The full veneer crown is one of the most important

Similar documents
The Convergence Angle of Full-coverage Crown Preparations Made by Dental Students

INFLUENCE OF APPLICATION SITE OF PROVISIONAL CEMENT ON THE MARGINAL ADAPTATION OF PROVISIONAL CROWNS

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

Evaluating the Effect of a Sloping Shoulder and a Shoulder Bevel on the Marginal Integrity of Porcelain-Fused-to-Metal (PFM) Veneer Crowns

Clinical Studies of Dental Cements: III. Seven Zinc Oxide-Eugenol Cements Used for Temporarily Cementing Completed Restorations

Hex-Lock Abutment System. Restorative Manual

TOOTH PREPARATION. (Boucher's Clinical Dental Terminology, 4th ed, p239)

The effectiveness of auxiliary features on a tooth preparation with inadequate resistance form

Double-casting method for fixed prosthodontics with functionally generated path

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

FR Attachment Instructions Removable Partial Dentures

Advance Dental Simulation Module on Crown Preparation

UDELL DENTAL LABORATORY Instructions for Use

Dowel restorations Treatment with a post and core

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Removable Partial Dentures

Hands-on Posterior Tooth Preparation. Practical Skills Courses, SWL, 25/11/2016

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

Base. Base Metal (A) (B) (C) (ANOVA)

CORRESPONDING AUTHOR: ABSTRACT

Cast Partial Denture Improving Emergence and Masticatory Function - A Case Report

cement-retained single crowns using cementable abutments

CEREC 3D Preparation Guideline

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Construction of Removable Partial Denture

Advanced restorative techniques and the full mouth reconstruction: the use of gold copings in bridgework

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

SURVEYING OF REMOVABLE PARITAL DENTURES FEB, 11, 2015

Ceramic Based Aesthetic CAD/CAM Restorative

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

SCD Case Study. Attachments in Prosthodontics

Comparison of Fracture Resistance of Cast Post and Core using Different Alloys: An Unexplored Frontier

The width of the MCXL step bur is 1.4 mm wide and has a blunt end. As the bur approaches the inside of

CAD/CAM PREPARATION GUIDELINES & TISSUE MANAGEMENT TECHNIQUES RECOMMENDATIONS FOR OPTIMAL SCANNING, DESIGNING, AND MILLING

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Preci Clix Instructions for Ball Retained Overdenture Attachments

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

Effect of surface treatment with commercial primers on tensile bond strength of auto-polymerizing resin to magnetic stainless steel

Occlusal rehabilitation of posterior fixed prostheses: A clinical report

Stainless Steel Crowns

DENTAL MATERIALS STUDY GUIDE

Wear Rates of Resin Composites

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Marginal Adaptation of Metal Ceramic Crowns Cast from Four Different Base Metal Alloys before and after Porcelain Application

What are the advantages and disadvantages of an inlay or onlay?

In nitro bond strength of cements to treated teeth

Comparison between Acetal Resin and Cobalt-Chromium. Removable Partial Denture Clasp Retention: An in vitro Study.

King Saud University College of Dentistry Department of Prosthetic Dental Sciences DR. EMAN ALHAMDAN. Course Director - MUC DR.

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

STONE V PRINTED MODELS

The Effect of Using Modified Flask on the Porosity of Processed Heat- Cure Acrylic Resin

Implant Esthetic Failure

Shadeguides Ceramic Veneers: Tooth Preparation for Enamel Preservation

VIP Partner Laboratory (PL) Process Flow

Preci Clix Instructions for Ball Retained Overdenture Attachments

Dr.Adel F.Ibraheem Partial Veneer Crown(Three quarter crown) Three quarter (¾ )crown: Uses: Indications ---- For posterior teeth ;

Contents. Section I WHY

OT EQUATOR CASTABLE Single Attachment for Overdentures

The University of Jordan Faculty of Dentistry Department of Conservative Dentistry and Prosthodontics 2014/2015

Universal Plunger Loc Attachment

User Case Production of titanium abutments with inlab MC X5. dentsplysirona.com March 2017

Novel Removable Keeper System for Magnetic Attachments on Overdenture Abutments

CASE REPORT ABSTRACT INTRODUCTION. AIMS AND OBJECTIVES Aims

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Part II National Board Review Operative Dentistry. Module 3D General Questions Answers in BOLD (usually the first answer)

Patient demand for esthetic dentistry

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

HU-Friedy programs. novatech INSTRUMENTS. a hu-friedy key opinion leader

Removable Prosthodontics. Summative Evaluations

I n t r o d u c t i o n t o F i x e d P r o s t h o d o n t i c s : C r o w n a n d B r i d g e T e c h n o l o g y ( 1 2 A )

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

An Anterior Tooth Size Comparison in Unilateral and Bilateral Congenitally Absent Maxillary Lateral Incisors

Lithium Disilicate. Zirconia

UDELL DENTAL LABORATORY Instructions for Use AND ERA-RV

All Ceramic Inlays - Coming of Age

AN INJECTION MOULDING DEVICE, IMPROVING THE EXISTING INJECTION SYSTEM FOR ACRYLIC DENTURE FABRICATION

Stress distribution within circumferential clasp arms

2017 Oregon Dental Conference Course Handout

LOCATOR ROOT ATTACHMENT SYSTEM

The Reinforced Removable Retainer

BASIC Level 1 Practitioner Certification

Comparison of Dimensional Accuracy of Four Different Die Materials before and after Disinfection of the Impression: An in vitro Study

Metal ceramic crowns. Clinical and Laboratory steps

TECHNICAL GUIDE. For use with CEREC

Effects of Proximal Grooves and Abutment Height on the Resistance of Resin cemented Crowns in Teeth with Inadequate Resistance: An In Vitro Study

OCCLUSION IN NEWLY FABRICATED BRIDGE*

CERASMART. The new leader in hybrid ceramic blocks

Relining and Rebasing of complete denture

CAUSE OF TECHNICAL FAILURES OF CONICAL CROWN-RETAINED DENTURE (CCRD): A CLINICAL REPORT

Essentials of. Dental Assisting. Edition 6. Debbie S. Robinson Doni L. Bird

Lect. Pre. Clin

Restoring Straumann implants. with Locator abutments.

For the oral rehabilitation

RESTORING ENDODONTICALLY TREATED TEETH POST RESTORATIONS CROWNS. Dr. Szabó Enikő associate professor

This PDF is available for free download from a site hosted by Medknow Publications

MAURO FRADEANI, MD, DDS

Transcription:

CLASSIC ARTICLE The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations J. R. Gavelis, DMD, a J. D. Morency, DMD, b E. D. Riley, DMD, c and R. B. Sozio, DMD d University of Connecticut, School of Dental Medicine, Farmington, Conn; Naval Air Station Hospital, Corpus Christi, Tex; and Harvard School of Dental Medicine, Boston, Mass The full veneer crown is one of the most important restorations in the armamentarium of the restorative dentist. The restoration can restore severely deteriorated teeth. One problem recognized by clinicians is that the cementing medium may prevent the seating of the full crown, positioning it in hyperocclusion and causing inadequately sealed margins. Investigators report the film thickness of cement along the axial walls of the preparation influences the seating of the restoration. The factors of cementation pressure, 1-3 duration of cementation, 2,3 powder/liquid ratio of the cement, 2,4-6 preparation dimensions, 1,2,4 type of cement, 6,7 occlusal perforations, 1,2 die spacers, 7 and relief of the internal crown surface 4,8 have been related to the film thickness. One study related the type of finish line of the preparation to the film thickness. Fusayama et al 3 cemented cast full crowns onto extracted teeth prepared with the 90-degree shoulder, the 45-degree shoulder, and featheredge margins. They reported that the featheredge margin provided the best sealing effect followed by the 45-degree shoulder and 90-degree shoulder, respectively. In an earlier study, Fusayama et al 9 found that, even without cement, crowns fail to seat completely owing to the numerous variables associated with the casting process. Teteruck and Mumford 10 also reported similiar findings while comparing castings made with various gold alloys and investments. All investigations in which patterns were waxed and cast and the castings returned to the original dies were affected by the casting variables. In an effort to eliminate the casting error, McCune 6 fabricated castings on the Bureau of Standards die and Presented as a table clinic before the American Academy of Crown and Bridge Prosthodontics, Chicago, Ill. a Assistant Professor, Department of Restorative Dentistry, University of Connecticut, School of Dental Medicine. b Staff Dentist, Naval Air Station Hospital. c Associate Professor, Department of Prosthetic Dentistry, Harvard School of Dental Medicine. d Associate Professor and Head, Department of Graduate Prosthetic Dentistry, Harvard School of Dental Medicine. Reprinted with permission from J Prosthet Dent 1981;45:138-45. J Prosthet Dent 2004;92:1-7. then poured improved dental stone directly into the castings to form the dies. The purpose of this study was to correlate margin design with the seating and sealing of cemented full cast crowns under standardized, simulated clinical conditions. METHODS AND MATERIAL Eight stainless steel dies were machined to produce a crown preparation similar in volumetric size to an average molar. Seven dies were 10 mm in diameter and the eighth was 8 mm in diameter at the finishing lines. Each die measured 6 mm from the occlusal surface to the end of the preparation, and each had a 5-degree taper of the axial walls with a convergence angle of 10 degrees. Two dies had featheredge finish lines, one 8 mm in diameter and the other 10 mm. The other margin designs were: a 1 mm 90-degree shoulder; a 45-degree shoulder; a 90-degree shoulder and a chamfer with bevels 1 mm long parallel to the axial walls; a 1 mm 90- degree shoulder with a 45-degree bevel; and a 1 mm 90-degree shoulder with a 30-degree bevel (Fig. 1). Five crowns were fabricated from each die. The crowns were waxed on the steel dies, invested (Beauty Cast; Whip Mix Corp, Louisville, Ky), and cast (Firmilay; J. F. Jelenko, New Rochelle, NY) in type III gold (Fig. 2). Because of the casting variables reported in previous studies, 9,10 a method similar to that described by McCune 6 was used to fabricate dies directly into the castings. After the castings were pickled and the sprues removed, the castings were boxed with masking tape. The castings were lubricated with a fluorocarbon dry release agent (Crown Industrial Products Co, Hebron, Ill) and a measured volume of methyl methacrylate (Duralay; Reliance Dental Mfg. Co, Chicago, Ill) was vibrated into the castings to make direct dies. Twentyfour hours later, the dies were undercut below the finish line to facilitate measurements and indexed to aid proper repositioning at cementation (Fig. 3). The crowns were cemented onto the Duralay dies with an Instron testing machine (Instron Corp, Canton, Mass) (Fig. 4, A). An orange wood stick was placed between the compression head of the testing machine JULY 2004 THE JOURNAL OF PROSTHETIC DENTISTRY 1

THE JOURNAL OF PROSTHETIC DENTISTRY GAVELIS ET AL Fig. 1. Diagram of standard die used in study, with various finish line preparations in inserts. Fig. 2. Crowns were waxed on steel dies (A) and cast in a type III gold alloy (B). and the crown to simulate clinical practice and to distribute the cementation pressure more evenly (Fig. 4, B). Initially cementation pressure was 100 pounds, but this was slowly reduced to 57 pounds over the 10-minute cementation interval. Then the cemented crowns were embedded in plastic and sectioned through the center of the crown with a diamond disk on an ultrastructural analysis cutting machine (Buehler Ltd, Evanston, Ill) (Fig. 5). The cut surfaces were wet polished with progressively finer grit sandpaper, 240 to 600 grit, toward the crown to eliminate flash. The cement spaces were measured to the nearest micron with an eyepiece 2 VOLUME 92 NUMBER 1

GAVELIS ET AL THE JOURNAL OF PROSTHETIC DENTISTRY Fig. 3. Dies were indexed to facilitate repositioning during cementation (A) with arrows and (B) with a depression and corresponding dimple. Fig. 4. A, Crowns were positioned for cementation with an Instron testing machine. B, An orange wood stick was used to distribute pressure evenly during cementation. JULY 2004 3

THE JOURNAL OF PROSTHETIC DENTISTRY GAVELIS ET AL Fig. 5. Cemented crowns were sectioned with diamond disk (A) through center of crown (B). Fig. 7. Arrows show orientation and location where cement lines were measured. Fig. 6. Photomicrograph of cement spaces at margins. micrometer mounted on a reflecting microscope (Fig. 6). RESULTS Measurements were made of the cement lines at points shown in Fig. 7. The measurements from each half of the sectioned crowns were averaged to arrive at thickness values of the cement line at the margin, shoulder, axial wall, and occlusal surface. The cement thicknesses at the margin and occlusal surface were analyzed to find the amount of seal and seat afforded by the various preparations. Statistical analysis consisted of one-way analysis of variance with multiple comparisons using Tuckey s test and Scheffe s test. Significance was determined at the P\.05 level. The data in Table I and Fig. 8 show that the featheredge preparations had the best marginal seal, 31 and 34 m. The parallel bevel preparations followed, with marginal seals of 41 and 44 m. No statistical difference was found between the featheredge and parallel bevel preparations. The 90-degree shoulder had a cement space of 67 m at the margins. The 45-degree shoulder, shoulder with 30-degree bevel, and shoulder with 4 VOLUME 92 NUMBER 1

GAVELIS ET AL THE JOURNAL OF PROSTHETIC DENTISTRY Fig. 8. Comparison of cement space at margins and occlusal surface of various finish line preparations. Table I. Marginal seal and occlusal seating as measured in microns Marginal seal Occlusal seat Marginal design Measurement (m) SEM SD Measurement (m) SEM SD Featheredge, 10 mm diameter 31 6 3.30 7.4 163 6 12.66 28.3 Featheredge, 8 mm diameter 34 0.98 2.2 157 8.81 19.7 45-degree shoulder 95 7.65 17.1 138 12.66 28.3 90-degree shoulder 67 10.20 22.8 85 14.49 32.4 Shoulder, parallel bevel 41 0.72 1.6 214 12.48 27.9 Chamfer, parallel bevel 44 3.44 7.7 196 15.07 33.7 Shoulder, 30-degree bevel 99 11.72 26.2 170 18.29 40.9 Shoulder, 45-degree bevel 105 15.83 35.4 153 25.13 56.2 45-degree bevel followed, with spaces of 95, 99, and 105 m, respectively. There was no significant difference between these three finish lines, but the differences between this group and the 90-degree shoulder group and the featheredge and parallel bevels group were significant. The measurements at the occlusal surface found the shoulder preparation restorations to be the most completely seated with an 85 m cement space. Ideally, the space at the margin and that at the occlusal part of the shoulder preparation should be identical. The discrepancy in these areas was found not to be statistically significant. The order of seating after the shoulder preparation was the 45-degree shoulder at 138 m, the shoulder with 45-degree bevel at 153 m, the featheredges at 157 and 163 m, the shoulder with 30- degree bevel at 170 m, the chamfer with parallel bevel at 196 m, and the shoulder with parallel bevel at 214 m. Differences were not significant between the following groups: 45-degree shoulder, featheredges, and shoulders with 45-degree and 30-degree bevels. The differences between members of these groups, the 90- degree shoulder group, and the group with parallel bevel preparations were significant. DISCUSSION By using standardized steel dies of volumetric size similar to that of teeth, rather than prepared natural teeth, castings of duplicate size and shape are produced, thus decreasing the variation within each group of finish line preparations. The machined dies also enable the investigator to accurately control the variables of preparation dimensions, degree of axial wall taper, and the finish line dimensions. The Bureau of Standards die was not utilized because it is 15 mm in diameter, which is much larger than a natural molar, and the convergence angle of the Bureau of Standards is 3 degrees, which is too severe for the clinical situation. Textbooks recommend a convergence angle of 4 to 14 degrees. 11,12 For JULY 2004 5

THE JOURNAL OF PROSTHETIC DENTISTRY GAVELIS ET AL Fig. 9. Control showing no shrinkage of acrylic resin away from crown. these reasons, the dies were machined to a convergence angle of 10 degrees with a 5-degree taper on each axial wall. Perhaps the most significant source of variation between the results of previous studies 3-6,8-10 stems from casting variables. This source of error was controlled with acrylic resin dies poured directly into boxed castings. It is accepted that methyl methacrylate resin shrinks on polymerization. However, this factor did not affect the present study. Controls were established by pouring dies into castings, followed by embedding (unseparated) and sectioning 24 hours after polymerization. Microscopic examination revealed no shrinkage spaces between the die and the internal surface of the crown (Fig. 9). Shrinkage did occur, but it was limited to the open end of the boxed castings, thus causing meniscus formation. To further relate this study to the clinical situation, the crowns were cemented with an orange wood stick placed between the crown and the compression head of the Instron testing machine. The stick aided in dispersing the cementation forces more evenly. The findings of this study supported those of previous studies and the predictions based on the geometry of the preparations. Most of the crowns seated obliquely on the dies, a finding also reported by Jorgensen 1 and Bassett. 8 As geometrically predicted, the featheredge margin had the best marginal seal. There was no significant difference between the featheredge preparations of 8 mm and 10 mm diameters. Ranked next were the parallel bevel margins with acceptable 13 marginal seals in the 40 m range. A finding which was not consistent with other studies 3,11,12,14 was that the 90-degree shoulder preparation ranked after the parallel bevel margins with an opening of 67 m. The 45-degree shoulder and shoulders with 30-degree and 45-degree bevels were the worst seals, with openings ranging from 95 to 105 m. For geometric design, the shoulder would be expected to have the greatest opening at the margins. This finding is explained by evaluating the measurements of the occlusal space. The 90-degree shoulder preparation had the best seat with an 85 m cement space. The other preparations followed, with the parallel bevel preparations the worst observed with 196 to 214 m cement spaces. The seating of the 90-degree shoulder preparation improved the marginal seal. However, the featheredge and parallel bevel preparations were superior in sealing the margins despite the poor seating. The differences in measurements of occlusal seating is an interesting finding since the only variable was the type of finish line. If the degree of seating were solely dependent on the film thickness of the axial wall cement, all specimens would have seated to the same degree occlusally. This indicates that the variation of the finish line is related to the different degrees of crown placement. The question is how the finish lines affect cementation. When the crown is cemented the axial wall of the preparation approaches the axial wall of the internal crown surface. The escape path for the cement decreases, causing the hydrostatic pressure within the crown to increase until it matches the patient s biting pressure. At this point, the crown fails to seat further. If the cement does not set, it will continue to escape until the particles at the axial walls prevent further seating. Certain finish lines apparently facilitated the escape of cement early in the cementation process under the conditions of the study. It is thought that less hydrostatic pressure results in greater seating of the restorations. However, the explanation is not simple. The filtration process observed by Jorgensen 1,2 and Petersen 15 is thought to contribute to the differences observed in this study. Hoard et al 16 demonstrated that peak hydrostatic pressures are short-lived and are redistributed into intracoronal pressures. They concluded that this leads to various localized filtration processes which affect the flow of cement and final seating of the crown. 6 VOLUME 92 NUMBER 1

GAVELIS ET AL THE JOURNAL OF PROSTHETIC DENTISTRY The better seating of the castings with shoulder preparations is due to the poor seal prior to complete cementation. This design allows the cement to escape marginally more readily without filtration. With the other finish line preparations, the margins seal earlier and start filtration sooner. With the parallel bevel preparations, the comparatively large number of internal angles produces the greatest amount of filtration and poor seating. Venting, 1,2 die spacing, 7 and internal relief of the crown 4,8 help to reduce filtration and enable the parallel bevel preparations to seat more completely. In relating this study with actual clinical practice it must be remembered that the dies fit the crowns perfectly. In clinical practice the casting variables may have greater effect on the fit of the crowns than the variation of the finish lines. Further studies are needed to evaluate the filtration process and hydrostatic pressures within the crown. Studies also should be done to correlate the increases in hydrostatic pressure in crown restorations with different finish lines with the seating of the crowns. SUMMARY The influence of the marginal design of a full crown on the occlusal seat and marginal seal of a cemented full crown restoration was examined. Under the conditions of the study, the featheredge and parallel bevel preparations demonstrated the best marginal seal, followed in order by the full shoulder, 45-degree shoulder, and finally the 90-degree shoulders with 30-degree and 45- degree bevels. With regard to seating of the restoration, the 90-degree full shoulder demonstrated the best seat, followed in order by the 45-degree shoulder, 90-degree shoulder with 45-degree bevel, featheredge, 90-degree shoulder with 30-degree bevel, chamfer with parallel bevel, and finally 90-degree shoulder with parallel bevel. REFERENCES 1. Jorgensen KD. Factors affecting the film thickness of zinc phosphate cements. Acta Odontol Scand 1960;18:189. 2. Jorgensen KD. Structure of the film of zinc phosphate cements. Acta Odontol Scand 1960;18:491. 3. Fusayama T, Ide K, Hosoda H. Relief of resistance of cement of full cast crowns. J Prosthet Dent 1964;14:95. 4. Kaufman EG, Coelho DH, Colin L. Factors influencing the retention of cemented gold castings. J Prosthet Dent 1961;11:487. 5. Kaufman EG, Colin L, Schlagel E, Coelho DH. Factors influencing the retention of cemented gold castings: The cementing medium. J Prosthet Dent 1966;16:731. 6. McCune, R. J. The effect of occlusal venting and film thickness on the cementation of full cast crowns. [thesis] Indianapolis (IN): Indiana University, School of Dentistry; 1968. 7. Eames WB, O Neal SJ, Monteiro J, Miller C, Roan JD Jr, Cohen KS. Techniques to improve the seating of castings. J Am Dent Assoc 1978; 96:432. 8. Bassett RW. Solving the problems of cementing the full veneer cast gold crown. J Prosthet Dent 1966;16:740. 9. Fusayama T, Ide K, Kurosu A, Hosoda H. Cement thickness between cast restorations and preparation walls. J Prosthet Dent 1963;13:354. 10. Teteruck WR, Mumford G. The fit of certain dental casting alloys using different investing materials and techniques. J Prosthet Dent 1966; 16:910. 11. Tylman SD. Theory and practice of crown and fixed partial prosthodontics. 6th ed. Philadelphia: Mosby; 1971. p. 223. 12. Johnston JF, Phillips RW, Dykema RW. Modern Practice in Crown and Bridge Prosthodontics. 3rd ed. Philadelphia: W.B. Saunders; 1971. p. 68. 13. Christensen GJ. Marginal fit of gold inlay castings. J Prosthet Dent 1966;16:297. 14. Pascoe DF. Analysis of the geometry of finishing lines for full crown restorations. J Prosthet Dent 1978;40:157. 15. Jorgensen KD, Petersen GF. The grain size of zinc phosphate cements. Acta Odontol Scand 1963;21:255. 16. Hoard RJ, Caputo AA, Contino RM, Koenig ME. Intracoronal pressure during crown cementation. J Prosthet Dent 1978;40:520. 0022-3913/$30.00 Copyright ª 2004 by The Editorial Council of The Journal of Prosthetic Dentistry doi:10.1016/j.prosdent.2004.03.024 JULY 2004 7