Endovascular repair of an aortic arch pseudoaneurysm with double chimney stent grafts: a case report

Similar documents
Hybrid procedure to treat aortic arch aneurysm combined with aortic arch coarctation and left internal carotid artery aneurysm (Case Report)

Aortic Arch pathology options: Open,Hybrid, fenestration, Chimney or branched stent-graft?

WHAT IS THE BEST OPTION FOR ARCH ANEURYSMS?

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Modification in aortic arch replacement surgery

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Optimal repair of acute aortic dissection

Early Results of Left Carotid Chimney Technique in Endovascular Repair of Acute Non-A Non-B Aortic Dissections

Transcarotid Artery Endovascular Reconstruction of the Aortic Arch by Modified Bifurcated Stent Graft for Stanford Type A Dissection

CUSTOM-MADE SCALLOPED THORACIC ENDOGRAFTS IN DIFFERENT HOSTILE AORTIC ANATOMIES

EVAR and TEVAR: Extending Their Use for Rupture and Traumatic Injury. Conflict of Interest. Hypotensive shock 5/5/2014. none

Cite this article as:

Acute dissections of the descending thoracic aorta (Debakey

DISCLOSURES ISOLATED DTA LESION? TYPE B DISSECTIONS TREATMENT OPTIONS

Left subclavian artery (LSA) coverage during

Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

Technique and Outcome of Laser Fenestration For Arch Vessels

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique

Distal Arch and Descending Aorta: What Is the Optimal Therapy in 2017?

Endovascular Repair of Aortic Arch/Thoracic Aneurysms: Bolton RelayBranch Device

Abdominal and thoracic aneurysm repair

How to achieve a successful proximal sealing in TEVAR? Pr L Canaud

Ascending Aorta: Is The Endovascular Approach Realistic?

Type II arch hybrid debranching procedure

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Percutaneous Approaches to Aortic Disease in 2018

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Intravascular Ultrasound in the Treatment of Complex Aortic Pathologies. Naixin Kang, M.D. Vascular Surgery Fellow April 26 th, 2018

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Endovascular therapy for Ischemic versus Nonischemic complicated acute type B aortic dissection (catbad).

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

Aortic Arch Treatment Open versus Endo Evidence versus Zeitgeist. M. Grabenwoger Dept. of Cardiovascular Surgery Hospital Hietzing Vienna, Austria

Transcatheter Aortic Valve Implantation as a Bailout Procedure for Acute Aortic Valve Regurgitation During Endovascular Arch Repair

Hybrid Repair of a Complex Thoracoabdominal Aortic Aneurysm

No Disclosure. Aortic Dissection in Japan. This. The Challenge of Acute and Chronic Type B Aortic Dissections with Endovascular Aortic Repair

State of Art Hybrid Approach

Development of Stent Graft. Kato et al. Development of an expandable intra-aortic prothesis for experimental aortic dissection.

Combined Open and Endovascular Repair for Aortic Arch Pathology

Current State of Thoracic Branch Devices and Ongoing Clinical Trials

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

Residual Dissection and False Lumen Aneurysm After TEVAR

Toward Total Endovascular Therapy of the Aorta. Adam W. Beck, MD. Associate Professor of Surgery Division of Vascular Surgery and Endovascular Therapy

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Surgical Considerations of TEVAR

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

Minimally Invasive Aortic Arch Surgery:

Santi Trimarchi, MD, PhD Vascular Surgeon Thoracic Aortic Research Center, Director IRCCS Policlinico San Donato University of Milan

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Distal False Lumen Occlusion in Aortic Dissection With a Homemade Extra-Large Vascular Plug: The Candy-Plug Technique

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina

What is the best treatment for False Lumen growth after type B Dissection

Retrograde Embolization of a Symptomatic Hypogastric Artery Aneurysm

Pioneering EVAR techniques in aortic dissection

Reimbursement Guide Zenith Fenestrated AAA Endovascular Graft

Nellix Endovascular System: Clinical Outcomes and Device Overview

How to manage the left subclavian and left vertebral artery during TEVAR

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Percutaneous Axillary Artery Access For Branch Grafting for complex TAAAs and pararenal AAAs: How to do it safely

Vascular Intervention

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

The SPIDER-Graft for Thoracoabdominal Aortic Repair a feasability study in pigs

Changwei Ren 1, Xi Guo 2, Lizhong Sun 1, Lianjun Huang 2, Yongqiang Lai 1, Shangdong Xu 1. Introduction

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Total endovascular techniques utilization in aortic dissection radical treatment

Aortic Arch/ Thoracoabdominal Aortic Replacement

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

SCAI Fall Fellows Course Subclavian/Innominate Case Presentation

Thoracoabdominal Aorta: Advances and Novel Therapies

Human Thiel cadaveric flow model for training aortic endovascular interventional techniques

Paraplegia in endovascular repair of TAA and in TEVAR: Incidence, prevention and therapy. Johannes Lammer Medical University Vienna, Austria

Home-made Fenestrations for Various Pathologies of Abdominal Aorta

CT angiography at 24 months demonstrates durability of EVAR with the use of chimney grafts for pararenal aortic pathologies

Animesh Rathore, MD, RPVI Sentara Vascular Specialists. Debate 4: Complex endovascular aortic repair will make open surgery obsolete

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

What is the benefit. of MEP s in BEVAR for TAAA. in preventing paraplegia?

TEVAR for complicated acute type B dissection with malperfusion

Volume 3 (2017) Issue 1 ISSN Abstract. Keywords fenestrated after open repair; Pararenal abdominal aortic aneurysm.

COMPLICATIONS OF TEVAR

Redo treatment and open conversion after TEVAR

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject:

Safety and Efficacy of an Aortic Arch Stent Graft with Window-Shaped Fenestration for Supra-Aortic Arch Vessels: an Experimental Study in Swine

Stent graft modification with mini-cuff reinforced fenestrations for urgent repair of thoracoabdominal aortic aneurysms

Open fenestration for complicated acute aortic B dissection

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

Antegrade Thoracic Stent Grafting during Repair of Acute Debakey I Dissection: Promotes Distal Aortic Remodeling and Reduces Late Open Re-operation

Observational studies and registries comparing

I SECTION I. Thoracic aortic aneurysms

As it currently stands, the mortality rate of

Endovascular repair of ascending aorta pseudoaneurysm

Application of triple-chimney technique using C-TAG and Viabahn or Excluder iliac extension in TEVAR treatment of aortic arch dilation diseases

ENDOVASCULAR REPAIR OF COMPLEX EXTRA-CRANIAL SUPRA-AORTIC ANEURYSMS

P Paraplegia abdominal aortic aneurysm repair, 52 paraparesis, 52 pathophysiology, 51 rates and endografts, 51 two-stage approach, 129

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Thoracic aortic trauma A.T.O.ABDOOL-CARRIM ACADEMIC HEAD VASCULAR SURGERY DEPARTMENT OF SURGERY UNIVERSITY OF WITWATERSRAND

Transcription:

Zhou et al. Journal of Cardiothoracic Surgery 2013, 8:80 CASE REPORT Endovascular repair of an aortic arch pseudoaneurysm with double chimney stent grafts: a case report Weimin Zhou *, Wei Zhou and Jiehua Qiu Open Access Abstract Aortic arch pseudoaneurysm is a rare condition but carries a high risk of rupture. We report a case of a 45-year-old man with aortic arch pseudoaneurysm between left common carotid artery (LCCA) and left subclavian artery (LSA), in which a endovascular stent graft combined with double chimneys covered stents were successfully placed. There were no any complaints and complications after 12 months follow-up. The CTA demonstrated thrombus formation in the pseudoaneurysm lumen, no endoleak and the aortic arch, LCCA and LSA were all patent. We feel that the combined endovascular and double chimneys may be a valuable therapeutic alternative when treating aortic arch lesion. However, long-term clinical efficacy and safety have yet to be confirmed. Keywords: Pseudoaneurysm, Aortic arch, Stent graft, Endovascular repair Background Aortic arch pseudoaneurysm is a rare condition but carries a high risk of rupture. Previous reports that we have identified in English literature included conventional surgical repair, hybrid surgery,embolization of an aortic arch pseudoaneurysm with detachable coils and total endovascular debranching of the aortic arch or double-chimney technique [1-7]. Conventional surgical intervention requires a thoracotomy, cardiopulmonary bypass, hypothermic circulatory arrest and aortic crossclamping, remains a surgical challenge with a high rate of mortality (7-17%) and neurologic complication (4-12%) [1,2,8]. Minimally invasive endovascular repair in treating aortic arch pseudoaneurysm is a better choice. We present a case of aortic arch pseudoaneurysm between left common carotid artery (LCCA) and left subclavian artery (LSA), in which a endovascular stent graft combined with double chimneys covered stents were successfully placed. As we know, there was seldom reported in English literature. * Correspondence: drzwm@sina.com Department of Vascular Surgery, the second affiliated hospital of Nanchang University, Nanchang, China Case presentation A 45-year-old Chinese man was admitted to our center with a chief complaint of hoarseness. He had a history of hoarseness and syncope after a blunt trauma two months prior to presentation. The computed tomographic angiography (CTA) showed an aortic arch pseudoaneurysm between LCCA and LSA (5 mm from LCCA and 0 mm from LSA) with the caliber of tear and the size of pseudoaneurysm lumen being 15 mm and 50 mm, respectively. A digital subtraction angiography (DSA) was performed, and was in agreement with the CTA images. It also demonstrated that the left vertebral artery was dominant (Figure 1). The procedure was performed under general endotracheal anesthesia with full hemodynamic monitoring two days later. The right femoral artery was exposed through a groin oblique incision and cannulated with a 6-French catheter sheath from which an angiographic mark catheter was put into the ascending aortic artery via a 0.035 inch guidewire. The left brachial artery was exposed through a left upper arm longitudinal incision and cannulated with a 8- French catheter sheath from which a pigtail angiographic catheter was inserted into the ascending aortic artery via a 0.035 inch guidewire (Amplatz Super Stiff, Boston Scientific, USA). The LCCA was exposed through a left neck longitudinal incision and cannulated with an 2013 Zhou et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Zhou et al. Journal of Cardiothoracic Surgery 2013, 8:80 Page 2 of 5 Figure 1 Preoperative CTA and arteriography: Thoracic CT scan showing an irregular wall at level of aortic arch (A,B). Preoperative arteriography demonstrated a pseudoaneurysm was evident between the origin of the left common carotid artery and the left subclavian artery; the left vertebral artery was dominant (C). 8-French catheter sheath as well. The C arm was locked at left anterior oblique (LAO) 45 projection to thoroughly unfold the aortic arch that was cannulated with a 21-French delivery introducer sheath via a 0.035 inch Lunderquist super stiff guidewire (COOK, USA) through the right femoral artery. A thoracic endoprosthesis stent graft (TF2828C150X, VALIANTW, Medtronic Inc., USA) was accurately deployed and the oversize was 5%. Then two covered stents (8 mm 60 mm, Fluency, FVL08060, BARD, USA) were cannulated with an 8-French delivery introducer sheath via a 0.035 inch Amplatz super stiff guidewire through the left brachial artery and LCCA and was inserted parallel to the stent graft, respectively. The two covered stents were accurately deployed in the proximity of LSA and LCCA to avoid covering the left vertebral artery. Before deployment of the stent grafts, the mean arterial pressure was lowered to 90 mmhg to avoid grafts migration. An aortogram revealed no evidence of endoleak; disappearance of the aortic arch pseudoaneurysm lumen and patent of the aorta and the branch of aortic arch immediately after the stent deployment (Figure 2). The patient recovered from the procedures without complications and was discharged from the hospital in the next three days. Follow-up CTA 1 week later showed no filling or Figure 2 Postoperative arteriography: disappearance of the aortic arch pseudoaneurysm lumen, no evidence of endoleak and patent of the aorta and the branch of aortic arch immediately after deployment.

Zhou et al. Journal of Cardiothoracic Surgery 2013, 8:80 Page 3 of 5 enlargement of the pseudoaneurysm. The endoprosthesis intheaorticarchwerepatent,withoutevidenceofproximal endoleak. Covered stents in the LCCA and LSA were patent. The patient s postoperative course was favorable. The hoarseness was significantly alleviated two months later. As of 12 months after endovascular repair, the patient is well without any complaints and complications. Postoperative CTA demonstrated thrombus formation in the pseudoaneurysm lumen, no endoleak and the aortic arch, LCCA and LSA were all patent at 12-month follow-up (Figure 3). Discussion Reported treatment options for aortic arch pseudoaneurysms have included surgical grafts, ligation, pericardial roll graft replacement, embolization with coils, and the use of endovascular stent grafts combined with surgical treatment [1-7,9]. The conventional open surgery was gradually replaced by endovascular treatment due to the complexity of the surgery, surgical trauma and high associated mortality rate. Endovascular treatment is less invasive and is associated with lower morbidity and mortality [3-5]. Since endovascular procedure Figure 3 Follow-up CTA: CTA on the first week post-operative follow-up showed no evidence of proximal endoleak, no filling or enlargement of the pseudoaneurysm (A,B). Postoperative CTA demonstrated thrombus formation in the pseudoaneurysm lumen, no endoleak and the aortic arch, LCCA and LSA were patent in 12-month follow-up (C,D,E).

Zhou et al. Journal of Cardiothoracic Surgery 2013, 8:80 Page 4 of 5 does not require thoracotomy, circulatory assistance is not necessary and haemorrhages are less likely. What is more, endovascular intervention does not need aortic cross-clamping as such the risk of cerebral, spinal cord and visceral ischemia was decreased. Due to the lower morbidity and mortality rates, thoracic endovascular aortic repair (TEVAR) is considered an acceptable alternative to open surgical repair for patients with various types of aortic diseases. Despite these advantages, TEVAR are technical challenging. The common problem is the presence of an inadequate short proximal and distal landing zone. To achieve an adequate landing zone and sealing zone, the innominate artery, LCCA and LSA need occasionally to be covered. Modification of the stent graft is needed to overcome these limitations of TEVAR. The use of a fenestrated or branched stent graft, which is able to preserve perfusion of the supra-aortic arch vessels, could be one of the alternative approaches [10]. However, a fenestrated or branched stent graft is a custom made device, and is expensive and time consuming to manufacture so they cannot be used in an emergency setting [11,12]. In our patient, coil embolization and endovascular injection of embolic agents were not options because of the caliber of the aorta arch pseudoaneurysm tear (15 mm) and the size of pseudoaneurysm lumen (50 mm). The optimal option for treatment would be TEVAR. However, simple application of TEVAR to treat complicated aortic arch pseudoaneurysm such as in our patient may cause cerebral ischemia and infarction because of the limited landing zone and sealing zone. An alternative approach to this situation is applying the chimney graft technique to preserve blood flow to the supra-aortic arch vessels with a short landing zone, that would be impossible to repair with a standard stent graft [13]. The chimney graft is defined as a bare or covered stent that is placed parallel to the main stent graft to preserve blood flow to the supra-aortic arch vessel, which is covered to achieve the proper landing and sealing zone [14]. Since the procedure was introduced, the chimney graft has been successfully applied to preserve the blood flow of the carotid, subclavian, renal and superior mesenteric arteries during endovascular treatment of aortic disease [15-17]. LCCA and LSA covered stents implantation (double chimneys) would be protective of cerebral ischemia or cerebral infarction and subclavian artery steal syndrome. Our successful treatment in this patient suggests that the combined endovascular and double chimneys may be a valuable therapeutic alternative when treating aortic arch lesion, in order to perform a less aggressive surgery and avoid aortic cross-clamping, circulatory assistance and high dose heparinization. Longterm follow-up of a larger number of patients is needed to assess and confirm this favorite result in order to promote this approach. Branched and fenestrated aortic stent graft may be the next approach when it is more convenient, less complicated and available as an offthe-shelf device [14]. Conclusion Although early results are promising, long-term clinical efficacy and safety have yet to be confirmed. Consent Written informed consent was obtained from the patient for publication of this Case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal. Competing interests The authors declare that they have no competing interests. Acknowledgements The authors thank Tom kuang, MD for retouching the manuscript. Authors contributions WmZ analyzed and interpreted the patient data. WZ and JQ were the major participants of the operation. All authors read and approved the final manuscript. Received: 22 January 2013 Accepted: 8 April 2013 Published: 11 April 2013 References 1. Harrington DK, Walker AS, Kaukuntla H, et al: Selective antegrade cerebral perfusion attenuates brain metabolic deficit in aortic arch surgery: a prospective randomized trial. Circulation 2004, 110(11 Suppl1):II231 II236. 2. Lee HL, Liu KH, Yang YJ, et al: Bacteroides fragilis aortic arch pseudoaneurysm: case report with review. J Cardiothorac Surg 2008, 3:29 32. 3. Marana MAI, Alonso VG, Revuelta NC, et al: Combined treatment, endovascular and surgical treatment of posttraumatic pseudoaneurysm in the aortic arch. EJVES Extra 2006, 12(9):25 29. 4. Choi BK, Lee HC, Lee HW, et al: Successful treatment of a ruptured aortic arch aneurysm using a hybrid procedure. Korean Circ J 2011, 41:469 473. 5. Sanchez MJ, Ananian CL, Berkmen T: Embolization of an aortic arch pseudoaneurysm with coils and N-Butyl-Cyanoacrylate. J Vasc Interv Radiol 2006, 17:1677 1679. 6. Yoshida RA, Kolvenbach R, Yoshida WB, et al: Total endovascular debranching of the aortic arch. Eur J Vasc Endovasc Surg 2011, 42(5):627 630. 7. Shahverdyan R, Gawenda M, Brunkwall J: Triple-barrel graft as a novel strategy to preserve supra-aortic branches in arch-tevar procedures: clinical study and systematic review. Eur J Vasc Endovasc Surg 2013, 45(1):28 35. 8. Westaby S, Katsumata T, Vaccari G: Arch and descending aortic aneurysms: influence of perfusion technique on neurological outcome. Eur J Cardiothorac Surg 1999, 15:180 185. 9. Kubota H, Endo H, Noma M, et al: Equine pericardial roll graft replacement of infected pseudoaneurysm of the aortic arch. J Cardiothorac Surg 2012, 7:45 49. 10. Malina M, Resch T, Sonesson B: EVAR and complex anatomy: an update on fenestrated and branched stent grafts. Scand J Surg 2008, 97:195 204. 11. Chuter TA, Schneider DB: Endovascular repair of the aortic arch. Perspect Vasc Surg Endovasc Ther 2007, 19:188 192. 12. Sonesson B, Resch T, Allers M, et al: Endovascular total aortic arch replacement by in situ stent graft fenestration technique. J Vasc Surg 2009, 49:1589 1591. 13. Criado FJ: Chimney grafts and bare stents: aortic branch preservation revisited. J Endovasc Ther 2007, 14:823 824.

Zhou et al. Journal of Cardiothoracic Surgery 2013, 8:80 Page 5 of 5 14. Lee KN, Lee HC, Park JS, et al: The modified chimney technique with a thoracic aortic stent graft to preserve the blood flow of the left common carotid artery for treating descending thoracic aortic aneurysm and dissection. Korean Circ J 2012, 42:360 365. 15. Greenberg RK, Clair D, Srivastava S, et al: Should patients with challenging anatomy be offered endovascular aneurysm repair? J Vasc Surg 2003, 38:990 996. 16. Allaqaband S, Jan MF, Bajwa T: The chimney graft -a simple technique for endovascular repair of complex juxtarenal abdominal aortic aneurysms in no-option patients. Catheter Cardiovasc Interv 2010, 75:1111 1115. 17. Donas KP, Pecoraro F, Bisdas T, et al: CT angiography at 24 months demonstrates durability of EVAR with the use of chimney grafts for pararenal aortic pathologies. J Endovasc Ther 2013, 20(1):1 6. doi:10.1186/1749-8090-8-80 Cite this article as: Zhou et al.: Endovascular repair of an aortic arch pseudoaneurysm with double chimney stent grafts: a case report. Journal of Cardiothoracic Surgery 2013 8:80. Submit your next manuscript to BioMed Central and take full advantage of: Convenient online submission Thorough peer review No space constraints or color figure charges Immediate publication on acceptance Inclusion in PubMed, CAS, Scopus and Google Scholar Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit