ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Similar documents
Design Rationale. ECHELON Primary Hip System

Specifications guide ECHELON. Hip System

AML Hip System. Design Rationale/ Surgical Technique

Optimum implant geometry

Reaching new heights. Comprehensive. Efficient. Simple.

Bone Preservation Stem

Comprehensive. Simple. Efficient.

Optimum implant geometry

Clinical Evaluation Surgical Technique

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

28 Surgical Technique

Optimum implant geometry

PLR. Proximal Loading Revision Hip System

HIP SYSTEM SURGICAL TECHNIQUE

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Featuring. Technology. Product Rationale

One system for all revision types

Approach Patients with Confidence

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

EMPERION Modular Hip System was designed in conjunction with: Robert Barrack, MD St. Louis, MO. Mathias Bostrom, MD New York, NY

Surgical Technique r5.indd 1 12/8/10 10:36 AM

FLH /11

Surgical Technique. Hip System

Approach Patients with Confidence

CPCS. Training Manual. Collarless Polished Cemented Stem

Preoperative Planning. The primary objectives of preoperative planning are to:

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Tradition Hip Primary Surgical Technique

9800 Metric Blvd. Austin, Texas

S U R G I C A L T E C H N I Q U E

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

The Leader in Orthopaedic Innovation

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

PROFEMUR Total Hip System P R O D U C T C A T A L O G

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Bone Bangalore

Revision. Hip Stem. Surgical Protocol

Metha Short Hip Stem System

Arcos Modular Femoral Revision System

Inspiring people, Enriching lives

Hip Product Brochure

TOTAL HIP REPLACEMENT:

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Cementless Tapered Femoral Stem Surgical technique

EMPERION Modular Hip System Surgical Technique

LPS SYSTEM POCKET GUIDE

Progeny Hip Stem. Surgical Protocol and Product Specifications

Restoration Modular Revision Hip System. Choice Matters

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Zimmer Segmental System

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

ZMR Porous Revision Hip Prosthesis. Surgical Technique IMAGE TO COME

TaperFill. Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

Distal Cut First Femoral Preparation

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

Taperloc Complete Hip System. Surgical Technique

Natural-Hip System. Surgical Technique. Addressing surgical concerns comprehensively

Answer. Hip System Design Features:

Integral 180 Surgical Technique

Approach Patients with CONFIDENCE

Surgical Technique. Cup System

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Continuing the Tradition. VerSys Heritage Hip System

Absolut TM Cemented Stem. Surgical Technique

VERSYS HERITAGE REVISION HIP PROSTHESIS. Surgical Technique for Revision Hip Arthroplasty

VerSys Fiber Metal Taper Hip Prosthesis. Surgical Technique

AVANTEON. Operative Technique & Catalogue Information AVANTEON

REFLECTION Constrained Liner Introduction

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

U2 PSA. Revision Knee. Surgical Protocol

ACETABULAR CUP SURGICAL TECHNIQUE

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

MetaFix. Cementless Total Hip Replacement Surgical technique

Common Instruments for Biomet Hip Systems

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

Manza Cup HA SURGICAL TECHNIQUE.

Basic Steps. Ream to Size. Broach and Trial. Implant Stem

Bi-Polar 22.2mm & 28mm System - Operative technique

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

ZMR Crossover Instruments. Abbreviated Surgical Technique

Fixed and Variable Geometry Total Shoulder Arthroplasty

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

REDAPT Revision Femoral System Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

REVISING THE DEFICIENT PROXIMAL FEMUR

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

VerSys 6 Beaded FullCoat Plus Hip Prosthesis

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

Duraloc CONSTRAINED LINER

Transcription:

E C H E L O N P R I M A R Y H I P S Y S T E M P R O D U C T R A T I O N A L E

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Echelon Primary Total Hip System HIGH OFFSET STANDARD OFFSET Cementless total hip arthroplasty has provided a proven method of treatment for several decades. The Echelon Primary Hip system incorporates the design concepts learned throughout this period to offer a femoral implant system that addresses the clinical needs of both surgeons and patients alike. By offering dual offset implants in 1 mm increments and simple yet precise instrumentation, the Echelon Primary Hip system offers the surgeon unprecedented intraoperative flexibility. For the patient, Echelon Primary stems are designed with the goal of providing long-term, pain-free restoration of joint function and normal hip biomechanics. 1

System Features The Echelon Primary total hip system has been designed to simply address the clinical issues surrounding total hip arthroplasty. Well-Designed Implants Many surgeons favor a cylindrical stem design. Stems of this configuration have shown excellent long-term clinical results using diaphyseal biologic 1, 2, 3 fixation. An extensively porous coated cylindrical stem offers many advantages. Solid fixation in the consistent cannular portion of the diaphysis. Simple, reproducible surgical technique. Proven long-term clinical results. Echelon implants also incorporate many design features that help the clinical success of the prosthesis. 1 mm increment sizes to precisely fit the implant to the patient, and not the other way around. Dual offsets for proper joint tension. Optimized medial curve to fill the proximal femur and avoid confusion. Threaded driver hole that accepts a locking stem inserter for implant control during insertion. Surgical Technique Echelon instruments have been designed to provide exact and reproducible results. Sharp reamers in 0.5 mm increments allow precise preparation of the femoral canal and permit the surgeon to choose the amount of press fit. Precision ground broaches easily prepare the proximal femur for the implant. A simple surgical technique avoids OR confusion. The prosthesis that is implanted is the same size as the final reamer and broach that are used. 2

Comprehensive System Echelon Primary implants are part of a family of femoral stems that address primary and revision situations. With one set of instruments, a variety of stems can be implanted. CEMENTED REVISION POROUS REVISION POROUS PRIMARY Acetabular Options Reflection Acetabular System Reflection acetabular shells and liners offer the perfect complement to the Echelon system. Available in a variety of options, each Reflection shell has a polished inner surface and uses the MicroStable liner locking mechanism which securely holds a selection of liners. Femoral Head Options Cobalt Chrome and Zirconia femoral heads precisely fit the 12/14 taper on the Echelon Primary stem. Smith & Nephew femoral heads offer an additional 19 mm of adjustment to ensure proper joint tension. 3

Addressing Implant Fixation Immediate and continued fixation of a total joint prosthesis has been correlated to the long-term clinical success of an implant. 4 Rough porous coating covers 2/3 of the Echelon Primary stem, along with distal flutes to help the implant achieve short-term and long-term biological fixation. Porous Coating Circumferential rough porous coating of sintered beads (RoughCoat TM ) covering 2/3 of the stem increases the friction between the implant and bone, improving implant stability and providing a porous surface for bone ingrowth. This helps reduce the initial movement of the prosthesis and results in implant stability which contributes to a lower incidence of pain. 5 This 2-3 bead layer coating has 30% average porosity and 270 microns average pore size which has been shown to be successful in bone in-growth. 6 Rotational Stability Distal flutes help increase rotational stability by providing immediate fixation upon implantation. The flutes on the distal portion of the stem are.25 mm larger than the porous coated diameter to provide extra penetration into the cortical bone for instant stability of the implant. Distal flutes that are.25 mm larger than the core diameter help achieve immediate implant fixation. MICROMOTION Micromotion (µ m) 120.0 100.0 80.0 60.0 40.0 20.0 00.0 1 2 3 4 Trial number Echelon 5/8 coated stem reamed.5 mm 5/8 coated stem reamed line-to-line The Echelon design was compared to a 5/8 porous coated cylindrical prosthesis for rotational stability. The distal flutes of the Echelon stem allowed significantly less rotational micromotion compared to the scratch fit of the 5/8 porous coated prosthesis. 7 4

Proximal Fill The proximal body of the Echelon Primary stem was designed to work in conjunction with distal fixation. Based on a study of more than 100 radiographs, the proximal geometry of the stem provides optimum fill and easy insertion of the implant. This is accomplished by incorporating a 3 A-P proximal flare and an optimized medial curve. A.5 mm press-fit is achieved between the broach and the implant providing an interference fit and enhancing initial fixation. mm 30 20 10 0 Echelon has a 3 proximal anterior/ posterior flare to improve proximal fill, without preventing implant seating. Reducing Stem Stiffness The effect of stem stiffness has been a concern of the long-term fixation of cylindrical stems. By design, cylindrical stems achieve tight distal fixation. However, this may lead to remodeling of the proximal femur. Although this has not led to significant clinical problems, researchers have concluded that the performance of distal fixation stems can be enhanced with increased stem flexibility. 8 Design 1 Design 2 Echelon 11.8 mm Furthermore, by optimizing the porous coating length and overall stem length, tight distal fixation can be achieved with less bone resorptive remodeling. 9 This provides for a more anatomic fit of the prosthesis which may also reduce thigh pain. LENGTH MEASUREMENTS Standard/ Porous High Offset Stem Coating Size Length Length 11-12 130 mm 90 mm 13-14 140 mm 96 mm 15-17 150 mm 102 mm 18-19 160 mm 108 mm Medial curves start at a higher location than other designs to avoid impingement. One optimized medial curve reduces O.R. confusion and delays. Design features such as the coronal slot help decrease the overall stiffness of the stem which may lead to less proximal stress shielding and decreased end-of-stem thigh pain. Echelon Primary stems are proportionally sized to better match patient anatomy and conserve bone. 5

Addressing Range of Motion Maximizing the patient s range of motion (ROM) without impingement of the prosthesis is an important clinical goal in preventing: 10 Increased poly debris which could lead to osteolysis Subluxation and possible joint dislocation Prosthetic loosening Dislodgement of a modular acetabular liner Echelon Primary stems have been designed to address these range of motion issues through implant design. Neck Geometry Optimizing neck geometry increases range of motion. The circulotrapezoidal neck on the Echelon Primary stem is designed to provide a greater range of motion than a circular neck. By using more material in the medial/lateral direction where fatigue requirements are higher, and less material in the anterior/posterior direction where demands are smaller, the range of motion is maximized. A Cylindrical Cross-section comparison of optimized (circulotrapezoidal) and cylindrical necks. L M Circulotrapezoidal P Head and Neck Size Prosthesis ROM correlates with the ratio of head diameter to neck thickness. It has been suggested that the minimum recommended ratio to achieve adequate range of motion is 2 to 1. 11 To achieve the recommended ratio with a 28 mm head, the maximum neck diameter should be 14 mm. The circulotrapezoidal neck on the Echelon Primary helps minimize neck thickness, thereby increasing ROM and reducing impingement which could lead to dislocation. 144û Circulotrapezoidal Neck 128û Cylindrical Neck 6 Effect of neck size on ROM.

Optimized 12/14 Taper The size of a taper connection affects ROM. Echelon Primary stems have an optimized 12/14 taper that is buried inside the femoral head for increased range of motion compared to other taper designs. A large taper that is exposed beyond the femoral head may impinge on the cup, limiting ROM. Skirted heads also have a negative impact on range of motion. 144û 144 102û 102 118û 118 Large exposed tapers or skirted heads decrease prosthesis ROM up to 40 percent. 12 Anteversion It is not necessary to build anteversion into the neck of the stem to maximize range of motion. Built-in anteversion does not increase range of motion it merely shifts the location of the ROM. With proper neck, taper, and acetabular liner geometry, a neutral stem neck can provide a greater ROM than a stem with a circular neck and built-in anteversion. ABDUCTION ECHELON 0 DEG CYLINDRICAL NECK DESIGN 10 DEG FLEXION EXTENSION ADDUCTION ROM for neutral circulotrapezoidal neck and anteverted circular neck were mapped on a two-dimensional plane. 7

Addressing Implant Design Many details were considered when designing the Echelon Primary femoral implants. Clinical performance along with surgical concerns have been addressed in the implant design. Femoral Offset Femoral offset is an important clinical requirement of proper joint function. When offset is not restored, medialization of the femur can occur resulting in impingement and possible instability. 13 Furthermore, when offset is not restored at the time of surgery, laxity of the soft tissues can occur resulting in weakness and possible dislocation. Echelon Primary stems are offered in Standard Offset and High Offset configurations to provide proper joint tension without affecting leg length or surgical technique. Femoral neck lengths are based on the Spectron Total Hip System which has 20 years of excellent clinical results. 11 mm Size Range Echelon Primary stems are proportionally sized. Larger diameter stems are longer and have more neck offset to accommodate the natural anatomy. 19 mm Implants are offered in 1 mm increments (11-19 mm) to better fit the patient. Distal Bullet Tip The bullet tip reduces the stress between the distal implant tip and the bone to minimize end-of-stem thigh pain. 8

Driving Platform The Echelon implants feature a threaded driving platform with an elliptical slot for rotational and axial implant control during insertion. Shoulder Relief A rounded shoulder has been incorporated into the design to ease insertion of the implant into the femur and reduce impingement of the implant into the greater trochanter which could cause fracture of the bone. Material All Echelon implants are manufactured from Cobalt Chromium which allows for extensive porous coating of the stem. To address stiffness concerns of Cobalt Chrome, the Echelon design was tested in a 4-point bend configuration. The Echelon stem demonstrated a reduced stiffness when tested in anterior/posterior and medial/lateral directions. 14 N/mm 6000 5000 4000 3000 2000 1000 0 STEM STIFFNESS 5/8 Coated Stem (13.5 mm) Echelon (15 mm) A four-point bend test was used to compare the stem stiffness of the Echelon design to a commonly used femoral implant. A/P M/L 9

Addressing Surgical Instrument Design Surgical instrument design is as equally important as the design of the implant itself. Echelon instruments have been designed to provide a simple, exact and reproducible surgical experience. Proximal Reamer A special reamer has been designed to open the proximal femur to ensure that subsequent reaming stays lateral. This proximal reamer can also be used to remove sclerotic bone. Reamers Sharp femoral reamers are available in.5 mm increments for exact preparation of the femoral canal. Clear depth marks indicate the appropriate reaming depth. Broaches Echelon broaches feature a tooth pattern that has been ground on a 5 axis machine. This tooth arrangement helps move bone chips up and out of the femoral canal which makes bone preparation straightforward and facilitates cleaning. Broach Handles Securely locking broach handles with a wide striking platform and a quick connect/disconnect facilitate easy broaching of the femoral canal. 10

Trial Necks To avoid confusion, Echelon trial necks are designed to work with the corresponding size of broach. Magnets are also embedded into the trial neck so that it stays in place when put through trial range of motion. Trial Heads A wide variety of trial heads are available (22, 26, 28, 32 mm) to address soft tissue variability and surgeon preference. Femoral heads along with the optimized 12/14 taper have been designed to reduce the number of skirted femoral heads. Stem Inserter Stem implantation is made easy with a rigid, threaded attachment mechanism. The locking stem inserter provides maximum control during implant seating. Anteversion Handles A simple, knurled handle threads into both the broach handle and stem inserter giving extra visualization and control during preparation and implantation. 11

Addressing Surgical Technique STEP 1. RESECT FEMORAL NECK WITH THE OSTEOTOMY GUIDE. STEP 2. OPEN FEMORAL CANAL WITH BOX OSTEOTOME. 4 12 3 STEP 3. PERFORM INITIAL FEMORAL REAMING WITH CANAL FINDER AND MODULAR T-HANDLE. STEP 4. REAM CANAL IN 0.5 MM INCREMENTS TO SELECTED SIZE. STEP 5. BROACH FEMUR TO SIZE DETERMINED BY LAST REAMER USED. 5

STEP 6. REAM THE CALCAR BONE WITH THE CALCAR REAMER, IF NECESSARY. STEP 7. PLACE THE TRIAL NECK ON THE BROACH AND PERFORM TRIAL REDUCTION. STEP 8. ASSEMBLE THE IMPLANT TO THE THREADED STEM INSERTER. STEP 9. SEAT THE IMPLANT TO THE DESIRED LEVEL. STEP 10. PERFORM FINAL TRIAL REDUCTION. STEP 11. ASSEMBLE THE FEMORAL HEAD ON TO THE STEM. 13

POROUS / PRIMARY REFERENCES 1. Engh, C., et al, Cementless Total Hip Arthroplasty Using the Anatomic Medullary Locking Stem, CORR, Number 249, December 1989. 2. Orthopedics Today, May 1997. 3. Engh, C., et al, Porous-Coated Total Hip Replacement, CORR, Number 298, January, 1994. 4. Whiteside, L. et al, The Effect of Collar and Distal Stem Fixation on Micromotion of the Femoral Stem in Uncemented Total Hip Arthroplasty, CORR, Number 239, February, 1989 5. Bobyn J., et al, Producing and Avoiding Stress Shielding, CORR, Number 274, January 1992. 6. Kienapfel, H., et al, Implant Fixation by Bone Ingrowth, J of Arthroplasty, Vol. 14, No. 3, April, 1999. POROUS / REVISION 7. Daigle, K. et al, Axial Insertion and Torque Testing of Two Fluted-Slotted Distal Designs, and Porous Coated Model in Simulated Cancellous Bone, Smith & Nephew Technical Report, OR-96-15, March, 1996. 8. Otani, T., et al, Effects of Femoral Component Material Properties on Cementless Fixation in Total Hip, JOA, Vol. 8 Number 1, 1993. 9. Nishii, T., et al, Longitudinal Evaluation of Time Related Bone Remodeling After Cementless THA, CORR, Number 339, June, 1997. 10. Impingement in THA: The Effect of Neck Geometry and Acetabular Design, Smith & Nephew Technical Publication, September 1998. 11. Chandler, D., et al, Prosthetic Hip Range of Motion and Impingement, The Effects of Head and Neck Geometry, CORR. Number 166, June 1982, pp. 284-291. 12. The Effect of Hip Implant Design Factors on the Incidence of Early Impingement, Smith & Nephew Technical Publication, December 1998. 13. McGrory, B., et al, Effect of Femoral Offset on Range of Motion and Abductor Muscle Strength After Total Hip Arthroplasty, JBJS, Vol. 77-B. Number 6, November 1995. 14. Daigle, K, Flexibility Analysis, Smith & Nephew Technical Memo, TM105801, April, 1998. CEMENTED / REVISION Smith & Nephew, Inc. 1450 Brooks Road Memphis, TN 38116 U.S.A. (901) 396-2121 For information: 1-800-821-5700 For orders and order inquiries: 1-800-238-7538 www.smithnephew.com/echelon Echelon, RoughCoat, Spectron, Reflection and Micro Stable are trademarks of Smith & Nephew, Inc. 2000 Smith & Nephew, Inc. 04/00 7138-0649