simplicity THE SCIENCE OF DESIGN RATIONALE

Similar documents
The science of simplicity

CORAIL HIP SYSTEM DESIGN RATIONALE

Optimizing function Maximizing survivorship Accelerating recovery

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Optimum implant geometry

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Optimum implant geometry

Optimum implant geometry

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

This publication is not intended for distribution in the USA.

Bone Preservation Stem

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

HIP SYSTEM SURGICAL TECHNIQUE

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Surgical Technique. Hip System

Metha Short Hip Stem System

Progeny Hip Stem. Surgical Protocol and Product Specifications

DESIGN RATIONALE AND SURGICAL TECHNIQUE

Integra. Titan Modular Shoulder System, 2.5

MetaFix. Cementless Total Hip Replacement Surgical technique

Featuring. Technology. Product Rationale

Tri-Lock Bone Preservation Stem

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

TOTAL HIP REPLACEMENT:

Overview of Cementless Stems in Total Hip Arthroplasty Review Paper on the Corial Style Stem

Bone Bangalore

CORAIL Upgrade Kit. Surgical Technique

SURGICAL TECHNIQUE. Entrada Hip Stem

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

HELIOS h i p s y s t e m

Bone Conserving Hip Replacement Surgical technique

MetaFix Cementless Total Hip Replacement Product overview

Approach Patients with CONFIDENCE

Hip Fracture Management. Product overview

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Knee Revision. Portfolio

Revision. Hip Stem. Surgical Protocol

TriboFit Hip System. Issue 3 - August 2013 English

CORAIL UPGRADE KIT. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

ACETABULAR CUP SURGICAL TECHNIQUE

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

CORAIL Hip System. Product Rationale and Surgical Technique

CORAIL Hip System. Product Rationale and Surgical Technique

Continuing the Tradition. VerSys Heritage Hip System

This publication is not intended for distribution in the USA. Product rationale and surgical technique

Furlong H-A.C. THR System

Cementless Tapered Femoral Stem Surgical technique

)501( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Cementless Tapered Femoral Stem Surgical technique

MetaFix. Cementless Total Hip Replacement Surgical technique

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

Design Rationale. ECHELON Primary Hip System

AML Hip System. Design Rationale/ Surgical Technique

Approach Patients with Confidence

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

S U R G I C A L T E C H N I Q U E

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

UTF Stem. reduced. Surgical Protocol

AMT ARTICUL/EZE MINI TAPER

PLR. Proximal Loading Revision Hip System

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

TaperFill. Surgical Technique

Specifications guide ECHELON. Hip System

The proven, simple solution. CPT 12/14 Hip System

Surgical Technique. *smith&nephew POLARSTEM Cementless and Cemented Stem System

Understanding Hip Implant Options

Fixed and Variable Geometry Total Shoulder Arthroplasty

Approach Patients with Confidence

Product Rationale. Where Strength and Modularity Connect

Zimmer Segmental System

9800 Metric Blvd. Austin, Texas

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

Arcos Modular Femoral Revision System

ZMR Crossover Instruments. Abbreviated Surgical Technique

Instructions for use for ADLER Cemented Bipolar hemi-arthroplasty Prosthesis

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

FLH /11

Taperloc Complete Hip System. Surgical Technique

Duraloc CONSTRAINED LINER

Hip Resurfacing System

RECLAIM REVISION HIP SYSTEM

The Leader in Orthopaedic Innovation

CONSENSUS ORTHOPEDICS INC.

Avenir Femoral Hip System

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

CPCS. Training Manual. Collarless Polished Cemented Stem

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

Inspiring people, Enriching lives

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Surgical technique MkII instrumentation

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

Transcription:

simplicity THE SCIENCE OF DESIGN RATIONALE

T H E S C I E N C E O F S I M P L I C I T Y The advanced features of the Corail stem, and its bone-preserving surgical technique, have made it a great choice for minimally invasive hip surgery. Twenty years ago, we began a revolution with the use of HA in orthopaedics. Today we face an exciting new era, and we look forward with confidence in sharing continued success with the world's orthopaedic community. ARTRO Group Design Surgeon Team Clinique d'argonay International Visitation Centre Annecy, France US Surgeon Team James Caillouette, MD Charles R. Clark, MD Mark Froimson, MD Jonathan Garino, MD William Lanzer, MD Joel Matta, MD Sam Sydney, MD

Tapered neck geometry and optimized Articul/eze taper increase range of motion Three offset options to restore hip biomechanics Low-profile lateral shoulder design enables easy insertion in reduced incision techniques Available in collared or non-collared options Step geometry converts hoop stresses to compressive loads I've used the Corail since 1998 and with its easy-to-use surgical technique, I choose to use it on many types of patients, including those with osteopenia and in hemiarthroplasty cases for femoral neck fracture treatment. Vertical/horizontal grooves provide rotational and axial stability Proprietary HA coating for initial osteointegration and fixation Jonathan Garino, MD Philadelphia, Pennsylvania

T H E S C I E N C E O F S I M P L I C I T Y roven fixation OPERATIVE STABILITY Corail stepped geometry is oriented to minimize shear forces and maximize compression loading in host cancellous bone RAPID OSTEOINTEGRATION Proprietary HA coating at 155 microns clinically demonstrated rapid trabeculae formation leading to rapid fixation 1 Proximal trapezoid cross section resists axial/torsional stresses and promotes osteointegration for excellent fixation Distal quadrangular cross section provides rotational stability without cortical contact

LONG-TERM FIXATION 1 YEAR POST-OP 16 YEARS POST-OP 98.3 % Survivorship at 10 and 14 years 2 98.9 % Survivorship in 100 consecutive cases at 8 years 3 95.1 % Survivorship in 5,130 cases at 15 years 4 I find the Corail stem design and HA coating provides initial stability for my patients. William Lanzer, MD Seattle, Washington

enhanced b T H E S C I E N C E O F S I M P L I C I T Y NECK ENHANCEMENTS Narrowed anterior-posterior neck dimensions and optimized Articul/eze taper increase range of motion and reduce risk of mechanical impingement Articul/eze 12/14 taper is fully captured by all nonskirted Articul/eze heads, eliminating the creation of a false skirt due to trunnion protrusion Polished neck is designed to generate less wear debris secondary to prosthetic impingement

iomechanics +7 mm +7 mm Stem Axis Stem Axis -5 mm Corail STD Corail High Offset 135 STD 135 High Offset Corail Coxa Vara Corail STD 135 STD 125 Coxa Vara COLLARLESS STEM OPTIONS Standard and high offset collarless stem options enable femoral offset restoration and soft tissue tensioning High offset collarless option adds +7 mm of direct lateralization to restore hip biomechanics in a wider range of patients COLLARED STEM OPTIONS Available in both standard and coxa vara high offset to control subsidence and add rotational stability in patients with osteopenic bone Coxa vara collared neck option offers increased offset and varus neck angles for femoral restoration and proper soft tissue tensioning of varus neck angled patients I use the Corail because of its ease of implantation and long track record. Used with the Pinnacle Acetabular Cup System, it lets me select multiple options in order to optimize hip biomechanics in my patients. Charles R. Clark, MD Iowa City, Iowa

T H E S C I E N C E O F S I M P L I C I T Y one preserving p COMPACTION BROACHING A philosophy of respecting and preserving patient anatomy, biology and physiology are key to the Corail success Compressing and compacting the cancellous bone during the broaching process maintains the medullary canal endosteum, preserving blood supply to the bone and the bone/implant interface Creates an excellent bone/implant contact ratio and high pullout strength for initial and long-term fixation Increases prosthetic torsional stability Preserves the blood supply to promote healing and growth of bone around the implant Forms biological grout that enhances long-term fixation

hilosophy Compaction broaching coupled with Corail creates silent hip replacement. We don't see any adverse, long-term radiographic changes. 18 YEARS POST-OP James Caillouette, MD Newport Beach, California I find the Corail stem and instrumentation facilitate ease of insertion using an anterior approach. Joel Matta, MD Los Angeles, California

T H E S C I E N C E O F S I M P L I C I T Y eritage For initial and long-term fixation, the clinical performance of the full HA-coated Corail Total Hip System is reproducible in all types and sizes of femora. 5 PRE-OP 4 YEARS POST-OP Type A Champagne Flute

PRE-OP 5 YEARS POST-OP PRE-OP 5 YEARS POST-OP Type B Proportional Shape Type C Stovepipe I find it to be reproducible and easy to implant, and use it on many different types of patients. Sam Sydney, MD Baltimore, Maryland After independently reviewing the ARTRO Group Corail data in 1998, I decided to try the Corail stem. I'm pleased with the results and now use it on many types of patients. Mark Froimson, MD Cleveland, Ohio

ESSENTIAL PRODUCT INFORMATION CORAIL AMT HIP IMPORTANT This Essential Product Information sheet does not include all of the information necessary for selection and use of a device. Please see full labeling for all necessary information. SURGICAL TECHNIQUE: THE SCIENCE OF SIMPLICITY INDICATIONS The Corail AMT Hip Prosthesis is intended for use in total hip arthroplasty and is intended for pressfit (uncemented) use. Total hip arthroplasty is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. Total hip replacement is indicated in the following conditions: 1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. Avascular necrosis of the femoral head. 3. Acute traumatic fracture of the femoral head or neck. 4. Failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, or total hip replacement. 5. Certain cases of ankylosis. The non-porous Corail AMT Hip Stem is indicated for cementless use only. CONTRAINDICATIONS The following conditions are contraindications for total or hemi-hip replacement: 1. Active local or systemic infection. 2. Loss of musculature, neuromuscular compromise or vascular deficiency in the affected limb rendering the procedure unjustified. 3. Poor bone quality, such as osteoporosis, where, in the surgeon s opinion, there could be considerable migration of the prosthesis or a significant chance of fracture of the femoral shaft, considerable migration of the prosthesis or a significant chance of fracture of the femoral shaft and/or the lack of adequate bone to support the implant(s). 4. Charcot s or Paget s disease. 5. For hemi-hip arthroplasty, any pathological condition of the acetabulum, such as distorted acetabuli with irregularities, protrusion acetabuli (arthrokatadysis), or migrating acetabuli, that would preclude the use of the natural acetabulum as an appropriate articular surface for the hemi-hip prosthesis. WARNINGS AND PRECAUTIONS HA coated implants must not be implanted with cement Stainless steel 316L/CoCr couplings are forbidden When changing the head on a femoral stem which is still in place, it is essential to use a metal head ADVERSE EVENTS The following are the most frequent adverse events after hip arthroplasty: prosthesis working loose, dislocation, infection, thrombosis, cardiovascular disturbances, and hematoma. STEP 1: Neck Osteotomy STEP 3: Offset Selection & Head Trialing STEP 2: Femoral Canal Preparation STEP 4: Femoral Component Insertion REFERENCES 1. Hardy D, Frayssinet P. Hydroxyapatite-coated femoral arthroplasties: A long-term study through 29 Corail prostheses explanted during a ten-year survey. Surgical Technology International X. 2003. 2. Vidalain JP. Corail Stem Long-Term Results based on the 15-Years ARTRO Group Experience. Fifteen Years of Clinical Experience with Hydroxyapatite Coatings in Joint Arthroplasty, Ed. Springer, 217-224; 2004. 3. Rokkum M, Brandt M, Bye K, Hetland KR, Waage S, Reigstad A. Polyethylene wear, osteolysis and acetabular loosening with an HA coated hip prosthesis. A follow-up of 94 consecutive arthroplasties. J Bone Joint Surg Br. 1999;81(4):582-9. 4. Furnes O, Espehaug B, Lie S, Engesaeter LB, Vollset S, Hallan G, Fenstad AM, Havelin LI. Prospective studies of hip and knee prostheses. The Norwegian Arthroplasty Register. 1987-2004. Scientific exhibition presented at the 72nd Annual Meeting of the American Academy of Orthopaedic Surgeons, February 23-27, 2005, Washington, DC, USA. 5. Chatelet JC, Setiey L. Long-term study of osteolysis around the hydroxyapatite-coated total hip arthroplasty without cement. British Editorial Society of Bone and Joint Surgery. 2004;86-B (supple I):39. For more information about DePuy products, visit our web site at www.jnjgateway.com or www.depuyorthopaedics.com. 2.5M1205 0612-70-501 Printed in USA. 2005 DePuy Orthopaedics, Inc. All rights reserved.