FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

Similar documents
The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

What you need. When you need it. EV1000 Clinical Platform

Capture every aspect of hemodynamic status

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences

61% SvO 2. Clarity. Simplified.

An early warning indicator of tissue hypoxia.

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

Hemodynamic Monitoring and Circulatory Assist Devices

86% P(iBP) Hypotension. Clarity

Cogent 2-in-1 Hemodynamic Monitoring System

61% SvO 2. Clarity. Simplified.

Admission of patient CVICU and hemodynamic monitoring

What is. InSpectra StO 2?

Sepsis Wave II Webinar Series. Sepsis Reassessment

Goal-directed vs Flow-guidedresponsive

Early detection. Proactive intervention.

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

Impedance Cardiography (ICG) Method, Technology and Validity

Edwards Critical Care Education

Shock, Monitoring Invasive Vs. Non Invasive

Nurse Driven Fluid Optimization Using Dynamic Assessments

Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy

福島県立医科大学学術成果リポジトリ. Title laparoscopic adrenalectomy in patie pheochromocytoma. Midori; Iida, Hiroshi; Murakawa, Ma

FUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART

Hemodynamic monitoring beyond cardiac output

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

IN THE NAME OF GOD SHOCK MANAGMENT OMID MORADI MOGHADDAM,MD,FCCM IUMS ASSISTANT PROFESSOR

Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill

IABP Timing & Fidelity. Pocket Reference Guide

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Cardiac Output Monitoring - 6

Case scenario V AV ECMO. Dr Pranay Oza

Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU

CARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah

Hemodynamic Monitoring

Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy

Biomedical Instrumentation E. Blood Pressure

Early Goal-Directed Therapy

How to maintain optimal perfusion during Cardiopulmonary By-pass. Herdono Poernomo, MD

Pre-operative usage of IABP for patients for by pass surgery

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device

ECCE. Edwards Critical Care Education. Q UICK G UIDE T O Cardiopulmonary Care 3 RD E DITION

ACUTE RESPIRATORY DISTRESS SYNDROME (ARDS) Rv

Capnography: The Most Vital of Vital Signs. Tom Ahrens, PhD, RN, FAAN Research Scientist, Barnes-Jewish Hospital, St. Louis, MO May, 2017

Georgios C. Bompotis Cardiologist, Director of Cardiological Department, Papageorgiou Hospital,

Fluid bolus of 20% Albumin in post-cardiac surgical patient: a prospective observational study of effect duration

Fluids in Sepsis: How much and what type? John Fowler, MD, FACEP Kent Hospital, İzmir Eisenhower Medical Center, USA American Hospital Dubai, UAE

DESIGNER RESUSCITATION: TITRATING TO TISSUE NEEDS

APPENDIX VI HFOV Quick Guide

Invasive Cardiac Output Monitoring and Pulse Contour Analysis. Harshad B. Ranchod Paediatric Intensivist Chris Hani Baragwanath Hospital COPICON 2011

Sepsis Combine experience and Evidence. Eran Segal, MD Director General ICU, Sheba Medical Center, Israel

Obligatory joke. The case for why it matters. Sepsis: More is more. Goal-Directed Fluid Resuscitation 6/1/2013

Establishing the New Standard of Care for Inoperable Aortic Stenosis THE PARTNER TRIAL COHORT B RESULTS

Review Article. Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems. Introduction

Disclaimer. Improving MET-based patient care using treatment algorithms. Michael R. Pinsky, MD, Dr hc. Different Environments Demand Different Rules

Goal-directed resuscitation in sepsis; a case-based approach

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

12/1/2009. Chapter 19: Hemorrhage. Hemorrhage and Shock Occurs when there is a disruption or leak in the vascular system Internal hemorrhage

TOPIC : Cardiogenic Shock

PulsioFlex Patient focused flexibility

When Cyanosis is the Norm. Steven M. Schwartz, MD, FRCPC Cardiac Critical Care Medicine The Hospital for Sick Children Toronto

Nothing to Disclose. Severe Pulmonary Hypertension

Edwards Critical Care Education. Perioperative Goal-Directed Therapy Protocol Summary

EVOLUCIÓN DE LA MONITORIZACIÓN CARDIOVASCULAR EN LA UCI

CARDIAC OUTPUT Monitoring ANDY CAMPBELL JOURNAL CLUB NOV 2011

Edwards Critical Care Education. Perioperative Goal-Directed Therapy Protocol Summary

QUIZ 1. Tuesday, March 2, 2004

FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL

UNIVERSITY OF UTAH HEALTH CARE HOSPITALS AND CLINICS

Hemodynamic Monitoring in Critically ill Patients in Arthur Simonnet, interne Tuteur : Pr. Raphaël Favory

Fluid responsiveness and extravascular lung water

Non-Invasive Monitoring

Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring

Shock and hemodynamic monitorization. Nilüfer Yalındağ Öztürk Marmara University Pendik Research and Training Hospital

Rounds in the ICU. Eran Segal, MD Director General ICU Sheba Medical Center

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

EVALUATING HEMODYNAMICS WITHOUT FANCY EQUIPMENT

UTILITY of ScvO 2 and LACTATE

Standard Operating Procedure (SOP) Management of intervention group patients SOP 001

Minimally invasive cardiac output monitors

The Use of Dynamic Parameters in Perioperative Fluid Management

Edwards Critical Care Education. Perioperative Goal-Directed Therapy Protocol Summary

Cardiopulmonary System

Useful Ectopics: Case Study. Effects of vasodilation and the diagnostic value of ectopic heartbeats

Capnography (ILS/ALS)

Cardiovascular Responses to Exercise

DO 2 > VO 2. The amount of oxygen delivered is a product of cardiac output (L/min) and the amount of oxygen in the arterial blood (ml/dl).

Staging Sepsis for the Emergency Department: Physician

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

6/5/2014. Sepsis Management and Hemodynamics. 2004: International group of experts,

Cardiovascular Management of Septic Shock

Frank Sebat, MD - June 29, 2006

SCVMC RESPIRATORY CARE PROCEDURE

Transcription:

Edwards FloTrac Sensor & Edwards Vigileo Monitor FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations 1

Topics System Configuration FloTrac Sensor and PreSep Catheter Thoracotomy Central venous saturation (ScvO 2 ) & ventilation changes Cardiac output & ventilation changes Cardiac output & volume resuscitation FloTrac Sensor and PreSep Catheter Exp Laparotomy Cardiac output and surgical blood loss Stroke volume variation volume resuscitation guide ScvO 2 & cardiac output 2

System Configuration PreSep Catheter (ScvO 2 ) Venous Oximetry Vigileo Monitor Cardiac Output FloTrac Sensor (peripheral artery) The Vigileo monitor by Edwards Lifesciences supports both the FloTrac sensor for continuous cardiac output and the PreSep central venous catheter for continuous central venous oximetry (ScvO 2 ) 3

Vigileo Monitor Continuously computes stroke volume from the patients arterial pressure signal Displays key hemodynamic parameters on a continuous basis (every 20 sec) Requires NO manual calibration The user simply enters patient age, gender, height and weight to initiate monitoring Advanced waveform analysis compensates for: Patient-to-patient differences in vasculature Real time changes in vascular tone Differing arterial sites Venous oximetry available when used with appropriate Edwards oximetry technology The Vigileo monitor continuously displays and updates Continuous Cardiac Output, Cardiac Index, Stroke Volume, Stroke Volume Index, Systemic Vascular Resistance*, Systemic Vascular Resistance Index*, and Stroke Volume Variation every 20 seconds when used with the FloTrac Sensor. DO 2 and DO 2 I are also available for intermittent calculation.** These parameters help guide the clinician in optimizing stroke volume through precision guided management of preload, afterload, and contractility. Vascular tone = vessel compliance and resistance Vigileo then helps identify the adequacy of cardiac output by monitoring central venous (ScvO 2 ) or mixed venous (SvO 2 ) oxygen saturation when used with Edwards venous Oximetry technologies. * These parameters require the CVP value to be slaved from bedside monitor for continuous monitoring. SVR/SVRI can also be assessed on the Derived Value Calculator for intermittent calculations using either slaved or manually entered MAP, CVP, and CO values. **These parameters require the SpO 2 and PaO 2 values to be manually entered. If CO is being continuously monitored, the calculator will default to the existing CO value. Otherwise, the user may override the continuous value to manually enter CO. 4

FloTrac Sensor The specially designed FloTrac sensor provides the high fidelity arterial pressure signal required by the Vigileo monitor to calculate the stroke volume The Vigileo monitor uses the patient s arterial pressure waveform to continuously measure cardiac output. With inputs of height, weight, age and gender, patient-specific vascular compliance is determined. The FloTrac sensor measures the variations of the arterial pressure which is proportional to stroke volume. Vascular compliance and changes in vascular resistance are internally compensated for. Cardiac output is displayed on a continuous basis by multiplying the pulse rate and calculated stroke volume as determined from the pressure waveform. The FloTrac sensor is easily setup and calibrated at the bedside using the familiar skills used in pressure monitoring. 5

Clinical Cases 6

Intraoperative Case Study #1 68-year-old female Right thoracotomy FloTrac sensor and PreSep catheter 68-year-old female undergoing a right thoracotomy for a lobectomy. The patient was intubated with a bifurcated endotracheal tube to allow for ventilation of the right and/or left lung. The following slides illustrate the effects of independent lung ventilation on CO and ScvO 2. 7

Intraoperative Case Study #1 4.Extubated 3.Inflate Right Lung 1.DeflatedRight Lung 2.Volume Infusion Events noted on the graph: Light line on top is ScvO2. Dark line below is cardiac output. After deflation of the Right Lung, ScvO 2 falls followed shortly thereafter by a drop in cardiac output signal. ScvO 2 decreases due to both decreasing arterial oxygenation and decreasing cardiac output. Cardiac output falls due to an increase in PVR, increasing right ventricular afterload, impeding right ventricular ejection and thus decreasing left ventricular preload. Changes in cardiac output due to volume resuscitation. ScvO 2 did not rise as the lung was still deflated. In many cases ScvO 2 trends with CO. However, since the changes in cardiac output with volume challenges were probably transient and not associated with decreases in intrapulmonary shunt, ScvO2 would not be expected to increase. This is an example of CO increasing while there is no effect on ScvO 2. After re-inflation of the collapsed lung, pulmonary vascular resistance decreased, decreasing right ventricular afterload and allowing cardiac output to increase slowly., Presumably right lung reinflation reduced intrapulmonary shunt. This phase of the recording demonstrates that ScvO 2 changes are not always induced by CO changes. 8

Intraoperative Case Study #2 72-year-old female Laparotomy for tumor removal FloTrac sensor and PreSep catheter This is an example of a case involving a sudden exsanguination. The clinician used the FloTrac sensor to measure CO, SV and SVV to help guide volume resuscitation. 9

Intraoperative Case Study #2 1. Two Liter blood loss 4. Packed Red Blood /NaCl 5. Extubate 2. Volume Resuscitation NaCl 3. Packed Red Blood The above case is an exploratory laparotomy with tumor removal. Both the FloTrac sensor and the PreSep catheter were used in addition to traditional vital signs. 1) 2.17p The patient experienced a sudden loss of blood during the procedure. Note the low CO and decreasing ScvO 2. 2) 2.23p Saline volume resuscitated and 3. packed red blood cells were rapidly infused. Note the step up increases in CO but still persistent under-resuscitation, as noted by the persistently low ScvO 2. Stroke volume variation (SVV) was used as a guide for starting and stopping volume resuscitation at the points shown by the arrows. 3) 2.54p and 3.08p To address the inadequate O2 delivery more packed red blood cells were infused which increased both CO and ScvO 2. 4) 3.15p Once stable following surgery, the patient was extubated. The following slides demonstrate the patient s response to resuscitation at the point highlighted by the second arrow above. 10

Intraoperative Case Study #2 SVV progressively decreased from 2.21p to 2.23p after bolus fluid resuscitation. However, SVV continued to increase again until at 2.27p it peaked at 19% with a stroke volume of 45 ml/beat. Thus, even though the CO may have appear borderline adequate, the SVV demonstrated marked increasing preload-dependency, consistent with on going bleeding. The patient received one unit of packed red blood cells and 500ml Normal Saline. 11

Intraoperative Case Study #2 After resuscitation the SVV decreased to between 9-6% with a Stroke Volume increase to approximately 60 ml/beat. One aberrant reading of 25% (at 2:32 p) was due to an arrhythmia. 12

How Can One Use SVV? PRBC & Normal Saline infused with SVV of 19% and CO of 3.4 l/min SVV of 9% and CO of 4.5 l/min after infusion As displayed in the numerical trend screen, the graphical trend screen an increase in CO in response to volume resuscitation in a hypovolemic patient. 13

ScvO 2 and Cardiac Output Increase in ScvO2 with Decrease in CO Decrease in CO with minimal change in ScvO2 This same screen shot also shows that central venous oxygenation (ScvO 2 ) does not always follow cardiac output. This is an important example of how these two parameters can be independent of each other. These paired trends show an parallel though not tightly linked increase in CO and ScvO2 in a hypovolemic patient in response to volume resuscitation. Cardiac output is a major component of oxygen delivery (DO 2 = Cardiac Output x Oxygen Content) ScvO 2, like SvO 2 is affected by Oxygenation, Hemoglobin, Cardiac Output and Oxygen Consumption ScvO 2 and cardiac output together are powerful tools in monitoring both oxygen delivery and its balance with oxygen consumption. DO 2 = Oxygen Delivery 14

Summary CO and ScvO 2 are useful in understanding the effects of mechanical ventilation Blood loss is quickly demonstrated by changes in cardiac output Volume resuscitation is effectively guided by SVV and stroke volume changes ScvO2 and CO can be independent ScvO2 and CO together is a powerful tool 15

Rx only. See instructions for use for full prescribing information. Edwards Lifesciences devices placed on the European market meeting the essential requirements referred to in Article 3 of the Medical Device Directive 93/42/EEC bear the CE marking of conformity. Edwards, the stylized E logo, FloTrac and Vigileo are trademarks of Edwards Lifesciences Corporation. Edwards Lifesciences, and PreSep are trademarks of Edwards Lifesciences Corporation and are registered in the United States Patent and Trademark Office. 2006 Edwards Lifesciences LLC All rights reserved. AR01258 16