Utilization Status of SCENARIA at the Diagnostic Imaging Center and Breast Center. Koutarou Takahashi MEDIX VOL. 61 P.4 P.7

Similar documents
Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

IOWA RADIOLOGY 1. Guide to CT Scans Clive Downtown Des Moines

Cardiac CT Techniques in Neonates (and infants)

Fulfilling the Promise

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Cardiac CT Angiography

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Cardiac Imaging Tests

Faster Cancer Treatment: Using a health target as the platform for delivering sustainable system changes

Managing Radiation Risk in Pediatric CT Imaging

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose?

Ct angiography, icd-10

High Tech Imaging Quick Reference Guide

MR Advance Techniques. Cardiac Imaging. Class IV

Hospital OQR Quality Measures and Timelines for CY 2015 and Subsequent Payment Determinations

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

Disclosure Information

Cardiac CTA without and with IV Contrast

Pulmonary Embolism. Thoracic radiologist Helena Lauri

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

Combined Anatomical and Functional Imaging with Revolution * CT

Cardiac Nuclear Medicine

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

05/02/ CPT Preauthorization Groupings Effective May 2, Computerized Tomography (CT) Abdomen 6. CPT Description SEGR CT01

Cardiac CTA Prospective Gating Broad Beam

b. To facilitate the management decision of a patient with an equivocal stress test.

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

BrightSpeed Elite CT with ASiR: Comparing Dose & Image Quality Rule Out Pulmonary Embolism on Initial & Follow-Up Exam

Low Dose Era in Cardiac CT

Patient preparation and coronary CTA techniques. Gregory Kicska, M.D. Ph.D. University of Washington, Thoracic Imaging

Managing Patient Dose in Computed Tomography (CT)

A comparison of radiation doses from modern multi-slice Computed Tomography angiography and conventional diagnostic Angiography:

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Noncoronary Cardiac MDCT


CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

X-Ray & CT Physics / Clinical CT

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Coronary Artery Calcium Score

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

BlueAdvantage SM. & BlueChoice SM Radiology Prior Authorization Program Code List CPT /HCPS

Overview of Medical Diagnostic and Interventional Imaging: Usage Patterns

ACR MRI Accreditation: Medical Physicist Role in the Application Process

CT Quality Control Manual FAQs

Effective Utilization of Imaging. John V. Roberts, M.D. Premier Radiology Abdominal Imaging

Radiology Codes Requiring Authorization*

NIH Public Access Author Manuscript Acad Radiol. Author manuscript; available in PMC 2009 September 16.

Radiation Dose Reduction Strategies in Coronary CT Angiography

Cardiac Computed Tomography

Diagnostic Imaging Utilization Management and Consultation Management Programs Imaging Code Listing for Connecticut, Maine and New Hampshire

A Snapshot on Nuclear Cardiac Imaging

Mitsubishi Heavy Industries Technical Review Vol. 51 No. 1 (March 2014)

Impact of Body Mass Index and Metabolic Syndrome on the Characteristics of Coronary Plaques Using Computed Tomography Angiography

CT angiography techniques. Boot camp

Accounting for Imaging Dose

Whole Body CT Protocol Update 2018

MAGNETIC RESONANCE IMAGING (MRI) AND COMPUTED TOMOGRAPHY (CT) SCAN SITE OF CARE

Cigna - Prior Authorization Procedure List: Radiology & Cardiology

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Low-dose and High-resolution Cardiac Imaging with Revolution CT

AMERICAN IMAGING MANAGEMENT

AMERICAN IMAGING MANAGEMENT

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).

Chapter 16 Worksheet Code It

Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography

Tc-99m Sestamibi/Tetrofosmin Stress-Rest Myocardial Perfusion Scintigraphy

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Evidence-Based Management of CAD: Last Decade Trials and Updated Guidelines

MEDICAL POLICY SUBJECT: CORONARY CALCIUM SCORING

Radiology. General radiology department. X-ray

Current trends in virtual colonoscopy

Is computed tomography angiography really useful in. of coronary artery disease?

General Cardiovascular Magnetic Resonance Imaging

Introduction and Background

ROUVIERE Héloïse, DE MEESTER Antoine, DESCAMPS Olivier, NICAISE Grégory, MARCOVITCH Olivier,BADOT Damien, TUTUS Caroline, BENAHMED Ahmed

Computed tomographic pulmonary angiography procedures: Contrast media dilution from the venous to the systemic circulation

CT Colonography. A Radiologist s View of the Colon from Outside-In. Donny Baek, MD

Recent developments in cardiac CT

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

2019 Qualified Clinical Data Registry (QCDR) Performance Measures

Appendix A: Introduction to Imaging Modalities for Which Data Were Collected in the 2017 Imaging Inventory

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

CT Imaging at the Point-of-Care

Case Studies. Any other questions? medicom.us

MR IMAGING OF THE LUMBAR SPINE A TEACHING ATLAS 1ST EDITION

Handzettel 1. CT Contrast Media. Agenda. Contrast Media Definition. Agenda. Why we need contrast media? Agenda

Fast and easy diagnostic imaging from head to toe

Nurse-led Rapid Access Chest Pain Clinic at the Royal Glamorgan Hospital. by Sharon Cassidy/Andrea Gasson

Diagnostic Imaging Providers Privileging Guidelines

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY IN CARDIAC IMAGING

EXPERIMENTAL AND THERAPEUTIC MEDICINE 9: , 2015

Outline. NCRP Scientific Committee 6-2

Transcription:

Utilization Status of SCENARIA at the Diagnostic Imaging Center and Breast Center Koutarou Takahashi MEDIX VOL. 61 P.4 P.7

Utilization Status of SCENARIA at the Diagnostic Imaging Center and Breast Center Koutarou Takahashi Testing Department, Utsunomiya Central Clinic In August 2013, our conventional system, ECLOS 1 (16-channel MDCT), was replaced by the present system, SCENARIA 2 (128-slice, 64-channel MDCT). This system allows imaging of every region of the whole body in 0.35s/rot and also realizes image quality improvement and radiation exposure reduction by applying Intelli IP 3 (Advanced). The following is a report on the utility of SCENARIA at the only diagnostic imaging center and Breast Center in our area. Key Words: SCENARIA, Intelli IP, Coronary CT Angiography, CT Colonography, MPPS 1. Introduction Our hospital, established in 1997, is a diagnostic imaging center. Sixty percent of the examinations conducted here are referrals from hospitals and private-practice physicians (regional medical alliances). We utilize a wide range of modalities including CT, XP, DEXA, MMG, MRI, PET/ CT and PEM (Positron Emission Mammography), and take orders from requesting physicians. The images obtained from the examinations are returned by film or CD as media, or delivered as images via the WEB (a ser- vice in which the distinctive cloud server of our clinic is made public and an account and password are provided to each medical institution with a contract, where examination data for fulfilled orders can be referenced by each approved account). Additionally, given the background of the increased prevalence of breast cancer in Japanese women 1) and the low rate of breast cancer screening (Fig. 1) 2), we established the Breast Center (a specialized examination center Age-adjusted prevalence for a population of 100,000 Breast Fig. 1: Prevalence of breast cancer among Japanese women and screening rates Proportion of women aged 50-69 who underwent mammography screening 2006 100.0 Standard population is the modeled population of Japan for 1985 100% 89.0% Includes cancer in situ 90% 80.0 80% 72.5% 70.7% 70% 60.1% 60.0 60% 56.2% 50% 40.0 40% 30% 23.8% 20.0 20% 0.0 1975 1980 1985 1990 1995 2000 2005 2010 10% 0% United States England New Zealand The Netherlands Australia Japan

for women)in 2013-the first of its kind in Tochigi Prefecture-with the aim of ultra-early detection (Fig. 2). In this paper, we report on the operational status of SCENARIA 2 systems at the diagnostic imaging center and the Breast Center, which had been installed during the establishment of the latter facility. ponents generated during low-dose scanning (Fig. 4). For a scan region of 350mm, we measured the time required for reconstruction when the slice thickness or Recon Index (reconstruction interval)was varied at postreconstruction (Table 1). Although the required calculation time is slightly longer than that for the conventional image reconstruction method, the performance is more than adequate when considering a noise-reduction effect of more than 40% 4) and a reduction in radiation exposure. Thus, the throughput is unlikely to be affected. 120kV, 60mAs, Slab thickness 0mm Fig. 2: Utsunomiya Central Clinic Breast Center 2. Features of SCENARIA (128 slice/64 row MDCT) (1)High-speed scanning at 0.35s/rot and advances toward multi-detector systems The scan time of our previous ECLOS 1 system was 0.8s/rot. However, SCENARIA has enabled high-speed scans of 0.35s/rot not only at the heart but also at truncal areas such as the chest and abdomen. It has also reduced the scan time in association with the increase in the number of detector rows from 16 to 64. With the addition of the cone-beam reconstruction (CORE)method, satisfactory images can now be obtained in which streak artifacts during high-pitch scanning along with motion artifacts are reduced 3) (Fig. 3). Conventional system 0.8s/rot SCENARIA 0.35s/rot Fig. 3: Comparison of motion artifacts between conventional system and SCENARIA (2)Intelli IP 3 Intelli IP (Advanced), which was newly installed in SCENARIA, is a reconstruction method that applies an iterative reconstruction technique and reduces noise com- FBP Intelli IP Lv7 Fig. 4: Comparison between FBP and Intelli IP Table 1: Comparison of reconstruction times Slice thickness or Recon Index / number of images s 10mm/35 5.0mm/70 2.5mm/139 1.25mm/278 0.625mm/556 FBP 12 12 19 30 54 Intelli IP 31 31 39 68 125 (3)CardioConductor 4 (automatic setting of cardiac scan conditions), CardioHarmony 5 (optimal cardiac phase selection) Prior to the installation of SCENARIA, coronary scanning used to be conducted with the 64-row MDCT of a PET/CT system. The scan conditions had been modified on the basis of the patient s heart rate during scanning. However, by using CardioConductor integrated in SCE- NARIA, the scan conditions recommended by the system from the range of heart rates during breath-holding practice are automatically configured. This results in reduced time needed to set the scanning protocol. In addition, the time required to select the optimal cardiac phase was reduced by CardioHarmony. At our hospital, the optimal cardiac phase is primarily determined by a radiological technician. We describe the basic flow of this process below. 1 In the coronary scanning protocol, set conditions after scanning to create images for a total of 6 cardiac

phases-75%, 70%, 45%, 40%, auto-selected diastole, and auto-selected systole- at a slice thickness of 0.625mm and a Recon Index of 5mm. 2 Simultaneously observe the images at the 4 cardiac phases of 75%, 70%, 45%, and 40%; then determine which of the following cardiac phases are optimal-the 75%±5% region around the mid-diastole, or the 45%± 5% region around the systole 5). 3 Simultaneously observe the images at either the cardiac phases of 75%, 70%, and auto-selected diastole or at the 3 cardiac phases of 45%, 40%, and auto-selected systole; then determine the optimal cardiac phase. 4 Depending on the case, reconstruct images at a pitch of 1% around a cardiac phase where the image observed is satisfactory, then select the optimal cardiac phase by editing the ECG waveform. Determination of the optimal cardiac phase is essentially considered complete at step 3 above. The search time is 5min or less, although it varies according to the operator. The optimal cardiac phase is reconstructed at a slice thickness of 0.625mm and a Recon Index of 0.3125mm, and then processed analytically. 3. Operational status of SCENARIA The system was installed in August of 2013 and is used for examinations on a daily basis. Table 2 shows changes in the number of CT examinations over time, from September after installation to the end of April, 2014. When data for the past 3 years are compared, the number at each month after installing SCENARIA shows an increase every year and exceeds 100% relative to the corresponding month of either of the previous two years, with examinations for this fiscal year showing the highest numbers. This suggests an underlying improvement in throughput due to scan time reduction, faster movement of the patient table, and multilingual compatibility. However, considering its performance characteristics, SCENARIA has the capacity to perform at least 32 examinations in an 8-h (480-min)day during examination hours at our hospital, assuming approximately 15min on average per examination. Our hospital mainly relies on regional medical alliances for patients, and radiological technicians assume a central role in actively carrying out strategy as well as working on securing examinations. In addition to the obvi- Table 2: Number of examinations with SCENARIA cases Sep Oct Nov Dec Jan Feb Mar Apr 2011-2012 263 262 254 219 208 212 252 223 2012-2013 240 268 241 224 292 292 328 282 2013-2014 292 313 314 320 284 348 297 348 ous goal of nurturing technicians that understand the performance capabilities of SCENARIA, we are striving to achieve full capacity with regard to the number of examinations by touting the performance capabilities of SCE- NARIA to physicians at other medical institutions (Table 2, Fig. 5). cases 400 350 300 250 200 150 100 50 0 Sep Oct Nov Dec Jan Feb Mar Apr 2011-2012 2012-2013 2013-2014 Fig. 5: Change in number of SCENARIA examinations over time 4. Clinical cases (1)Coronary CT Angiography The main requests are for detailed examinations due to suspected angina or coronary artery stenosis. Previously, scanning was performed with a PET/CT system. Because PET examinations were of a higher priority, the time available for CT examinations limited the number of cases to 2 per day. The installation of SCENARIA made it possible to conduct examinations at any time and also allowed for same-day examinations if patients satisfied requirements such as those regarding renal function, blood pressure, allergies, and meal restrictions. The number of examinations also increased significantly. The scan conditions are 120kV and 175mAs (0.35s/rot) with a beam pitch of 0.2031. The injection conditions for the contrast agent are as follows: an injection rate of 4.0~ 4.6ml/s, with 1mg/kg and 40ml as target injection amounts for the contrast agent and saline, respectively. The injection rate is adjusted so that the time to complete contrast agent injection approximates a target time of 14s. In addition, for examinees with a high heart rate, a beta blocker is injected intravenously based on a standard heart rate (HR)of 75~80bpm during suspended respiration. We perform the conventional scanning for calcium scoring by a prospective scan. On the basis of the results, we then conduct a retrospective scan for contrast-enhanced scan. We use the bolus-tracking method to determine the time to initiate scanning while monitoring the descending

aorta (Fig. 6). The monitoring position is determined by paying attention to arteriosteogenesis. that of the 213 cases, 196 were classified as 3 or 4, with the success rate of scanning simply calculated as 92.0%. For the remaining 8% of cases where evaluation was impossible, the causes included electrocardiogram (ECG)abnormalities due to multiple arrhythmias, sudden elevation of heart rate during the main scan, and artifacts due to heavy calcification. CT value 140 130 120 100 80 60 40 0 5 10 15 20 25 30 35 s Fig. 6: Monitoring by the bolus-tracking method Coronary CT angiography is sometimes unable to yield diagnosable images owing to the timing of contrast agent injection, HR of the patient, cardiac diseases such as arrhythmia, or artifacts. From the reading reports of radiologists, we simply calculate whether diagnosable images are obtained as a measure of the success rate of scanning. The evaluation results of the interpreting radiologist are classified into the following four ratings. 4: The main coronary arteries are well-detected and evaluation is possible 3: Evaluation is possible for most of the main coronary arteries 2: Some of the main coronary arteries cannot be evaluated 1: Evaluation is impossible for the main coronary arteries We investigated a total of 213 cases for successful scanning (Table 3), defined as a rating of 3 or 4 in the 4-level classification described above (Fig. 7). Results showed Table 3: Rating of scanned image Rating Number 4 183 3 13 2 15 1 2 Fig. 7: Example of scanned main coronary arteries (2)CT Colonography Since around 2006, our hospital has been performing CT colonography (hereinafter referred to as CTC)examinations. In September of 2012, we installed an automatic injector system (PROTO CO2L), which is currently being used for prognostic tests for comprehensive medical examinations and screenings as well as for fulfilling orders from medical departments. In a recent case, endoscope insertion during colonoscopy became difficult because of adhesion or complicated coursing of the intestine, which led to transfer of the patient for CTC examination within the same day. Such cases of regional medical alliances have also been increasing. The scan conditions are 120kV and 160~200mAs (0.5s/ rot)with a beam pitch of 1.0781. The prone position and dorsal position are used for scan positioning; in cases with poor colonic distension, an additional scan is performed in the right or left lateral decubitus position. Considering the flow of carbon dioxide gas into the small intestine, scanning in the dorsal position is performed after scanning in the prone position. For positioning, a rectal tube is inserted in the left lateral decubitus position and carbon dioxide insufflation is initiated. The positioning is then changed in the clockwise direction from the left lateral decubitus to dorsal and then prone positions. Furthermore, in the prone position, a towel is placed beneath the chest of the patient to prevent the transverse colon from collapsing. The scan time is approximately 6s per position, and the examination is completed in roughly 10~15min. Before the automatic injector system was installed, colonic distension used to be confirmed in the fluoroscopy room by manually infusing carbon dioxide, after which the patient was transferred to and scanned in an adjacent CT room. With this method, a time lag occurred between carbon dioxide injection and scanning, and adequate distension images often could not be obtained. However, since the installation of the automatic injector system, scanning performed completely within the CT room has become possible and the time lag between carbon dioxide injection and scanning has been eliminated. Moreover, the shorter scan time and faster movement of the patient table has resulted in reduced patient burden, and the increased rotation speed has reduced artifacts from the intestine (Fig. 8).

using the Intelli IP installed in SCENARIA. Going forward, I would like to investigate the extent to which dose may be reduced while maintaining image quality under the guidance of assessments made by radiologists. 6. Conclusion Fig. 8: CT Colonography 5. Future prospects (1)Individualized dose control by modality performed procedure step (MPPS)coordination Since the nuclear accident stemming from the Great Eastern Japan Earthquake, radiation exposure has garnered much public concern, and radiation from medical exposure during diagnostic imaging is no exception. In the US, the American College of Radiology (ACR)operates a radiation dose index management system in which medical institutions throughout the US participate. Dose control is evaluated by comparing data submitted to the ACR from each medical institution with those from other institutions 6). Currently, our hospital is in the process of constructing a dose control system based on MPPS coordination between radiation inf ormation system (RIS) modalities (Fig. 9). One reason for selecting SCENARIA is that it also allows for MPPS coordination. Lowering of radiation dose has become possible by CT PET/CT DEXA RF FPD MMG Information received via DICOM MPPS communication N-CREATE, N-SET from each modality. After analyzing information received at the MPPS server, register in the database. Run application from each client PC and refer to the dose amount of each device. Fig. 9: Dose control TRYFORGateway MPPS server User interface of dose control Client PC Client PC Here, we have reported on the operational status and future prospects of SCENARIA at the diagnostic imaging center and Breast Center. Compared with the conventional ECLOS system, the quality of examinations has increased immeasurably due to the improved device specifications and wide variety of applications. At the same time, the number of examinations has increased. SCENARIA is an indispensable device in our center, which mainly relies on regional medical alliances. By using SCENARIA, which also has wide-ranging response capabilities that go beyond scanning (e.g., individualized dose control by MPPS coordination)as mentioned in 5. Future prospects, we believe that we will be able to provide patient-centered medical treatment. 1 ECLOS, 2 SCENARIA, 3 Intelli IP, 4 CardioConductor, and 5 CardioHarmony are registered trademarks of Hitachi Medical Corporation. References 1) National Cancer Center, Center for Cancer Control and Information Services http://ganjoho.jp/professional/statistics/statistics. html (in Japanese) 2) Ministry of Health, Labour, and Welfare Home Page: Low screening rates in Japan. http://www.gankenshin50.go.jp/campaign_25/outline/low.html (in Japanese) 3) T. Nakazawa et al.: The New Technologies of the Multi-slice CT system SCENARIA. MEDIX, Vol. 55: 45-48, 2011. (in Japanese) 4) T. Goto et al.: Higher Noise Reduction for CT System with Iterative Processing. MEDIX, 56: 43-46, 2012. 5) Y. Suzuki: Throughput and operating procedures of cardiac CT. RT, No. 41 October, 2008. (in Japanese) 6) Japan Medical Imaging and Radiological Systems Industries Association (JIRA)Radiation & Dose Committee: On Trends in Medical Radiation Control, From the standpoint of management systems. http://www.jira-net.or.jp/dicom/file/dicom_2013_ hibaku_management.pdf (in Japanese)