DURACLONE IF BE CERTAIN ABOUT THE RESPONSE. l res. a il n c n. For Research Use Only - Not for use in Diagnostic procedures

Similar documents
DURACLONE RE THERE ARE EVENTS YOU CANNOT AFFORD TO MISS

DuraClone IM. Standardized phenotyping panels for studies of the human immune system

a Beckman Coulter Life Sciences: White Paper

Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood

BD Flow Cytometry Reagents Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa X-20 Cell Analyzer

A step-by-step approach to build and analyze a multicolor panel

Naive, memory and regulatory T lymphocytes populations analysis

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay

Optimizing Intracellular Flow Cytometry

Fluorochrome Panel 1 Panel 2 Panel 3 Panel 4 Panel 5 CTLA-4 CTLA-4 CD15 CD3 FITC. Bio) PD-1 (MIH4, BD) ICOS (C398.4A, Biolegend) PD-L1 (MIH1, BD)

Application Information Bulletin: Cell Signaling

Ex vivo Human Antigen-specific T Cell Proliferation and Degranulation Willemijn Hobo 1, Wieger Norde 1 and Harry Dolstra 2*

In vitro human regulatory T cell expansion

In vitro human regulatory T cell expansion

Clinical question. Screening tube. Diagnostic panel MRD. Clinical question

Bead Based Assays for Cytokine Detection

Comprehensive evaluation of human immune system reconstitution in NSG. and NSG -SGM3 mouse models toward the development of a novel ONCO-HU

CyTOF analyses in rheumatoid arthritis. Deepak Rao, MD PhD Rheumatology, Immunology, Allergy, BWH

BD CBA on the BD Accuri C6: Bringing Multiplexed Cytokine Detection to the Benchtop

ezkine Th1/Th17 Whole Blood Intracellular Cytokine Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Optimizing Intracellular Flow Cytometry:

B and T-Cells. CD8+ Cytotoxic T Cells

FLOW CYTOMETRY PRINCIPLES AND PRACTICE. Toby Eyre Consultant Haematologist Oxford University Hospitals NHS Foundation Trust June 2018

MAIT cell function is modulated by PD-1 signaling in patients with active

Human Innate Lymphoid Cells: crosstalk with CD4 + regulatory T cells and role in Type 1 Diabetes

Recommended Protocols for Phospho Protein Detection in Human Cells

Page 1 of 2. Product Information Contents: ezkine Th1 Activation 2 Whole Blood Intracellular Cytokine Kit

The spectrum of flow cytometry of the bone marrow

Optimizing Intracellular Flow Cytometry:

AbSeq on the BD Rhapsody system: Exploration of single-cell gene regulation by simultaneous digital mrna and protein quantification

Commercially available HLA Class II tetramers (Beckman Coulter) conjugated to

CLINICAL USE OF CELLULAR SUBPOPULATION ANALYSIS IN BM

BD FACSCanto II. A proven platform for maximum reliability and the highest quality results

Blocking antibodies and peptides. Rat anti-mouse PD-1 (29F.1A12, rat IgG2a, k), PD-

Cytotoxicity assays. Rory D. de Vries, PhD 1. Viroscience lab, Erasmus MC, Rotterdam, the Netherlands

Dendritic Cell - T Cell Immune Network

T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells

Supplementary Data. Treg phenotype

Direct ex vivo characterization of human antigen-specific CD154 + CD4 + T cells Rapid antigen-reactive T cell enrichment (Rapid ARTE)

DIFFERENCES IN T-CELL SUBSETS IN ME/CFS. University of Nevada, Reno. Determining the Difference Between Circulating Follicular Regulatory T-cells and

FLOW CYTOMETRY CATALOG - Outside US Version

IMMUNOLOGY. Source, Isolate, Culture, And Analyze Immune Cells. Scientists Helping Scientists

Primary Adult Naïve CD4+ CD45RA+ Cells. Prepared by: David Randolph at University of Alabama, Birmingham

January 25, 2017 Scientific Research Process Name of Journal: ESPS Manuscript NO: Manuscript Type: Title: Authors: Correspondence to

VUmc Basispresentatie

Abnormalities of the Immune System and Inflammation in MDS Pathogenesis. Shahram Kordasti MSc(Med Imm), MD, PhD Department of Haematological Medicine

MACS Marker Screen. MACS Marker Screen. Catalog antibodies. antibodies CD4 (VIT4) CD11b. MACS Marker Screen antibodies. Catalog. antibodies CD2 CD14

DISCOVER MORE WITH LESS SAMPLE. nanostring.com/3d

MATERIALS. Peptide stimulation and Intracellular Cytokine Staining- EFFECTOR 45RA PANEL

TCR activation mimics CD127 low PD-1 high phenotype and functional alterations of T lymphocytes from septic shock patients

Annexin V-FITC Apoptosis Detection Kit with SYTOX

Welcome. Welcome. Emerging Technologies in Flow Cytometry

Supplemental Table I.

T-Cell Research. Novel multicolor flow cytometry tools for the study of CD4 + T-cell differentiation and plasticity

MHC Tetramers and Monomers for Immuno-Oncology and Autoimmunity Drug Discovery

Dendritic cell subsets and CD4 T cell immunity in Melanoma. Ben Wylie 1 st year PhD Candidate

BD Pharmingen. Human Th1/Th2/Th17 Phenotyping Kit. Technical Data Sheet. Product Information. Description Components:

MagniSort Human CD4 Memory T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Flow cytometry leukocyte differential : a critical appraisal

Fast and Easy Isolation of T Cells

MACS Cell Pre-Enrichment for flow sorting and analysis

Implementation of an ex-vivo Th17 Assay

Peptide stimulation and Intracellular Cytokine Staining

sequences of a styx mutant reveals a T to A transversion in the donor splice site of intron 5

Start your T cell research right

Annexin V APC Assay Kit

Monocyte subsets in health and disease. Marion Frankenberger

Evaluation of Drug Hypersensitivity by flow cytometry (technical session)

Muse Assays for Cell Analysis

Nature Immunology: doi: /ni Supplementary Figure 1. Examples of staining for each antibody used for the mass cytometry analysis.

- 1 - Cell types Monocytes THP-1 cells Macrophages. LPS Treatment time (Hour) IL-6 level (pg/ml)

UNISEC Universal Influenza Vaccines Secured

Annexin V-Cy3 Apoptosis Detection Reagent

Kerrie Clerici, Michael Swain, Dominic Fernandez, Julia Schulz, Matthew Archer, Janine Campbell

Instructions. Fuse-It-mRNA easy. Shipping and Storage. Overview. Kit Contents. Specifications. Note: Important Guidelines

PBMC from each patient were suspended in AIM V medium (Invitrogen) with 5% human

CHAPTER 3 LABORATORY PROCEDURES

Effector T Cells and

In vitro expansion of mouse CD4 + T cells

Cover Page. The handle holds various files of this Leiden University dissertation.

MagniSort Mouse CD4 Naive T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Page 1 of 3. Product Information Contents: ezkine CD8 Activation 2 Whole Blood Intracellular Cytokine Kit

Supplementalgfigureg1gSchematicgdiagramgofgtumor1modellingg

ab Hepatic Lipid Accumulation/ Steatosis Assay Kit

What to Measure, How to Measure It

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Supplementary Table; Supplementary Figures and legends S1-S21; Supplementary Materials and Methods

Bezzi et al., Supplementary Figure 1 *** Nature Medicine: doi: /nm Pten pc-/- ;Zbtb7a pc-/- Pten pc-/- ;Pml pc-/- Pten pc-/- ;Trp53 pc-/-

Supplemental Figure 1. CD69 antigen-response curves of CAR engrafted Jurkat T cells. Supplemental Figure 2.

Clinico-cytometric classification of PNH

Supplementary Figure 1: TSLP receptor skin expression in dcssc. A: Healthy control (HC) skin with TSLP receptor expression in brown (10x

Instructions for Use. APO-AB Annexin V-Biotin Apoptosis Detection Kit 100 tests

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Figure S1. Western blot analysis of clathrin RNA interference in human DCs Human immature DCs were transfected with 100 nm Clathrin SMARTpool or

Categorical analysis of human T cell heterogeneity with One-SENSE

Rapid antigen-specific T cell enrichment (Rapid ARTE)

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Supplementary Fig. 1: Ex vivo tetramer enrichment with anti-c-myc beads

IMMUNE CELL SURFACE RECEPTORS AND THEIR FUNCTIONS

Instructions. Fuse-It-Color. Overview. Specifications

Transcription:

DURACLONE IF earch tria l res lc a om ic il n c n nio pa Yo ur BE CERTAIN ABOUT THE RESPONSE For Research Use Only - Not for use in Diagnostic procedures

BE CERTAIN ABOUT THE RESPONSE The sensitive and specific characterization of a cytokine response at the single cell level demonstrates the unique strength of cytometry. When using dry pre-formulated DuraClone IF antibody panels you can be certain that the detection of cellular responses is not biased by antibody pipetting variability or suboptimal panel design. Heterogeneity of TNFa production in T cell subpopulations (data obtained from normal whole blood upon stimulation, acquired on Navios cytometer). Definition of CD4+ T Helper Cell subpopulations due to their differential cytokine production (data obtained from normal whole blood upon stimulation, acquired on Navios cytometer).

DuraClone IF PANELS Antibody Combinations for Immune Functional Cytometry The DuraClone IF panels reveal immune function at the single cell level utilizing a streamlined and simplified intracellular staining workflow. Pre-formulated 4-6 color antibody panels Unitized dry Beckman Coulter proprietary format Expert-proven marker combinations 25 tests/package 405 nm 488 nm 633 nm Product PB KrO FITC PE ECD PC5.5 PC7 APC AF700 AF750 IF T Activation B88649 (25 tests RUO) CD4 - IFNg TNFa - - IL-2 - CD8 CD3 IF T Helper Cell C04666 (25 tests RUO) IL-17A - IFNg - - - IL-4 CD4 - CD3 IF Monocytes Activation (2017, configuration not final) CD14 CD45 - HLA-DR - - - - TNFa - Quality Standard ISO 9001-2008 Assay tubes and compensation kits contain identical tandem dye-labeled antibodies to assure accurate and easy compensation. Advancing Science Through Discovery

FLEXIBILITY TO ADAPT TO YOUR RESEARCH The DuraClone IF panels accommodate drop-in markers with bright and broadly available labels such as PE or APC so you can adapt the panels to your specific research needs. Example for adaption of the IF T Activation tube with anti-car-apc and CD107a-PC5.5 drop-in markers. Data was acquired on a Navios cytometer, kindly provided by Dr. Agnieszka Blum/Charite Berlin. Example for adaption of the IF T Helper Cell tube with CRTH2-PE and CD161-PC5.5 drop-in markers. Data was acquired on a Navios cytometer.

STREAMLINE YOUR WORKFLOW WITH DuraClone IF In the DuraClone IF kits every assay tube contains a layer with the dried-down antibody panel. The elimination of antibody pipetting shortens the turn-around-time, minimizes human error sources and purges the workflow from repetitive actions that are expensive to automate. Workflow for DuraClone IF Panels + + + + t Add fixation to simulated blood & incubate Wash Permeabilize / stain in DuraClone tube Wash Acquire The DuraClone IF kits are optimized for use with the PerFix-nc kit (B31167) allowing for staining of surface and intracellular antigens in a single step. Advancing Science Through Discovery

DuraClone IF DATA EXAMPLES Detection of proinflammatory cytokines in T cells IF T Activation PB KrO FITC PE ECD PC5.5 PC7 APC AF700 AF750 Quality Standard B88649 (25 tests RUO) CD4 - IFNg TNFa - - IL-2 - CD8 CD3 ISO 9001-2008 Detection of Th1/Th2/TH17 signature cytokines in T helper cells IF T Helper Cell PB KrO FITC PE ECD PC5.5 PC7 APC AF700 AF750 Quality Standard C04666 (25 tests RUO) IL-17A - IFNg - - - IL-4 CD4 - CD3 ISO 9001-2008

MORE DuraClone PANELS DuraClone IM for Immune System Research The dry DuraClone IM antibody panels provide a comprehensive image of the immune system applying dry expert-proven antibody combinations that are easy to implement. Designed by expert labs from 405 nm 488 nm 633 nm Product PB KrO FITC PE ECD PC5.5 PC7 APC AF647 AF700 APC- AF700 APC- AF750 IM Phenotyping Basic Tube B53309 (25 tests RUO) - CD45 CD16 CD56 CD19 - CD14 CD4 - CD8 - CD3 IM B Cell Tube B53318 (25 tests RUO) IgM CD45 IgD CD21 CD19 - CD27 CD24 - - - CD38 IM T Cell Subsets Tube B53328 (25 tests RUO) CD57 CD45 CD45RA CCR7 CD28 PD1 CD27 CD4 - CD8 - CD3 IM Dendritic Cells Tube B53351 (25 tests RUO) HLA-DR CD45 CD16 Lineage ** - CD1c CD11c Clec9A - - CD123 - IM TCRs Tube B53340 (25 tests RUO) TCRVd2 CD45 TCRgd TCRab HLA-DR - TCRVd1 CD4 - CD8 - CD3 IM Treg Tube B53346 (25 tests RUO) Helios CD45 CD45RA CD25 - CD39 CD4 - FoxP3 - - CD3 IM Granulocytes Tube B88651 (25 tests RUO) CD15 CD45 CD294 - CD16 CD33 CD11b PD-L1 - - Lineage *** CD62L IM Count Tube C00162 (25 tests RUO) - - CD45 Counting Beads 7-AAD - - - - - - Quality Standard ISO 9001-2008 ** CD3 / CD19 / CD20 / CD14 / CD56 *** CD3 / CD14 / CD19 / CD56 DuraClone RE for Rare Event Detection The dry DuraClone RE panels enable sensitive detection of rare abnormal cell populations in blood or bone marrow using carefully optimized and highly dosed antibody combinations. 405 nm 488 nm 633 nm Product PB KrO FITC PE ECD PC5.5 PC7 APC APC- AF700 APC- AF750 RE CLB Tube B80393 (25 tests RUO) CD20 CD45 CD81 ROR-1 - CD79b CD19 CD5 - CD43 RE PC Tube B80394 (25 tests RUO) CD38 CD45 CD81 CD27 - CD19 CD200 CD138 - CD56 RE ALB Tube C00163 (25 tests RUO) - CD45 CD58 - CD34 CD10 CD19 - CD38 CD20 Quality standard ISO 9001-2008 PB: Pacific Blue* KrO: Krome Orange AF647: Alexa Fluor* 647 AF700: Alexa Fluor* 700 AF750: Alexa Fluor* 750 APC-AF700: APC-Alexa Fluor* 700 APC-AF750: APC-Alexa Fluor* 750 Advancing Science Through Discovery

Choose Beckman Coulter for Benchmark Expertise and Innovation For over 80 years Beckman Coulter has driven innovation. We remain committed to shaping flow cytometry technology to fit seamlessly into your lab s workflow and to provide an optimal user experience. When you choose a Beckman Coulter solution you receive the a high level of expertise, innovation, and quality assurance. Contact your local Beckman Coulter sales representative. or visit http://beckman.com/en-us/flow-cytometry/popular-products/duraclone solutions for Immune functional cytometry For Research Use Only - Not for use in Diagnostic procedures 2017 Beckman Coulter, Inc. All rights reserved. Beckman Coulter, the stylized logo, and the Beckman Coulter product and service marks mentioned herein are trademarks or registered trademarks of Beckman Coulter, Inc. in the United States and other countries. * Alexa Fluor and Pacific Blue are registered trademarks of Molecular Probes, Inc. For Beckman Coulter s worldwide office locations and phone numbers, please visit Contact Us at beckman.com/home FLOW-2666SB05.17