SOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only

Similar documents
The World s fastest OCT. As simple as pressing. the start button

PRIMUS 200 from ZEISS The essential OCT

Visualize. Analyze. Personalize. OCT + OCTA. with

Visualize. Analyze. Personalize. OCT + OCTA

PRIMUS 200 from ZEISS The essential OCT

3/16/2018. Ultrasound Biomicroscopy in Glaucoma By Ahmed Salah Abdel Rehim. Prof. of Ophthalmology Al-Azhar University

Mark Dunbar: Disclosure

Cirrus TM HD-OCT. Details define your decisions

Cirrus TM HD-OCT. Details defi ne your decisions

HOCT-1I 1F All-in-One Optical Coherence Tomography with Fundus

Introducing ANGIOVUE ESSENTIAL. Built on the Avanti Widefield OCT Platform. OCT Angiography for Primary Eye Care

3/23/2016. Diagnostic Services Taylor Pannell CRA, OCT-C. Services Available. Important info for the Tech to know. Visual Fields

DRI OCT Triton Series A Multimodal Swept Source OCT

Histology of the Eye

THE EYE: RETINA AND GLOBE

Advances in OCT Murray Fingeret, OD

XUE HUI Department of Histology& Embryology, Basic Medicine College of Jilin University

PLEX Elite 9000 from ZEISS Swept-Source OCT

Experience Spectacular Retinal Imaging with the new NIDEK F-10 Digital Ophthalmoscope

Structural examina.on: Imaging

_ Assessment of the anterior chamber. Review of anatomy of the angle

OCT Image Analysis System for Grading and Diagnosis of Retinal Diseases and its Integration in i-hospital

Unit VIII Problem 8 Anatomy: Orbit and Eyeball

5/18/2014. Fundamentals of Gonioscopy Workshop Aaron McNulty, OD, FAAO Walt Whitley, OD, MBA, FAAO

EasyScan: Smart Retinal Imaging

Medical School Histology Basics. VIBS 289 lab. Eye

Cornea/Anterior Segment OCT. User Experience

Evolving glaucoma management True diagnostic integration for the preservation of vision

Vision I. Steven McLoon Department of Neuroscience University of Minnesota

Simply the best OCT & OCTA image quality.

Moving forward with a different perspective

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Corporate Medical Policy

A LITTLE ANATOMY. three layers of eye: 1. outer: corneosclera. 2. middle - uvea. anterior - iris,ciliary body. posterior - choroid

Glaucoma. Cornea. Iris

4/22/16. Eye. External Anatomy of Eye. Accessory Structures. Bio 40B Dr. Kandula

2/26/2017. Sameh Galal. M.D, FRCS Glasgow. Lecturer of Ophthalmology Research Institute of Ophthalmology

The Measure of Confidence

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

The Orbit. The Orbit OCULAR ANATOMY AND DISSECTION 9/25/2014. The eye is a 23 mm organ...how difficult can this be? Openings in the orbit

WORKSHOP B Ophthalmic Imaging: All Hands on Tech! COPE Course PS

Course # Getting to Know Your OCT

Ocular Anatomy for the Paraoptometric

Overview. Macular OCT Artifact Study

The Sense Organs 10/13/2016. The Human Eye. 1. Sclera 2. Choroid 3. Retina. The eye is made up of three layers:

THE CHRONIC GLAUCOMAS

Optical Coherence Tomography: Pearls for the Anterior Segment Surgeon Basic Science Michael Stewart, M.D.

Swept-Source OCT Angiography: SS OCT Angio TM

Technicians & Nurses Program

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Diagnosis and Therapy in Ophthalmology Hand-held optical coherence tomography imaging in children with anterior segment dysgenesis

Routine OCT and UBM of the anterior segment

OCT Interpretation in Retinal Disease

Wallace L.M. Alward, M.D. Frederick C. Blodi Chair Department of Ophthalmology

THE CHRONIC GLAUCOMAS

UNDERSTAND MORE ABOUT UVEITIS UVEITIS

Learn Connect Succeed. JCAHPO Regional Meetings 2016

Glaucoma Evaluation. OCT Pearls for Glaucoma. OCT: Retinal Nerve Fiber Layer. Financial Disclosures. OCT: Macula. Case Example

he Role of UBM and Anterior Segment OCT in Anterior Segment Imaging

Fundus Autofluorescence. Jonathan A. Micieli, MD Valérie Biousse, MD

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Continuing Femtosecond Laser Innovation

02/03/2014. Average Length: 23mm (Infant ~16mm) Approximately the size of a quarter Volume: ~5mL

Optical Coherence Tomography Imaging for Glaucoma Today and Tomorrow. Christopher Kai-Shun Leung

New Technologies in Glaucoma Management: From ERG to OCT

Management of Angle Closure Glaucoma Hospital Authority Convention 18 May 2015

Gonioscopy and Slit Lamp Exam for the Glaucoma Suspect. Disclosure GONIOSCOPY: Gonioscopy Why?? What should I look for? GONIOSCOPY

Written by Administrator Wednesday, 13 January :27 - Last Updated Thursday, 21 January :34

OCT in the Diagnosis and Follow-up of Glaucoma

Optical Coherence Tomography (OCT)

Systems for Anterior Chamber Angle Evaluation 長庚紀念醫院青光眼科吳秀琛

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

Widefield Retinal Imaging with Auto Fluorescence Technology in the Optometric Practice

SOUTH-EAST EUROPEAN JOURNAL of OPHTHALMOLOGY 2015; 1 (1) 34 40

Corporate Medical Policy

Anterior segment imaging

OCT Angiography in Primary Eye Care

The Special Senses: Part A

Interpretation of corneal tomography

Distinction layer by layer. HRT II Rostock Cornea Module

What is the Value of Swept Source oct Technology in Biometry? Experts discussed the IOLMaster 700 at the ESCRS ebook. Content provided by:

Yasser R. Serag, MD Tamer Wasfi, MD El- Saied El-Dessoukey, MD Magdi S. Moussa, MD Anselm Kampik, MD

Around The Globe in 60 Minutes

The ideal tool for early detection and monitoring of AMD.

SAFE, PERMANENT EYE-COLOR CHANGE

Glaucoma Diagnosis. Definition of Glaucoma. Diagnosing Glaucoma. Vision Institute Annual Fall Conference

The Visual System. Retinal Anatomy Dr. Casagrande February 2, Phone: Office: T2302 MCN

FACING YOUR FUNDIC FEARS: EXAMINATION OF THE OCULAR FUNDUS J. Seth Eaton, VMD, DACVO Cornell University Veterinary Specialists

Is this glaucoma? Leo Semes, OD Michael Chaglasian, OD Danica Marrelli, OD. Optometry s Meeting 2015 Seattle, WA

The Eye. The Orbit. The EYE What a Trip!!! - The Anterior Segment 5/12/2015. Jill J Luebbert, CPOT, ABOC

INTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany

When optical coherence tomography (OCT)

SPECIAL SENSES. Anatomy & Physiology

The Evolution of Fundus Perimetry

A Curious Case of Bilateral Optic Disc Edema Brittney Dautremont, DO, MPH

Differential diagnosis of the red eye. Carol Slight Nurse Practitioner Ophthalmology

Multifunctional 1050 nm Spectral Domain Oct System at 147 khz for Posterior Eye Imaging

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Surgical Anatomy Ear and Eye. Presenters: Dr. Jim Hurrell and Dr. Dennis McCurnin

Transcription:

SOCT Copernicus REVO Easy Operation (Full auto & Auto mode) Auto alignment (Z-position, C-gate, Focus, Tomogram) Voice guide (support patient through examination) Powerful analysis tools Enhanced tomograms - 2 µm (digital resolution) Widefield scans 12 x 12mm area Peripherial scanning Normative database Analysis program Retina Glaucoma Anterior Anterior - Angle to angle Import of fundus camera image* Multilingual interface * - Currently import and overlay are avaibale in manual mode only

SOCT Copernicus REVO 8 retina layer recognition Examination review: o Single exam analysis o Asymmetry analysis o Follow up Retina analysis: Retina thickness, Inner retinal thickness, Outer retinal thickness, IS/OS thickness, RPE deformation Glaucoma analysis: Optic Nerve Head scan: RNFL, ONH morphology, DDLS Retina scan: Ganglion analysis as RNFL+GCL+IPL and GCL+IPL, OU and Hemisphere asymmetry Anterior analysis Pachymetry measurement, Epithelium map, LASIK flap, Angle measurement (AOD, TIA, TISA) 3D reconstruction

A Complete OCT Device Retina 2048lines/0.08sec Disc Cornea Anterior Wide Anterior

Retinal Analysis Single Exam Symmetry

Follow-Up Retinal Analysis Retina follow up analysis modes: Morphology view Quantification analysis Trend analysis

SOCT Copernicus REVO Central scan mode - 12 mm width (fovea and disc on one scan) Peripherial scans (Below are combined two examinations of peripheral area 12mm + 12 mm)

Averaging 2 µm Ultra High (Digital) Resolution

Enhance Depth modes Vitreous mode Choroid mode

Choroid visualisation

Clinical images Case 1 CSR Case 2

Clinical images Case 3 Case 4

Clinical images Case 5

Clinical images Case 6 Case 7

Glaucoma analysis Optic Nerve Head analysis Ganglion cells layer analysis Pachymetry and Gonioscopy

Corneal analysis Pachymetry map Epithelium thickness Zonal analysis IOP correction

Anterior Segment Imaging 2µm Ultra High Digital Resolution Cornea scan Epithelium Bowman s membrane Stroma Endothelium

Anterior Segment Imaging Anterior Angle scan Epithelium Schlemm s canal Schwalbe s line Endothelium Scleral spur Iris

Anterior Segment Imaging Back of the crystalline Lens Epithelium Posterior capsule Berger space Vitreous body membrane

Wide Anterior Segment Imaging Sclera and Angle Structrure Sclera Epithelium Schwalbe s line Schlemm s canal Iris Cornea

Wide Anterior Segment Imaging Enhance mode - Sclera and Angle Structrure Sclera Blood vessel Endothelium Pars plana Ciliary body Sclerar spur

Wide Anterior Segment Imaging Angle to Angle Sclerar Spur Iris Posterior pigment epithelium Lens Sclera

Wide Anterior Segment Imaging Wide scan with lens defect IOL observation

Lens fitting Contact lens on the cornea 4 mm scan Contact lens on the Cornea and the Sclera 10 mm

3 x 3 mm 3 x 3 mm OCT Angiography. Coming soon Depth coded view Superficial capillary plexus Deep capillary plexus

CLINICAL CAPABILITIES - Detect pathologies at earlier stages (e.g. detection small lipofuiscin changes in RPE as FAF does) - Elevate your practice profile - Raise diagnostic level by a broader range of services: - Manage a broader range of diseases - Glaucoma - Anterior part of the eye - Manage more advanced diseases - Verify periphery - Optimised practice workflow: - Technician performs the exam for the doctor to review and analyse the result (Thereby saving the doctors time and increasing the number of diagnostic reviews) - Networking is free of charge and does not require extra hardware. - Extremely easy and intuitive for operators at any level - Fast workflow to minimise patient chair time

CLINICAL CAPABILITIES - Visualise retinal conditions with ultra high-definition imaging (3µm digital) - Excellent B-scans quality - Wide scan of retina - Visualisation of choroid (new research confirms usability of verifying choroid thickness on enhanced scans similiar to swept source) - Qualitative and quantitative tools for clearer assessments of your patient's condition - Identity and monitor at-risk patients for glaucoma with comprehensive reports - Ganglion analysis allows detectection of glaucoma at an earlier stage - Hemisphere method for early stages of glaucoma and non typical cases. - Full ONH Analysis with DDLS factor - RNFL analysis - Non contact gonioscopy for every patient - Pachymetry - Advanced OCT technology in REAL compact solution (other compact requires floor footprint as regular devices.) - Widest refraction range allows you to scan higher groups of patients - Report Manager enables pre-define desired reports for rapid printing - Enhanced patient comfort by easy education. - Ability to scan the smallest pupil without dilating.

KEY FEATURES IN THIS PRICE SHELF - Automatic positioning (Full Auto, Auto) - Touch control* - Voice assistance support patient through examination - Excellent scan quality, Ultra High digital resolution - Real Small floor footprint (patient-operator one side) - Only USB connection cable (allows to use any type of efficient PC) - Central 12x12 mm Retina scan - Peripherial Scanning - Anterior scan without Adapter (only narrow scan) - White to white wide Anterior scan with Adapter (no foreahead support required) - Both Anterior option included in the price (all others charge extra) - Moveable & changeable shape of fixation target realised on the OLED display - Refraction range +/-25 D - Networking (Same functionality on review station, free of charge licences) * - when provided PC with touch screen

SOCT Copernic REVO technical data Technology: Scanning speed: Axial resolution: Resolution (digital) Lightsource Scan range Scan program Refraction range: Fixation target: Fundus observation PC interface Dimensions: Weight: Spectral domain OCT 27 000 A-scan/sec 5 µm 2 µm SLED 830 nm, 50nm width Retina 5 12mm Anterior 3 16 mm 3D, Raster, B-scan, Radial, Cross -25 D to 25 D OLED display (moveable positon, changeable shape) OCT live reconstruction USB 3.0 390 x 551 x 450 mm (WxDxH) 23 kg