AIR FORCE SPECIALTY CODE 4B051 BIOENVIRONMENTAL ENGINEERING

Similar documents
Reports Overview. dosimetry services A Mirion Technologies Division. Featuring:

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Section 7 ALARA Program

University of Maryland Baltimore. Radiation Safety Standard Operating Procedure

Your Company Hearing Conservation Program

a. If dosimeters should be issued; b. What type(s) will be used and; c. The frequency that dosimeters will be exchanged

PERSONNEL MONITORING AND DOSIMETRY POLICIES

OKLAHOMA STATE UNIVERSITY X-RAY MACHINE PROGRAM AND PI HANDBOOK For easy navigation, please use Adobe s bookmark feature.

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

Radiation Protection Program 2017 Annual Audit Texas Tech University January 8, 2018

Trends in Occupational Exposure in Malaysia

GEX Recommended Procedure Eff. Date: 07/27/07 Rev.: C Pg. 1 of 10

COMPLEMENTARY TRAINING MATERIALS DUE TO NEW REGULATION. Ringhals AB

HEARING CONSERVATION PROCEDURE

Radiation Dose Specification

Encl: (1) Navy Medicine Hearing Conservation Program Implementation and Management

Delaware State University

FSIS DIRECTIVE

Quality Assurance and Radiation Protection Manual for Non-Human Use Radiation Generating Equipment

radiation monitoring programs Tailored to your needs

instadose dosimeters Dosimetry Services Division

Environmental Health & Safety Policy Manual

Implementation Guide for the DoseControl Dosimetry System

Radiation Safety Manual

Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

Radiation Safety Guide. Analytical X-Ray Equipment

HEARING CONSERVATION PROGRAM

San Diego Community College OSHA Standards

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C

DOELAP On-Site Assessment Requirements Checklist Page 1 of 24 Participant:

Hearing Conservation Program Table of Contents

X-RAY REGULATORY GUIDE

BEAUFORT COUNTY COMMUNITY COLLEGE OCCUPATIONAL NOISE

University of Cincinnati. Quality Assurance. and. Radiation Protection Manual. for. Non-Human Use. Radiation Generating. Equipment

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

FOOD ACT No.26 OF 1980

HEARING CONSERVATION PROGRAM

RADIATION MANAGEMENT PLAN EXPLANATORY NOTE

Procedure. Procedure

Radiation Safety General Awareness and ALARA Training

Controlled Substances Program. For Academic Units

in developing institutional policies, procedures, and /or protocols. The Canadian Society of

Radiation Safety for Safety Wardens

Hearing Conservation Program

Hearing Conservation Program

Hearing Conservation Program Regulations and Recommendations Summary

Craven Community College HEARING CONSERVATION PROGRAM

PROFICIENCY TESTING POLICY

New Entrants Safety Education Seminar for Georgia Motor Carriers CHAPTER 11

Personal Dosimetry. Radiation Protection Section Department of Medical Physics Colchester Hospital University NHS Foundation Trust

RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL

DENTAL ASSISTANT SPECIALTY. Clinical Skills-Radiology

Title: Code of Practice for users of personal dosimeters 1, 2

UC Merced Hearing Conservation Program

A Study of dose Distribution and Radiation Protection in Industrial Radiography in Ireland

SOUTHERN UTAH UNIVERSITY S WRITTEN HEARING CONSERVATION PROGRAM December 2017

Hearing Conservation Program

Introduction. Accessing EHS Assistant

Radiation Protection Program Update: The Details. July 2010

GUIDE TO THE APPLICATION TO POSSESS AND USE A SOURCE(S) FOR INDUSTRIAL APPLICATIONS

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

Upon successful completion of the course, the student should be competent in the following tasks:

Hearing Conservation Program

Utilize radiation safety principles to reduce the amount of radiation used to achieve desired clinical result.

HEARING CONSERVATION PROGRAM

Santa Clarita Community College District HEARING CONSERVATION PROGRAM. Revised

Model Safety Program

Hearing Conservation Plan

HEARING CONSERVATION PROGRAM

Radiation Protection Services in R.Macedonia

Final Rule for Preventive Controls for Animal Food

Colgate University. Bloodborne Pathogens Exposure Control Plan

Radiation Dose Reconstruction and Probability of Causation for Compensation

Hearing Conservation Program

ISEMIR An IAEA Tool for Radiation Protection Optimization in Interventional Cardiology and Industrial Radiography

International Practice Accreditation

NA-019 LEVEL 3 QUALIFICATION RECOGNITION FOR AS3669 AND EN 4179 / NAS 410

Nuclear power plants, hospitals, medical facilities, homeland security, and other organizations

Hearing Conservation Plan

Training Course on Small Field Dosimetry

Hearing Conservation Program. Southwestern Community College. Office of Human Resources

Biospecimen Adult Urine Procedures. Event: Pre-Preg, PV1, PV2, Birth, 6M, 12M, 36M, and 60M

Environmental Health and Safety. Hearing Conservation Program

Infrastructure of the Brazilian Government in Radioprotection Education

HEARING LOSS PREVENTION PROGRAM AND PROCEDURES

East Carolina University

Information Technology Solutions

Variation of Occupational Doses among Subspecialties in Diagnostic Radiology. A.N. Al-Haj, C.S. Lagarde, A.M. Lobriguito

THE CALIFORNIA STATE UNIVERSITY Office of the Chancellor 401 Golden Shore Long Beach, California (562)

NA-019 Level 3 Qualification Recognition for EN 4179 / NAS 410 and AS3669

The x-rays produced penetrate the body which absorbs, refracts, or reflects the x-ray beam energy depending on the tissue. Bone

RADIATION SAFETY REVIEW UIHC Environmental Services

Safety Committee Prototypical Safety Program Manual

NOISE CONTROL AND HEARING CONSERVATION PROGRAM

Eighth Annual Chapman Phytosanitary Irradiation Forum. Dosimetry for phytosanitary applications: dos and don ts. Florent KUNTZ

The University of Texas at El Paso

THE UNIVERSITY OF ALABAMA FUME HOOD MANAGEMENT PLAN

Scope This policy applies to all personnel and departments that clean, prepare and/or sterilize items intended for patient care use.

Transcription:

DEPARTMENT OF THE AIR FORCE Headquarters US Air Force Washington, DC 20330-1030 QTP 4B051-14 2 April 2015 AIR FORCE SPECIALTY CODE 4B051 BIOENVIRONMENTAL ENGINEERING USAF Personnel Dosimetry Program QUALIFICATION TRAINING PACKAGE Accessibility: Publications and forms are available on the e-publishing website at http://www.e-publishing.af.mil for downloading or ordering. Realeasability: There are no releasability restrictions on this publication.

Table of Contents STS Line Item 4.9.3.3: Enroll / Disenroll Personnel Dosimetry Program... 1 TRAINER GUIDANCE... 1 TASK STEPS... 2 TRAINEE REVIEW QUESTIONS... 3 PERFORMANCE CHECKLIST... 4 ANSWERS... 5 STS Line Item 4.9.3.4: Exchange/Ship dosimeters... 6 TRAINER GUIDANCE... 6 TASK STEPS... 7 TRAINEE REVIEW QUESTIONS... 8 PERFORMANCE CHECKLIST... 9 ANSWERS... 10 i

STS Line Item 4.9.3.3: Enroll / Disenroll Personnel Dosimetry Program TRAINER GUIDANCE Proficiency Code: PC Definition: Prerequisites: Training References: Additional Supporting References: CDC Reference: Training Support Material: Specific Techniques: Criterion Objective: Notes: 3c Can do all parts of the task. Needs only a spot check of completed work. Can identify why and when the task must be done and why each step is needed. None AFMAN 48-125, Personnel Ionizing Radiation Dosimetry AFI 48-148, Ionizing Radiation Protection AFMAN 48-125, Personnel Ionizing Radiation Dosimetry 10 CFR 20.2104, Determination of prior occupational dose 4B051 AFMAN 48-125, Personnel Ionizing Radiation Dosimetry Conduct hands-on training and evaluation. Given the materials listed, enroll/disenroll personnel into the Dosimetry Program successfully completing all checklist items with no trainer assistance. 1

TASK STEPS ENROLLING INTO THE DOSIMETRY PROGRAM: 1. Ask the individual whether he/she has had previous (or is currently receiving) exposure to ionizing radiation prior to registering into the program from working as a radiation worker outside the Air Force. 2. If yes, request any previous exposure reports. 1 3. Use The Radiation Dosimetry Web secure server to enroll the individual. 2 DISENROLLING FROM THE DOSIMETRY PROGRAM: 1. Determine if the dosimeter was worn during the monitoring period. 3 2. Complete the Personnel Information Change form using The Radiation Dosimetry Web and indicate the individual should be removed. 3. At the end of the monitoring period, submit all dosimeters for the individual(s) removed from the program to USAFSAM/OEA. LOCAL REQUIREMENTS: Ensure that an enrollee meets the following conditions: - Received training on proper wear and storage of TLD s - Knows where to find exposure results and get help in understanding his or her individual exposure? (BE) - Articulates that if he or she exceeds applicable occupational exposure limits while moonlighting that he or she may be removed from their AF radiation specific duties? (signed acknowledgement letter) - Received ALARA training - Received training on radiation work while pregnant (applicable to females only) NOTES: 1. AF Form 1527-2, Cumulative History of Individual Occupational Exposure to Ionizing Radiation, from the Radiation Dosimetry Laboratory (for exposure from an Air Force installation) or a NRC Form 4, Occupational Radiation Exposure History or equivalent (from the individual's employer) 2. The following information must be gathered prior to logging into the website: a. Area b. Name (last, first, middle initial) c. SSAN d. Gender e. TLD Type f. TLD ID # g. Wear Location h. Occupational Code i. Date of Issue 3. If the dosimeter was not worn during the monitoring period, on the 1523 module indicate that the TLD assigned to the individual was NOT WORN. 2

TRAINEE REVIEW QUESTIONS STS Line Item 4.9.3.3: Enroll / Disenroll Personnel Dosimetry Program 1. Who makes the decision to enroll personnel into the monitoring program? 2. For an Air Force employee, which document should be used to determine the individual s previous exposure to ionizing radiation? 3

PERFORMANCE CHECKLIST STS Line Item 4.9.3.3: Enroll / Disenroll Personnel Dosimetry Program Proficiency Code: PC Definition: 3c Can do all parts of the task. Needs only a spot check of completed work. Can identify why and when the task must be done and why each step is needed. DID THE TRAINEE YES NO ENROLLING INTO THE DOSIMETRY PROGRAM: 1. Ask the individual whether he/she has had previous (or is currently receiving) exposure to ionizing radiation prior to registering into the program from working as a radiation worker outside the Air Force.? 2. If yes, request any previous exposure reports? 3. Use The Radiation Dosimetry Web to enroll the individual? DISENROLLING FROM THE DOSIMETRY PROGRAM: 1. Determine if the dosimeter was worn during the monitoring period? 2. Complete the Personnel Information Change form using The Radiation Dosimetry Web and indicate the individual should be removed? 3. At the end of the monitoring period, submit all dosimeters for the individual(s) removed from the program to USAFSAM/OEA? Did the trainee successfully complete the task? TRAINEE NAME (PRINT) TRAINER NAME (PRINT) 4

ANSWERS 1. Who makes the decision to enroll personnel into the monitoring program? A: The installation RSO (Source: AFMAN 48-125, Personnel Ionizing Radiation Dosimetry, para 1.4.2) 2. For an Air Force employee, which document should be used to determine the individual s previous exposure to ionizing radiation? A: AF Form 1527-2, Cumulative History of Individual Occupational Exposure to Ionizing Radiation (Source: AFMAN 48-125, Personnel Ionizing Radiation Dosimetry) 5

STS Line Item 4.9.3.4: Exchange/Ship dosimeters TRAINER GUIDANCE Proficiency Code: PC Definition: Prerequisites: Training References: Additional Supporting References: CDC Reference: Training Support Material: Specific Techniques: Criterion Objective: Notes: 3c Can do all parts of the task. Needs only a spot check of completed work. Can identify why and when the task must be done and why each step is needed. None AFMAN 48-125, Personnel Ionizing Radiation Dosimetry AFI 48-148, Ionizing Radiation Protection AFMAN 48-125, Personnel Ionizing Radiation Dosimetry 4B051 TLD Holder TLD Hanger TLD Opener TLDs Listing 1523 Shipping Container Caution Label Address Label Tape Conduct hands-on training and evaluation. Given the equipment listed, prepare thermoluminescent dosimeters (TLD) for shipment successfully completing all checklist items with no trainer assistance. 6

TASK STEPS 1. Account for all dosimeters. 2. Exchange previous period dosimeters with new monitoring period dosimeters (1 for 1). 3. Disassemble dosimeters and crosscheck the Listing 1523. 4. Remove the identification labels from the hangers and discard. 5. Place the TLD holders in the original shipping tray. 6. Pack extremity dosimeters in a separate container. 7. Seal all dosimeters and original Listing 1523 in the container. 8. Secure the package and seal all edges. 9. Attach one Caution label and address label to the package. 10. Coordinate shipment with the shipping agency use most expeditious and traceable means to ship back to the USAF Radiation Dosimetry Lab. 11. Utilize DOEHRS (or equivalent), if applicable. LOCAL REQUIREMENTS: NOTES: 7

TRAINEE REVIEW QUESTIONS STS Line Item 4.9.3.4: Exchange/Ship dosimeters 1. List the items placed into the shipping container returning to USAF Radiation Dosimetry Laboratory. 2. By what method/means should the TLD package be shipped? 3. How soon after the end of the monitoring period must the dosimeters be shipped to USAF Radiation Dosimetry Laboratory for analysis? 8

PERFORMANCE CHECKLIST STS Line Item 4.9.3.4: Exchange/Ship dosimeters Proficiency Code: PC Definition: 3c Can do all parts of the task. Needs only a spot check of completed work. Can identify why and when the task must be done and why each step is needed. DID THE TRAINEE YES NO 1. Account for all dosimeters? 2. Exchange previous period dosimeters with new monitoring period dosimeters (1 for 1)? 3. Disassemble dosimeters and crosscheck the Listing 1523? 4. Remove the identification labels from the hangers and discard? 5. Place the TLD holders in the original shipping tray? 6. Pack extremity dosimeters in a separate container? 7. Seal all dosimeters and original Listing 1523 in the container? 8. Secure the package and seal all edges? 9. Attach one Caution label and address label to the package? 10. Coordinate shipment with the shipping agency use most expeditious and traceable means to ship back to the USAF Radiation Dosimetry Lab? 11. Utilize DOEHRS (or equivalent), if applicable? Did the trainee successfully complete the task? TRAINEE NAME (PRINT) TRAINER NAME (PRINT) 9

ANSWERS 1. List the items placed into the shipping container returning to USAF Radiation Dosimetry Laboratory. A: Place the TLD holders in the original shipping tray. Pack any extremity dosimeters in a separate container. Seal all dosimeters and the original Listing 1523 in the shipping container that was retained at the beginning of the monitoring period. Secure the package with reinforced tape; care must be taken to completely seal all edges. Attach one CAUTION label and the address label to the package. (Source: AFMAN 48-125, Personnel Ionizing Radiation Dosimetry, 4 Oct 2011, Table A4.13) 2. By what method/means should the TLD package be shipped? A: Send the shipment to USAFSAM/OEA by the most expeditious and traceable means (normally FedEx or certified mail return receipt requested). (Source: AFMAN 48-125, Personnel Ionizing Radiation Dosimetry, 4 Oct 2011, Table A4.13) 3. How soon after the end of the monitoring period must the dosimeters be shipped to USAF Radiation Dosimetry Laboratory for analysis? A: Package shipped to USAFSAM/OEA within ten (10) calendar days after the end of the monitoring period? (Source: AFMAN 48-125, Personnel Ionizing Radiation Dosimetry, 4 Oct 2011, Table A4.13) 10