Routine OCT and UBM of the anterior segment

Similar documents
UBM and glaucoma: diagnosis and follow-up of plateau iris. M. Puech

he Role of UBM and Anterior Segment OCT in Anterior Segment Imaging

INTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany

Corporate Medical Policy

3/16/2018. Ultrasound Biomicroscopy in Glaucoma By Ahmed Salah Abdel Rehim. Prof. of Ophthalmology Al-Azhar University

Ultrasound Biomicroscopy & Glaucoma Care

Ultrasound Biomicroscopy Noel Moniz, MS L.F. Hospital and Reserach Centre, Angamaly

Populations Interventions Comparators Outcomes Individuals: Who are being evaluated for angleclosure

03/04/2015. LOC Talk Anterior Chamber & Gonioscopy 1st April Methods of Assessing Anterior Chamber Depth (and angle width) Outline

5/18/2014. Fundamentals of Gonioscopy Workshop Aaron McNulty, OD, FAAO Walt Whitley, OD, MBA, FAAO

Management of Angle Closure Glaucoma Hospital Authority Convention 18 May 2015

Anterior segment imaging

Role of Ultrasound Biomicroscopy in the Management of Retinoblastoma

Structural changes of the anterior chamber following cataract surgery during infancy

A Study to Reach the Proper Measurement of the White to White Diameter Using both the Caliper and IOL Master for ICL Suitable Size

SOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only

Chronicity. Narrow Minded. Course Outline. Acute angle closure. Subacute angle closure. Classification of Angle Closure 5/19/2014

Clinical Study Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology

_ Assessment of the anterior chamber. Review of anatomy of the angle

Cornea/Anterior Segment OCT. User Experience

Clinical Study Age and Positional Effect on the Anterior Chamber Angle: Assessment by Ultrasound Biomicroscopy

Systems for Anterior Chamber Angle Evaluation 長庚紀念醫院青光眼科吳秀琛

Anterior Segment Optical Coherence Tomography for the Quantitative Evaluation of the Anterior Segment Following Boston Keratoprosthesis

Primary Angle Closure Glaucoma

Are traditional assessments a waste of time? NZAO 2015

Optical Coherence Tomography (OCT) of the Anterior Eye Segment

Medical Policy. MP Optical Coherence Tomography of the Anterior Eye Segment

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Gonioscopy and Slit Lamp Exam for the Glaucoma Suspect. Disclosure GONIOSCOPY: Gonioscopy Why?? What should I look for? GONIOSCOPY

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Clinical and Anterior Segment Anatomical Features in Primary Angle Closure Subgroups Based on Configurations of Iris Root Insertion

NEW YORK UNIVERSITY SCHOOL OF MEDICINE DEPARTMENT OF OPHTHALMOLOGY EDUCATIONAL OBJECTIVES AND GOALS

Description. Section: Other Effective Date: July 15, 2015 Subsection: Vision Original Policy Date: June 7, 2012 Subject: Page: 1 of 11

Ultrasound Biomicroscopic Changes of the Angle after Laser Iridotomy and Primary Trabeculectomy in Primary Angle Closure Glaucoma Patients

Anterior segment imaging

2/26/2017. Sameh Galal. M.D, FRCS Glasgow. Lecturer of Ophthalmology Research Institute of Ophthalmology

INFANTILE NEPHROPATHIC cystinosis

Downloaded from:

Understanding Angle Closure

Nature and Science 2016;14(9)

9/25/2017 CASE. 67 years old On 2 topical meds since 3 years. Rx: +3.0 RE LE

4/20/17, 04/19/18 POLICY NUMBER:

Ultrasound Biomicroscopy Study of Anterior Segment Measurements in Normal Eyes in a Tertiary Care Rural Hospital of SPRR Nellore District

Technicians & Nurses Program

Optical Coherence Tomography (OCT) of the Anterior Eye Segment

NIH Public Access Author Manuscript Cornea. Author manuscript; available in PMC 2014 May 29.

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

The Anterior Segment & Glaucoma Visual Recognition & Interpretation of Clinical Signs

Ciliary body enlargement and cyst formation in uveitis

SECONDARY CAPSULOTOMY USING THE FEMTOSECOND LASER. Surendra Basti, MD Northwestern University Feinberg School of Medicine, Chicago, IL

Glaucoma. How is Glaucoma Diagnosed? Glaucoma Testing

Megalocornea is a non-progressive, uniformly

Ultrasound biomicroscopy: role in diagnosis and management in 130 consecutive patients evaluated for anterior segment tumours

Interpretation of corneal tomography

Primary angle closure (PAC) Pathogenesis: Pathogenesis 12/2/2016. Ying Han, MD, PhD Associate Professor of Ophthalmology Glaucoma Service, UCSF

Ocular Studies of EMF Exposure at the MMW M. Kojima 1,2,3), Y. Suzuki 4)

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

DNB QUESTIONS 2014 PAPER 1. b) What are the Clinical Conditions in Which Nystagmus is Seen? c) Management of Nystagmus.

Sinus trabeculectomy. Preliminary results of IOO operations

The World s fastest OCT. As simple as pressing. the start button

Citation BMC Ophthalmology, 2016, v. 16, article no. 64

OPHTHALMOLOGY AND ULTRASOUND

Ultrasound biomicroscopic measurement of anterior chamber angle in premature infants

Glaucoma: Diagnostic Modalities

Recurrent intraocular hemorrhage secondary to cataract wound neovascularization (Swan Syndrome)

GLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES

Wallace L.M. Alward, M.D. Frederick C. Blodi Chair Department of Ophthalmology

Case Study. Monocular Malignant Melanoma

Effects of diurnal, lighting, and angle-ofincidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics

Increased iris thickness and association with primary angle closure glaucoma

Revitalization of the Anterior Segment: Corneal Transplantation and Secondary Lens Repair

Ultrasound Biomicroscopy Dark Room Provocative Testing: A Quantitative Method for Estimating Anterior Chamber Angle Width

THE CHRONIC GLAUCOMAS

3/23/2016. Diagnostic Services Taylor Pannell CRA, OCT-C. Services Available. Important info for the Tech to know. Visual Fields

Ultrasound Evaluation of the Posterior Segment of the Eye A Ready Reckoner

Gonioscopy and 3-Mirror Retinal Evaluation Workshop Edeline Lu, O.D., FAAO Benedicte Gonzalez, O.D., MPH, FAAO Tina Zheng, O.D.

Local Coverage Determination (LCD): Scanning Computerized Ophthalmic Diagnostic Imaging (SCODI) (L34431)

( Number: Policy *Please see amendment for Pennsylvania Medicaid at the end

Clinical Commissioning Policy Proposition: Keratoprosthesis for corneal blindness

Diagnosis and Therapy in Ophthalmology Hand-held optical coherence tomography imaging in children with anterior segment dysgenesis

Intrascleral-fixated intraocular lenses for aphakic correction in the absence of capsular support

What Is O.C.T. and Why Should I Give A Rip? OCT & Me How Optical Coherence Tomography Changed the Life of a Small Town Optometrist 5/19/2014

Pseudophakic angle-closure from a Soemmering ring

Optical Coherence Tomography (OCT) in Uveitis Piergiorgio Neri, BMedSc, MD, PhD Head Ocular Immunology Unit

Meet Libby. Corneal Dysgenesis, Degeneration, and Dystrophies Definitions. Dr. Victor Malinovsky

Anterior segment imaging in angle-closure disease

Optical Coherence Tomography (OCT) of the Anterior Eye Segment

Assisting in Ophthalmology. Copyright 2011, 2007, 2003, 1999 by Saunders, an imprint of Elsevier Inc. All rights reserved.

Ibopamine is a poorly selective dopaminergic drug that is

Ophthalmology. Cataract Surgery and IOL Implants

Anterior Chamber Angle: Assessment and Anomalies

Nate Lighthizer, O.D., F.A.A.O. Assistant Professor, NSUOCO Assistant Dean, Clinical Care Services Director of CE Chief of Specialty Care Clinics

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Late-onset secondary pigmentary glaucoma following foldable intraocular lenses implantation in the ciliary sulcus: a long-term follow-up study

Preliminary Programme

Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy

Relationship between limbal incisions. angle. and the structures of the anterior chamber

Distinction layer by layer. HRT II Rostock Cornea Module

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

The Sense Organs 10/13/2016. The Human Eye. 1. Sclera 2. Choroid 3. Retina. The eye is made up of three layers:

Transcription:

Reprinted from No. 160 december 2012 Volume 17 Routine OCT and UBM of the anterior segment Michel Puech ISSN : 1274-5243 R e p r i n t e d w i t h t h e s u p p o r t o f t h e L a b o r a t o r y Q u a n t e l M é d i c a l This report was drafted under the sole responsibility of the coordinator, the authors, and the managing editor, who vouch for the objectivity of this publication JBH santé F r o m i n f o r m a t i o n t o s p e c i a l i s t t r a i n i n g

D o s s i e r I M A G I N G I N O P H T H A L M O L O G Y Routine OCT and UBM of the anterior segment Michel Puech - Centre Explore Vision, Paris Centre d Exploration de la Vision, Rueil-Malmaison CHNO des Quinze-Vingts. Dept. of Prof. Laroche, Paris Highlights OCT imaging performs well for corneal imaging OCT imaging performs well for anterior segment measurements UBM imaging performs well for visualising the ciliary body and identifying the risk of plateau iris mechanism Introduction Exploration of the anterior segment by OCT and UBM usefully complements slit lamp examination. The particular feature of OCT and UBM instruments is their ability to provide sectional images of the cornea and anterior segment covering either a delimited area or the entire anterior segment. These imaging systems allow the measurement of different anatomical values and distances. Another advantage they offer is access to structures that are difficult to see with the slit lamp, such as the iridocorneal angle or ciliary processes. Greater resolution of imaging systems and their wider availability in ophthalmology centres offer practitioners not only an appreciable additional diagnostic aid, but also a didactic feature for patients. Key words OCT UBM Sectional imaging of anterior segment Tissue penetration Technical principles OCT instruments The exploration of the anterior segment by OCT can be performed with two different types of instruments: OCT instruments designed for the exploration of the anterior segment with a specific wavelength of about 1300 nm: this wavelength allows a better penetration through the different iris tissues. These instruments can also provide sectional images of the entire anterior segment. However, this method involves the use of an infrared beam whose penetration is countered by the most highly pigmented tissues such as the iris: a good visualisation of the ciliary processes is thus impossible when the iris is dark-coloured. OCT instruments designed for macular exploration, which use wavelengths of about 850 nm, along with an evolution of OCT towards the use of spectral domain systems, allowing faster acquisition and better resolution than those obtained with time domain instruments. Recent instruments allow the OCT beam to be focused on the anterior segment with a very high analytical resolution, but still with limited penetration owing to the wavelength used and a limited acquisition window, which most often precludes a complete sectional image of the entire anterior segment. 2 Reprinted from No. 160 - Volume 17 - december 2012 - RéfleXions Ophtalmologiques

Routine OCT and UBM of the anterior segment UBM instruments Very high frequency ultrasonography applied to the anterior segment was described in the 1990s by Charles Pavlin, with the first demonstration of the utility of ultrasound biomicroscopy (UBM) instruments for glaucoma and iridociliary tumours. The principle of these instruments is to use very high-frequency ultrasonographic probes (higher than 20 MHz) with focusing between 10 and 12 mm so as to obtain better resolution on the anterior segment and the iris. The resolution of UBM instruments is lower than that of recent OCT devices, but ultrasonography offers the advantage of a very high power of penetration through opaque tissues with, for example, a very good visualisation of ciliary processes, irrespective of iris pigmentation. Routine use of OCT and UBM imaging The use of these two types of imaging instruments for the anterior segment is optimised by using the very high resolution of weakly penetrating OCT when focusing on the cornea or the iridocorneal angle, and UBM preferentially for the analysis of structures lying behind the iris. Corneal imaging For corneal imaging, OCT outperforms UBM owing to its very high resolution, spectral domain OCT allowing the visualisation of different layers of the cornea and the specific identification of the reflectivity disturbances than can arise in corneal disorders, refractive surgery treatments or corneal grafts and trauma. It is thus possible to relocate the section plane of a Lasik procedure even several years post-operatively. Measurement of the corneal section depth and the thickness of the residual stroma is an important factor in deciding on further treatment for an insufficient refractive effect (Figure 1). Determination of the depth of certain opacities also allows the guidance of ablative treatments intended to improve corneal transparency. Anterior segment imaging and phakic implants The exploration of the anterior segment by OCT or UBM allows the analysis of phakic implant surgery techniques. For anterior chamber implants, both OCT and UBM instruments allow the measurements of safe distances between the optical implant and the cornea, or between the optical implant and the lens (Figure 2). The analysis of feet positioning in the iridocorneal angle offers another advantage in cases of pupillary ovalisation. For posterior chamber implants, only UBM imaging gives a good visualisation of the optical implant behind the iris and the position of the implant feet. In some cases, this examination can reveal evidence of implant oversizing or mispositioning. Figure 1 : Very high resolution OCT sectional image (spectral domain) showing a Lasik microkeratome section, one year after surgery: the depth of the section and the thickness of the residual stroma can be measured to decide on any further additional treatment. Figure 2 : Sectional image of an anterior segment (OCT Visante, Zeiss) in a patient after phakic implant surgery of the anterior chamber with safe distance measurements between the implant and the cornea and between the implant and the anterior lens capsule. Reprinted from No. 160 - Volume 17 - december 2012 - RéfleXions Ophtalmologiques 3

Routine OCT and UBM of the anterior segment Anterior segment imaging and glaucoma The first applications of sectional imaging of the iridocorneal angle were described with UBM. The advent of recent OCT broadens our exploratory scope. Narrow-angle The main indications are linked to the determination of glaucoma risk by angle closure with a very good visualisation of the scleral spur, which serves as a stable anatomical reference point relative to the iris and ciliary body, and whose shape can vary according to the pupillary diameter or accommodation. The analysis of a narrow iridocorneal angle and risk of glaucoma by angle closure can be carried out by either OCT or UBM, in light- or dark-adapted conditions to observe the behaviour of the angle with a secluded pupil comparable to our patients night-time situation (Figure 3). Angle measurement The current systems allow the measurement of either the iridocorneal angle opening or the peripheral depth of the anterior chamber (AOD 500 or AOD 750, which represents the angle opening distance at 500 microns or 750 microns from the scleral spur). Open-angle Open-angle glaucoma can also benefit from imaging to show, for example, inversion of iris curvature in cases of pigmentary glaucoma. After surgery for chronic open-angle glaucoma, the site of filtration surgery (trabeculectomy or deep sclerectomy) can be analysed by OCT or UBM to observe, in cases of dysfunction, the mechanism of reduced filtration: apposition of the iris root, collapsed scleral flap with no decompression chamber, or fibrosed conjunctival filtering bleb. Figure 3 : UBM sectional image of a narrow iridocorneal angle that appears closed in dark-adapted conditions. In this patient, the ciliary body is located behind the scleral spur, showing the absence of plateau iris mechanism. Measurement of crystalline lens rise The position of the anterior lens capsule relative to the straight line connecting the two iridocorneal angles determines the crystalline lens rise, which is used to assess the extent of the lens factor in the angle closure mechanism (Figure 4). Plateau iris The limit of OCT is often set by the pigmentation of the ciliary body and the root of the iris, which restricts the analysis of the ciliary body, whereas UBM gives a very good visualisation of the position and dynamics of the ciliary processes. The routine use of UBM has found an appreciable proportion of patients presenting an anterior position of the ciliary processes. This picture, associated with a closed angle and no ciliary sulcus, forms the conditions for closed-angle glaucoma with a plateau iris mechanism (Figure 5). In cases of iris root double hump sign diagnosed by gonioscopy, exploration by UBM provides ver y useful additional analytical data to support a therapeutic decision. Figure 4 : Whole anterior segment sectional images obtained by UBM or OCT provide a measurement of crystalline lens rise: here measured at 1300 microns by Visante OCT, attesting a strong lens factor in the risk of angle closure. Figure 5 : UBM sectional image of a closed angle with plateau iris mechanism: the ciliary body is located in front of the scleral spur. 4 Reprinted from No. 160 - Volume 17 - december 2012 - RéfleXions Ophtalmologiques

Routine OCT and UBM of the anterior segment Anterior segment imaging and tumour Exploration of the anterior segment with OCT and UBM instruments is another field of application for monitoring tumours of the iris and ciliary body. Here the OCT images provide a first approach, pointing to an iris relief or filling of the iridocorneal angle, but the better penetration of UBM makes it indispensable for this application. Classical situations include diagnoses of iris vaulting, where both OCT and UBM instruments can identify iris relief, but where the appreciably better penetration of the UBM allows the presence of iridociliary cysts to be differentiated from solid lesions of the nevus or melanoma type. Recourse to UBM to measure iridociliary tumours enhances the clinical follow-up of patients with diagnosis and conservative treatment of melanoma (Figure 6). Anterior segment imaging and trauma In cases of violent trauma with marked hyphema, exploration by UBM offers the possibility of a clinical appraisal of the anterior segment, with visualisation of the different anatomical structures to seek anomalies of the iridocorneal angle, such as traumatic angle recession or ciliary detachments. Traumatic cataracts and lens subluxations can benefit from a clinical appraisal to support a therapeutic decision. Conclusion Progress in image quality through an appreciable improvement in the resolution of OCT and high-frequency ultrasonography instruments, associated with greater availability of these different devices, lends ever greater scope to anterior segment imaging in routine practice. This new approach to the anterior segment, which complements the slit lamp examination, Figure 6 : UBM meridian section of an iridociliary melanoma allowing a follow-up after conservative treatment by measuring the main dimensions: length, width and thickness. provides further clinical information not only at the diagnosis stage, but also throughout medical or post-therapeutic follow-up. Iridocorneal angle imaging can be performed with both OCT and UBM, with the recently improved resolution of the OCT instruments, but the better penetration of UBM allows an analysis of retroiridian structures. In the current state of technology, the advantages of OCT for exploring the anterior segment are preponderant for sectional imaging of the cornea, for the different measurements of the anterior segment and for the follow-up of phakic anterior chamber implants. UBM remains the method of choice for the diagnosis of angle closure by plateau iris mechanism, for the monitoring of posterior chamber phakic implants and for the diagnosis and follow-up of iridociliary tumours. Conflicts of interest: none REFERENCES Pavlin CJ, Harasiewicz K, Foster FS-Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes [see comments],1992, Am J Ophthalmol 113(4): 381-9. Pavlin CJ, Harasiewicz K, Sherar MD, Foster FS. Clinical use of ultrasound biomicroscopy. Ophthalmology. 1991 Mar;98(3):287-95. Pavlin CJ, Foster FS. Reinstein DZ, Srivannaboon S, Archer TJ, Silverman RH, et all Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part I: quantifying individual risk. J Refract Surg. 2006 Nov;22(9):851-60. Baïkoff G, Bourgeon G, Jodai HJ,et all. Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion. J Cataract Refract Surg. 2005 Apr;31(4):674-80. Reinstein DZ, Archer TJ, Silverman RH, et all, Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound. J Refract Surg. 2009 Feb;25(2):185-94. Zhou SY, Wang CX, Cai XY, Huang D, Liu YZ.Optical Coherence Tomography and Ultrasound Biomicroscopy Imaging of Opaque Corneas. : Cornea. 2012 Oct 15. Reprinted from No. 160 - Volume 17 - december 2012 - RéfleXions Ophtalmologiques 5