Clinical Practice Statement: What Evaluations Are Needed in Emergency Department Patients after a TASER Device Activation?

Similar documents
Metabolic Acidosis Detail

Cardiac, Physiologic, and Real World Effects of Taser Use

Safety and Injury Profile of Conducted Electrical Weapons Used by Law Enforcement Officers Against Criminal Suspects

NON-LETHAL WEAPONS. K. Inaba, MD FRCSC FACS Division of Trauma Surgery & Critical Care LAC+USC Medical Center

Trending PA Interactions with Law Enforcement. Disclaimer/Conflicts. Objectives

Is Cervical spine protection always necessary following penetrating neck injury

CONDUCTED ELECTRICAL WEAPON RESEARCH INDEX- updated may 12, 2014

REPORT 6 OF THE COUNCIL ON SCIENCE AND PUBLIC HEALTH (A-09) Use of Tasers by Law Enforcement Agencies (Reference Committee D) EXECUTIVE SUMMARY

AAEM Clinical Practice Committee Statement Literature Search / Grading Process - Revision Version 3.0 September 2011

Electronic Control Device Research Index

Heston Case. in the. Synopsiss

Echocardiographic Evaluation of a TASER-X26 Application in the Ideal Human Cardiac Axis

BJA Performance Measures

TASER and In-Custody Deaths

Electrical injury : are tasers the new wave?

FORCE SCIENCE INSTITUTE, Ltd.

AFRL-RH-FS-TR Risk Mitigation during Human Electromuscular Incapacitation Research

Literature Review and Recommendations Prehospital Fibrinolytics Administration for Acute Myocardial Infarction

Clinical Practice Committee Statement Protocols (updated 2/22/2018) Henry Kim, MD FAAEM William Meurer, MD FAAEM. Steven Rosenbaum, MD FAAEM

McLean ebasis plus TM

Dr. Steve Ligertwood Dr. Roderick Tukker Dr. David Wilton

Ventricular Fibrillation Detail

Help Wanted: MRO guidance in a THC world. RMAOEM April 6, 2018

Simon A. Mahler MD, MS, FACEP Associate Professor Department of Emergency Medicine Wake Forest School of Medicine

Emergency Department Boarding of Psychiatric Patients in Oregon

INSIGHTS AND BEST PRACTICES FOR EMS AGENCIES

Electroshock weapons: physiologic and pathologic effects - literature review

WORKSHEET for Evidence-Based Review of Science for Veterinary CPCR

FORCE SCIENCE INSTITUTE, Ltd.

Electronic Control Device Research Index

What the s wrong with this person?

Trauma Registry Documentation December 16, 2014

Faculty Disclosures. Objectives. Best Pediatric Emergency Medicine Articles for 2012

Electronic Control Device Research Index

NEW SPINAL PRECAUTION STANDARDS

IMPLEMENTING RECOVERY ORIENTED CLINICAL SERVICES IN OPIOID TREATMENT PROGRAMS PILOT UPDATE. A Clinical Quality Improvement Program

ENROLLMENT : Line of Business Summary

1. Skills commonly performed by the first responder include all of the following, EXCEPT:

Immobilizing the spine New national approach

Chapter 2 Triage. Introduction. The Trauma Team

Episode 66 Backboard and Collar Nightmares from EMU Conference. The Risks Associated with Backboard & Collar

Medical Policy Manual. Topic: Peripheral Subcutaneous Field Stimulation Date of Origin: April Section: Surgery Last Reviewed Date: April 2014

ALCOHOL and CRIME in WYOMING

Using Cancer Registration and MDT Data to Provide Information on Recurrent and Metastatic Breast Cancer

Dynamic Spinal Visualization and Vertebral Motion Analysis

Clinical Guidelines And Primary Care

Chapter 24 Field Statistics Overview

Electric Muscle Stimulation (EMS) as Treatment for Chronic (Wrist) Pain

EMS 202: Emergency Medical Technician Course Schedule

The diagnosis of Chronic Pancreatitis

Autopsy Errors with Electronic Control Devices: A Cardiovascular Perspective

Paul R. Bowlin, M.D. University of Colorado Denver. May 12 th, 2008

Mental Health Policy Group Institute of Mental Health

Conducted Electrical Weapon (CEW) Research Index

MEDICAL POLICY SUBJECT: COGNITIVE REHABILITATION. POLICY NUMBER: CATEGORY: Therapy/Rehabilitation

Winter Holiday Suicide Myth Continues to be Reinforced in Press Annenberg Public Policy Center Study Finds

Key statistics from the National Cardiac Arrest Audit: Paediatric arrests April 2012 to March 2017

Peripheral Subcutaneous Field Stimulation

Trauma Overview. Chapter 22

Monitoring Protocol for Clozapine-induced Myocarditis. Copyright 2017, CAMH

Medical Policy. MP Dynamic Spinal Visualization and Vertebral Motion Analysis

Reducing Readmissions and Improving Outcomes at OhioHealth Mansfield Hospital:

Conducted-Energy Device (Taser) Usage in Subjects With Mental Illness

The Influence of Agency Policies on Conducted Energy Device Use and Police Use of Lethal Force

PROPOSAL FOR MULTI-INSTITUTIONAL IMPLEMENTATION OF THE BRAIN INJURY GUIDELINES

ETMC-EMS PARAMEDIC COURSESCHEDULE Oct 25, 2017 to Aug 16, 2018 Varied Day Shift Class DSHS Course #

ITLS Pediatric Provider Course Basic Pre-Test

Corporate Medical Policy Electrocardiographic Body Surface Mapping

Suicide Risk Screening, Assessment and Management

Quick Literature Searches

Cancer. Description. Section: Surgery Effective Date: October 15, 2016 Subsection: Original Policy Date: September 9, 2011 Subject:

Daniel A. Beals MD, FACS, FAAP Pediatric Surgery and Urology Community Medical Center Associate Professor of Surgery and Pediatrics University of

Suicide Prevention through COA s Standards. July 19, 2016

Excited Delirium and CEDs (more Miami mayhem )

Data Visualization - Basics

Pre-hospital Spinal Motion Restriction Standard update. Presented by: Dr. Tatiana Jevremovic CCFP (EM)(SEM), Dip.

C1: Medical Standards for Safety Critical Workers with Cardiovascular Disorders

Sudden Cardiac Arrest and Death Associated with Application of Shocks. from a TASER Electronic Control Device

Medical Affairs Policy

AMBULANCE TRANSPORT PATTERNS FOR ND PEDIATRIC PATIENTS WITH HEAD TRAUMA

Sentinel Stroke National Audit Programme (SSNAP)

EMS Adult Protocols Protocol Title:

3/14/2014 USED TO BE SIMPLE.. TO IMMOBILIZE OR NOT TO IMMOBILIZE.THAT IS THE QUESTION THE PROBLEM OLD THINKING

Region of Waterloo Public Health and Emergency Services Infectious Diseases, Dental, and Sexual Health

Pedicle Subtraction Osteotomy. Case JB. Antonio Castellvi 5/19/2017

High Voltage Safety. Dangers of Electricity. W. Maes. Department of Marine Engineering Antwerp Maritime Academy HV, 2015

Citation Characteristics of Research Published in Emergency Medicine Versus Other Scientific Journals

An Approach to the Patient with Syncope. Guy Amit MD, MPH Soroka University Medical Center Beer-Sheva

TASER X26 Discharges in Swine Produce Potentially Fatal Ventricular Arrhythmias

Telehealth Data for Syndromic Surveillance

Bioimpedance Devices for Detection and Management of Lymphedema

Pet owners are often very anxious about veterinary procedures that involve anesthesia. This handout attempts to alleviate some of these concerns.

Biofeedback as a Treatment of Headache

VIRGINIA S OPIOID & HEROIN OVERDOSE EPIDEMIC

The Interpreting Marketplace

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

This document was created on 07 January 2005 and has been printed from

Critical Appraisal of a Diagnostic Paper (Diagnosis of Lumbar Spinal Stenosis)

Prison-Based Therapeutic Community Treatment: The California Experience

Publications from the UKROC Programme

Transcription:

linical Practice Statement: What Evaluations Are Needed in Emergency Department Patients after a TASER Device Activation? (7/12/10) 2. Literature Search A literature search of the National Library of Medicine s MEDLINE database s PubMed system was performed and limited to studies published from January 1988 to January 20, 2010 written in the English language. Keywords used in search: TASER, conductive energy device(s), electronic weapon(s), conductive energy weapon(s), non-lethal weapon(s), conducted energy device(s), conducted energy weapon(s), conductive electronic device(s), electronic control device(s) The findings of this search are noted in the column # ALL references in table 1. ombining these references resulted in 140 unique articles on EWs. From the original 140 articles, the reference sections were reviewed, and no further novel articles were identified. Studies included for final review were limited to randomized controlled trials, clinical trials, prospective and retrospective cohort studies and meta-analyses. ase reports, case series, and general review articles were not included for the selection criteria for formal rigorous review. The references yielded by the various search parameters are included in the column labeled final review in table 1. The list of the titles of the 140 articles was assessed independently by two physicians, and refined using the selection criteria to a combined total of 20 articles deemed appropriate for review based on their suspected relevance to the clinical question. These 20 articles include: randomized controlled trials (2), prospective controlled trials (2), prospective cohort studies (13), and retrospective cohort studies (3). Table 1: All English language papers found with the following search parameters: # ALL # final review Search Parameter references conductive electronic 0 devices 145 TASER 137 15 conductive energy devices 113 4 conductive electronic 0 device 112 conductive energy device 87 4 electronic weapon 70 8 electronic weapons 54 8 conducted energy 6 weapons 32 non-lethal weapons 30 0

non-lethal weapon 22 0 electronic control devices 12 0 electronic control device 11 0 conducted energy weapon 4 1 conductive energy weapon 3 3 conductive energy weapons 3 conducted energy device 0 0 conducted energy devices 0 0 3 3. Final Evidence Database Grade of Evidence Review For each of the 20 articles subjected to detailed review, the evidence was assigned a grade using reference focus, design and methodology. Grade A Grade B Grade Grade D Randomized clinical trials or meta-analyses (multiple clinical trials) or randomized clinical trials (smaller trials),directly addressing the review issue Randomized clinical trials or meta-analyses (multiple clinical trials) or randomized clinical trials (smaller trials), indirectly addressing the review issue Prospective, controlled, non-randomized, cohort studies Retrospective, non-randomized, cohort or case-control studies 4. Final Evidence Database Quality Ranking Each of the 20 articles subjected to detailed review was critically assessed with regards to design and methodology. This includes Design onsideration (focus, model structure, presence of controls, etc.) and Methodology onsideration (actual methodology utilized) Ranking Design onsideration Present Methodology onsideration Present Both onsiderations Present Outstanding Appropriate Appropriate Yes, both present Appropriate Appropriate No, either present Adequate Adequate with Possible Adequate No, either present Bias Poor Limited or Biased Limited No, either present Unsatisfactory Questionable / None Questionable / None No, either present

List # Article Information Grade Quality Design, size 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Bozeman WP: Immediate cardiovascular effects of the Taser X26 conducted electrical weapon. Emerg Med J. 2009 Bozeman WP: Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects. Ann Emerg Med. 2009 Dawes DM: Echocardiographic evaluation of TASER X26 probe deployment into the chests of human volunteers. Am J Emerg Med. 2010. Dawes DM: Electrical haracteristics of an Electronic ontrol Device Under a Physiologic Load: A Brief Report. Pacing lin Electrophysiol. 2009 Dawes DM: 15-Second conducted electrical weapon exposure does not cause core temperature elevation in nonenvironmentally stressed resting adults. Forensic Sci Int. 2008 Dawes D, Ho J, Miner J. The neuroendocrine effects of the TASER X26: a brief report. Forensic Sci Int. 2009 Eastman AL, et al onductive electrical devices: a prospective, population-based study of the medical safety of law enforcement use. J Trauma. 2008 Jun;64(6):1567-72. Ho JD: Prolonged TASER use on exhausted humans does not worsen markers of acidosis. Am J Emerg Med. 2009 Ho JD: Lactate and ph evaluation in exhausted humans with prolonged TASER X26 exposure or continued exertion. Forensic Sci Int. 2009 Ho JD: Absence of electrocardiographic change after prolonged application of a conducted electrical weapon in physically exhausted adults. J Emerg Med. 2009 Ho JD: Echocardiographic evaluation of a TASER-X26 application in the ideal human cardiac axis. Acad Emerg Med. 2008 Ho JD, Dawes DM, Bultman LL, et al Respiratory Effect of Prolonged Electrical Weapon Application on Human Volunteers. Acad Emerg Med.2007; 14:197 201 Ho JD: ardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006 Levine SD: ardiac monitoring of human subjects exposed to the taser. J Emerg Med. 2007 D B D B Adequate Outstandin g Outstandin g Prospective ohort (n = 28) Retrospective ohort (Field use) (n = 1201) Prospective ohort (n = 10) Prospective ohort (n = 9) Prospective ontrolled Trial (n = 32) Prospective Randomized ontrolled Trial (n = 52) Retrospective ohort (Field use) (n = 426) Prospective ohort (n = 38) Prospective Randomized ontrolled Trial (n = 40) Prospective ohort (n = 25) Prospective ohort (n = 34) Prospective ohort (n = 52) Prospective ohort (n = 66) Prospective ohort (n = 105)

15 16 17 Sloane M: Serum troponin I measurement of subjects exposed to the Taser X-26. J Emerg Med. 2008 Strote J, et al onducted Electrical Weapon Use by Law Enforcement: An Evaluation of Safety and Injury. J Trauma. 2009 Dec 22. [Epub ahead of print] VanMeenen KM, herniack, NS, Bergen, MT, et al. ardiovascular Evaluation of Electronic ontrol Device Exposure in Law Enforcement Trainees: A Multisite Study. JOEM 2010 [Epub ahead of print] 18 Vilke GM: Physiologic effects of the TASER after exercise. Acad Emerg Med. 2009 Vilke GM: Twelve-lead electrocardiogram monitoring of subjects before and after 19 voluntary exposure to the Taser X26. Am J Emerg Med. 2008 Vilke GM: Physiological effects of a 20 conducted electrical weapon on human subjects. Ann Emerg Med. 2007 D Adequate Outstandin g Outstandin g Prospective ohort (n = 66) Retrospective ohort (Field use) (n = 1101) Prospective ohort (n = 118) Prospective ontrolled Trial (n = 25) Prospective ohort (n = 32) Prospective ohort (n = 32) 5. Assign the Reference Support of the Question Independent review of the articles as well as discussion and joint review by the authors was undertaken to answer our clinical question. The references were sorted into 3 categories: supportive, neutral, and opposed. There were no neutral or opposed references. A table was constructed to assign the supportive references to the appropriate location using both the Grade of Evidence and the Quality of Evidence. Supportive Evidence (Article # referenced) Quality / Grade A B D E F Outstanding 12, 13, 18, 20 Adequate Poor 6, 9 1, 3, 4, 5, 8, 10,11, 14, 15, 17, 19 2 7, 16

Unsatisfactory 6. Recommendations Level of riteria for Level of Mandatory Evidence Recommendation Recommendation lass A recommended with outstanding evidence Acceptable Safe Useful Established / definitive Level A / B grade Outstanding quality Robust All positive lass B acceptable & appropriate with good evidence Acceptable Safe Useful Not yet definitive Level A / B grade lacking Adequate to quality Most evidence positive No evidence of harm lass B 1 Standard approach Higher grades of evidence onsistently positive lass B 2 Optional or alternative approach Lower grades of evidence Generally, but not lass not acceptable or not appropriate lass Indeterminate Unknown Unacceptable Unsafe Not useful Minimal to no evidence consistently, positive No positive evidence Evidence of harm Minimal to no evidence Background and goals: EWs are commonly used by police as an intermediate force option. ivilian models of EWs are also available. Patients may be brought for medical evaluation after EW exposure. The primary goal in conducting this literature search was to identify whether routine monitoring, EKG, with or without laboratory tests are necessary for a patient who presents after receiving an electrical discharge from a EW. Our evaluation considered both techniques in which a EW can be used. They are the drive or touch stun mode, and the probe mode. In the drive stun mode, the tip of the device is placed into contact with the subject and locally conducts energy across the two probes that are present on the tip of the device. This mode typically causes local painful stimuli. The other technique is the probe mode, which uses two sharp metal darts that are shot from a distance into the subject or the subject s clothing, causing energy to arc a greater distance across the two probes. If there is enough of a probe spread, generalized muscle contraction, sometimes termed neuromuscular incapacitation, is produced. This may result in the subject falling if he or she is in a standing position. There are case reports of injuries sustained directly from the darts such as ocular, skull or genital penetration. Other case reports of spinal compression fractures presumably from intense muscle contractions of the back musculature in

subjects with osteopenia have been documented.(rehman 2007, Sloane 2008, Winslow 2007, Ng 2005) Recommendation: ardiac monitoring and EKG screening after EW use The current human literature has not found evidence of immediate or delayed cardiac ischemia or dysrhythmias after EW exposures of up to 15 seconds. Therefore, the medical literature does not support routine performance of EKGs prolonged ED observation or hospitalization for ongoing cardiac monitoring after EW exposure in an otherwise asymptomatic awake and alert patient with a short duration (< 15 second)of EW exposure. Studies have looked for dysrhythmias during and immediately after EW use (Bozeman, 2009, Ho 2006, Ho 2007, Ho 2009, Levine, Vilke 2007, Vilke 2008). There have been no reports of ectopy, dysrhythmia, QT prolongation, interval changes or other EKG changes immediately following EW use. Additionally, studies have looked at delayed monitoring findings and there have been no changes in EKGs sixty minutes or longer post EW use (Ho 2006, Vilke 2007, VanMeenen 2010). Studies have also looked at serial troponin levels as a marker of cardiac injury or ischemia. A number of studies have looked at troponin levels at six hours post EW activation, and all levels except one have been normal (Ho 2006, Ho 2007, Sloane, Vilke 2007). The one study that showed elevated troponin, (Ho 2006), was on a healthy young male subject who received a five second TASER activation. The troponin I values all were <0.3 ng/ml, except a single value of 0.6 ng/ml at the 24 hour draw, which was previously normal at the 16 hour draw as well as the subsequent 32 hour draw. The subject was evaluated at the hospital by a cardiologist and showed no evidence of MI or cardiac disability. Echocardiograms during EW use have also shown no abnormalities during activation that suggest no cardiac electrical capture or structural cardiac damage.(dawes 2010, Ho 2008). Level of recommendation: lass A Recommendation: Laboratory testing after EW use The current human literature has not found evidence of dangerous laboratory abnormalities or physiologic changes after EW exposures of up to 15 seconds. Therefore the medical literature does not support routine performance of laboratory studies, prolonged ED observation or hospitalization for ongoing laboratory monitoring after a short duration of EW exposure(<15 seconds) in an otherwise asymptomatic awake and alert patient. Studies have not shown any clinically significant changes in electrolyte levels or renal function in subjects with up to 15 second EW activations (Ho 2006, Ho 2009, Vilke 2007, Vilke 2009). There have been mild, but clinically insignificant elevations in lactate levels with EW activations. However, these have been demonstrated to be of a

smaller magnitude relative to other forms of exertion with a similar duration (Ho 2006, Ho 2007, Ho 2009, Ho 2009, Vilke 2007, Vilke 2009). Acid base status has been evaluated and has not shown any significant ph shifts for a 5 second EW activation (Ho 2006, Vilke 2007, Vilke 2009). Similar findings with mild transient ph shifts were noted in EW use for longer durations of application up to 15 seconds (Ho 2009). Level of recommendation: lass A Recommendation: Evaluation after use of EW in drive stun or touch stun mode For patients who have undergone drive stun or touch stun EW exposure, medical screening should focus on local skin effects at the exposure site, which may include local skin irritation or minor contact burns. This recommendation is based on a literature review in which thousands of volunteers and individuals in police custody have had drive stun EWs used with no untoward effects beyond local skin effects. As above, routine EKG, cardiac monitoring, laboratory testing, or other forms of evaluation specific to the electrical component of short duration EW use are generally unnecessary. Level of recommendation: lass B Recommendation: Evaluation after use of EW in probe mode For patients who have undergone probe mode EW exposure, medical screening should focus on probe penetration sites, potential injuries due to muscle contractions, and potential trauma due to falls. EW probes may strike the eyes, and /or penetrate skin and nearby superficial structures such as vessels, nerves, and bones. Muscle contractions due to the EW may produce spinal compression fractures and other soft tissue injuries. Falls may occur from loss of muscular control and protective reflexes, resulting in blunt trauma. Literature review indicates that significant injuries due to this mechanism are rare, occurring in less than 0.5% of real world deployment in subjects (Bozeman 2009, Strote 2009). As above, routine EKG, cardiac monitoring, laboratory testing, or other forms of evaluation specific to the electrical component of short duration EW use are generally unnecessary. Level of recommendation: lass B 7. List all conflicts of interest: There were no conflicts of interest declared by any committee members.

8. Discussion As noted above, the literature review for this clinical guideline focused on studies that involved rigorous methodologies to evaluate the physiologic effects of EWs in humans. We did not include specific case reports or case series which in and of themselves cannot support any causal connection between EWs and physiologic changes. We also did not include animal studies which are often more limited in scope and have questionable applicability to clinical human findings. Recommendations in this review are limited to EW exposure durations of 15 seconds or less. This reflects the exposure durations commonly used in the existing human literature and will apply to the large majority (>90%) of subjects against whom EWs are used by police officers. While several reports have included exposure durations of 20 to 45 seconds and have not demonstrated concerning cardiac or physiologic effects, collectively this small body of literature is inadequate to support guidelines on medical screening after longer duration exposures. Therefore, until confirmatory studies of adequate power are available, clinicians should use their own judgment regarding the need for screening tests in this population. It is important to point out that these recommendations focus solely on the issue of EWs and their physiologic effects on humans. linical evaluation and testing may very well be warranted when evaluating patients after EW application not because of the EW exposure, but as a result of the patient s underlying condition such as alcohol or drug intoxication, altered mental status, physical exhaustion, excited delirium, or psychiatric conditions which precipitated the application of the EW in the first place. References Bozeman WP, Barnes DG Jr, Winslow JE 3rd, Johnson J 3rd, Phillips H, Alson R. Immediate cardiovascular effects of the Taser X26 conducted electrical weapon. Emerg Med J. 2009 Aug;26(8):567-70. Bozeman WP, Hauda WE 2nd, Heck JJ, Graham DD Jr, Martin BP, Winslow JE. Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects. Ann Emerg Med. 2009 Apr;53(4):480-9. Epub 2009 Jan 21. Dawes DM, Ho JD, Reardon RF, Miner JR. Echocardiographic evaluation of TASER X26 probe deployment into the chests of human volunteers. Am J Emerg Med. 2010 Jan;28(1):49-55. Dawes DM, Ho JD, Kroll MW, Miner JR. Electrical haracteristics of an Electronic ontrol Device Under a Physiologic Load: A Brief Report. Pacing lin Electrophysiol. 2009 Dec 10. Dawes DM, Ho JD, Johnson MA, Lundin E, Janchar TA, Miner JR. 15-Second conducted electrical weapon exposure does not cause core temperature elevation in non-environmentally stressed resting adults. Forensic Sci Int. 2008 Apr 7;176(2-3):253-7. Epub 2007 Nov 5. Dawes D, Ho J, Miner J. The neuroendocrine effects of the TASER X26: a brief report. Forensic Sci Int. 2009 Jan 10;183(1-3):14-9. Epub 2008 Nov 18.

Ho JD, Dawes DM, Bultman LL, Moscati RM, Janchar TA, Miner JR. Prolonged TASER use on exhausted humans does not worsen markers of acidosis. Am J Emerg Med. 2009 May;27(4):413-8. Ho JD, Dawes DM, ole JB, Hottinger J, Overton KG, Miner JR. Lactate and ph evaluation in exhausted humans with prolonged TASER X26 exposure or continued exertion. Forensic Sci Int. 2009 Sep 10;190(1-3):80-6. Epub 2009 Jun 17.. Ho JD, Dawes DM, Heegaard WG, alkins HG, Moscati RM, Miner JR. Absence of electrocardiographic change after prolonged application of a conducted electrical weapon in physically exhausted adults. J Emerg Med. 2009 May 12. Ho JD, Dawes DM, Reardon RF, Lapine AL, Dolan BJ, Lundin EJ, Miner JR. Echocardiographic evaluation of a TASER-X26 application in the ideal human cardiac axis. Acad Emerg Med. 2008 Sep;15(9):838-44. Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegaard WG. ardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006 Jun;13(6):589-95. Epub 2006 Mar 21. Levine SD, Sloane M, han T, Dunford JV, Vilke GM. ardiac monitoring of human subjects exposed to the taser. J Emerg Med. 2007 Aug;33(2):113-7. Epub 2007 Jun 13. Sloane M, han T, Levine SD, Dunford JV, Neuman T, Vilke GM. Serum troponin I measurement of subjects exposed to the Taser X-26. J Emerg Med. 2008 Jul;35(1):29-32. Epub 2008 Mar 4 VanMeenen KM, herniack, NS, Bergen, MT, et al. ardiovascular Evaluation of Electronic ontrol Device Exposure in Law Enforcement Trainees: A Multisite Study. JOEM 2010 [Epub ahead of print] Vilke GM, Sloane M, Suffecool A, Kolkhorst FW, Neuman TS, astillo EM, han T. Physiologic effects of the TASER after exercise. Acad Emerg Med. 2009 Aug;16(8):704-10. Vilke GM, Sloane, Levine S, Neuman T, astillo E, han T. Twelve-lead electrocardiogram monitoring of subjects before and after voluntary exposure to the Taser X26. Am J Emerg Med. 2008 Jan;26(1):1-4. Vilke GM, Sloane M, Bouton KD, Kolkhorst FW, Levine SD, Neuman TS, astillo EM, han T. Physiological effects of a conducted electrical weapon on human subjects. Ann Emerg Med. 2007 Nov;50(5):569-75. Epub 2007 Aug 24. Rehman TU, Yonas H. ase Report: Intracranial penetration of a TASER dart. Am J Emerg Med 2007;25: 733. Sloane M, han T, Vilke GM. Thoracic Spine ompression Fracture after TASER Activation. J Emerg Med. 2008:34(3):283-5.

Winslow JE, Bozeman WP, Fortner M, Alson RL. Thoracic compression fractures as a result of shock from a conducted energy weapon: a case report. Ann Emerg Med. 2007;50:584-6 Ng W, hehade M. Taser penetrating ocular injury. Am J Ophthalmol. 2005 Apr;139(4):713-5.