The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

Similar documents
The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

Eclipse Evoked Potential System. 10 reasons to choose

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

A full product range for your every need. World leading diagnostic solutions

Neuro-Audio Version 2010

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

AD629 The true hybrid

AC40. The true clinical. hybrid

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

Protocol for Fast, Efficient Audiogram Prediction using Electrophysiology. Sponsored By

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

by Maico Diagnostics

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Handheld OAE-Tympanometry Combination System

Reliable, flexible & precise

The Level Specific CE-Chirp

A full product range for your every need. World leading diagnostic solutions

NEURO-AUDIO. Auditory EP (ABR, ASSR, ECochG), PTA and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

ERO SCAN. Otoacoustic Emission Testing

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

ABR Screener Excellence in Newborn Hearing Screening

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

III. Comprehensive. Efficient. Auditory EP Testing

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

Additional Information Eclipse

ABR Screener Excellence in Newborn Hearing Screening

myaudiometer. It s familiar, and it s so much

Additional Information Eclipse

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

the truly automated all-in-one hearing screener

The following describes general use of ELIOS device

UPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS

NEURO-AUDIO. Auditory EP (ABR, VEMP, ASSR, ECochG) and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

User Manual. Neuro-Audio.NET UM ( )

The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss

Unlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

(Otoacoustic Emissions and Automated ABR)

Experience the power of integration

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

Contents. Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface

Audiological Diagnosis after Newborn Screening

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

Auditory Steady-State Response (ASSR): A Beginner's Guide by Douglas L. Beck, AuD, David P. Speidel, MS, Michelle Petrak, PhD

FALSE POSITIVE DP GRAMS

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

Quick Guide - eabr with Eclipse

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

Instructions for Use - EN Eclipse

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

Operation Manual. The Eclipse Platform EP15, EP25, TEOAE25, DPOAE20, ABRIS, ASSR. Introduction. The Eclipse Hardware and Software Installation

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Additional Information Titan

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

Audiology Core Competencies Worksheet

SLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;

Simultaneous multiple stimulation of the auditory steadystate response (ASSR)

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

Oscilla - excellence since 1960

ATMOS 360 diagnostics. Complete solution.

MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

Toward Extending Auditory Steady-State Response (ASSR) Testing to Longer-Latency Equivalent Potentials

AUTOMATED AUDITORY BRAINSTEM RESPONSE INFORMATION AND GUIDELINES FOR SCREENING HEARING IN BABIES

The true hybrid Stand alone & PC-based audiometry in one box

Neurosurgical Review. CE-Chirp ABR in cerebellopontine angle surgery neuromonitoring: technical assessment in four cases.

CS Introducing the CS 1600 Intraoral Camera Revolutionary technology. Superior workflow.

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

3. How does your state collect these results? (Check all that apply.) collecting this information.

Thresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan

Auditory Assessment Based On EEG

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

OtoAcoustic Emissions (OAE s)

Tele-audiology. Deviceware. Integration with Resonance Portable Diagnostic Devices. White Paper (v1.1)

The true hybrid Stand alone & PC-based audiometry in one box

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Audiological Manual. Ponto TM The Bone Anchored Hearing System

OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS

Transcription:

The Eclipse High quality evoked potentials at your command AEP, ASSR, & OAE testing on one dedicated platform

Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile platform. It is designed to fit seamlessly into your everyday workflow and to offer complete reliability and perfect results. Have it your way The Goal: To achieve reliable test data to screen or diagnose patients accurately and efficiently. Whatever your challenge may be, the Eclipse hardware platform does just that, enabling you to focus on the job at hand with the assistance of dedicated software modules for all facets of auditory evoked potentials and otoacoustic emissions. OtoAccess or Noah: Choose your database Data storage options are available depending on your application. Most of the Eclipse software module results are collected in OtoAccess for easy retrieval, review and export to your EMR. The ASSR module is also integrated within NOAH to allow transference of important ABR threshold estimation into hearing aid fitting formulas for infants. Are you future-safe? Feedback from audiology experts assist in our development process, ensuring more effective integration of our software for today and tomorrow. Upgrades are available for years to come. A preview of the benefits Improved preamplifier - reduces noise levels up to 25% in ABR/ASSR recordings Revolutionary CE-Chirp stimuli for faster data acquisition Quick and easy waveform editing and marking tools Multiple customizable normative data options Convenient pre-loaded test protocols Simple, direct print to PDF (EMR/EHR ready) or export to XML 2

Silence is the Key The Eclipse preamplifier provides unrivalled stealth with only 4nV of internal noise 3

Software modules for any challenge Database NOAH Data Storage & Sharing OtoAccess TM Data Storage & Sharing Todd B. Sauter, M.A. Audiology Associates of Worcester Massachusetts The Eclipse has the largest number of clinically-relevant features of any AEP device today. The platform is an excellent blend of parameter flexibility and user-friendliness. 4

ABR EP25 ABR, MLR, LLR, P300, MMN, ECochG, eabr ASSR Threshold assessment OAE DPOAE20 Screening and clinical DPOAE TEOAE25 Screening and clinical TEOAE 5

CE-Chirp Stimulus Family The Gold standard for threshold assessment CE-Chirp The Gold standard for threshold assessment Auditory Evoked Potentials Traditional Click CE-Chirp Stimulus 6

New technologies. New standards. New ABR. The introduction of the CE-Chirp LS stimulus family is an overall improvement to the original CE-Chirp stimulus family. Silence eliminating the noise Reducing noise is the single most important factor for improving any evoked potential recording. The newly reengineered Eclipse preamplifier reduces that noise by an astonishing 25%. For an easier visual evaluation of the NB CE-Chirp responses, each of the NB CE- Chirp stimuli have been time shifted to provide latencies similar to Click and the CE-Chirp LS stimulus. The time-shifted NB CE-Chirps are named NB CE-Chirp LS, as the placements are level specific. Otherwise, the NB CE-Chirp LS are identical to the original NB CE-Chirp. The online display of the Fmp serves as a calculated response confidence. In this example, 99% response confidence was exceeded after only 1500 sweeps. CE-Chirp Stimulus Family Double your response amplitudes The revolutionary CE-Chirp stimulus family for threshold assessment (developed by Claus Elberling) compensates for frequency specific cochlear travel times and generates waveform responses up to twice the size of traditional click or tone burst stimuli. The original CE-Chirp was designed for optimal response amplitude at medium stimulation intensities. By using the level specific CE-Chirp, clearer waveform morphology at high intensities is also available. The CE-Chirp stimulus family is incorporated in the ABR and ASSR software modules from Interacoustics. Bayesian Weighting saves you valuable time Using Bayesian Weighting during your ABR recording ensures that waveforms remain stable even during periods of patient activity. The influence of patient noise is minimized during the recording, resulting in continuously lower noise in the running average, saving valuable test time. Rather than testing for a certain number of sweeps, the residual noise should be used as a stop criteria. Fmp knowing when to stop Imagine having an objective waveform confidence indicator to assist you in confirming the presence or absence of a response. The Fmp graph provides objective and mathematical information based on multiple points within the recording to assist with your waveform analysis. Use of the Fmp provides a reduction in test time and confidence in your diagnosis. 7

EP25 From diagnostic ABR to specialized AEP Vestibular EP This is a special version for the vestibular clinic. It holds protocols such as ECochG and rate study tests dedicated for the vestibular assessment test battery. 8

EP25 Comprehensive Clinical AEP For specialized procedures requiring the full spectrum of AEPs: Go for the Advanced Clinical EP25. A new standard The contemporary interface delivers unrivalled ease-of-use and superior clarity, which will help you achieve clear and reproducible results in a confident and timely manner. Pre-loaded protocols peer-reviewed by key-experts, easy tailoring of manual and automatic test protocols and a multitude of useful tools make the Eclipse the preferred choice for threshold and neurological ABR. The benefits of specialized features The EP25 incorporates functionality for early, middle, and late responses, including P300 and MNN tests. For your daily routine Threshold & neurological ABR testing & eabr Bayesian weighting Residual noise calculator Fmp calculator SNR 3:1 ratio calculator CR, RA, INC waveform markers Normative latency data for click, CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS Single/split screen CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS for optimized threshold assessment AMLR, ALLR & P300/MMN testing CM & ECochG testing ECochG Area Ratio Calculation by John Ferraro Displaying Right and Left ear in a split screen format is beneficial when performing threshold work. Unique ECochG Area Ratio Calculation implementation. 9

ASSR Where speed meets accuracy Cut test times in half The Interacoustics ASSR system reduces test times by 50% thanks to Narrow Band CE-Chirp stimuli and new powerful automated dual response detection methods. A new (and faster) generation Interacoustics ASSR represents a true breakthrough and a new generation in ASSR threshold estimation. The ASSR software enables 8 frequencies to be tested simultaneously to threshold in less than 20-30 minutes through the use of Narrow Band CE-Chirp stimuli and a patented detection engine. The Interacoustics ASSR software uses the Narrow Band CE-Chirp stimuli to generate a maximal response, which makes the detection fast and efficient. The dual detection engine evaluates both the phase and the response magnitude from 12 of the higher harmonics of the fundamental modulation rate. This patented technology can reduce test time by 50% compared to traditional ASSR systems and offers unsurpassed accuracy. Save data directly to NOAH The estimated audiogram generated by the Interacoustics ASSR can be saved to NOAH. The estimated audiogram can easily be transferred to Genie or other similar hearing aid fitting software, ensuring a smooth and accurate hearing aid fitting. Full control full speed You will dramatically shorten test time as you are in full control of selecting the appropriate stimulus levels independently for each frequency based on current and previous results. Also, you are able to change the stimulation rate during testing depending on the state of your patient. All in all: Full control allows full agility and speed. ASSR audiogram. ASSR detection. 10

DPOAE20 TEOAE25 Otoacoustic emissions The Eclipse hardware platform accommodates DPOAE and TEOAE capabilities. Shared features and benefits Lightweight probe with low internal noise Easy to place in the ear Inexpensive to maintain Auto probe check determines correct placement Validity checkmarks for OAE detection confirmation User-controlled noise sensitivity and rejection for easier collection DPOAE20 Distortion product emissions The DPOAE20 module produces detailed DP Grams with protocols designed by the user for their preferences or requirements. Build your own customized normative data sets or use the supplied norms from Interacoustics. TEOAE25 Transient evoked emissions The TEOAE25 uses linear or non-linear broad band clicks to evoke otoacoustic emissions. The extensive range of clinical options provide a full clinical evaluation of TEOAEs. The TEOAE25 also has protocol settings for automatic display of a pass/ refer result for hearing screening. Factory defaults are also available. 11

Interacoustics Interacoustics is a world leading provider of diagnostic solutions in the field of hearing and balance assessment. Since 1967 we have designed and manufactured our innovative diagnostic solutions for the world of audiology with a constant focus on providing our customers with quality, dependable products. With you at all times We operate in over 100 countries worldwide through a carefully selected network of distributors and service centres. Purchasing an Interacoustics product guarantees not only a quality product, but also direct access to our highly professional training and support service. Product specifications All technical and hardware specifications concerning software modules and the Eclipse platform can be downloaded from our website. Read more at interacoustics-us.com Interacoustics USA 10393 West 70th Street Eden Prairie, MN 55344 T +1 800 947 6334 F +1 952 903 4200 info@interacoustics-us.com interacoustics-us.com Go online to explore our full product range ABR/OAE Balance Assessment Fitting Systems Middle Ear Analyzers Audiometers Interacoustics a/s - 8101801-US - 4-10/2015