in preterms and ex-preterm infants for herniotomy

Pediatric Evaluation of the Bispectral Index (BIS) Monitor and Correlation of BIS with End-tidal Sevoflurane Concentration in Infants and Children

Regional versus general anesthesia in patients underwent hip fracture surgery over 80 years old: A retrospective cohort study

Rauf et al. The evidence for this effect is equivocal. Studies of volunteers and non-cardiac surgery patients have concluded that there is no toleranc

Comparison of remifentanil versus fentanyl general anesthesia for short outpatient urologic procedures

ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

MYASTHENIA GRAVIS AND SEVOFLURANE

Current Therapeutic Research

The bispectral index (BIS) monitor was developed

Optimal Effect-Site Concentration of Remifentanil for Inhibiting Response to Laryngeal Mask Airway Removal during Emergence

The effect of desflurane on rocuronium onset, clinical duration and maintenance requirements

Beta Blockers for ENT Surgery

Operating room efficiency is regulated by several

Anesthesia Monitoring. D. J. McMahon rev cewood

Post-operative nausea and vomiting after gynecologic laparoscopic surgery: comparison between propofol and sevoflurane

Bispectral Index Monitoring Improves the Cognitive Function After Desflurane Anaesthesia in Elderly Patients Undergoing Spine Surgery

M. Martikainen *, T. Kangas-Saarela, A. Löppönen, P. Ohtonen, T. Salomäki

Comparison of the Optimal Effect-site Concentrations of Remifentanil for Preventing Cough during Emergence from Desflurane or Sevoflurane Anaesthesia

Effects on the Bispectral Index during Elective Caesarean Section: A Comparison of Propofol and Isoflurane

Arterial blood and end-tidal concentrations of sevoflurane during the emergence from anesthesia in gynecologic patients

The Sparing Effect of Low-dose Esmolol on Sevoflurane during Laparoscopic Gynaecological Surgery

Management of post-strabismus nausea and vomiting in children using ondansetron: a value-based comparison of outcomes 1^

Bariatric Surgery. Keitha Kirkham RN, BScN

Abstract. Med. J. Cairo Univ., Vol. 77, No. 3, June: , MAGDA S. AZER, M.D.

Anesthetic Techniques in Endoscopic Sinus and Skull Base Surgery

INTRACEREBRAL HEMORRHAGE FOLLOWING ENUCLEATION: A RESULT OF SURGERY OR ANESTHESIA?

AUSTRALIAN PRODUCT INFORMATION REMIFENTANIL APOTEX (REMIFENTANIL HYDROCHLORIDE) POWDER FOR INJECTION

A comparison of endotracheal intubation and use of the laryngeal mask airway for ambulatory oral surgery patients Todd D W

Sux Rocs and Roc Suks? Succinocholyne Vs Rocuronium in RSI

Effect of Vecuronium in different age group

Original Article Awakening from anesthesia using propofol or sevoflurane with epidural block in radical surgery for senile gastric cancer

Effect of remifentanil or esmolol on bispectral index and entropy to tracheal intubation during propofol anesthesia

Comparison of Drugs and Intravenous Crystalloid in Reduction of Postoperative Nausea and Vomiting after Laparoscopic Surgery

May 2013 Anesthetics SLOs Page 1 of 5

Introduction to Anesthesia

Use of the Intubating Laryngeal Mask Airway

D DAVID PUBLISHING. 1. Introduction. Juan LUO

Monitoring for Unconsciousness During General Anaesthesia

Inhalational Anesthesia. Munir Gharaibeh, MD, PhD, MHPE School of Medicine The University of Jordan February, 2018

Study Of Effects Of Varying Durations Of Pre-Oxygenation. J Khandrani, A Modak, B Pachpande, G Walsinge, A Ghosh

Problem Based Learning. Problem. Based Learning

PHYSICIAN COMPETENCY FOR ADULT DEEP SEDATION (Ages 14 and older)

THE EFFECT OF POSITIVE PRESSURE VENTILATORY PATTERNS ON POST-BYPASS LUNG FUNCTIONS

HST-151 Clinical Pharmacology in the Operating Room

British Journal of Anaesthesia 96 (6): (2006) doi: /bja/ael092 Advance Access publication April 13, 2006 Emergence and recovery in childr

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

Pharmacology: Inhalation Anesthetics

Anesthesiology, V 91, No 6, Dec 1999

Effect of preoperative oral amantadine on intraoperative anesthetic and analgesic requirements in female patients during abdominoplasty

A comparison of different proportions of a ketaminepropofol mixture administered in a single injection for patients undergoing colonoscopy

Respiratory Depression in the Early Postoperative Period. Toby N Weingarten, MD Mayo Clinic Professor Anesthesiology

Transcription:

EFFECT OF BISPECTRAL INDEX (BIS) MONITORING ON POSTOPERATIVE RECOVERY AND SEVOFLURANE CONSUMPTION AMONG MORBIDLY OBESE PATIENTS UNDERGOING LAPAROSCOPIC GASTRIC BANDING * OSAMA IBRAHEIM, AHAMAD ALSHAER, KHALID MAZEN ABDELAZEEM EL-DAWLATY, AHMED TURKISTANI, KHALED ALKATHERY, TARIQ AL-ZAHRANI, ABDULLAH AL-DOHAYAN AND AREEJ BUKHARI Abstract Early and uneventful postoperative recovery of morbidly obese patients remains a challenge for anesthesiologists. It could be valuable to titrate the administration of inhaled anesthetic, such as sevoflurane, in morbid obese patients, in order to shorten emergence using bispectral index (BIS) monitoring. It would be a great advantage if BIS permitted a more rapid recovery and less consumption in morbidly obese patients with a high cost inhaled agent. The aim of the study is to show whether the titration of sevoflurane based on the BIS monitoring would allow shortening of recovery time in morbidly obese patients and to evaluate whether BIS monitoring would contribute to reduce the amount of sevoflurane administered while providing an adequate anesthesia. Patients and Methods: Thirty morbidly obese ASA I & II patients undergoing laparoscopic gastric banding (LAGB) procedures were This article was presented as poster during 8 th Saudi Anesthesia Conference in Riyadh, November 2006 and won the first prize in the competition session. From Departments of Anesthesia and Surgery. * King Khalid University Hospital, King Saud University, Riyadh, Saudi Arabia. Address for Correspondence: Osama Ibraheim (Assistant Professor of anesthesia, Assiut University, Egypt). Consultant in Department of Anesthesia & ICU, College of Medicine, King Saud University, E-mail: osamaibraheim@yahoo.com, Riyadh 11472, P.O. Box: 7805, Saudi Arabia. 819 M.E.J. ANESTH 19 (4), 2008

820 O. IBRAHEIM ET. AL studied. In the first group (15 patients), patients were anesthetized without the use of BIS (non BIS or control group), and sevoflurane being administered according to standard clinical practice (control group). In the second group (15 patients), sevoflurane was titrated to maintain a BIS value between 40 and 60 during surgery, and then 60-70 during 15 min prior to the end of surgery (BIS group). Recovery times were recorded. Time to extubation was also noted, as well as the time to achieve a modified Aldrete score of 9 were evaluated subsequently at 10-min intervals until 3 h after surgery by nurses who had no knowledge of the study. Sevoflurane consumption was calculated using the vaporizer weighing method. Results: Awakening and extubation times were significantly shorter in the BIS group (P < 0.05). In the BIS (vs. non BIS) group, there were no significant differences observed in the time to obtain an Aldrete score of 9. The sevoflurane consumption and cost in the BIS group were lower than in the non BIS group (P < 0.05). Conclusion: Bispectral index monitoring during anesthesia for morbidly obese patients provides statistically significant reduction in recovery times. It also has the added advantage in decreasing sevoflurane consumption. Keywords: Bispectral index, Morbid Obesity, Sevoflurane consumption. Introduction Obesity is a leading cause of preventable death in the United States, resulting in >100,000 excess deaths per year 1 and an estimated annual cost of $ 70 billion, accounting for nearly 10% of national health care expenditures 2. The numerical growth of the obese population has been matched by an increase in the number of obese patients requiring hospitalization, bariatric procedures and intensive care unit (ICU) care 3-4, this, in part, reflects the increasing prevalence of obesity in the world 5. Morbid obesity has been identified as a risk factor for difficult mask

EFFECT OF BISPECTRAL INDEX (BIS) MONITORING ON POSTOPERATIVE RECOVERY IN MORBIDLY OBESE PATIENTS UNDERGOING LAPAROSCOPIC GASTRIC BANDING 821 ventilation, difficult laryngoscopy 6-7, and more frequent perioperative respiratory events 8-9. Traditionally, obesity has been seen as a physiologic state that magnifies the importance of the fat-blood solubility coefficient of the anesthetic in its relation to emergence and recovery, so early and uneventful postoperative recovery of morbidly obese patients remains a challenge for anesthesiologists. Bispectral index monitoring allows reduction in the total amount of anesthetic that patients are exposed to and appears to decrease time for emergence and recovery 11-12. However, it could be even more valuable to titrate the administration of some inhaled anesthetic, such as sevoflurane, in morbid obese patients, the hypothesis being to shorten emergence from sevoflurane anesthesia by using BIS monitoring. It would be a great advantage if BIS permitted a more rapid recovery and less consumption in morbidly obese patients with a high cost inhaled agent. No studies have investigated the potential usefulness of BIS monitoring to guide the administration of sevoflurane in morbid obese patient. In a randomized prospective controlled design, the present study evaluated and compared a BIS-monitored and a non-bis-monitored anesthesia among morbidly obese patients undergoing laparoscopic gastric banding, to show whether the titration of sevoflurane, based on the BIS monitoring, would allow shortening of recovery time. The secondary objective is the to show whether BIS monitoring would contribute to reduction of the amount of sevoflurane administered while at the same two providing an adequate anesthesia. Patients & Methods After institutional Review Board approval, thirty morbidly obese (BMI >35 kg/m2), ASA I & II patients to undergo gastric banding procedures, were studied. Exclusion criteria consisted of renal, hepatic or neurological dysfunction or use of benzodiazepines, anticonvulsants, alcohol, opioids or other psychotropic drugs. Patients were randomly assigned to two groups: M.E.J. ANESTH 19 (4), 2008

822 O. IBRAHEIM ET. AL First group, (15 patients) were anesthetized without the use of BIS (non BIS or control group), and sevoflurane being administered according to standard clinical practice. The second group, (15 patients) sevoflurane was titrated to maintain a BIS value between 40 and 60 during surgery, and then 60-70 during 15 min prior to the end of surgery (BIS group). Recovery times were defined from the end of surgery: Time to awakening (i.e, medications were dosed to ideal body weight; no sedative premedication was administered prior to surgery. Opening eyes on verbal command) was assessed at 1-min intervals in the operative room by the anesthetist. Time to extubation was also noted, as well as the time to achieve a modified Aldrete score of 9 were evaluated subsequently at 10- min intervals until 3 h after surgery by nurses who had no knowledge of the study. Sevoflurane consumption was calculated using the vaporizer weighing method. Table 1 Demographic data, Intraoperative and Post anesthetic data for the Non BIS Control and the BIS groups. Non BIS group (Control n = 15) BIS group (n = 15) Gender (M/F) 11/4 9/6 ASA (I & II) 10/5 8/7 Age (yr) 41.21 ± 5.07 39 ± 4.50 Weight (kg) 126.8 ± 12.4 124.8 ± 11.6 Height (Cm) 180.6 ± 8.3 176.6 ± 9.6 BMI (kg/m 2 ) 45.8 ± 7.5 43.2 ± 5.07 Total duration of anesthesia (min) 138.9 ± 13.8 136.6 ± 13.7 Mean intraoperative MAP (mmhg) 85.6 ± 3.7 83.7 ± 2.4 Mean intraoperative HR (beats/min) 66 ± 10 65 ± 9 Sevoflurane consumption (ml/h) 19.60 ± 3.94 15.66 ± 4.04 ml * Recovery times (min) Awakening 8.66 ± 2.6 6.80 ± 2.14 * Extubation 11.80 ± 2.9 9.26 ± 2.01 * Aldrete score of 9 31. ± 4.81 29.8 ± 4.74

EFFECT OF BISPECTRAL INDEX (BIS) MONITORING ON POSTOPERATIVE RECOVERY IN MORBIDLY OBESE PATIENTS UNDERGOING LAPAROSCOPIC GASTRIC BANDING 823 * Significance = P < 0.05. Induction consisted of fentanyl 2 μg/kg, propofol 1.5 to 2.0 mg/kg, and succinylcholine 1.00 to 1.5 mg/kg. Bispectral index monitoring (BIS A-2000 software 2.21, Aspect Medical Systems, Newton, and Mass) was initiated at induction, and smoothing time was 30 seconds. Standard monitoring (oxygen saturation [SpO2], electrocardiogram, end-tidal carbon dioxide [ETCO2], indirect or direct blood pressure (BP), and esophageal temperature probe) were used in all patients. Sevoflurane (2%) in 2 L/min fresh gas flow, mixed in air and oxygen, was administered to all patients for 5 min after endotracheal intubation and until skin incision, the concentrations were then changed every 5 min as follows: - BIS Group: the anesthesiologist had access to the monitor and adjusted the concentration of sevoflurane to achieve a target BIS in the range 40-60. - Non BIS (control group) the anesthesiologist adjusted the sevoflurane concentration purely according to the clinical signs. During operation, the patients in both groups were observed for signs of inadequate anesthesia (Table 2). Significant hypotension or bradycardia was defined as 20% reduction of the baseline figures. Any instances of inadequate anesthesia were managed by increasing the concentration of sevoflurane. Table 2 Criteria for inadequate anesthesia Hypertension: blood pressure 20% increase from baseline Relative tachycardia: heart rate 90 beats min/l Somatic movement, grimacing, eye opening, coughing Atracurium neuromuscular blockade was maintained to a single twitch of the train of four. During the last 15 minutes of the case, the BIS value was gradually titrated to 60-70 by decreasing the inhaled anesthetic concentration. Intravenous fentanyl 100 μg was used approximately 15 minutes before the end of surgery to control early postoperative pain. M.E.J. ANESTH 19 (4), 2008

824 O. IBRAHEIM ET. AL Just before skin closure and before application of surgical dressing, neuromuscular blockade was reversed with neostigmine (0.07 mg/kg) and glycopyrrolate (0.015 mg/kg). Fresh gas flows were increased to 10 L/min and the anesthetic was discontinued after application of dressing. Mechanical ventilation (10 ml/kg ideal body weight) was continued until the first spontaneous respiration began, followed by assisted manual ventilation. A verbal command to open eyes was given every 10 seconds. After a train-of-four ratio higher than 0.9, a 5-second head lift was performed and patients were extubated. Blinded study personnel recorded the time from discontinuation of the anesthetic gas to eye opening and extubation. After extubation, patients were transferred to the (PACU). In the PACU the time to achieve a modified Aldrete score of 9 was evaluated subsequently at 10-min intervals until 3 h after surgery by nurses who had no knowledge of the study. Postoperative pain was evaluated at 5-min intervals using a 5-point verbal rating scale (0: no pain; 1: light pain; 2: moderate pain; 3: intense pain; 4: severe pain). Pain scores were treated with Ketoprofen 100 mg IM. At the time of discharge from the recovery room and 24 hours after surgery, patients were asked whether they dreamt or recalled any intraoperative events. Sevoflurane Consumption For determination of anesthetic consumption, the sevoflurane vaporizer was filled and weighed before induction. When anesthesia was complete, the vaporizer was disconnected and reweighed. This method has already been described by other authors 13-14. Inhaled anesthetic consumption was expressed in g/min and assessed for each patient. Conversion from grams to milliliters was performed by using the specific weights of the volatile anesthetic (sevoflurane 1.52 g/ml). The mean value of each group was then established and the difference between the two means in ml/h. was established Results were statistically evaluated

EFFECT OF BISPECTRAL INDEX (BIS) MONITORING ON POSTOPERATIVE RECOVERY IN MORBIDLY OBESE PATIENTS UNDERGOING LAPAROSCOPIC GASTRIC BANDING 825 using Student s t-test (significance P < 0.05). Statistics Data was collected statistically and analyzed using SPSS package (version 11.0, Washington). One-way repeated-measures analysis of variance (ANOVA) with post hoc Bonferroni correction was used to assess differences in mean between groups with respect of specific intraoperative events. The two-sample unpaired Student s t-tests were used to compare continuous variables: HR, MAP, duration of anesthesia, recovery times, and sevoflurane consumption. Data are expressed as mean values ± SD. P values <0.05 were considered statistically significant. Results Thirty morbidly obese patients were enrolled in this study and were equally divided into two groups (n = 15 each): Non-BIS group (Control) and BIS group (Table 1). The two groups were similar in age, height, age, weight, BMI and duration of anesthesia. There were no statistical differences in intraoperative mean heart rate, mean blood pressure in either group. The time to awakening and extubation (time from end of operation to time of verbal command) was shorter in the BIS group: The Awakening time was 8.66 ± 2.69 min in the Non-BIS gr. (control), compared to 6.80 ± 2.14 min in the BIS gr., with P < 0.05 *. The Extubation time was 11.8 ± 2.9 min in the Non-BIS gr. (control), compared to 9.26 ± 2.01 min with in the 815 gr., with P < 0.05 *. No significant differences were observed in the time to obtain an Aldrete score of 9 in the BIS vs Non-BIS groups. The sevoflurane consumption and costs in the BIS group were lower than in the Non-BIS group. The mean ± SD for the consumption per hour of sevoflurane was 19.60 ± 3.94 ml liquid in the Non-BIS gr, M.E.J. ANESTH 19 (4), 2008

826 O. IBRAHEIM ET. AL compared to 15.66 ± 4.04 ml liquid in the BIS gr., with P < 0.05 *. * Significance = P < 0.05. There was no recall or dreaming reported by any patient in Recovery room or 24 hours after surgery in both groups. All patients were completely awake during the three postoperative hours without complications. Discussion The hypothesis adopted in the present study was that sevoflurane titration guided by BIS monitoring could be particularly useful at the end of surgery in order to adapt sevoflurane delivery to a higher BIS level and order to ensure a faster recovery. We demonstrated that the addition of BIS to standard monitoring was associated with a slight but significant decrease in sevoflurane consumption. Also, there was a significant difference in recovery times when comparing BIS guided and standard monitoring anesthesia. These results are comparable to those reported in other studies that assessed titration of propofol 15, desflurane or sevoflurane 16-17 by using BIS monitoring but not in morbidly obese patients. Bispectral index monitoring allows reduction in the total amount of anesthetic that patients are exposed to and appears to decrease time for emergence and recovery 11-18. In the present study, the protocol was designed as a single blinded comparison of the anesthetic administration, as sevoflurane was titrated intraoperatively against objective measures such as BIS, HR, MAP, and patient movements. Early recovery in the operative room (time to awakening and to extubation) was assessed by another anesthesia provider, that does not constitute an investigator associated bias. In addition, in the PACU, the nursing staff had no knowledge of the study. Furthermore, all anesthesia providers were anesthetists in our Department and had experience of more than 5 years in anesthesiology.

EFFECT OF BISPECTRAL INDEX (BIS) MONITORING ON POSTOPERATIVE RECOVERY IN MORBIDLY OBESE PATIENTS UNDERGOING LAPAROSCOPIC GASTRIC BANDING 827 Bispectral index monitoring has been incorporated into studies comparing emergence and recovery profiles of desflurane and sevoflurane, mixed with nitrous, in elderly patients 19 and was incorporated into the study of De Baerdemaeker et al 20. These studies all demonstrate that the time to recovery is shortened compared with previous non-bisguided studies where the dosage of desflurane or sevoflurane was based on MAC and hemodynamic response, whether mixed with nitrous oxide 21 or not 22. We agree with the contention that a rapid emergence from anesthesia with minimal respiratory and cardiovascular adverse effects is important in MO patients who have a high prevalence of cardiovascular disease and are at risk for respiratory complications. White et al. 23 found that AEP and bispectral index (BIS) monitoring can decrease the end-tidal desflurane concentration during maintenance of anesthesia and discharge times after the end of anesthesia. During laparoscopic surgery, Recart et al. 24 found that AEP monitoring can reduce the desflurane requirement by 26%. It has been shown that excessive costs can be minimized without compromising clinical outcome and patient satisfaction. Comparing anesthesia costs is not a trivial matter. Two studies published in 1999 investigated outpatients anesthetized with propofol and/or sevoflurane 25 : Tang and colleagues 26 focused on the total costs required to achieve complete patient satisfaction and found that propofol/propofol-n 2 O were the cheapest kind of anesthesia, followed by propofol/sevoflurane N 2 O and sevoflurane/sevoflurane-n 2 O. The present study showed that the use of BIS guided sevoflurane for the maintenance of anesthesia in morbidly obese patients was less expensive than maintenance of sevoflurane without BIS. We have demonstrated that the addition of BIS to standard monitoring was associated with a slight, significant, decrease in sevoflurane consumption. Yll-Hankala and colleagues found that the sevoflurane saving was 40% in gynecological surgery patients who also received opioids 27. Subsequently, other authors 28 using isoflurane found similar findings to those reported here. In that study, there was a 12% M.E.J. ANESTH 19 (4), 2008

828 O. IBRAHEIM ET. AL saving in isoflurane consumption when using BIS which was explained as a result of the use of sufentanil and nitrous oxide 28. Pavlin and colleagues found, in a study of junior residents who had differing durations of training, that a modest reduction of anesthetic use was associated with greater experience (13%) 29. For junior residents, the difference in the concentrations of volatile anesthetic administered to the BIS and control groups was quite remarkable. There was not much difference in the case of residents whose experience was >1 yr. In our study, our anesthetist had at least 5 or more years experience. In evaluating the values of BIS and control groups, experience of anesthesia is an important factor. Anesthesia costs during surgery constituted only 5.6% of the total hospital costs. Many opportunities may be found to reduce costs in operating suites 30-31. A fast recovery is important after surgery. In our study, patient assessment in recovery was conducted by blinded PACU nurses. There were significant differences in the time to open eyes on verbal command, the time to motor responds on verbal command between BIS and control group while no difference in Aldrete s score. This is in accordance with Song and colleagues who found that the duration of stay in the recovery unit did not differ 11 ; Guignard and colleagues also reported that the Aldrete s scores were also similar 28. Pavlin and colleagues also reported that BIS monitoring did not influence the duration of recovery 29. In conclusion, the recovery variables were shorter with BIS monitoring which in turn made significant savings in sevoflurane consumption and influenced the speed of recovery after laparoscopic gastric banding in morbidly obese patients.

EFFECT OF BISPECTRAL INDEX (BIS) MONITORING ON POSTOPERATIVE RECOVERY IN MORBIDLY OBESE PATIENTS UNDERGOING LAPAROSCOPIC GASTRIC BANDING 829 References 1. FLEGAL KM, GRAUBARD BI, WILLIAMSON DF, ET AL: Excess deaths associated with underweight, overweight, and obesity. JAMA; 293:1861-1867, 2005. 2. COLDITZ GA: Economic costs of obesity and inactivity. Med Sci Sports Exerc; 31:S663-S667, 1999. 3. SCHIRMER B, WATTS SH: Laparoscopic bariatric surgery. Surg Endosc; 18:1875-1878, 2004. 4. TRUS TL, POPE GD, FINLAYSON SR: National trends in utilization and outcomes of bariatric surgery. Surg Endosc; 19:616-620, 2005. 5. BJFRNTORP P. OBESITY: Lancet; 350:423-6, 1997. 6. JUVIN P, LAVAUT E, DUPONT H, ET AL: Difficult tracheal intubation is more common in obese than in lean patients. Anesth Analg; 97:595-600, 2003. 7. ROSE DK, COHEN MM: The airway: problems and predictions in 18,500 patients. Can J Anaesth; 41:372-83, 1994. 8. CHUNG F, MEZEI G: Adverse outcomes in ambulatory anesthesia. Can J Anaesth; 46:R18-R34, 1999. 9. PELOSI P, CROCI M, RAVAGNAN I, ET AL: The effects of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia. Anesth Analg; 87:654-60, 1998. 10. FISHER A, WATERHOUSE TD, ADAMS AP: Obesity: its relation to anaesthesia. Anaesthesia; 30:633-47, 1975. 11. SONG D, JOSHI GP, WHITE PF: Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia. Anesthesiology; 87:842-8, 1997. 12. GUIGNARD B, COSTE C, MENIGAUX C, CHAUVIN M: reduced isoflurane consumption with bispectral index monitoring. Acta Anaesthesiol Scand; 45:308-14, 2001. 13. MÄÄTTÄNEN H, ANDERSON R, UUSIJARVI J, JAKOBSSON J: Auditory evoked potential monitoring with the AAITM-index during spinal surgery: decreased desflurane consumption. Acta Anaesthesiol Scand; 46:882-6, 2002. 14. ASSAREH H, ANDERSON RE, UUSIJARVI J, JAKOBSSON J: Sevoflurane requirements during ambulatory surgery: a clinical study with and without AEP-index guidance. Acta Anaesthesiol Scand; 46:495-9, 2002. 15. GAN TJ, GLASS PS, WINDSOR A, PAYNE F, ROSOW C, SEBEL P, ET AL: and the BIS utility Study Group. Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia. Anesthesiology; 87:808-815, 1997. 16. SONG D, JOSHI GP, WHITE PE: Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia. Anesthesiology; 87:842-848, 1997. 17. YLI-HANKALA A, VAKKURI A, ANNILA P, KORTTILA K: EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery. Acta Anaesthesiol Scand; 43:543-549, 1999. 18. GUIGNARD B, COSTE C, MENIGAUX C, CHAUVIN M: Reduced isoflurane consumption with bispectral index monitoring. Acta Anaesthesiol Scand; 45:308-14, 2001. 19. HEAVNER JE, KAYE AD, LIN BK, KING T: Recovery of elderly patients from two or more hours of desflurane or sevoflurane anaesthesia. Br J Anaesth; 91:502-6, 2003. 20. DE BAERDEMAEKER LE, STRUYS MM, JACOBS S, ET AL: Optimization of desflurane administration in morbidly obese patients: a comparison with sevoflurane using and inhalation bolus technique. Br J Anaesth; 91:638-50, 2003. 21. NATHANSON MH, FREDMAN B, SMITH I, WHITE PF: Sevoflurane versus desflurane for outpatient anesthesia: a comparison of maintenance and recovery profiles. Anesth Analg; 81:1186-90, 1995. M.E.J. ANESTH 19 (4), 2008

830 O. IBRAHEIM ET. AL 22. NAIDU-SJFSV7RD K, SJFBERG, GUPTA A: Anaesthesia for videoarthroscopy of the knee. A comparison between desflurane and sevoflurane. Acta Anaesthesiol Scand; 42:464-71, 1998. 23. WHITE PF, MA H, TANG J, WENDER RH, SLONINSKY A, KARIGER R, ET AL: Does the use of electroencephalographic bispectral index or auditory evoked potential index monitoring facilitate recovery after desflurane anesthesia in the ambulatory setting? Anesthesiology; 100:811-7, 2004. 24. RECART A, WHITE PF, WANG A, GASANOVA I, BYERKY S, JONES SB, ET AL: Effect of auditory evoked potential index monitoring on anesthetic drug requirements and recovery profile after laparoscopic surgery. Anesthesiology; 99:813-8, 2003. 25. SMITH I, TERHOEVE PA, HENNART D, ET AL: A multicentre comparison of the costs of anaesthesia with sevoflurane or propofol. Br J Anaesth; 83:564-570, 1999. 26. TANG J, CHEN L, WHITE PF, ET AL: Recovery profile, costs, and patient satisfaction with propofol and sevoflurane for fast-track office-based anesthesia. Anesthesiology; 91:253-261, 1999. 27. YLL-HANKALA A, VAKKURI A, ANNILA P, KORTILLA K: EEG bispectral index monitoring sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery. Acta Anaesthesiol Scand; 43:545-549, 1999. 28. GUIGNARD B, COSTE C, MENIGAUX C, CHOUVIN M: Reduced isoflurane consumption with bispectral index monitoring. Acta Anaesthesiol Scand; 45:308-314 2001. 29. PAVLIN DJ, HONG Y, FREUND PR, KOERSCHGEN ME, BOWER JO, BOWDLE TA: The effect of bispectral index monitoring on end-tidal gas concentration and recovery duration after outpatient anesthesia. Anesth Analg; 93:613-619, 2001. 30. WATCHA MF, WHITE PF: Economics of anesthesia practice. Anesthesiology; 86:1170-1196, 1997. 31. JOHNSTONE RE, MARTINEC CC: Cost of anesthesia. Anesth Analg; 76:840-848, 1993.