screw-retained crown using the Laser-Lok Easy Ti temp abutment

Similar documents
cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

screw-retained crown using a PEEK temporary abutment

cement-retained single crowns using cementable abutments

open tray technique using the direct pick-up coping

Multi-unit abutment open tray technique using the direct pick-up coping

verification jig fabrication

OD Secure chairside pick-up using existing denture

closed tray technique using the indirect transfer coping

fabricating a custom impression coping using the closed tray technique

Multi-unit abutment closed tray technique using the indirect transfer coping

closed tray pick-up technique using the snap coping

abutment selection guide

ball abutment overdenture: chairside pick-up using existing denture

surgical and prosthetic options & impression technique overview

introduction to BioHorizons prosthetics

Multi-unit abutment hybrid or fixed-detachable screw-retained restoration

Multi-unit abutment bar overdenture

internal impression quick reference guide

a closer look at Cytoplast High Density PTFE performance predictability efficacy High-Density PTFE (dptfe)

prosthetic technique manual

international biologics product catalog

internal Impression Technique Guide Internal Implant System

Hex-Lock Abutment System. Restorative Manual

for Tapered Internal, Internal, Zimmer Screw-Vent and Tapered Screw-Vent implants Simple Solutions Abutments with Laser-Lok technology

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Legacy Prosthetic Catalog

Restoring Straumann implants. with Locator abutments.

4766 Research Dr. San Antonio, TX insightdentalsystems.com

guided surgery kit catalog & manual

INTRODUCTION. Why Choose Cortex Prosthetics?

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

TeethXpress. immediate load solutions. before TeethXpress. after TeethXpress

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

tapered short surgical system

How something small, can make such a big difference!! Your best choice in overdenture

SS Implant System 2013 PROSTHETIC PROCEDURE

Prosthodontic Procedure

US Implant System 2013 PROSTHETIC PROCEDURE

Product Ordering Information

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

SimpleLine II Surgical / Prosthesis Manual

IOS & The Sirona Connect System Clinician Procedure

FIXED-HYBRID EMERGENCY! Why Redo When You Can Rescue?

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

NobelEsthetics. Introduction page 4. Temporary implant restorations page 6. Solutions for existing teeth page 14. Final implant restorations page 26

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Restorative Manual. April

NobelActive. Quick start page 5. Surgical procedures page 8. Prosthetic procedures page 28. Appendix IV cleaning and. sterilization page 66

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

A shield never to be broken On1 concept

Restorative Manual July 2017

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

IMPRESSION PROCEDURES TRAINING MANUAL

- RESTORATIVE PRODUCT CATALOG

Ankylos. Acuris conometric concept. Manual and product catalog

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

User Manual Complete Prosthetic Kit (CPK)

Bridging the Gap Between Original and Multi-Platform Systems.

guided surgery kit catalog & manual

SwissPlant Prosthetic Catalog. SwissPlant

SuperLine & Implantium Surgical / Prosthesis Manual

Implant Phase Flow Chart

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

NARROW DIAMETER implant

TS Implant System 2013 PROSTHETIC PROCEDURE

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Implant And Abutment Level Impressions

Prosthodontic Procedure

OT EQUATOR CASTABLE Single Attachment for Overdentures

High-end solution STEP-BY-STEP USER GUIDE

NARROW DIAMETER implant

/NobelReplace Ø4.3mm. /NobelReplace Ø3.5mm

A Clinician s Guide to Restoring Screw Retained Full Zirconia Implant Crowns.

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

PROSTHETIC PROCEDURE for TS & GS Implant System

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

cara I-Bridge Manual cara makes life so easy

Multi-Unit Abutment Guide

» For multi-unit restorations -

cara I-Bridge Torque for Prosthetic Screws and overview of Screwdrivers

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

SuperLine & Implantium Surgical / Prosthesis Manual

NobelProcera Product Overview

Instructions for Use DENTAL IMPLANTS

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

RESTORATION OF A FULLY EDENTULOUS PATIENT UTILIZING SIMPLE TECHNIQUES FOR IMPRESSION AND FABRICATION OF A HYBRID BRIDGE

Steps in construction of an interim dental implant-supported hybrid prosthesis:

HEXAGON Implant System

Leading material offering and application range. Straumann CARES CADCAM

A Clinician s Guide to Restoring Conus

For the oral rehabilitation

Transcription:

screw-retained crown using the Laser-Lok Easy Ti temp abutment

temporary restorations screw-retained crown using the Laser-Lok Easy Ti temp abutment Use this technique for the fabrication of long-term single or multi unit, screw-retained, temporary restorations. The abutment has Laser-Lok microchannels for connective tissue attachment and is TiN coated for esthetics. Laser-Lok has been shown to create a biologic seal by establishing a physical, connective tissue attachment to the abutment. Use this technique at the time of implant placement, implant uncovery or when a Laser-Lok healing abutment has been used to establish and maintain the biologic seal. Important: For ideal results, Laser-Lok components should be used throughout the healing, temporization and final abutment phases. When a Laser- Lok component is temporarily removed for impression making or other restorative procedures, keep the removed Laser-Lok component in sterile saline until reinserting into the mouth. component options Laser-Lok Easy Ti temp abutments.050 (1.25mm) hex driver torque wrench Laser-Lok protective sleeve direct coping screws 1 Remove the Laser-Lok healing abutment Remove the Laser-Lok healing abutment using an.050 (1.25mm) hex driver. Make sure the prosthetic platform is free of bone and soft tissue. 2 Seat the Easy Ti temp abutment Seat the Easy Ti temp abutment, engaging the hex of the implant. Hand tighten the abutment screw using an.050 (1.25mm) hex driver. 3 Mark the abutment Evaluate inter-occlusal dimensions, angulation, and tissue contour. Mark the abutment for the required vertical reduction. Important Maintain at least 3mm of abutment height to avoid damaging the abutment screw. Page 1 of 4

temporary restorations screw-retained crown using the Laser-Lok Easy Ti temp abutment 4 Modify the abutment Remove the marked Easy Ti abutment and secure it to the end of the Laser-Lok protective sleeve marked Full Ti using an.050 (1.25mm) hex driver and hand tighten. Modify the abutment for vertical clearance using a carbide bur or a cut-off disk. Do not modify the margin where the Laser-Lok zone is located. Laser-Lok zone Replace the healing abutment immediately to prevent soft tissue collapse over the implant. 5 Seat the modified Easy Ti temp abutment Remove the healing abutment. Verify the implant prosthetic platform is free of bone and soft tissue. Place the modified Easy Ti temp abutment onto the implant using the abutment screw and an.050 (1.25mm) hex driver. Hand tighten. 6 Try in shell crown and create access hole Try in the appropriate poly-carbonate/shell crown and modify as needed. Remove the abutment screw using an.050 (1.25mm) hex driver and replace it with the direct coping screw. Finger tighten the screw using the knurled top or hand tighten using an.050 (1.25mm) hex driver. Create a screw-access hole through the shell crown allowing the direct coping screw to pass through. Important: Gently place an appropriate size non-impregnated retraction cord at the margin of the abutment to minimize the risk of contaminating the Laser-Lok zone with acrylic during the next step of the temporization process. Page 2 of 4

temporary restorations screw-retained crown using the Laser-Lok Easy Ti temp abutment 7 Fill the shell crown Mix acrylic or another material of choice and place inside the shell crown. Position the shell crown over the direct coping screw onto the modified Laser-Lok Easy Ti temp abutment. Undercuts on adjacent teeth should be blocked out prior to this reline procedure. 8 Remove and polish the crown Remove the direct coping screw and the relined shell crown/abutment using an.050 (1.25mm) hex driver. Remove the retraction cord. Place the screw-retained temporary crown onto the Laser-Lok protective sleeve using the abutment screw. Fill in any voids, contour, and polish the crown. Replace the healing abutment immediately to prevent soft tissue collapse over the implant. Important: Laser-Lok abutments must be ultrasonically cleaned after they have been modified in order to remove particulate from the Laser-Lok zone. 9 Deliver the temporary crown Remove the healing abutment. Make sure the implant prosthetic platform is free of bone and soft tissue. Irrigate the internal connection of the implant and dry. Try in the prosthesis to confirm fit and contour. Modify as necessary and polish after making adjustments. Re-seat the crown onto the implant and hand tighten the abutment screw using an.050 (1.25mm) hex diver. Take a radiograph along the long axis of the implant to ensure the abutment is seated completely onto the implant. Important: Laser-Lok abutments must be ultrasonically cleaned after they have been modified in order to remove particulate from the Laser-Lok zone. Page 3 of 4

temporary restorations screw-retained crown using the Laser-Lok Easy Ti temp abutment 10 Check and modify occlusion Check the occlusion and contacts. There should only be light contact in centric occlusion and no contact in lateral excursions. Modify as necessary and polish after making any adjustments. 11 Tighten the abutment screw Tighten the abutment screw to 30Ncm using a calibrated torque wrench and an.050 (1.25mm) hex driver. Tightening the abutment screw to 30 Ncm is not recommended if the temporary is placed at the time of surgery. 12 Fill the screw access channel Place a resilient material of choice (gutta-percha, silicone or temporary filling material) into the screw access channel. This allows for easy access to the abutment screw in the future. Fill the remainder of the channel using a composite resin material of choice. Take an x-ray for temporary prosthesis delivery records. Page 4 of 4

notes

notes

Direct Offices BioHorizons USA 888-246-8338 or 205-967-7880 BioHorizons Canada 866-468-8338 BioHorizons Spain +34 91 713 10 84 BioHorizons UK +44 (0)1344 752560 BioHorizons Germany +49 761-556328-0 BioHorizons Chile +56 (2) 23619519 BioHorizons Italy 800-063-040 Distributors For contact information in our 90 countries, visit www.biohorizons.com BioHorizons, Laser-Lok, MinerOss, AutoTac, Mem-Lok and TeethXpress are registered trademarks of BioHorizons. Unigrip is a trademark of Nobel Biocare AB. Zimmer Dental ScrewVent and Tapered ScrewVent are registered trademarks of Zimmer, Inc. AlloDerm and AlloDerm GBR are registered trademarks of LifeCell Corporation. Grafton DBM is a registered trademark of Medtronic, Inc. Spiralock is a registered trademark of Spiralock Corporation. Pomalux is a registered trademark of Westlake Plastics Co. Locator is a registered trademark of Zest Anchors, Inc. Delrin is a registered trademark of E.I. du Pont de Nemours and Company. Bio-Gide is a registered trademark of Edward Geistlich Sohne AG Fur Chemische Industrie. Not all products shown or described in this literature are available in all countries. As applicable, BioHorizons products are cleared for sale in the European Union under the EU Medical Device Directive 93/42/EEC and the tissues and cells Directive 2004/23/EC. We are proud to be registered to ISO 13485:2003, the international quality management system standard for medical devices, which supports and maintains our product licences with Health Canada and in other markets around the globe. Original language is English. BioHorizons. All Rights Reserved. This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please visit www.biohorizons.com Made in the USA shop online at store.biohorizons.com