Straumann Screw-retained Prosthetics

Similar documents
Straumann Dental System Indication-based prosthetic workflow. Technical Information

» For multi-unit restorations -

Stock Prosthetic Guide 2014

Ø Smaller and Stronger.

Straumann Variobase for Bridge/Bar

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

Ø Smaller and Stronger.

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

Bridging the Gap Between Original and Multi-Platform Systems.

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

BONE LEVEL ABUTMENTS. on4. multi-unit

Product Catalog 2017/2018. Straumann International Edition

Intraoral Library INSTRUCTIONS FOR USE DYNAMIC ABUTMENT SOLUTIONS LIBRARY INST_EXOCAD_INTRAORAL_01_2017_01_EN. scan

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

3D-Guide. Scanbody for high-precision implant position transfer INTERNATIONAL PATENT BENEFITS: APPLICATION: TECHNICAL DETAILS:

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

» Prosthetic Options by MEDENTiKA «

For technical assistance: Tel Working time: 8.30 am pm

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Basic information on. Fixed edentulous solutions Treatment guide

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

TRINON. Index. Index. Overview Page 4. Catalogue

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

The solution for the edentulous patients. Prosthetics compatibillity 3i Multi-unit Abutment Regular Abutment (MegaGen)

isy indications and techniques

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

N-SERIES. compatible to: Straumann / SynOcta 32 NT-TRADING CATALOGUE PLATFORM 3,5 mm NN 4,8 mm RN 6,5 mm WN TITANIUM BASE SCAN BODY 3D-GUIDE

24 About us Sincerely. Content SCREW SELECTION GUIDE

Multi-Unit Abutment Guide

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

User Manual Complete Prosthetic Kit (CPK)

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

Restoring Straumann implants. with Locator abutments.

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

What s New. CARES Visual 12.1

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

INTERNAL HEXAGON PROSTHETIC OPTIONS. MIS Corporation. All Rights Reserved.

S-SERIES. compatible to: DENTSPLY Implants / Astra Tech Implant System OsseoSpeed TX. PLATFORM 3,5 / 4,0 mm 4,5 / 5,0 mm TITANIUM BASE

More than a Ti-base. Your trusted link between implant and restoration. Straumann Variobase C. Variobase for CEREC becomes Variobase C

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

NobelEsthetics. Introduction page 4. Temporary implant restorations page 6. Solutions for existing teeth page 14. Final implant restorations page 26

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

US Implant System 2013 PROSTHETIC PROCEDURE

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

TruAbutment Digital Solutions

The intelligent system.

INTRODUCTION. Why Choose Cortex Prosthetics?

NEW IMPLANT PLATFORMS AVAILABLE NewJANUARY 2018

Leading material offering and application range. Straumann CARES CADCAM

T-SERIES. compatible to: DENTSPLY Implants / Xive. PLATFORM 3,4 mm 3,8 mm 4,5 mm 5,5 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG IMPLANT PICK-UP

Implant Phase Flow Chart

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

R-SERIES. compatible to: Zimmer Dental / Tapered Screw-Vent 36 NT-TRADING CATALOGUE PLATFORM 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE

Type 1. Type 2. Straumann Tissue Level. The N-Series abutments are compatible with» N-SERIES «

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Basic information on. screw-retained hybrid restorations

Legacy Prosthetic Catalog

SimpleLine II Surgical / Prosthesis Manual

NobelReplace Conical Connection Product overview

E-SERIES. compatible to: Nobel Biocare / Replace Select. PLATFORM 3,5 mm NP 4,3 mm RP 5,0 mm WP 6,0 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG

prosthetic technique manual

surgical and prosthetic options & impression technique overview

Product Information. Straumann Novaloc. A reliable connection that endures.

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

WHERE CREATIVITY MEETS TECHNOLOGY E CREATECH EXCELLENCE. State-of-the-art technology for your prostheses

Restore your patients quality of life. Solutions for all edentulous indications

Straumann Dental Implant System. Fax Order Form Collection.*

More than Abutments. catalogue

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

CAD/CAM Prosthetic Solutions

introduction to BioHorizons prosthetics

/NobelReplace Ø4.3mm. /NobelReplace Ø3.5mm

cement-retained single crowns using cementable abutments

SwissPlant Prosthetic Catalog. SwissPlant

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

HEXAGON Implant System

Quick start Prosthetics

SuperLine & Implantium Surgical / Prosthesis Manual

OCCLUSALLY SCREW-RETAINED

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

NobelActive Product overview

Straumann synocta Prosthetic System Basic Information. Technical Information

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

Ankylos. Product Catalog

MiNi Overdenture Fixture

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

Transcription:

Straumann Screw-retained Prosthetics

Straumann Screw-retained Abutments Straumann Screw-retained abutments Indication and product features Abutments for fixed screw-retained restorations; for multi-unit and single-unit restorations Available in different gingiva heights Available with different angulations Compatible with Straumann Bone Level Implants (for NC / RC) Round-off edges and steep abutment connector angle of 22 Same abutment connector geometry for all platforms to allow small component portfolio Design allows abutment-level impression Consistent Straumann colour coding

Abutment technical features Requirements for tilted implant type restorations Short connector H: 1.8mm Flat, Wide shoulder 0.3mm Wide angles 17, 30, 0 Multiple heights mm, 4mm, 1mm 1 2 BL diameters 4.6mm, 3.5mm 2 3 1 only available for straight abutments // 2 diameter 3.5mm abutments only available in straight version

Abutment technical features Requirements for tilted implant type restorations Same connector design Allows limited coping portfolio Round-off edges 45 Steep abutment angle 22 Allows multi-unit and single unit restorations CrossFit connection For easy positioning 4

Abutment connector new features (example RC abutment, straight & angled, GH mm) New angulations: 17 & 30 Reduced abutment dimension Same connector geometry limited coping portfolio Connector allows multi-unit as well as single-unit restorations 4.6mm 17 30 1mm 1mm <2mm mm Multibase, straight Screw-retained abutment, straight Multibase, angled 25 Screw-retained abutment, angled 17 Screw-retained abutment, angled 30

Gingiva heights (angled abutments) NC/RC Ø4.6mm 17 30 4mm mm Screws (included in abutments and copings) Basal screw NC #025.0002 RC #025.0002 Occlusal screw #023.4763 6

Gingiva heights (straight abutments) NC Ø3.5mm NC/RC Ø4.6mm 4mm mm 1mm Screws (included in abutments and copings) Basal screw GH 1: #023.4749 GH 2: #023.4750 GH 3: #023.4760 Occlusal screw #023.4763 7 1 indication limitation: single unit only anterior (icentral/lateral incisors), crown/bridge incisors, canines and premolars

Limited Indications for NC 0º Ø3.5 & Ø4.6, GH 1.0mm Abutment 0 17 30 0 17 30 Connection NC NC RC D 3.5 4.6 4.6 Typ A B A B A B A B GH 1.0 -- -- -- -- -- -- -- -- 4.0 canines incisors canines incisors premolars premolars molars Indication of NC Implants molars Indication of NC Implants wisdom teeth Crown wisdom teeth Bar / Bridge

Copings Components for Straumann Screw-retained abutments Indication and product features Immediate temporization possible with Titanium copings Titanium copings allow production of temporary restoration to be placed in patient s mouth immediately Convert existing patient s denture into temporary restoration Polymer copings for burn-out techniques Bar copings for conventional final prosthesis

Technical features: Abutment connector design and copings Connector Geometry Straight and angled abutments with same abutment connector geometry limited coping portfolio Ø 3.5mm Ø 4.6mm NC NC RC * * * * Same copings for straight / angled abutments D 4.6mm Same copings for straight abutments D 3.5mm Multi-unit/single unit restoration Engaging/non-engaging feature integrated in copings Total 5 copings *available as engaging and nonengaging Engaging Total 5 copings *available as engaging and nonengaging Non-Engaging 10

Technical features: Abutment connector design and copings Compared to the current Multibase coping portfolio the new coping portfolio for Straumann Screw-retained abutment is limited thanks to the new connector geometry RC Multibase RC Screw-retained abutment Straight, Ø4.5mm Angled, Ø4.0mm Straight, Ø4.6mm Angled, Ø4.6mm Non-engaging engaging 11

Technical Feature: Screw-in-screw concept Straight abutments have a screw-inscrew-concept: The occlusal screw is screwed into the basal screw For reduced height of the restoration Both screws to be used with the SCS screwdriver #023.4763 12

Impression Taking Components for Straumann Screw-retained abutments Indication and product features Impression taking on abutment-level: either traditional or via scanbodies Traditional impression-taking On abutment-level Open tray or closed tray For both diameters: Ø3.5 / Ø4.6mm Reflects existing Straumann colour coding Scanbodies Base for digitally processing CARES hybrid bars and wrap around bars (via dental models) For scanning on abutment-level Internal geometry reflects Screw-retained abutment design For both diameters: Ø3.5 / Ø4.6mm Material PEEK

New Impression components compared to Multibase 025.4242, open tray impression post same design, same material same procedure 025.2244, open tray impression post 025.4241-04, closed tray impression post, plastic post to be snapped onto abutment 025.2246, closed tray impression post, Metal post screwed onto abutment, plastic positioning cap

Bar copings - dimensions Ø 3.5mm Ø 4.6mm NC NC RC SKU: 023.2750 SKU: 023.4752 (same for NC and RC 4.6mm) 15

Protective caps - dimensions Ø 3.5mm Ø 4.6mm NC NC RC SKU: 024.2323 /.2324 /.2325 (available in V4) SKU: 024.4323 /.4324 /.4325 (same for NC and RC 4.6mm) 3 different heights: 5mm / 6.5mm / 8mm 3 different heights: 5.1mm / 6.6mm / 8.1mm 16

Comparison Nobel Biocare Multi-unit Abutment and Straumann Screw-retained Abutment Straumann Nobel Biocare Straight Angled Straight Angled Abutment Design Implant Diameters BL: NC Ø 3.5mm NC Ø 4.6mm RC Ø 4.6mm BL: NC Ø 3.5mm NC Ø 4.6mm RC Ø 4.6mm Different abutments for: - external connection (Branemark / Nobel Speedy Groovy) - Internal conical connection (Nobel Active / Replace) - Internal Three-Part connection (Nobel Replace / Replace Select / Nobel Speedy Replace) Angulations 0 17 / 30 0 17 / 30 Gingiva Heights 1,, 4mm, 4mm 1-5mm depending on implant type Auxiliary Portfolio Abutment Connector Design Due to abutment connector design, same copings for straight and angled abutments 2-5mm depending on implant type Different copings for angled and straight abutments Connector Height 1.8mm 1.8mm <2mm <2mm 17 Abutment Connector Angle 22 22, plus round off edges 45 Shoulder Flat and 0.3mm wide Flat and 0.3mm wide flat flat

Who is who in the new Straumann Screw-retained abutment portfolio Multibase NC Ø3.5 NC Ø4.0 RC Ø4.0 NC Ø4.5 RC Ø4.5 RC Ø6.5 0 25, Type A/B 25, Type A/B 0 0 0 Gingiva Heights 1 4 Screwretained Abutment -- -- -- -- NC Ø3.5 NC Ø4.6 RC Ø4.6 NC Ø4.6 RC Ø4.6 1 4 1 4 1 4 0 17 / 30 A/B 17 / 30 A/B 0 0 1 4 -- 4 Copings 18 NC Ø3.5 NC/RC Ø4.6, due to the new abutment connector geometry, the new copings are not compatible with Multibase abutments -- 4 1 4 1 4

Who is who in the new Straumann Screw-retained abutment portfolio - Copings Multibase NC Ø3.5 NC Ø4.0 RC Ø4.0 NC Ø4.5 RC Ø4.5 RC Ø6.5 Copings 0 25, Type A/B 25, Type A/B 0 0 0 Bridge Gold Bridge Polymer Bar Gold Bar - Polymer Screwretained Abutment 023.2731 023.2734 023.2732 023.2736 023.2701 023.2704 023.2702 023.2706 023.4701 023.4704 023.4702 023.4706 023.2741 023.2744 023.2742 023.2746 023.4741 023.4744 023.4742 023.4746 NC Ø3.5 NC Ø4.6 RC Ø4.6 NC Ø4.6 RC Ø4.6 023.4761 023.4764 023.4762 023.4766 0 17 / 30 A/B 17 / 30 A/B 0 0 Copings Titanium engaging Titanium non-eng. Titanium 19 Bar Polymer engaging Polymer non-eng. 023.2747 023.2749 023.2750 023.2748 023.2755 023.4747 023.4751 023.4752 023.4748 023.2755

Product Portfolio for new Screw-retained Prosthetics Planning Guide 20

www.straumann.com