Copyright 2007 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, volume 6514, Medical Imaging

Similar documents
doi: /

Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008:

doi: /

Automatic Ascending Aorta Detection in CTA Datasets

By choosing to view this document, you agree to all provisions of the copyright laws protecting it.

Copyright 2007 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, volume 6514, Medical Imaging

Copyright 2007 IEEE. Reprinted from 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, April 2007.

Computer based delineation and follow-up multisite abdominal tumors in longitudinal CT studies

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008:

Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008:

AUTOMATIC RETINAL VESSEL TORTUOSITY MEASUREMENT

Automatic cardiac contour propagation in short axis cardiac MR images

A numerical 3D coronary tree model

Correlation of Cardiac CTA to Conventional Cardiac Angiography in Diagnosing Coronary Artery Stenosis in a Community Based Center

LUNG NODULE SEGMENTATION IN COMPUTED TOMOGRAPHY IMAGE. Hemahashiny, Ketheesan Department of Physical Science, Vavuniya Campus

IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 25, NO. 4, APRIL

Automatic Classification of Calcification in the Coronary Vessel Tree

Combined Anatomical and Functional Imaging with Revolution * CT

Adapted Transfer Function Design for Coronary Artery Evaluation

Coronary angiography is the standard way of visualizing

ANALYSIS OF SOFT PLAQUE DETECTION METHODS IN CTA IMAGES

Automated Volumetric Cardiac Ultrasound Analysis

Cover Page. Author: Wang, Ancong Title: Automatic quantification of intravascular optical coherence tomography Issue Date:

Detection and Visualization of Endoleaks in CT Data for Monitoring of Thoracic and Abdominal Aortic Aneurysm Stents

Computer-Assisted Navigation on the Arrested Heart during CABG Surgery

Daniel da Silva Diogo Lara. Arnaldo Albuquerque de Araújo

Copyright 2009 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 7260, Medical Imaging 2009:

Voxar 3D CardiaMetrix. Reference Guide

AUTOMATIC MEASUREMENT ON CT IMAGES FOR PATELLA DISLOCATION DIAGNOSIS

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

MR Advance Techniques. Vascular Imaging. Class II

Copyright 2003 IEEE. Reprinted from IEEE Transactions on Medical Imaging, vol. 22, no. 10, pp , Oct

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

Tumor cut segmentation for Blemish Cells Detection in Human Brain Based on Cellular Automata

Diagnosis of Liver Tumor Using 3D Segmentation Method for Selective Internal Radiation Therapy

Lung structure recognition: a further study of thoracic organ recognitions based on CT images

CT angiography techniques. Boot camp

Fulfilling the Promise

A VIRTUAL TRAINING SYSTEM FOR CHEST RADIOGRAM INTERPRETATIONS USING ANATOMICAL HUMAN STRUCTURES IN HIGH-RESOLUTION CT IMAGES

Image Assistance in TAVI Why CT? Won-Jang Kim, MD, PhD Clinical Assistant Professor of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea

Automatic recognition of lung lobes and fissures from multi-slice CT images

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

doi: /

Magnetic Resonance Angiography

2D-Sigmoid Enhancement Prior to Segment MRI Glioma Tumour

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Lecture 11: Port placement in robot-assisted minimally invasive surgery

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Imaging Strategies for Endovascular Cardiovascular Procedures and Percutaneous Aortic Valves. Roy K Greenberg, MD

A Pattern Classification Approach to Aorta Calcium Scoring in Radiographs

(EU), FACC (USA), FSCAI (USA)

Cardiac Agatston Scoring

Lesion-Specific Coronary Artery Calcium Quantification for Predicting Cardiac Event with Multiple Instance Support Vector Machines

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

#1 G.S. Kassab Mathematical modeling of coronary arterial tree

LUNG NODULE SEGMENTATION FOR COMPUTER AIDED DIAGNOSIS

Lung Region Segmentation using Artificial Neural Network Hopfield Model for Cancer Diagnosis in Thorax CT Images

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

X-Ray & CT Physics / Clinical CT

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Cardiac CTA Prospective Gating Broad Beam

b. To facilitate the management decision of a patient with an equivocal stress test.

Biases affecting tumor uptake measurements in FDG-PET

Alessandro Albonico Philips

Assignable revenue codes: Explanation of services:

Radiation Safety Abbott Vascular. All rights reserved.

New algorithm for detecting smaller retinal blood vessels in fundus images

Image processing for cardiac and vascular applications

ANALYSIS AND DETECTION OF BRAIN TUMOUR USING IMAGE PROCESSING TECHNIQUES

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Automatic Segmentation of Jaw Tissues in CT Using Active Appearance Models and Semi-automatic Landmarking

PET in Radiation Therapy. Outline. Tumor Segmentation in PET and in Multimodality Images for Radiation Therapy. 1. Tumor segmentation in PET

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

Left Ventricle Segmentation from Heart MDCT

Disclosures CORONARY CALCIUM SCORING REVISITED. Learning Objectives. Scoring Methods. Consultant for M2S, Inc. Coronary Calcium Scoring: Software

BronCare: clinical multimedia system for new therapies assessment in asthma

Assignable revenue codes: Explanation of services:

Left main coronary artery (LMCA): The proximal segment

Construction of 4D Left Ventricle and Coronary Artery Models

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique

Cardiac Computed Tomography

Form 4: Coronary Evaluation

Increased tortuosity of pulmonary arteries in patients with pulmonary hypertension in the arteries

Noninvasive Coronary Angiography with 16 Detector Row CT: Effect of Heart Rate 1

arxiv: v1 [cs.cv] 9 Oct 2018

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2014 February 07.

Coronary Artery Disease - Reporting and Data System (CAD-RADS)

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Original. Stresses and Strains Distributions in Three-Dimension Three-Layer Abdominal Aortic Wall Based on in vivo Ultrasound Imaging

Form 4: Coronary Evaluation

Fast Automatic Detection of Calcified Coronary Lesions in 3D Cardiac CT Images

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Computer Assisted Coronary CT Angiography Analysis

HipNav: Pre-operative Planning and Intra-operative Navigational Guidance for Acetabular Implant Placement in Total Hip Replacement Surgery

Doctoral Dissertation

Transcription:

Copyright 2007 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, volume 6514, Medical Imaging 2007: Computer Aided Diagnosis and is made available as an electronic reprint with permission of SPIE. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.

Segmentation of coronary arteries from CT angiography images Sergei V. Fotin a, Anthony P. Reeves a, Matthew D. Cham b, Claudia I. Henschke b and David F. Yankelevitz b a School of Electrical and Computer Engineering, Cornell University, Ithaca, NY 14853, USA; b Department of Radiology, New York-Presbyterian Hospital-Weill Cornell Medical Center, New York, NY 10021, USA ABSTRACT We present an automated method for delineation of coronary arteries from Cardiac CT Angiography (CTA) images. Coronary arteries are narrow blood vessels and when imaged using CTA, appear as thin cylindrical structures of varying curvature. This appearance is often affected by heart motion and image reconstruction artifacts. Moreover, when an artery is diseased, it may appear as a non-continuous structure of widely varying width and image intensity. Defining the boundaries of the coronary arteries is an important and necessary step for further analysis and diagnosis of coronary disease. For this purpose, we developed a method using cylindrical structure modeling. For each vessel segment a best fitting cylindrical template is found. By applying this technique sequentially along the vessel, its entire volume can be reconstructed. The algorithm is seeded with a manually specified starting point at the most distal discernible portion of an artery and then it proceeds iteratively toward the aorta. The algorithm makes necessary corrections to account for CTA image artifacts and is able to perform in diseased arteries. It stops when it identifies the vessels junction with the aorta. Five cardiac 3D CT angiography studies were used for algorithm validation. For each study, the four longest visually discernible branches of the major coronary arteries were evaluated. Central axes obtained from our automated method were compared with ground truth markings made by an experienced radiologist. In 75% of the cases, our algorithm was able to extract the entire length of the artery from single initialization. Keywords: coronary arteries, segmentation, computer-assisted diagnosis, CT angiography 1. INTRODUCTION According to the American Heart Association, heart disease is the leading cause of death nationwide. Atherosclerosis, a condition in which one or more plaques form in the arteries, can cause partial or complete blockage of blood flow through the artery. Recent developments in CTA imaging techniques allow for the acquisition of three-dimensional volumetric images of the entire heart region. These images are vital in obtaining precise information about the structure of the coronary artery tree and additionally, help to make more accurate diagnosis. 1, 2 In this work we focus on automated reconstruction of coronary arteries from CTA images. Defining the structure of the coronary artery is the first step toward the automated diagnosis of coronary artery disease. Certain features of coronary arteries and cardiac CT imaging introduce difficulties and must be addressed in the design of an automated method. Coronary arteries are very narrow blood vessels and when imaged using CTA (Figure 1), are very sensitive to image noise artifacts, which make them harder to segment. Moreover, the profiles of the blood vessels on cardiac CT images are often affected by stairstep artifacts caused by limitations of modern CTA acquisition techniques; 3 currently cardiac CT images are taken by during several consecutive cardiac cycles. Spatial deviations of the heart position occur between the acquisition cycles and cause displacements as shown in Figure 2. Figures 3-7 illustrate different issues with appearance of a coronary artery on a cardiac CTA image. Geometric sketches at the right side are supplemented with light shaded three-dimensional visualizations of example Send correspondence to Sergei V. Fotin, e-mail: svf3@cornell.edu, phone: 1 607 255 0963 Medical Imaging 2007: Computer-Aided Diagnosis, edited by Maryellen L. Giger, Nico Karssemeijer, Proc. of SPIE Vol. 6514, 651418, (2007) 1605-7422/07/$18 doi: 10.1117/12.707810 Proc. of SPIE Vol. 6514 651418-1

Figure 1. CTA image slice and four major branches: RCA - right coronary artery, LAD - left anterior descending artery, DIAG - its first diagonal branch, LCX - left circumflex artery. Figure 2. Coronal reconstructions of heart region shows stairstep artifacts. White lines on the right image denote borders between different cardiac cycles. coronary artery segments obtained by clipping the surrounding region and applying intensity threshold. Figure 3 shows a typical segment that is without issues and is simple to track. Figure 4 shows the effect of the stairstep artifact that interrupts the continuity of a vessel image. The intensity of the vessel may change due to factors such as non-uniform distribution of contrast medium, internal calcification and soft plaque. With a change in intensity a segment of the artery may be below the threshold value and therefore not be detected. Figure 5 shows how intensity drop may cause the discontinuity. Occasionally, a coronary artery lies very close to another blood vessel or heart chamber of a similar intensity. Due to contrast medium noise, the artery may appear to have leaked into it as shown in Figure 6. Figure 7 shows a sharp turn of a coronary artery which is not peculiar to large blood vessels. Moreover, like any other blood vessels, coronary arteries have branching points that introduce a problem of choosing the correct path for a tracking-based method. Figure 8 shows an example of such a bifurcation point. An ideal algorithm should handle all the situations stated above. An extensive overview of different vessel segmentation methods is presented in Kirbas et al, 4 however none of the methods addressed all the issues that are particular to the coronary arteries in cardiac CTA imaging. An approach that is based on statistical classification of heart regions and active contour models is presented by Yang et al; 5 preliminary experiments made on one case demonstrate promising results. The method proposed by Lavi et al 6 tracks the arteries using front-propagation technique and does the segmentation of the aortic root. The accuracy of the algorithm was assessed by the clinicians grades as a function of image quality. Boldak 7 employed a moment-based tracking approaches that use the local image information to determine vessel direction and includes sophisticated procedures for returning the algorithm to the correct path. Work of Wink et al 8 reports a general method for segmentation of contrast enhanced blood vessels. To navigate a path along the vessel it uses two-dimensional cross-section information. While it is sufficient for segmentation of relatively large blood vessels it may not be enough in case of small and noisy coronary arteries. Methods similar to one reported by Olabarriaga et al 9 and based on minimum-cost path and vessel-enhancement filters are gaining popularity. Though their experiments were done on conventional CT images, the same technique may be promising for CTA as well. However all these methods need to be validated carefully against cases with heart motion artifacts including discontinuities. 2. METHOD An automated method for reconstruction of a vessel s central axis is presented. It is direct and does not require image pre-processing or pre-segmentation of any anatomical parts. It involves manual selection of seed points, iterative prediction of vessel behavior and search of best fitting cylindrical models to determine the next axis point. The algorithm starts from the most distal point of a specified artery and proceeds against the direction of blood flow until it locates the vessels junction with the aorta. Proc. of SPIE Vol. 6514 651418-2

Figure 3. Typical segment of a coronary artery. Figure 4. Vessel image affected by stairstep artifact is one of the major challenges. H 4 'H_ Figure 5. Gap caused by sudden drop of image intensity (threshold of 100 HU is applied before visualization). Partial template match and intensity threshold selection allow to overcome it. Figure 6. Adjacent structure of high intensity. Preserving direction of the previous segment helps to choose correct path. Figure 7. Sharp turn. Adjusting the size of the template and angle selection scheme allows to pass them with suitable precision. Figure 8. Vessel bifurcation point. Problem of choosing the correct path is solved by following the artery against blood flow direction. Proc. of SPIE Vol. 6514 651418-3

Not reached segment Template Orientation of a template H B Extracted segment B D A A Figure 9. Search the template that best matches a segment of the artery. Initial template parameters are obtained from the previously extracted segment. Figure 10. Specifying direction: α (zenith) and β (azimuth) determine the orientation of a template in space. The cylindrical template matching model can tolerate a certain degree of image noise and heart motion artifacts. Usually, injected medium makes coronary arteries more contrast on a CT scan with respect to surrounding tissues, thus, in the general case, the tracing procedure should go in the direction of the highest intensity. To overcome the problem of changing intensity, a flexible local scheme that automatically selects the threshold for each coronary vessel segment was used. The problem with vessel bifurcations was avoided by forcing the algorithm to proceed against the direction of the blood flow. The algorithm preserves the direction of the already extracted central axis while looking for a template for the next segment. At the same time, it is able to trace the arteries making sharp turns. An angle search space selection procedure was included in the algorithm to account for ambiguous conditions. Finding the best fitting model for each artery segment is an optimization problem. At step n, among all cylindrical templates {t i (n)} with orientation α, β, diameterd, height h, and intensity threshold I th,wesearch for the one t best (n), that best matches image region S: t best (n) = arg max t i(n) {R(t i(n),s)}, t i (n) =f[α, β, d, h, I th,t best (n 1)], where R(t i (n),s) is the template-image matching metric which computes the fraction of volume within the image region enclosed in the template that has an intensity above I th. Certain constrains of intensity threshold, orientation and size of the template are applied based on anticipated vessel behavior. 2.1. Formal algorithm description Algorithm 1 was implemented as a solution to the optimization problem stated above. The first step for the algorithm is manual initialization. A user specifies two seed points A and B denoting placement and direction of the starting artery segment. Seed point A is the first visually discernible point belonging to the central axis. Seed point B is selected at a distance approximately equal to two diameters from the point A. Part AB of the vessel must be chosen at an approximately straight segment of the vessel. Once the segment AB has been extracted, we need to find the next segment of the artery. We start to search for a cylindrical template originating at point B that best matches the real image region as shown in Figure 9. This template should have the direction close to AB but is allowed to deviate to accommodate vessel turns. Deviations in space from the direction AB can be specified by two angles: α (zenith) and β (azimuth) as shown at Figure 10. Selection of a proper search range for α is very important. While too small a range of α prevents the algorithm from following the sharp vessel turns, too large a range may cause the algorithm to turn in the wrong direction. Proc. of SPIE Vol. 6514 651418-4

Next point Aorta Extracted segment B 0.75H H Coronary artery A Figure 11. Next axis point is located at the distance equal to three quarters of the best matching template to prevent the algorithm from going off road. Figure 12. Toomanymatchingtemplatesisagood indication that the aorta has been reached. Initially we set the diameter D of the templates to be less than the diameter of the previously extracted segment in order to account for possible vessel narrowing. The height of the template is always chosen to maintain a constant template aspect ratio: H = r aspect D. While searching for best fitting template we compute the ratio R(t) = M(t)/V (t) of the template region volume M(t) having intensity above a certain threshold I th to the volume V (t) of the template. Since the coronary arteries usually have image intensity higher than surrounding tissues, higher values of R(t) would favor the true vessel direction on the image. If there are too many templates with high value of R(t), this means that the vessel diameter has increased and the same search procedure is repeated for a template with a slightly increased diameter. If the diameter increases more than σ max times relative to the diameter of the previous segment, the algorithm terminates. A significant jump in the diameter value usually means that the coronary artery joined with the aorta as shown in Figure 12. In contrast, if we find only templates with a low ratio R(t), this may be caused by either an intensity drop or a sharp turn. Therefore, first the search procedure is repeated with a smaller intensity threshold I th, second it is repeated with an extended α search range. Such adjustments are made until the template with high enough value of R(t) is found. If the intensity drop is too much relative to the average intensity of the 27-voxel neighborhood of point B, the algorithm terminates. If the template is not found even within the extended search range, the algorithm also terminates. Usually, these situations happen in case of a severe vessel discontinuity. Once the best fitting template is found it is put on top of the already extracted segment as shown in Figure 11. The next axis point is placed at a distance of 0.75H from point B to ensure that the axis lies within the vessel. Then the entire procedure of the search is repeated for the next segment of the artery. To evaluate the quality of the algorithm, its output was compared with manual markings made by an experienced radiologist. Five cardiac 3D CT angiography image sets (64-slice CT scanner GE LightSpeed VCT, slice thickness: 0.625 mm, in-plane resolution: 0.48...0.52 mm) were used in the experiment. For each study, the four longest visually discernible branches of the major coronary arteries imaged at the most relaxed temporal stage of the heart cycle were considered. 3. RESULTS The results of the artery delineation can be represented as a chain of best fitting cylindrical templates stitched together as shown in Figure 13. Automatically and manually extracted central axes for one of the cases are shown in Figure 14. Black circles represent the markings created by our automatic method and gray circles Proc. of SPIE Vol. 6514 651418-5

Algorithm 1 Coronary artery reconstruction A, B points of initial segment d initial diameter I max maximum intensity threshold I drop allowed intensity drop relatively to previous segment I step intensity iteration step δ min, δ max starting and ending diameter coefficients δ st diameter iteration step α st, α range step and range for zenith search α ext extended value of starting zenith β st, β range step and range for azimuth search r aspect template height to diameter aspect ratio r match template match ratio t tmm too many matches ratio next axis point distance coefficient t step 1: α start 0 initializelowerboundofzenithsearchrange 2: I th I max set intensity threshold 3: for δ = δ min to δ max step δ st do iterate diameter coefficients 4: D δ d obtain diameter for the template 5: H r aspect D calculate template height 6: T initialize set of templates 7: for α = α start to α start + α range step α st do iterate through possible zeniths 8: for β =0toβ range step β st do iterate through azimuths 9: T T t(a, B, α, β, D, H) add template to the set 10: V (t) {v t S} establish the set of voxels within the template 11: M(t) {v t S : I(v) >I th } find the subset of high intensity voxels 12: R(t) M(t) / V (t) calculate matching metrics 13: end for 14: end for 15: T fit {t T : R(t) >r match } find subset of best fitting templates 16: if T fit = then if no fitting templates found 17: I th I th I step first, decrease threshold intensity 18: if I th >I 27 (B) I drop then if intensity is not too low 19: go to 3 reinitialize diameter and restart the search 20: end if 21: if α start =0then 22: α start α ext second, extend zenith search space 23: go to 2 reinitialize intensity, diameter and restart the search 24: end if 25: stop no matches (discontinuity) 26: end if 27: if T fit <t tmm T then if not too many matching templates 28: t best arg max t Tfit {R(t)} get the best match 29: A B mark the segment as extracted 30: B B + t step vector(t best ) get next axis point 31: d D remember diameter 32: go to 1 process next segment 33: end if 34: end for 35: stop too many matches (reached aorta) Proc. of SPIE Vol. 6514 651418-6

II, Figure 13. Modeled segment of LAD (20% of full length): cylinders of different shades represent best matching templates stitched together Figure 14. Same segment of the artery: comparison of automatically (black) and manually (gray) marked axis (diameter of each circle is 1mm) Figure 15. Volume rendering of the heart region with automatically extracted RCA and LAD (marked white) represent the manual marks. The diameter of each circle is 1 mm. The algorithm result displayed with respect to the heart is shown in Figure 15. The average distance between the segments along the entire artery length was measured. In all cases the algorithm was able to reconstruct the central axis within the distance of 1 mm from the marked ground truth location. In 15 out of 20 vessels, the algorithm identified the entire length of the artery with a single manual initialization. In the remaining five it could extract only a portion of the artery. However, the algorithm could be manually reseeded from the point where it stopped, and when this was done, it was able to complete the delineation procedure. Ratios of extracted segment to visually discernible artery lengths are shown in Table 1. Table 1. Portions of artery branches extracted from a single manual initialization. CASE CX0001 CX0017 CX0018 CX0019 CX0020 LAD 1.0* 1.0* 1.0 1.0 1.0 RCA 1.0 0.3 1.0 1.0 1.0 LCX 0.3 0.2 1.0 1.0 0.9 DIAG 1.0 1.0 1.0 1.0 0.6 * - cases used for selection of the algorithm parameters In four out of five cases of premature completion, the algorithm stopped at a point of discontinuity caused by cardiac motion, an example of which is shown in Figure 16. In the remaining case, the algorithm incorrectly identified the tangent boundary of the heart as the junction point with the aorta as shown in Figure 17. Proc. of SPIE Vol. 6514 651418-7

Figure 16. RCA: Example of premature completion due to significant discontinuity caused by stairstep artifact. Figure 17. LCX: Significant drop of image intensity nearby one of the heart chambers. Algorithm erroneously decides that aorta is reached. 4. CONCLUSION We designed an automated method that can extract the central axes of the coronary arteries from CTA images. Preliminary results obtained in this work indicate that our method can be used to approach this goal. The algorithm was specifically designed to handle coronary arteries that can be affected by disease, noise, heart motion and image reconstruction artifacts. The cylinder modeling approach allows us to extract very thin segments barely seen on a CT scan. Because of the flexibility and adaptive nature of the algorithm, it was able to track arteries of different sizes and curvatures, containing calcifications, soft plaque and surgical stent implants. The template matching scheme could even tolerate certain degree of stairstep artifacts by preserving the orientation of the vessel in the same direction. However, additional work needs to be done to develop a more robust system that overcomes the challenges of complex cases due to either complex anatomy or technical issues. REFERENCES 1. B. H. Thompson and W. Stanford, Update on using coronary calcium screening by computed tomography to measure risk for coronary heart disease, The International Journal of Cardiovascular Imaging 21, pp. 39 53, February 2005. 2. A. F. Kopp, A. Kuttner, T. Trabold, M. Heuschmid, S. Schroder, and C. D. Claussen, Multislice CT in cardiac and coronary angiography, British Journal of Radiology 77, 2004. 3. L. P. Lawler, H. Pannu, and E. Fishman, MDCT evaluation of the coronary arteries, 2004: how we do it data acquisition, postprocessing, display, and interpretation, American Journal of Roentgenology 184(5), pp. 1402 12, 2005. 4. C. Kirbas and F. Quek, A review of vessel extraction techniques and algorithms, Computing surveys 36(2), pp. 81 121, 2004. 5. Y. Yang, A. Tannenbaum, and D. Giddens, Knowledge-based 3D segmentation and reconstruction of coronary arteries using CT images, in 26th Annual International Conference of the Engineering in Medicine and Biology Society, 3, pp. 1664 1666, September 2004. 6. G. Lavi, J. Lessick, P. Johnson, and D. Khullar, Single-seeded coronary artery tracking in CT angiography, in Nuclear Science Symposium Conference Record, 5, pp. 3308 3311, October 2004. 7. C. Boldak, Extraction et caracterisation 3D des reseaux vasculaires en imagerie scanner multibarette: Application aux reseaux des membres inferieurs et des coronaires. PhD thesis, Universite de Rennes, 2003. 8. O. Wink, W. J. Niessen, and M. A. Viergever, Fast Delineation and Visualization of Vessels in 3D Angiographic Images, IEEE Trans. Med. Imaging 19(4), pp. 337 346, 2000. 9. S. Olabarriaga, M. D. Breeuwer, and W. J. Niessen, Minimum Cost Path Algorithm for Coronary Artery Central Axis Tracking in CT Images, Lecture Notes in Computer Science, pp. 687 694, 2003. Proc. of SPIE Vol. 6514 651418-8