Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

Similar documents
Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Single Quadrupole Compact Mass Spectrometer for Liquid Sample

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Analytes. Sample Preparation Procedure. Introduction. Format: Sample Pre-treatment. Sample Loading. Analyte Extraction and Derivatization.

A high performance mass spec designed just for chemists

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

More structural information with MS n

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

QuickSplitTM Flow Splitters

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

2D-LC as an Automated Desalting Tool for MSD Analysis

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

HPLC. Varian Dynamax Preparative HPLC Columns

CAMAG TLC-MS INTERFACE

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Advanced in vitro exposure systems

Join the mass movement towards mass spectrometry

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

CyBio Felix Your Automated Application Starts Here

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Authors. Abstract. Introduction. Environmental

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

HI Total Alkalinity Mini Titrator for Water Analysis

Edgar Naegele. Abstract

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

HI Total Acidity Mini Titrator for Water Analysis

Agilent 1260 Infinity Analytical SFC System

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

ACE C18-AR Use the Power!

HI Total Alkalinity Mini Titrator for Water Analysis

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

Purification - Flash Chromatography

CORESTA Recommended Method No. 84

Chromatography Vacuum Ultraviolet Spectroscopy

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Agilent s LC/MS Portfolio and Applications Examples

MSQ. Hardware. Document No Revision 02 October 2003

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

QuickSplit TM Flow Splitters

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Quick Sealing with a Twist to Connect Actuation Method

Dialysis System DBB-07

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

Results of Using Re-washed Vials and Closures

Vitamin D3 and related compounds by ESI and APCI

Determination of Amantadine Residues in Chicken by LCMS-8040

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

AS Application Note 1602

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses

Key Advantages of Comprehensive Cannabis Analysis

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

FasMate Quick Connectors Industry Applications:

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

COST, PROCESS & QUALITY IMPROVEMENT

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Polymer Additive Analysis by EI and APCI

Analysis of HMF by HPLC

Lipidomic Analysis by UPLC-QTOF MS

Application Note. Author. Abstract. Introduction. Food Safety

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

SeQuant ZIC -HILIC For all who expect more...

Transcription:

Mass Directed Flash Chromatography by Biotage Biotage Dalton Mass Detectors

Why Do Companies Around the World Choose the Biotage Approach to Flash Purification? As a pioneer of automated Flash purification, Biotage counts many major companies as customers. These organizations have selected Biotage as a partner because they receive the fastest and most cost efficient route to compound purification. They enjoy purification done right the first time, every time. Here at Biotage we are committed to developing tools for a seamless workflow that gets projects to completion. Our Accelerated Chromatographic Isolation (ACI) enabled systems and SNAP Ultra flash cartridges deliver the most reliable and rapid purifications possible. Flash Purification with Mass Detection Why choose Flash Chromatography with integrated mass identification? Identification of the mass of eluting compounds as they are isolated provides the information you want, when you want it. Benefits include: Immediate identification of compounds Samples separated by mass-to-charge ratio Sample crude mixtures directly Method Cartridge SNAP Ultra C18 12g Detection Mode XIC Flowrate 12 ml/min m/z Range 100.0-300.0 (APCI) Solvent A Water XIC m/z (-)151.0, (-)179.0, (-)193.0 Solvent B Acetonitrile Baseline Correction On Lambda-all (Monitor) (Brown) Rack Type 18x150 mm Max Fraction Volume 27 ml Dispense Order S 2 Isolera Mass Directed Flash Chromatography Biotage 2017

Biotage Coupling Technologies The key to success in mass-directed flash purifications is integrating the high flow rates and broad variety of organic solvents used in flash with the low sample volumes required by mass spectrometers. To achieve this, Biotage has developed Spektra enhanced detection and Nanolink. These reliable and robust technologies simplify the day-to-day operation of Biotage Dalton systems. Industry standard switching valve Three solvent inlets for positive, negative and neutral makeup solvents Precision machined piston solvent pumps Spektra Enabling Isolation of Pure Compounds Spektra is a powerful software for flash systems, combining instrument control with extended features for flash purification. Features Baseline correction Advanced λ-all detection Preview your run in the built-in simulator PDA spectral analysis MS analysis capability through a wizard interface Automatic handling of mass spectrography parameters Allows direct mass spectrography analysis of crude mixtures Biotage Nanolink Integrating Mass Detection with Flash Purification An intelligent coupling system which ensures worry-free and reliable hyphenated operation between the flash chromatograph and mass detector. Nanolink is fully automated there s no need for manual adjustments during setup or operation. Features Eliminates flow splitter optimization Automatic sampling Automatic flow adjustment 3

m/z Range 10 2000. Supports atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) of the sample. Collect on TIC enables you to collect and fractionate based on all compounds seen by the mass detector. Industry standard direct injection port ensures rapid and precise sample analysis. Automatically switches between positive and negative ionization. A single quadrupole analyzer filters the ions according to their massto-charge ratios (m/z) and directs them into the detection system. Biotage Dalton 2000 Dalton 2000 Full mass spectral analysis capability including post-run analysis, collection based on TIC, and polarity switching during the run. Applications Mass directed purifications of all types of reaction mixtures Purification of known samples m/z Information from purification of unknown compounds Natural product analysis Quick Facts m/z Range 10 2000 Collect and fractionate based on total ion count or extracted ion signals APCI ion source (ESI optional) Full spectral analysis post run ASAP Probe for liquid and solid phase analysis External roughing pump Dalton 2000 with Biotage Dalton 2000 Mass Detector, Four flash system, Biotage Nanolink and external roughing pump. 4 Isolera Mass Directed Flash Chromatography Biotage 2017

Miniaturized mass analyzer optimized for use in flash chromatography, providing instant confirmation of the collected fraction s mass. m/z Range 80 800 m/z Small footprint, fits in a regular fume hood. Internal vacuum pumps with 30 minute pump down time. Dalton Mass Detector Dalton Miniaturized system for laboratories where space is a premium. Applications Mass directed purification of simple reaction mixtures Purification of known samples Small sample volumes Quick Facts Miniaturized design Internal roughing pump m/z Range 80 800 Collect and fractionate based on up to four masses per run Nano-ESI ion source Learn More Dalton - Flash Chromatography with Integrated Mass Identification Dalton System with Dalton Mass Detector, One flash system, and Biotage Nanolink. 5

Technical Specifications Biotage Dalton 2000 Dalton Mass Detector Dimensions (w x d x h) 28 x 56 x 66 cm 35.5 x 56 x 25 cm Weight 54 kg 32 kg Ion source APCI (ESI optional) ESI nano spray Flow rate range Flash separation at 10 100 ml/min Flash separation at 10 100 ml/min Sampling adjustment Automatic split flow interface Automatic split flow interface Acquisition modes Positive and negative ionization in parallel Selectable positive or negative ionization Detection range (m/z) 10 2000 80 800 Resolution < 0.7 FWHM m/z 0.7 ±0.1 FWHM m/z Detection accuracy ±0.1 m/z ±0.5 m/z Mass fractionation limit 4 4 Make up solvents One (pure) Three (mixtures) Nitrogen gas pressure 4.1 6.9 bar (60 100 psi), minimum 98% purity 2 6 bar (29 87 psi), minimum 99.9% purity Gas consumption 8 L/min 2.5 L/min Accessories ASAP direct probe analysis N/A Custom mass intervals Yes N/A Collect on TIC Yes N/A Automatic stop on target mass Yes N/A Post run analysis Built into software and offline Offline only Vacuum pumps Internal turbo pump, external rotary vane roughing pump Integrated turbo and foreline roughing vacuum pump Control interface Spektra Spektra User serviceable parts Heated inlet capillary with o-ring and Corona needle spraychip (chip based ESI source), vac-chip Certifications CE, TÜV, FCC CE, ctüvus 6 Isolera Mass Directed Flash Chromatography Biotage 2017

Ordering Information Description Mass Detectors Biotage Dalton 2000 Mass Detector APCI 230 VAC incl roughing pump Biotage Dalton 2000 Mass Detector APCI 115 VAC incl roughing pump Biotage Dalton 2000 Mass Detector APCI 100 VAC incl roughing pump Biotage Dalton 2000 Nanolink Isolera Dalton Nanolink Isolera Dalton Mass Detector Spektra License for Dalton 2000 Part Number DALT-2000-APCI-230V DALT-2000-APCI-115V DALT-2000-APCI-100V DALT-2000-NLINK ISO-DALT-NLINK ISO-DALT-DET DALT-2000-SW Mass Detector Accessories Dalton 2000 ASAP kit, probe, capillary UP-ASAP-SNL stand, APCI source port Dalton 2000 APCI Ion source IS-APCI-S01 Dalton 2000 ESI Ion source IS-ESI-S01 Dalton 2000 Glass capillaries for ASAP, CAP-ASAP pk 100 Vac-chip 100 413712 Spraychip 200 413711 Masscape SW for Personal Computer 413874 Vac-chip O-ring (Pack of 4) 413872 250ul gastight syringe 413710 Microfilter for make up flow (pack of 5) 413484 Microfilter holder with 2m filter 413483 (pack of 2) Needle Port (pack of 2) 413487 Splitter maintenance kit (pack of 3) 413714 Description Part Number Exterior tubing kit (without SFI tubes 413875 and solvent inlet tubes) Solvent inlet tubing with filter 413460 (pack of 3) Tubes, 20x150mm, for cleaning the 413890 vac-chip DFI, Direct Flow Interface cpl. 413743 SFI, Split Flow Interface (Includes 413741 tubing for 1ml/min split) MID 4100 Calibration kit ISO-DALT-CALIB Isolera One Isolera One, One Channel, Single Collection Bed, 200-400 nm Detector Isolera One, One Channel, Single Collection Bed, 200-800 nm UV-VIS Detector Isolera One, One Channel, Extended Collection Bed, 200-400 nm Detector Isolera One, One Channel, Extended Collection Bed, 200-800 nm UV-VIS Detector Isolera Four Isolera Four, Four Channels, Single Collection Bed, 200-400 nm Detector Isolera Four, Four Channels, Single Collection Bed, 200-800 nm UV-VIS Detector Isolera Four, Four Channels, Extended Collection Bed, 200-400 nm Detector Isolera Four, Four Channels, Extended Collection Bed, 200-800 nm UV-VIS Detector ISO-1SV ISO-1SW ISO-1EV ISO-1EW ISO-4SV ISO-4SW ISO-4EV ISO-4EW 7

Title Truncated if Neccessary... Page 8 Your Complete Partner for Effective Chemistry Biotage is a worldwide supplier of instruments and accessories designed to facilitate the work of laboratory and process chemists. With our deep knowledge of the industry, academic contacts and in-house R&D teams, we can deliver the best solutions to your challenges. We take great pride in our flexibility and ability to meet our customer s individual needs. With strong foundations in both analytical, organic and process chemistry, we can offer the widest range of solutions available on the market. EUROPE NORTH & LATIN AMERICA Main Office: +46 18 565900 Main Office: +1 704 654 4900 Toll Free: +800 18 565710 Toll Free: +1 800 446 4752 Fax: +46 18 591922 Fax: +1 704 654 4917 Order Tel: +46 18 565710 Order Tel: +1 704 654 4900 Order Fax: +46 18 565705 Order Fax: +1 434 296 8217 order@biotage.com ordermailbox@biotage.com Support Tel: +46 18 56 59 11 Support Tel: +1 800 446 4752 Support Fax: + 46 18 56 57 11 Outside US: +1 704 654 4900 eu-1-pointsupport@biotage.com us-1-pointsupport@biotage.com JAPAN Tel: +81 3 5627 3123 Fax: +81 3 5627 3121 jp_order@biotage.com jp-1-pointsupport@biotage.com CHINA Tel: +86 21 2898 6655 Fax: +86 21 2898 6153 cn_order@biotage.com cn-1-pointsupport@biotage.com KOREA Tel: + 82 31 706 8500 Fax:+ 82 31 706 8510 korea_info@biotage.com kr-1-pointsupport@biotage.com Distributors in other regions are listed on www.biotage.com Part Number: PPS450 2017 Biotage. All rights reserved. No material may be reproduced or published without the written permission of Biotage. Information in this document is subject to change without notice and does not represent any commitment from Biotage. E&OE. A list of all trademarks owned by Biotage AB is available at www.biotage.com/legal. Other product and company names mentioned herein may be trademarks or registered trademarks and/or service marks of their respective owners, and are used only for explanation and to the owners benefit, without intent to infringe. Biotage 2017