MEDPOR. Oculoplastic surgery

Similar documents
MEDPOR. Oral maxillofacial surgery

30+ MEDPOR biomaterial. years of proven clinical history

MEDPOR. Plastic surgery

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

A Legacy of Serving the Surgical Community

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

Cranial idtm. Cranial restoration. id SolutionsTM. Individually designed. Personalized care.

Implant Preparation. Page 1

CMF. Maxillofacial portfolio

Technique Guide. SynPOR HD Ocular Spheres. For augmentation or reconstruction.

MEDPOR Biomaterials CRANIAL/NEUROSURGICAL. Innovative Technology in Reconstructive Surgical Implants

Craniomaxillofacial. Customized Mandible Reconstruction Plate. Patient Specific Design Powered by BluePrint Technology

SMARTLockTM. Hybrid MMFTM

SYNPOR HD FACIAL SHAPE SYSTEM SURGICAL TECHNIQUE. For the augmentation or reconstruction of the craniomaxillofacial skeleton

SynPOR HD Facial Shape System. For the augmentation or reconstruction of the craniomaxillofacial skeleton.

Universal Select. Legacy meets flexibility

Customized Mandible Reconstruction Plate

CRANIAL RECONSTRUCTION SOLUTIONS

Low Profile Neuro Plating System. Surgical Technique

low ProfIle neuro PlaTIng system

TissueMend. Arthroscopic Surgical Technique. Arthroscopic Insertion of a Biologic Rotator Cuff Tissue Augment After Rotator Cuff Repair

MatrixNEURO. The next generation cranial plating system.

HydroSet. Fast-setting HA bone substitute

Flexibility In Action. ACL Instrumentation

TrueSight Personalized Planning & Targeting System. Operative technique

EasyStep. Operative technique

Strength and Predictability. Zimmer Collagen Repair Patch

Craniomaxillofacial. Universal Trocar System

*smith&nephew CONTOUR

DuraMatrix portfolio. Restore with confidence

Leibinger Next Generation Universal Trocar System

MatrixNEURO Cranial Plating System

Direct. DirectInject Stryker CMF. Craniomaxillofacial. Operative Technique

Technique Guide Small Bone Fusion System

Surgical Technique. Clavicle Locking Plate

Universal NeuroTM III. 1.5mm Cranial fixation system

Dentoalveolar Bone Fixation System. Bone fixation sets for the office.

NeuroMend. Collagen Wrap Conduits. Operative Technique

Asnis. Micro Cannulated screw system. Xpress operative technique

Technique Guide. Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Prodecures.

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

AVS ARIA TM Product Overview

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Multi-Guide II Mandibular Distractor

Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Procedures.

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones.

Surgical Solutions USA Regenerative Product Catalog USA

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

RPC. Surgical Solutions USA Regenerative Product Catalog

CableFIX Xpress Carpometacarpal Fixation System. Operative technique

Cranial System. Neuro Plating and Screw System

VersiTomic Flexible Reaming System

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

RECOVERY. P r o t r u s i o

Exeter X3 RimFit Acetabular Cup

Foot & Ankle. Smart Toe II. Intramedullary Implant. Operative Technique. Foot & Ankle

RAPIDSORB RAPID RESORBABLE FIXATION SYSTEM. A new resorbable approach to Alveolar bone augmentation

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

Cytoflex Barrier Membrane Clinical Evaluation

SternaLock Blu PRIMARY CLOSURE SYSTEM

Driving performance, delivering versatility. Spetzler -Malis and SILVERGlide Non-Stick Bipolar Forceps

VBOSS TM System Overview. Vertebral Body Support System

Titanium Wire With Barb and Needle

TraumaOne LORENZ PLATING SYSTEM

The AperFix II System

28 Surgical Technique

3.5 mm LCP Extra-articular Distal Humerus Plate

Single Axis Revision Knee System

VLIFT System Overview. Vertebral Body Replacement System

Orbital Plating System OPS 1.5

DISTRACTION PRODUCT OVERVIEW. For a wide variety of facial applications

Foot & Ankle. EasyClip. Osteosynthesis Compression Staples. Foot & Ankle

Compact Midface. The systematic solution for craniomaxillofacial indications and displacement osteotomies.

Trabecular Metal Acetabular Restrictor and Augment

WINSTA-C. Clavicle Plating System

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

Trabecular Metal Acetabular Restrictor and Augment

AxSOS Locking Plate System

Exeter Contemporary Flanged Cup. Exeter. Providing Solutions

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

RibFix Blu. Thoracic Fixation System

Surgical Technique. Olecranon Locking Plate

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

LactoSorb. Distraction. Resorbable Distraction. Anticipate. Innovate ṬM

PAL Pelvic Alignment Level

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

ADVANCED BONE GRAFT SYSTEM OVERVIEW

Mandible Reconstruction Module Reference ence Guide

Surgical Technique. Calcaneal Locking Plate

Plate/Valve Specifications: Thickness: 0.9mm Width: 13.00mm Length: 16.00mm Surface Area: mm 2

Technique Guide. ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Hoffmann II Compact External Fixation System

ACETABULAR CUP SURGICAL TECHNIQUE

TRABECULAR METAL ACETABULAR RESTRICTOR AND AUGMENT. Surgical Technique

EPF Endoscopic Plantar Fasciotomy. Operative technique

Mako Partial Knee Patellofemoral

Surgical Technique. Proximal Humerus Locking Plate

Transcription:

MEDPOR Oculoplastic surgery

MEDPOR biomaterial MEDPOR has been a trusted name in the industry since 1985, with hundreds of thousands of procedures performed, and hundreds of published clinical reports in reconstructive, cranial, Oculoplastic surgery, and cosmetic applications. Our MEDPOR product line provides you an array of porous polyethylene solutions for your reconstruction and augmentation needs. We understand that biocompatibility characteristics of implants are paramount to help surgeons achieve positive patient outcomes. The omni-directional pore structure of our polyethylene implants may increase implant acceptance by allowing the patient s native tissue to integrate with the implant. In addition to our comprehensive line of stock MEDPOR implants, we offer CT-based patient specific implants, putting the implant design in your hands. 30+ years of proven clinical history

MEDPOR is easy to work with. The material can be trimmed with a blade in the sterile field, carved and feathered intra-operatively for an excellent final fit. No pre-placing of fixation plates. MEDPOR can be easily drilled and fixated and is designed to accept screws and plates without cracking, giving the surgeon more flexibility in fixation options and placement. MEDPOR surgical implants can be cut with a variety of surgical instruments. Implants may require fitting to the defect area at the time of surgery. The implant edges can be delicately shaped and feathered for a smooth transition from the implant to the patient s own bony contour. MEDPOR surgical implants are provided sterile and should not be resterilized. Do not place or carve the implant on surgical drapes, surgical clothing or any other surface that may contaminate the implant with lint and other particulate matter.

Spheres MEDPOR spheres provide surgeons with porous, biocompatible materials for orbital reconstruction following enucleation and evisceration procedures. The interconnecting, omni-directional pore structure of the MEDPOR biomaterial may allow for vascularization and soft tissue ingrowth. Healthy extra-ocular muscles can be sutured directly to the implant or to an overlying tissue wrap. CT# Description Size (mm) diameter 6316 Sphere 14 6326 Sphere 16 6327 Sphere 18 6317 Sphere 20 6322 Sphere 22 SPHERES Smooth Surface Tunnel spheres (SST-EZ) Smooth Surface Tunnel (SST-EZ) spheres have a smooth, porous anterior surface and suture tunnels to allow easy rectus muscle attachment without the use of an implant wrap. The redesigned suture holes and curved tunnels of the new MEDPOR SST-EZ may allow for easier insertion of ophthalmic needles typically used to attach the extra-ocular muscles to the implant. oth suture arms from one muscle are passed through each tunnel. Each muscle end can be drawn to within 3mm of the implant anterior apex or allowed to hang back at the desired attachment location. CT# Description Size (mm) 80008 SST-EZ sphere 16 80010 SST-EZ sphere 18 80012 SST-EZ sphere 20 80014 SST-EZ sphere 22 SST-EZ

Orbital volume sizer set MEDPOR Oculoplastic surgery The orbital volume sizer set makes it easy to evaluate post-enucleation orbital volume to select the appropriate size implant. The set contains five (5) sizes of stainless steel spheres with attached handles that are assembled in a convenient sterilizable tray. CT# Description Size (mm) 9805 Sizer set with tray 14, 16, 18, 20, 22 Ocular conformers Ocular conformers are designed to be used after surgery to prevent closure or adhesions during the healing process. Conformers are small, acrylic-cup shaped devices whose inner surfaces are shaped to approximate the curvature of the orbit. MEDPOR Ocular conformers are supplied sterile in both vented and non-vented styles. CT# Description (mm) (mm) Thickness 9547 Non-vented - small 22 19 4.4 9548 Non-vented - medium 24 21 5.3 9549 Non-vented - large 25 22 5.6 9778 Vented - small 22 19 4.4 9779 Vented - medium 24 21 5.3 9780 Vented - large 25 22 5.6 NON-VENTED VENTED Enophthalmos wedge The MEDPOR enophthalmos wedge mimics the contour of the orbital floor and is designed to provide volume to restore the orbit to its normal shape and size. CT# Description (mm) (mm) Thickness 9541 Regular left 22 31 7.00 9542 Regular right 22 31 7.00 9543 Large left 28 40 7.50 9544 Large right 28 40 7.50

ENDURGen Collagen implant designed for use as a soft tissue patch to reinforce soft tissue where weakness exists and for the surgical repair of damaged or ruptured soft tissue membranes in plastic and reconstructive surgery of the face and head. iomaterial for excellent results Cross-linked - ENDURGen biomaterial is made up of acellular cross-linked porcine dermal collagen with its constituent elastin fibers. 1 Structural architecture - collagen matrix has a structural architecture comparable to human tissue, which may offer a natural scaffold for fibroblast infiltration and vascularization. 1 Tough but flexible - readily conforms to anatomical shapes and may provide surgeons with the flexibility to meet their patient s individualrequirements; may be cut, shaped and sutured. Long-lasting - the enzymatic digestion and cross-linking manufacturing process makes ENDURGen Implants resistant to breakdown and absorption, potentially allowing the surgeon to effect a durable repair or reconstruction for soft tissue contouring and/or reinforcement procedures. 1 Moist - implants are supplied sterile in double wrapped, heat sealed packet and require no hydration prior to use. Uniform - consistent thickness throughout the implant. CT# Thickness (mm) (cm) (cm) 89221 0.50 2 5 89223 1.00 1 4 89224 1.00 2 5 89225 1.00 3 8 ctual size 2cm x 5cm x 0.5mm Lower eyelid spacer CT# Description (mm) (mm) Thickness (mm) 81004 Lower eyelid spacer universal - thin 42 20 0.35

MEDPOR TITN Combines high-density polyethylene and titanium mesh in a single implant for increased flexibility, shape retention, radiographic visualization and strength 2. Configurations MTM Titanium mesh embedded within porous, high-density polyethylene. MT Titanium mesh embedded within a porous polyethylene matrix with a solid, barrier surface on one side, potentially allowing for fibrovascular ingrowth only on the porous side of the implant. T Titanium mesh embedded within solid, non-porous high-density polyethylene. The smooth barrier surface can prevent fibrovascular ingrowth. 3D Orbital floor Implants designed using CT-scan data to approximate the anatomy of the orbital floor & medial wall to enhance the effectiveness and efficiency of reconstruction. MEDPOR coating minimizes sharp edges even if the plates require modification, and the superior, non-porous barrier side helps prevent tissue ingrowth along the aspect of the globe. Catalog # Description 81041 MEDPOR TITN 3D Orbital floor, MT left small 81042 MEDPOR TITN 3D Orbital floor, MT right small 81043 MEDPOR TITN 3D Orbital floor, MT left large 81044 MEDPOR TITN 3D Orbital floor, MT right large 01-01820 Plate holding forcep Plate C D a b Large L/R Small L/R 36mm (1.4 in.) 32mm (1.2 in.) 37mm (1.4 in.) 35mm (1.4 in.) 17mm (0.6 in.) 13mm (0.5 in.) 1.2mm 1.2mm d c

TITN Orbital Floor and Wall (OFW) US Patent 7,655,047 CT# Description (mm) (mm) C (mm) Thickness 81034 MX MTM 42 41 1.0 0.85 81035 MX MT - Left 42 41 1.0 1.0 81036 MX MT - Right 42 41 1.0 1.0 CT# Description (mm) (mm) C (mm) Thickness 81030 MTM 42 41 0.5 0.85 81031 MT - Left 42 41 0.5 1.0 81032 MT - Right 42 41 0.5 1.0 81033 T 42 41 0.5 0.6 TITN implants CT# Description (mm) (mm) Thickness 81020 MTM 50 76 0.85 81021 MTM 38 50 0.85 81022 MTM 38 50 1.50 81023 MTM 50 76 1.50 81024 T 38 50 0.60 81025 T 50 76 0.60 81026 MT 38 50 1.00 81027 MT 50 76 1.00 81028 MT 38 50 1.60 81029 MT 50 76 1.60

TITN fan vailable in two configurations, with or without a RRIER CT# Description (mm) (mm) Thickness 81049 MTM 40 61 0.85 81050 MT 40 61 1.00 Sheets MEDPOR TITN Orbital floor and Wall MEDPOR biomaterial sheets provide the surgeon with options for craniofacial reconstruction and augmentation. CT# Description (mm) (mm) Thickness 83020 Micro thin sheet 38 50 0.25 83022 Micro thin sheet 38 50 0.35 8438 Micro thin sheet 30 50 0.40 83029 Micro thin sheet 38 50 0.45 83030 Micro thin sheet 50 76 0.45 7210 Ultra thin sheet 38 50 0.85 7212 Ultra thin sheet 50 76 0.85 7214 Ultra thin sheet 76 127 0.85 6330 Sheet 38 50 1.50 6331 Sheet 50 76 1.50 8662 Sheet 76 127 1.50 9562 Sheet 38 50 3.00 Thickness 0.25mm 0.35mm 0.40mm 0.45mm 0.85mm 1.50mm 3.00mm

Channel implants Channel implants are designed for repair of significant orbital floor and wall trauma where the addition of one or more rigid fixation plates offers structural support. fter the MEDPOR implant is cut to the desired shape, a rigid fixation plate is inserted in the channel. The plate may extend out both ends of the implant if desired. The plate allows the surgeon to bend and contour the implant to the desired shape. Once the implant shape and proper position is determined, the end of the plate is fixed to the orbital rim. The microplate and miniplate channel implants are 2.3mm thick and have multiple parallel channels. The miniplate and microplate channel implant accepts 1.2mm wide plates and is used when the implant is cantilevered from the orbital rim. Channel implants are available with or without a RRIER surface. CT# Description (mm) (mm) C (mm) 9527 RRIER microplate single channel sheet 38 50 0.85 9531 RRIER miniplate channel sheet 40 52 2.30 9532 RRIER microplate channel sheet 40 52 2.30 RRIER sheets CT# Description (mm) (mm) Thickness 8305 Orbital floor implant 38 50 1.00 9305 Orbital floor implant 38 50 1.60 8312 Rectangle 50 76 1.00 9312 Rectangle 50 76 1.60

Complete and 2/3 orbit shapes MEDPOR Oculoplastic surgery Complete and inferior 2/3 orbit implants are designed to replace non-load bearing, bony structures of the orbital area. Complete and 2/3 orbits are typically carved with a blade or scissors to fit the patient s defect and fixed with sutures, wires or craniofacial screws and plates. CT# Description (mm) (mm) 9567 Inferior 2/3 orbit - left 108 75 9568 Inferior 2/3 orbit - right 108 75 9569 Complete orbit left 93 75 9570 Complete orbit - right 93 75 Inferior 2/3 Orbit Complete Orbit Orbito-Zygomatic (OZ) The MEDPOR Orbito-Zygomatic (OZ) implant is designed for reconstruction of the superior and lateral surfaces of the orbital roof. CT# Description (mm) (mm) C (mm) 81013 Left 33 38 0.80 81014 Right 33 38 0.80 C

Inferior orbital rim The MEDPOR inferior orbital rim implant can provide up to 5mm of anterior projection and is designed to be trimmed to meet the needs of the individual patient. small flange allows it to rest on the most anterior aspect of the orbital floor. This flange allows for positioning of the implant and a possible area for screw fixation to the skeleton. CT# Description (mm) (mm) C (mm) 9429 Inferior orbital rim - left 43 18 3.2 9430 Inferior orbital rim - right 43 18 3.2 Extended orbital rim implants MEDPOR extended orbital rim implants are designed to provide the surgeon with an option for augmenting the inferior rim. CT# Description (mm) (mm) C (mm) 9539 Orbital rim - extended left 47 40 6.3 9540 Orbital rim - extended right 47 40 6.3

Midface contour implant MEDPOR Oculoplastic surgery The MEDPOR midface contour implant is designed to aid in reconstruction or augmentation of the midface. The shell-type design of the implant allows the surgeon to carve portions of the implant most appropriate for each patient. The MEDPOR Midface contour implant is packaged with a sterile silicone template. CT# Description (mm) (mm) C (mm) 83007 Midface contour implant - left 60 40 4 83008 Midface contour implant - right 60 40 4 92-83007 Midface contour implant - left 65 41 4 92-83008 Midface contour implant - right 65 41 4 Midface rim The MEDPOR midface rim is designed to augment areas of bony concavities of the midface, including the inferior orbital rim and malar. CT# Description (mm) (mm) C (mm) 83003 Midface rim - left 47 28 3 83004 Midface rim - right 47 28 3

Orbital rim onlay implants The MEDPOR orbital rim onlay implants are designed to augment the inferior and lateral orbital rims and increase the anterior rim projection. CT# Description (mm) (mm) C (mm) 81001 Orbital rim onlay - left 40 40 8.45 81002 Orbital rim onlay - right 40 40 8.45 Inferior Medial Orbital Rim Implant (IMORI) The MEDPOR Inferior Medial Orbital Rim Implant (IMORI) is designed to wrap over the inferior orbital rim and extend superiorly and inferiorly medial to the inferior orbital nerve. CT# Description (mm) (mm) C (mm) C 87003 Inferior medial orbital rim - left 25 26 2.50 87004 Inferior medial orbital rim - right 25 26 2.50 L R C

Individual designed implants MEDPOR implants are built from patient CT data and offer you the ability to design an implant that fits your patients re-constructive or augmentation needs. Each MEDPOR implant kit contains two (2) identical sterile implants and one (1) sterile host bone model (defect area). The host bone model is provided as a preoperative guide to demonstrate orientation and fit of the customized implant(s). Facial id - Reconstruction and augmentation CT# Description 54440110 MEDPOR patient specific - small 54440210 MEDPOR patient specific - medium 54440310 MEDPOR patient specific - large 54440410 MEDPOR patient specific - XL 54440510 MEDPOR patient specific midface id Solutions TM Individually designed. Personalized care.

Craniomaxillofacial This document is intended solely for the use of healthcare professionals. surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate a Stryker product. surgeon must always refer to the package insert, product label and/or instructions for use, including the instructions for cleaning and sterilization (if applicable), before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: RRIER, T, Facial id, id Solutions, IMORI, MX, MEDPOR, MEDPOR TITN, MT, MTM, OFW, OZ, SST-EZ, Stryker, TITN. ll other trademarks are trademarks of their respective owners or holders. Stryker Craniomaxillofacial Kalamazoo, MI 49002 US t: 269 389 5346 toll free: 800 962 6558 f: 877 648 7114 stryker.com/cmf Devices may not have been licensed in accordance with Canadian Law. ENDURGen is a registered trademark of Tissue Science Laboratories Limited. References: 1: ENDURGen Collegen Implent - Ideal iomaterial for Ideal Results Tissue Science Laboratories Manufacterer s Technical Statement, pp2 and 5, 2005. 2: Holck, D., Foster J., and Dahl T., Custom Shaped Porous Polyethylene-Titanium Mesh Orbital Implants for Internal Orbital Floor/Medial- Wall Fracture Repair CMF-R-91_Rev-1_16059 Copyright 2017 Stryker Printed in the US