Charging the AccuChek Inform II on the Base Unit. Highlights of New AccuChek Inform II Whole Blood Glucose System

Similar documents
Fraser Health Authority Accu-chek Inform II: Training Script

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014

Point of Care testing refers to all laboratory testing that is done outside of the walls of the clinical laboratory in the proximity of the patient.

Management of Central Venous Access Devices. Blood Glucose Monitoring

CoaguChek Outpatient Clinic: CoaguChek XS - Quick Reference Guide

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

TITLE: Whole Blood Glucose Monitoring Using the Nova StatStrip Meter

Abbott PXP Glucose Meters Resource: Lin Gustafson, MT(ASCP) Point of Care Coordinator, Laboratory

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Point of Care Testing. Bedside Glucose Meter

Current Status: Active PolicyStat ID: Accu-Chek Whole Blood Glucose Testing Policy PURPOSE

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

Precision ceedpro. Online Training for. Glucometer & Capillary Collection

Summary of Significant Changes at this Revision

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Dear HighQ Check System Owner :

SARASOTA MEMORIAL HOSPITAL

University of Virginia Health System AccuChek Inform II Glucose Meters POC C2.21

Title/Description: Point of Care Glucose Testing-Waived Department: Organization Wide Personnel: All Effective Date: November 29, 2016 Revised:

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Items in the package:

Point of Care (POC) Glucose Testing Revised on: December, 2018 Reference: Policy LAB 23-A; Point of Care Nova Stat Strip Glucose Meter

Summary of Significant Changes at this Revision. Items Required. Printed copies are uncontrolled unless there is an allocated Copy Number on page 1

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

THE VALLEY HOSPITAL Ridgewood, New Jersey PATIENT CARE SERVICES (PCS) POLICIES AND PROCEDURES

User manual for healthcare professionals

Urine Dipstick Medical Mobile Unit: Patient Test Procedure

User s Manual Blood Glucose Meter

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

IMPORTANT POINTS TO REMEMBER:

User s Manual Blood Glucose Meter

04 ACCU-CHEK INFORM II GLUCOSE METER

BeneCheck BK6-12M. Plus Multi-Monitoring Meter and Strips

W IMPORTANT INFORMATION FOR PERFORMING A BLOOD GLUCOSE TEST

Tips for Training New Customers

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Accu-Chek Inform II BLOOD GLUCOSE MONITORING SYSTEM. Operator s Manual

Title: Abbott Optium Xceed Glucose Meter Effective date: 16/05/2011. Summary of Significant Changes at this Revision. SOP updated.

Precision Xtra Training

Blood Glucose Monitoring System. User Guide

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

Accu-Chek INFORM II Blood Glucose Determination. Added:

Policies. Policy #: PH1582. Title: Blood Glucose Meter Checks at the patient Bedside Department: PCS-HouseWide. Page 1 of 12.

MDT2. Self-Monitoring Blood Glucose System. Quick Reference Guide

The performance of Microdot Test Strips has been evaluated both in laboratory and in clinical tests.

Current Status: Active PolicyStat ID: Implementation: 02/2012 Last Reviewed: 06/2017 Last Revised: 05/2017 Next Review: 06/2019

Summary of Significant Changes at this Revision. Items Required

Multi User Model. Product Overview

Operator s Manual. Blood Glucose and β-ketone Monitoring System. Abbott Diabetes Care Inc South Loop Road Alameda, CA USA

Performa BLOOD GLUCOSE METER. Operator s Manual

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use

User s Manual. Blood Glucose Meter

User Guide For in vitro Diagnostic Use in Animals Featuring the AlphaTRAK 2 Meter

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

Blood Glucose Monitoring System. Owner s Booklet

5.2 mmol USER GUIDE 5.2. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System 12:00 PM METER BG

CentriVet GK Blood Glucose & Ketone Monitoring System

Blood Glucose & Ketone Monitoring System

BLINDED MODE USERS GUIDE SUPPLEMENT

5.2mmol/L. 5.2 mmol USER GUIDE. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System

i-stat CHEM8 + Cartridge Quick Reference Guide

CoaguChek XS Plus System Whole Blood Protime/INR

Blood Glucose Monitoring System. User s Manual for Single Patient Use Only Blood Glucose Meter

EME. Self-Monitoring Blood Glucose System. Quick Reference Guide

GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

Blood Glucose Meter Owner s Manual

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Protn-Latex. For Determination of Protein in Latex. (Cat. # Latex, Latex) think proteins! think G-Biosciences

Roche CoaguChek XS Plus INR

5.2 mmol USER GUIDE. 5.2 mmol/l. Bolus Reminder Notes. 12:00 PM l 10/13. Uses only Contour Next blood glucose test strips.

PLUS One. Blood Glucose Monitoring System. Owner s Manual

EasyMax Voice III Self-Monitoring Blood Glucose System. Quick Reference Guide

Blood Glucose Measurement. Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

PRIMA. Blood Glucose Monitoring System. Owner s Manual

Blood Glucose Monitoring System. Link the Effects of Food to Glucose Results. Owner s Booklet

VOICE. Blood Glucose Monitoring System. Owner s Manual

Blood Glucose and ß -Ketone Monitoring System. Owner s Manual

Alere INRatio 2 METHOD AND SAMPLE COLLECTION

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

ISO IVD 13485: : :2015

Instructions for Use. Welcome!

Logic. Owner s Guide. Blood Glucose Monitor

METHOD FOR THE MEASUREMENT OF BEDSIDE TROPONIN T (cobas h232)

GM700S USER S MANUAL. Blood Glucose Monitoring System

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

Owner's Booklet. Blood Glucose Monitoring System. Accurate, complete blood glucose monitoring through advanced biosensor technology

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

User Manual second language

Gocap System User s Guide

Blood Glucose Monitoring System

Symbols & Messages Refer to the MyStar Extra Owner s Guide for complete instructions for use.

This fi le may not print or view at 100%. Die lines and color breaks do not print.

Owner s Booklet. Wirelessly sends accurate glucose results to MiniMed Paradigm and Guardian Devices. Blood Glucose Monitoring System

Contents of the Prodigy Pocket. Meter. PRODIGY Owner s Manual PRODIGY Owner s Manual

Transcription:

Accu-Chek Inform II: Training Guide Introduction System Components Charging the AccuChek Inform II on the Base Unit AccuChek Inform II Meter tote Highlights of New AccuChek Inform II Whole Blood Glucose System AccuChek Inform II Competency Requirements @ PHSA Cleaning the Meter Performing Quality Control Hands On Performing a Patient test Hands On View Results in Memory Hands On AccuChek Inform II Normal, Action & Critical Ranges for PHSA Sample Types Test Strip Limitations Questions????? Competency Check List Complete & Return to Trainer Training Time for Hands On is approximately 20-30 minutes Page 1 of 12

New AccuChek Inform II Components Meter must be docked for recharging-and remain in Base Unit when not in use. Note: AccuChek Inform II meters, totes & meters are labelled as a set keep together. Accu-Chek Inform II Meter BarCode Scanner Meter Details Power Button o Turn meter off after use and before returning to base. Touch Screen o Only use the pad of a finger ( No pens or sharp objects) Test Strip Port Laser Bar Code Scanner (care to be taken not to flash in eyes) o Capability - for inputting Operator and Patient ID s, QC and test strip lot # s. o No Patient ID s entered at this time. Infra-red contacts in the Base Unit to upload and download information RF Card Cover (for Wireless upgrade)-/site specific information/ NOT IN USE Back of Meter Meter re-set button (for meter freeze situation, press gently with paper clip a few seconds to reboot) contact Point of Care Technologist first. Obtain loaner meter from POCT laboratory in the interim. Re-Chargeable Battery Pack - perform QC after full discharge prior to a patient test. Charging Contacts (To base unit) Accu-Chek Inform II Base Unit(BU) Return meter to Base Unit (BU) after each use for best practice Provides automatic data transfer and battery charge. Connected to PC or direct network drop with the power outlet Base Unit Lights: Blue, Green & Red lights all indicate charge. Green light indicates connection to a PC or network for data transfer Red light indicates trouble or BU is rebooting after a power down. Rechargeable Battery Pack: If fully discharged, battery requires 6 hours for full charge. Can be Page 2 of 12

ready for use within 20 minutes in an emergency. Requires Quality Check prior to use. Manufacturer recommendation is 1 hour Contact Point of Care Technologist is Red light flashing is persistent. BU light shows: Blue if used for a charge only base unit; Accu-Chek Inform II Tote box Accu-Chek Inform II Test Strips Each Tote Box is labelled & assigned to a Glucose Meter and Base Unit o Storage upright or flat o Contains meter, test strip vial, QC, capillary tubes, Lancets (per PHSA protocol) o Disinfectant 2% Chlorhexidine and 70% Isopropyl Alcohol swabs o Quick Reference guide. o Clean Surface of Tote Box regularly o After each use when taken in to patient room Test Strip Box and Vial: Obtain from C&W stores (supply chain top up on the units) All Lot # s validated by Point of Care Testing (POCT) in the Laboratory One Lot # per year 50 test strips in a vial Green box on vials indicates is a maltose free (no interference) Test Strip CODE, Quality Control values and Bar Code is on each vial. Scan Bar Code on the test strip vial with each use Storage is Room Temperature away from windows or heaters Once opened replace cap immediately Use all strips to the manufacturer s expiry date there is no open vial expiry date. Discard plastic Chip Code in box lab use only. Test Strip: Remove a test strip from the vial avoid handling the test strip at FRONT EDGE Replace vial cap immediately after opening. Print Side up showing arrows in to meter (push strip in to meter till meter beeps) Sample application: Apply to FRONT EDGE of test strip Sample requirement: 0.6 ul wipe first drop of blood; use second drop of blood Page 3 of 12

Result Time: 5 seconds Analytical Measuring Range: 0.6 mmol/l 33.3 mmol/l Hematocrit Range: 10 65% Fill the target window from the FRONT EDGE of the strip (not on top of the strip) Fill the yellow target window completely. An insufficient sample will give an error code. Up to 10 minutes to apply sample (meter time out) No sample re-dose Meter must be kept level during sample application (especially QC testing) to avoid fluid entering test strip port Accu-Chek Performa Controls (Quality Control = QC): Level 1 on vial (LO - on meter) Level 2 on vial (HI - on meter) Target values are on the Test Strip Vial Lot # and QC Target Values entered by Point of Care Testing - Lab. Storage is Room Temperature away from windows or heaters Open Vial Expiry is 3 months obtained from Point of Care Lab as per current practice. Caution: QC material has a blue stain that will mark hands and clothing. Ongoing Operator Competency Minimal Requirements: Operator ongoing competency 1 patient test & 2 sets of Quality Control per Year Clinical areas with minimal patient can use the proficiency testing sample as the patient ; or patient test solution both obtained from Point of Care Testing Laboratory. Operator Lockout - if minimum requirement is not met annually. View ELearning Module at orientation - ACCUCHEK INFORM II Glucose Meter Point of Care Testing (Locations: Children s Hospital, Women s Hospital; Women s Health Centre; Sunny Hill Health Centre; Canuck Place, BC Cancer Agency Vancouver Site). Obtaining the Operator ID Each Operator has a Bar Code with a unique Operator ID # - DO NOT SHARE WITH OTHER STAFF. Bar Codes given to the Clinical Nursing Educator/Leader from Point of Care Technologist. (Quarterly Operator Status reports issued by POCT to the Clinical Nursing Educator/ Leader) Page 4 of 12

Cleaning and Disinfecting the Meter CAVIWIPES @ PHSA this is the manufacturer approved cleaning wipe DO NOT USE OTHER BRAND eg. ACCEL TB wipes are corrosive to the meter touch screen Glucose meters and Base Units are cleaned & disinfected: After each patient use (meter only) - before replacing into the meter tote box or base unit. When visibly soiled Remove the meter from the base unit Uplug Base Unit if it is to be cleaned to eliminate electrical hazard. To Clean: Gently wipe surfaces with Caviwipe to clean or disinfect. Do not allow pooling on the touch screen or contact surfaces. Same cleaning wipe can be used for all parts of meter/base unit. meter has only one opening strip port entry Always allow meter and base unit to thoroughly air dry before putting back into use To Disinfect: If visibly soiled wipe to remove soil then wipe with a 2 nd wipe for disinfection. To Disinfect / Decontaminate allow the surface to remain wet for 3 minutes, wipe dry. HANDS ON - Work on a clean surface. Use paper towel or tissue. Do not place reagents directly on surface. (HAND OUT METERS, REAGENTS, Temporary Operator ID Bar Codes) Performing a Quality Control Test: Remove meter from base unit. Base Units are typically connected to a PC or Network drop unique by location. Take meter with tote to a testing area. 1. Press and release the On/Off button 2. Meter performs a Self Check 3. Power Up screen appears 4. Confirm date and time 5. View battery life symbol in bottom right corner 6. Proceed to the next screen Manually - touch the arrow symbol Automatically - after 5 seconds Page 5 of 12

Entering Operator ID (manual) 1. Touch the symbol to backspace and delete a character entered incorrectly 2. Screen is set to NUMERIC @ PHSA 3. Touch symbol to confirm 4. Once entry is complete, the main menu appears Entering Operator ID (Barcode Scanner): 1. Touch and release symbol in top right corner of screen (black background=scan mode) 2. Hold meter so window of scanner is 4-8 inches above barcode you wish to read. 3. Meter beeps once the barcode has been read successfully and info scanned appears on screen. 4. Scanner turns off after 5 seconds. Perform a Quality Control (ATTENDEES will perform both Level 1 and Level 2 during Hands ON) Quality Control is run at a minimum once every 24 hours QC Lockout is in effect as per current practice. 1. Touch Control Test 2. Touch Level 1 (Lo) or Level 2 (Hi) to select the level for the test desired 3. To select lot number for the lot number of the control vial: Touch the barcode symbol at top right corner of screen Scan the lot number on the control vial - hold meter so scanner is 4-8 inches in front of vial barcode 4. Repeat procedure above to scan test strip vial lot number. Note: Lot numbers for QC or Test Strips cannot be manually entered. 5. Flashing Arrow symbol appears. Insert test strip into test strip port at top of meter. 6. Flashing Drop symbol appears. Meter is ready for QC sample Mix the control vials by gently inverting 5 times Remove cap and wipe vial with tissue Discard first drop and apply 2nd drop to FRONT EDGE of strip. Note: Test strip must ALWAYS be in meter BEFORE application of QC solution Position the meter on a flat surface or downwards DO NOT allow liquid in test strip port. Blue dye in solution can stain clothing Result will appear within 5 seconds. Page 6 of 12

7. Touch RANGE OUT OF RANGE symbol to view the QC range. If Result in range, touch Check Mark to return to Main Menu screen. If result is out of reference range for level, Out of Range symbol will flash. A comment is required when QC is Out of Range or if there is an ERROR CODE. Touch Cloud symbol in lower left corner of screen. Pre-programmed comments appear to select. (Up to 3 comments can be selected) Touch Checkmark in lower right to confirm selection. Touch Check Mark again if satisfied with comment to exit from screen. Note: Once exited from QC result/comment screen, new comment cannot be added later Pre-Programmed Comments for Quality Control Testing available to use in Meters @ PHSA: QC Procedure Error Wrong QC Vial To Repeat QC Test To Remix QC vial Repeated QC Test Open new Strip Vial Patient Test - Puncture Site & Sample Collection Puncture site is clean. Clean site with soap and water if required. Disinfectant is 2% Chlorhexidine & 70% isopropyl alcohol Allow puncture to Air Dry. Refer to skin puncture procedures for appropriate puncture sites and lancets. Use second blood drop for testing Use of microcapillary tube with neonate collections in incubators or difficult patients Page 7 of 12

Performing Patient Test (Attendees simulate a Patient Test with Levels 1-6 Comfort Curve Linearity solutions, no self-testing with blood) Arterial, line samples, or skin puncture may be used. Follow reference guides for sample collection. Neonate or Pediatric Samples may be collected in micro collection pipettes prior to test strip application. It is mandatory to collect Samples from patients in Incubators using the micro collection pipettes. Only the approved micro collection pipette can be used. 1. Touch Patient Test 2. Next Screen displayed will ask for Patient ID. NOT CURRENT PRACTICE AT PHSA Pass through this page. Note: Use of Patient ID is not activated @ PHSA 3. Confirm selection of Patient Test Touch in lower right corner of screen to bypass this screen. Confirm the test strip lot as per in the Quality Control Test procedure. 4. Touch the barcode symbol at top right corner of screen to enter the lot number of the Test Strip Vial. Scan the lot number on the test strip vial hold the meter so scanner is 4-8 inches in front of vial barcode 5. Flashing Arrow symbol appears. Insert test strip into test strip port. Test Strip Port at the top of meter. Note: Test strip is ALWAYS inserted into the meter BEFORE application of patient blood sample!! 6. Flashing Drop symbol appears. (up to 5 minutes to apply sample before meter times out 10 minutes in Neonate setting) Can simulate with a Level 5 or 6 Proficiency sample during training. Meter is ready for Patient sample. Follow reference guides for the capillary puncture. Select puncture site Choose appropriate capillary puncture device Puncture site is clean. Clean site with soap & water if required. Page 8 of 12

Disinfect with 2% chlorhexidine in 70% isopropyl alcohol Perform skin puncture. Remove first drop of blood. (removes any contaminants or residual disinfectant solution which could dilute the glucose value). Apply 2 nd drop to the FRONT EDGE of the test strip. Result appears after 5 seconds Numerical Glucose value will display if within 0.6-33.3 mmol/l @ PHSA there are two different configurations programmed: Configuration 1 Children s Hospital Women s Hospital Neonate ranges Sunny Hill Displayed Canuck Place Configuration 2 BC Cancer Agency all wards & clinics Adult ranges Displayed _ Page 9 of 12

7. Touch Range Field to view the Normal,, Action, or Critical Results Ranges. Touch Range, Out of Normal Range, Out of Critical Range, Out of Reportable Range Fields to view the PHSA Normal, Critical Range, Analytical Measuring Ranges for Neonates, Pediatrics, or Adults. A comment is required when Patient Test is Out of Normal Range or if there is an ERROR CODE. Touch Cloud symbol in lower left corner of screen. Pre-programmed comments appear to select. (Up to 3 comments can be selected) Touch Checkmark in lower right to confirm selection. Touch Check Mark again if satisfied with comment to exit from screen. Note: Once exited from Patient result/comment screen, a new comment cannot be added later Pre-Programmed Comments when reporting a Patient Test available to use in Meters @ PHSA: Procedure Error NEO GLU over 5.5 to Chk To Repeat PT Test Repeated Test Repeat with Lab Draw Doctor Notified To Use 2 nd Drop Open new Test Strips 8. Touch Check Mark if satisfied with patient result to exit from screen. Review a Patient Test or QC Test Result 9. Touch Review Results from Main Menu Screen. Stored test results are displayed in a sequential list. Touch UP or DOWN ARROW to scroll up or down in the list. Results are grouped by date. Touch an entry in the list to display the related details. Page 10 of 12

AccuChek Inform II Test Strip Limitations: Galactose Elevated Galactose can occur in neonates with inherited galactosemia (1 per 40,000 in BC). First glucose value for neonates > 5.5 mmol/l is checked simultaneously with a lab glucose during first 5 days of life. (Collect a lab draw prior to next scheduled feed). Clinical assessment of patient important to identify neonatal galactosemia. Use a Lab Draw to confirm any unexpected high neonate glucose result. Consult with physician. During the treatment of parenterally galactose containing drugs: (eg. Echovist and Levovist) Send to lab, or repeat the test after the half-life of drug. Triglycerides interference if > 20 mmol/l far beyond average values Concentrations above 5.7 mmol/l are considered very high. An extremely low number of people have concentrations of 20 mmol/l or higher. Ascorbic Acid interference if > 0.17 mmol/l ICU patients receiving high dose IV ascorbic acid as support Questions & Inform II Competency Checklist When the Competency Checklist is completed by the operators, please collect. Return to Point of Care Testing Office at the end of the day for record keeping. Note: @ PHSA there is a Presentation with a Quiz to view on the Learning Hub. Part of the certification process. Page 11 of 12

REVISION & APPROVAL LOG Version Revision Type Description of Change Revision Date Technical Approval Medical Approval 1.0 New document 30 Nov 2014 Elvira Kozak Dr. Cathy Halstead 1.1 Minor Document title and number change. Upload to QMS document control 27 Dec 2016 Dr. Benjamin Jung Attention: This document is published on the BCCW SharePoint website Revisions made to this document require an update to the corresponding document published on BCCW SharePoint website Page 12 of 12