Magnetic Resonance Angiography

Similar documents
MR Advance Techniques. Vascular Imaging. Class II

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

1Pulse sequences for non CE MRA

非對比劑與對比劑增強 MRA. 血管攝影與對比劑 A Course of MRI. 本週課程內容 -MR Angiography (MRA) Unenhanced MRA

Department of Radiology University of California San Diego. MR Angiography. Techniques & Applications. John R. Hesselink, M.D.

MR Imaging with the CCSVI or Haacke protocol

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

MR Flow Imaging in Vascular Malformations Using Gradient Recalled Acquisition

Clinical Applications

Cerebral MR Venography: Normal Anatomy and Potential Diagnostic Pitfalls

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx

Sung Hong Park. M.S. in Electrical Engineering, KAIST, South Korea, Submitted to the Graduate Faculty of

T Clinical Magnetic Resonance Angiography

How I do it: Non Contrast-Enhanced MR Angiography (syngo NATIVE)

MR Angiography in the evaluation of Lower Extremity Arterial Disease

Neuroradiology MR Protocols

Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography

Department of Radiology, Division of MRI, University of Michigan, 1500 E. Medical Center Drive, Ann Arbor, MI , USA

A Magnetic Resonance Imaging Method for

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

NEURO PROTOCOLS MRI NEURO PROTOCOLS (SIEMENS SCANNERS)

Speed, Comfort and Quality with NeuroDrive

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

MRI protocol for post-repaired TOF

MR Advance Techniques. Cardiac Imaging. Class IV

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography

MRI Abdomen Protocol Pancreas/MRCP with Contrast

High-Sensitivity Coil Array for Head and Neck Imaging: Technical Note

Normal MRI Appearance and Motion-Related Phenomena of CSF

MR Advance Techniques. Cardiac Imaging. Class III

Objectives 8/17/2011. Challenges in Cardiac Imaging. Challenges in Cardiac Imaging. Basic Cardiac MRI Sequences

ρ = 4(νp)2 Scale -200 to 200 V = m/s Grad = 34 mmhg V = 1.9 m/s Grad = 14 mmhg Types

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories

Three-Dimensional Time-of-Flight MR Angiography in the Evaluation of Intracranial Aneurysms Treated by Endovascular Balloon Occlusion

High Field MR of the Spine

Cardiovascular MR Imaging at 3 T: Opportunities, Challenges, and Solutions 1

Tips and Tricks of State of the art MRA

Can SCMR CMR protocol recommendations

PHYSICS OF MRI ACQUISITION. Alternatives to BOLD for fmri

Fulfilling the Promise

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It 1

Time-Of-Flight MRA. Faculty Disclosures Vincent B. Ho, M.D. Presentation Objectives. MRA Techniques. Pros and Cons of MRA

Magnetization Preparation Sequences

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

NEUROVASCULAR ANATOMY

醫用磁振學 MRM 肌肉骨骼磁振造影簡介 肌肉骨骼磁振造影. 本週課程內容 General Technical Considerations 肌肉骨骼磁振造影簡介 盧家鋒助理教授國立陽明大學生物醫學影像暨放射科學系

Blood flow assessment in cerebral arteries with 4D flow magnetic resonance imaging

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory

8/4/2016. Optimizing Pediatric Cardiovascular MRI. Disclosure. Outline. Jie Deng, PhD, DABMP, Cynthia Rigsby, MD

Magnetic resonance techniques to measure distribution of cerebral blood flow

Fully Refocused Gradient Recalled Echo (FRGRE): Factors Affecting Flow and Motion Sensitivity in Cardiac MRI

1 Normal Anatomy and Variants

Contrast material enhanced threedimensional

Fat Suppression in the Abdomen

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution

Original Research. Tadateru Sumi, DDS, 1 Misa Sumi, DDS, PhD, 1 Marc Van Cauteren, PhD, 2 Yasuo Kimura, DDS, PhD, 1 and Takashi Nakamura, DDS, PhD 1 *

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015

8/4/2016. MRI for Radiotherapy: MRI Basics. Nuclear Magnetic Resonance. Nuclear Magnetic Resonance. Wilson Miller

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord

Advanced Vascular Imaging: Pulsatile Tinnitus. Disclosures. Pulsatile Tinnitus: Differential Diagnosis. Pulsatile Tinnitus

ACR MRI Accreditation: Medical Physicist Role in the Application Process

Assessment of Adipose Tissue from Whole Body 3T MRI Scans

Ultrasound Physics & Terminology

Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique

Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T

Orthopedic Hardware Imaging Part II: MRI v. Metal

The study of local hemodynamics within anatomically complex

Master Thesis in Radiation Physics 09/10 Annie Olsson. Supervisors: Frank Risse Lars E. Olsson. Imaging centre AstraZeneca R&D Mölndal

The Extracranial Facial Nerve: High Resolution Three-Dimensional Fourier Transform MR Imaging

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model

Congenital Heart Disease

Correction of CSF Motion Artifact on MR Images of the Brain and Spine by Pulse Sequence Modification: Clinical Evaluation

Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla

Echelon Oval provides a robust suite of leading musculoskeletal imaging capabilities for detailed assessment of all anatomy for your most challenging

In vivo diffusion tensor imaging (DTI) of articular cartilage as a biomarker for osteoarthritis

KNEE ALIGNMENT SYSTEM (KAS) MRI Protocol

Cover Page. The following handle holds various files of this Leiden University dissertation:

Why Talk About Technique? MRI of the Knee:

Endovascular treatment of intracranial aneurysms with detachable

Optimized phase contrast MRV technique outperforms timeof-flight in the diagnosis of cerebral venous thrombosis

Renal vascular evaluation with 64 Multislice Computerized Tomography Daniela Stoisa, Fabrizzio E. Galiano, Andrés Quaranta, Roberto L.

Flow Quantification from 2D Phase Contrast MRI in Renal Arteries using Clustering

Personal use only. MRI Metal Artifact Reduction: Shoulder Implants and Arthroplasty. Reto Sutter, MD

Objectives. CMR Volumetric Analysis 8/25/11. CMR Volumetric Analysis Technique. Cardiac imaging plane acquisition. CMR Volumetric Analysis

Personalized Solutions. MRI Protocol for PSI and Signature Guides

A WORLD OF KNOWLEDGE FOR MR TECHNOLOGISTS & RADIOGRAPHERS

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique

BioMatrix Tuners: CoilShim

Subject Index. Automated triggering 88 AVM 128, 129

Planimetric and continuity equation assessment of aortic valve area (AVA): comparison between cardiac magnetic resonance (cmr) and echocardiography

Rapid Quantitation of High-Speed Flow Jets

Transcription:

Magnetic Resonance Angiography 1

Magnetic Resonance Angiography exploits flow enhancement of GR sequences saturation of venous flow allows arterial visualization saturation of arterial flow allows venous visualization 2

MR Angiography MRA is not a look at the actual anatomy. MRA is a physiological record of blood flow. If there is no blood flow there will be no MR angiographic visualization of the vessel. 3

MRA MRA ARTERIOGRAM MRA is a record of blood flow. Any disturbance in blood flow will be recorded in the image. Small arrow - faster flowing blood. Large arrow/lighter signal - slower flowing blood. 4

Introduction MR angiography can provide screening of the vascular anatomy of the head, neck, body, and periphery. Clinical information should be supplemented with conventional MR images 5

Time-of-Flight Time-of-Flight A vascular imaging technique usually for fast flow. The slab or slice (2D vs 3D) is saturated by repeated RF excitation. The saturation of the spins cause tissues to be darkened. Unsaturated blood entering the slab or slice will not be saturated and therefore will be bright. This is also called a rephase technique. 6

Time-of-Flight TOF is the time it takes for blood to flow through an imaging slice and the effect it has on the signal from blood. When using spin-echo pulses time-of-flight blood is dark. When using gradient echo sequences time-of-flight bright blood results. Time-of-flight refers to the effect of allowing blood to flow into or out of a slice between excitations. 7

Time-of-Flight 8

2D TOF GR images used short TR (~ 20-40 msec) very short TE shortest TE times minimize intravoxel dephasing resulting in maximum flow effects small to medium flip angles 9

2D Time Of Flight (TOF) Benefits Both arteries and veins can be visualized. Shorter acquisitions times lend itself to abdominal vascular imaging using breath-hold techniques. Background tissue suppression is superior to 3D TOF imaging. Extremely slow flow velocity blood can be adequately visualized. Large area of coverage 10

2D Time Of Flight (TOF) Disadvantages Resolution limitations (smaller available slice thickness) cause an increase in partial volume effects. MIP projections tend to suffer due to thicker individual slices. Longer TE times and larger voxel volumes may result in an inappropriate decreased in signal following an area of stenosis. If the vessel is not quite perpendicular to the slice, or if it changes directions within the slice, saturation of the vascular signal occurs. 11

3D TOF 3D TOF imaging volumetrically acquires contiguous thin slices by the usual 3DFT method. 3D TOF imaging is the method of choice for imaging fast flowing blood that does not particularly follow a straight course. The TE times tend to be shorter than with the 2D TOF method resulting in minimized flow-turbulent related artifacts. In addition, high resolution images can be acquired lending easily to high resolution MIP images. 12

3D Time-of Flight 13

3D Time-of-Flight 14

3D TOF Benefits High resolution vascular imaging High SNR Rapid acquisition of 3-5 cm area High resolution MIP images possible 15

3D TOF Disadvantages Blood must traverse the volume quickly in order not to become saturated along with the background tissue (saturation of in-plane flow). Short T1 tissues in the background may not become saturated completely thereby simulating a vessel. Coverage 16

Phase Contrast Phase Contrast A vascular imaging technique where sets of images are encoded with different phase velocities and are then subtracted. Background subtraction is complete. This technique is used for slow flow as in the extremities. This is also known as phase shift. Available 2D and 3D imaging 17

Phase Contrast / PSI Angiography The greater the velocity of motion, the more phase shift, and the brighter the appearance of blood in the image. Therefore, complete suppression of stationary tissue can be achieved with PC. 18

Phase Contrast Angiography In phase contrast (PC) MRA, signal is based on the phase gained (or lost) as the spins move through a magnetic field gradient. 19

Phase Contrast Angiography Spins that are moving in the same direction as a magnetic field gradient develop a phase shift that is proportional to the velocity of the spins. This is the basis of phase-contrast angiography. 20

Phase Contrast Angiography This phase is subtracted from the background phase to determine the portion of the phase that is only due to motion. 21

Velocity Encoding (VENC) The velocity of blood flow is defined by the distance traveled between the positive and negative lobe of the velocity-encoding gradient (a 180 phase shift will produce maximum signal intensity). It is shown in cm/sec. 22

VENC The VENC value chosen will cause the blood flow traveling at exactly that value, in the direction of the positive lobe, to be assigned the maximum pixel value. Blood flow in the opposite direction will be dark. Choose a VENC value slightly higher than the predicted velocity of blood being observed to reduce the possibility of aliasing. 23

Phase Contrast Advantages Sensitive to flow within FOV Background suppression is superior Can evaluate blood flow velocity Can evaluate blood flow direction (magnitude and phase images) 24

Phase Contrast Disadvantages Scan times are long due to acquisition methods (2 additional sets of images acquired). Less sensitive to unpredictable flow 25

Contrast enhanced MRA Often in-plane flow and motion artifacts can degrade MRA images. Contrast MRA has therefore become the standard in MRA imaging. These sequences are generated with T1 weighted gradient echo images with bolus injections of gadolinium. Dynamic imaging are acquired before, during and after injection timed based on the vascular consideration. 26

Blood Flow 27

LAMINAR FLOW Blood flow that has a parabolic profile, in which the velocity of the protons in the center of the vessel is greater than the velocity of protons moving adjacent to the vessels walls. 28

Laminar Flow Laminar flow is usually found in veins and small arteries. MRA most accurately represents laminar flow. 29

Scan Parameters GRE sequences are required for bright blood Thin slices decrease the velocity necessary for 100% inflow of unsaturated blood as well as improve resolution Flow compensation refocuses motion related dephasing resulting in a brighter signal 30

Scan Parameter Optimization TR TR must be kept short to minimize acquisition time. However, TR and flip angle are complimentary and cannot exceed a maximum value without compromising the time of flight effect. 31

TE s Scan Parameter Optimization Must be kept short to avoid loss of signal from turbulence. If different TE choices are available, TE will be chosen by size of vessel to be imaged and pathology expected. 32

Scan Parameter Optimization Flip Angle Flip angle and TR for adequate suppression of background tissues. Flip Angle also will affect the saturation of the inflowing blood. The longer the vessel must remain unsaturated, the shorter the FA will need to be (e.g., the coronal or para-coronal acquisition of the proximal carotid arteries. If the FA is too large, the time of flight effect will be reduced. 33

Voxel size Scan Condition Optimization The voxel is the cubic portion of data as prescribed by the slice thickness and matrix. Smaller voxels reduce the turbulent signal loss as well as provide higher resolution of the vessels. 34

Slab thickness Scan Condition Optimization The slab thickness should never be thicker than the vessel segment of interest. The size of the slab is also related to the direction of flow. If the slab is perpendicular to the direction of flow in the vessel of interest, the distance the blood must flow is an essential consideration. Signal from blood flow will be saturated out of the slab if too thick. 35

Multiple Overlapping Thin Slice or Slab Acquisition (MOTSA) Multiple 2 to 3 cm thick 3D-TOF slabs covering the anatomy of interest. MOTSA combines the best features of 2D- and 3D-TOF MRA, because it has the unlimited coverage of 2D-TOF and the high spatial resolution of 3D-TOF. 36

Maximum Intensity Projection Algorithm The maximum intensity projection algorithm is responsible for projecting the brightest pixels, from an anatomical stack of 2D or 3D base images, onto a plane, to generate an image of the projected view of the vessel(s) of interest. 37

Maximum Intensity Projection (MIP) 38

MRA Optimization Saturation bands are planar regions parallel to and adjacent to imaging planes or slabs. Within them blood that we do not want to see is saturated with repeated RF signals before it enters the imaging volume, emitting no signal. 39

Spatial Saturation With MRA To limit a study to either the arteries or veins, a saturation pulse may be added to the MRA pulse sequence to eliminate the inflowing blood from irrelevant vessels. 40

Saturation Bands To saturate Venous Flow - from heart If below heart: inferior presaturation band If above heart: superior presaturation band To saturate Arterial Flow - from heart If below heart: superior presaturation band If above heart: inferior presaturation band 41

Saturation Bands Walking saturation bands Places a new saturation band adjacent to each new imaging plane or slab as it is acquired in sequence so that each scan has been presaturated. More sophisticated placements include use of multiple bands and placement at oblique angles to optimize presaturation and exclusion of signals. 42

MRA Optimization Two main areas that require great care when producing MRA images are the carotid bifurcation and the circle of Willis. The common carotid artery on the left is usually the second major vessel originating from the aortic arch, whereas on the right side, the common carotid arises from the proximal innominate artery. The common carotid arteries usually bifurcate into the external and internal carotid arteries. 43

MRA Optimization - Carotids The bifurcations are important to visualize as the internal carotid arteries provide major blood flow to the brain. Turbulence and highvelocity blood flow effects produce complex flow patterns that can make MRA difficult. 44

Circle of Willis The best way to visualize the circle of Willis is to position it entirely within the middle slab of a three-slab MOTSA sequence. Avoid placing the interslab interface cross the circle of Willis. Any time-of-flight apparatus can produce a circle of Willis study without MOTSA using a stack of 2D or a 3D slab acquisition. Phase-contrast MRA may be used to show anatomic relationships and can provide information about the direction and velocity of flow (normal and abnormal) in the COW. 45

MOTSA through Circle of Willis MOTSA through a normal Circle of Willis. The vessels that form the circle of Willis include: two internal carotid arteries horizontal segments of the proximal and anterior cerebral arteries anterior cerebral arteries two posterior communicating arteries basilar artery 46