Applying Sandwich Techniques for Complex Aortoiliac and Thoracoabdominal Aortic Aneurysms

Similar documents
Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

Endovascular Treatment of Complex Aortic Aneurysms Using the Sandwich Technique

Endovascular aneurysm repair (EVAR) has evolved to

Bell-bottoms, trouser grafts and crossovers: Maintaining pelvic perfusion with endovascular repair of aorto bi-iliac aneurysms

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Retrograde Embolization of a Symptomatic Hypogastric Artery Aneurysm

Preserved Pelvic Circulation After Stent-Graft Treatment of Complex Aortoiliac Artery Aneurysms: A New Approach

Safety of coil embolization of the internal iliac artery in endovascular grafting of abdominal aortic aneurysms

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

Management of the hypogastric artery during EVAR. Francesco Torella Liverpool Vascular & Endovascular Service

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Residual Dissection and False Lumen Aneurysm After TEVAR

Durable outcomes. Proven performance.

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

EVAR replaced standard repair in most cases. Why?

Endovascular options of treating iliac aneurysms

Acute dissections of the descending thoracic aorta (Debakey

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Why Nellix? Treating Concomitant Common Iliac Aneurysms

Percutaneous Approaches to Aortic Disease in 2018

Talent Abdominal Stent Graft

Access More Patients. Customize Each Seal.

Internal iliac artery aneurysms: When to intervene and outcomes of EVAR

CUSTOM-MADE SCALLOPED THORACIC ENDOGRAFTS IN DIFFERENT HOSTILE AORTIC ANATOMIES

Challenging anatomies demand versatility.

The Distal Seal Zone in AAA Repair A facet of EVAR that is not to be overlooked.

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE)

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

How effective is preservation when viewed through a clinical and economic lens?

LOWERING THE PROFILE RAISING THE BAR

The sandwich technique to treat complex aortoiliac or isolated iliac aneurysms: Results of midterm follow-up

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

Thoracoabdominal Aorta: Advances and Novel Therapies

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

My personal experience with INCRAFT in standard and challenging cases

Outcomes of endovascular repair of isolated iliac artery aneurysms. A. Stella

Endovascular management of iliac aneurysmal disease with hypogastric artery preservation

Reimbursement Guide Zenith Fenestrated AAA Endovascular Graft

Anatomical challenges in EVAR

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY

Abdominal and thoracic aneurysm repair

Early Experience with the GORE EXCLUDER Iliac Branch Endoprosthesis

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

for Thoracoabdominal Aneurysms

Abdominal aortic aneurysms (AAAs) are a

Aortic stents, types, selection, tricks in deployment.

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

Hybrid Repair of a Complex Thoracoabdominal Aortic Aneurysm

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

Technique and Outcome of Laser Fenestration For Arch Vessels

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

One Year Experience of Iliac Bifurcated Device for Aortoiliac Aneurysm in a Korean Single Center

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

Endovascular and Hybrid Treatment of TASC C & D Aortoiliac Occlusive Disease

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when?

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

State of Art Hybrid Approach

Expert Discussion: When to Preserve the Hypogastric Artery

Endovascular repair of an aortic arch pseudoaneurysm with double chimney stent grafts: a case report

Quick Reference Guide

A New EVAR Device for Infrarenal AAAs

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Scientific Exhibit Authors: J. M. M. Sanchis Garcia, J. Palmero da Cruz, J. Guijarro

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Hybrid aortic repair with antegrade supra-aortic and renovisceral debranching from ascending aorta

Hypogastric Preservation Using Retrograde Endovascular Bypass

Ancillary Components with Z-Trak Introduction System

The variation of carotid origin, the divergent orientation of common carotid (frequent posterior and left to right direction of right common as

HYPOGASTRIC ARTERY PRESERVATION DURING EVAR: SURGICAL AND ENDOVASCULAR TECHNIQUES Single Centre Experience. Ilaria Ficarelli

Anatomical applicability of current off-the-shelf branched endografts in thoracoabdominal aortic aneurysms managed by open surgery.

Percutaneous Axillary Artery Access For Branch Grafting for complex TAAAs and pararenal AAAs: How to do it safely

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

EVAR and TEVAR: Extending Their Use for Rupture and Traumatic Injury. Conflict of Interest. Hypotensive shock 5/5/2014. none

Abdominal Aortic Aneurysm 가천대길병원 이상준

Development of a Branched LSA Endograft & Ascending Aorta Endograft

US clinical trial update on the Gore Excluder iliac branch endoprosthesis (IBE)

Development of Stent Graft. Kato et al. Development of an expandable intra-aortic prothesis for experimental aortic dissection.

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Redo treatment and open conversion after TEVAR

patients 8 and are sufficiently debilitating that some authors 14 have combined the procedure with external-tointernal

Complications of EVAR

Endovascular aortic stent grafts have forever

Endovascular therapy for Ischemic versus Nonischemic complicated acute type B aortic dissection (catbad).

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Durability of The Endurant Stent-Graft through 5 Years

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Paraplegia in endovascular repair of TAA and in TEVAR: Incidence, prevention and therapy. Johannes Lammer Medical University Vienna, Austria

Endoanchor-assisted TEVAR

Step by step Hybrid procedures in peripheral obstructive disease. Holger Staab, MD University Hospital Leipzig, Germany Clinic for Vascular Surgery

Transcription:

Applying Sandwich Techniques for Complex Aortoiliac and Thoracoabdominal Aortic Aneurysms Tips and tricks to optimize the interventional experience. BY ARMANDO C. LOBATO, MD, PhD; LUCIANA CAMACHO-LOBATO, MD, PhD; MARCELO CURY, MD; CAMILA KOLBER, MD; AND JOSE REGINALDO SIMÃO, MD An AIA extending to the HA requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone... Common iliac artery aneurysms (CIAAs) are found in 20% to 30% of patients with abdominal aortic aneurysms. 1 An aortoiliac aneurysm (AIA) extending to the hypogastric artery (HA) requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent graft limb(s), a potential site for endoleak. It is possible to extend the iliac limb of the stent graft past the origin of one HA to provide a secure seal; however, bilateral HA occlusion can be problematic in 12% to 45% of cases. 2-4 Buttock claudication, ischemic colitis, neurologic deficits, bowel or bladder dysfunction, and erectile dysfunction are complications that can be caused by HA interruption. A few open and/or endovascular techniques have been developed over the past decade to increase the success rate of endovascular abdominal aortic aneurysm and CIAA repair, extending to the iliac bifurcation. 5-10 The bell-bottom technique can address common iliac arteries with diameters from 18 to 24 mm. 11,12 Enlargement of the CIAA diameter over time has been reported and may undermine the long-term durability of this technique. 13 The iliac branched device is another alternative to avoid HA occlusion. 14-17 However, placement of the side branch of the endograft in the HA cannot be performed in the setting of tortuous anatomy, thin lumen (common iliac artery lumen < 18 mm in diameter), or short common iliac arteries (< 40 mm in length) and HA aneurysm. Anatomic suitability for the iliac branched device is disappointing, with only 35% to 58% of AIAs appropriate for this device. 18-20 Patients deemed unfit for surgical or standard endovascular management are subject to unfavorable outcomes according to their aneurysm type and size. Thoracic endovascular aortic repair has gained acceptance as a valid treatment option for thoracic aortic aneurysms. Despite great technical and device improve- 82 ENDOVASCULAR TODAY MARCH 2016 VOL. 15, NO. 3

TABLE 1. AUTHORS PATIENT SELECTION CRITERIA FOR THE SANDWICH TECHNIQUE TAAA repair AIA repair FIT Unfit for open surgery Urgent setting (rupture, rapid growth, aneurysm size 70 mm) Type B aortic dissection with narrow true lumen Very tortuous TAAA at visceral level No bilateral distal CIA landing zone No unilateral distal CIA landing zone plus contralateral HAA or contralateral HA with previous occlusion/severe stenosis AAA with bilateral, short, healthy CIA (no bilateral distal landing zone) UNFIT Previous bilateral LIMA bypass Previous aortic arch debranching Bilateral subclavian artery occlusion Type III aortic arch Descending TAA with no proximal neck Visceral arteries < 4 mm in diameter HA < 4 mm in diameter Poor HA runoff Severe HA ostial stenosis (> 80%) Abbreviations: AAA, abdominal aortic aneurysm; AIA, aortoiliac aneurysm; CIA, common iliac artery; HA, hypogastric artery; HAA, hypogastric artery aneurysm; LIMA, left internal mammary artery; TAA, thoracic aortic aneurysm; TAAA, thoracoabdominal aortic aneurysm. ment in the last 2 decades, complex aortic aneurysm disease, such as thoracoabdominal aortic aneurysms (TAAAs), still presents technical challenges that are not completely overcome by either open surgery or currently available endovascular techniques. A review of the literature demonstrates elevated morbidity and mortality rates associated with open surgery 21 and/or hybrid procedures, 22,23 as well as highlights the high incidence of spinal cord ischemia and the considerable reintervention rates with multibranched thoracoabdominal stent grafts. 24,25 Lastly, the time necessary for producing a custom multibranched thoracoabdominal stent graft precludes the use of these techniques in the urgent or emergent settings. The sandwich technique was first introduced in 2008 to treat AIAs extending to the HA and has rapidly improved to address all four types of complex aortic aneurysms. 18,26-28 The concept of this technique was based on the trihedron feasibility, immediate availability, and cost-effectiveness. The sandwich technique was primarily developed to overcome anatomical and device constraints that limited the endovascular approach in either elective or urgent settings. Over 7 years, the sandwich technique has proved safe, long-lasting, and unparalleled with regard to low rates of spinal cord ischemia, use in the urgent or emergent settings for TAAA endovascular repair, and flexibility to allow the surgeon to use any available stent graft. In this article, we provide patient selection criteria for the sandwich technique for TAAA and AIA repair (Table 1), as well as propose tips and tricks to optimize the interventionist s experience to ultimately improve results and the degree of user-friendliness. We believe these tips will help minimize confounding aspects that might make the procedure challenging. The following tips and tricks were derived from our own single-center experience and have helped us improve user-friendliness and duration of sandwich procedures for both AIA and TAAA repair. Over the years, we have found that choosing the right access, appropriate devices, and performing the procedure in a stepwise manner is paramount. TIPS AND TRICKS FOR AIA REPAIR Access Selection The percutaneous left brachial artery approach (90-cm-long, 7-F sheath) is the preferred access for HA cannulation and should be combined with bilateral femoral artery approach to allow for all necessary steps. Femoral accesses can be open or percutaneous based on the surgeon s preferred access type. We usually opt for open access on one side to make it easy to deliver the endoprosthesis and percutaneous on the other for contralateral iliac limb insertion and/or angiographic purposes. Procedural Logistics The procedure includes the following four steps to be undertaken in the order listed. Shuffling the steps might make the procedure cumbersome. VOL. 15, NO. 3 MARCH 2016 ENDOVASCULAR TODAY 83

E VA R A B C D E F Figure 1. Stepwise approach to AIA repair. Insert the main body of the bifurcated stent graft through a femoral approach and leave the distal end of the ipsilateral iliac limb 10 to 20 mm above the HA origin (A). Cannulate the ipsilateral HA through a left brachial access (B). Place the distal end of a SECS inside the HA at least 2 cm and position the iliac limb extension 10 mm below the proximal end of the SECS to overlap at least 5 cm (C). Deploy the iliac limb extension and model it using a latex balloon (D). Deploy the SECS, followed by a bare self-expandable stent inside (E). Deployment of the contralateral iliac limb (F). Figures 1A and 1C F reprinted from Lobato AC, Camacho-Lobato L. Endovascular treatment of complex aortic aneurysms using the sandwich technique. J Endovasc Ther. 2012;19:691 706. Reprinted with permission of SAGE Publications, Inc. Step 1. Insert the main body of any commercially available bifurcated stent graft through a femoral approach, leaving the distal end of the ipsilateral iliac limb 10 to 20 mm above the HA origin (Figure 1A). tip curves at least 125-cm long, running inside a 90-cmlong, 7-F sheath. After cannulation, exchange the stiff hydrophilic guidewire for an extra-stiff, 0.035-inch guidewire with a floppy tip no longer than 2 cm (Figure 1B). Step 2. Address the HA. Cannulate the ipsilateral HA preferentially through a left brachial access. HA cannulation is performed using a stiff, 0.035-inch hydrophilic guidewire and 5-F catheters with vertebral, multipurpose Step 3. Place the distal end of a self-expanding covered stent (SECS) inside the HA at least 2 cm, and position the iliac limb extension 10 mm below the proximal end of the SECS to overlap at least 5 cm (Figure 1C). The suggested 84 ENDOVASCULAR TODAY MARCH 2016 VOL. 15, NO. 3

A B C D E F Figure 2. Stepwise approach to TAAA repair. Insert the thoracic aortic stent graft through a femoral approach and deploy it on the full thoracic extension of the aneurysm, with the distal end 10 mm to 20 mm above the celiac axis (A). Cannulate the visceral arteries a 0.035-inch stiff hydrophilic guidewire and 5-F catheters with vertebral, multipurpose tip curves at least 125-cm long (B). Treat the remaining segment of the aneurysm depending on the type of TAAA. In this case, a bifurcated stent graft is deployed followed by the insertion of SECS into the visceral arteries (C). A thoracic stent graft is then positioned to treat the remaining segment of the aneurysm (D). Deploy the aortic stent graft below the proximal end of the SECS, followed by the aortic stent graft with a latex balloon (E). Deploy the SECS followed by a bare self-expandable stent (F). Figure 2A reprinted from Lobato AC, Camacho-Lobato L. Endovascular treatment of complex aortic aneurysms using the sandwich technique. J Endovasc Ther. 2012;19:691 706. Reprinted with permission of SAGE Publications, Inc. diameter of the iliac limb extension should be 2 mm larger than the external iliac artery lumen, and the length should allow for the iliac extension to be positioned at least 3 cm inside the external iliac artery. Deploy the iliac limb extension and model it using a latex balloon (Figure 1D). Step 4. Deploy the SECS (the suggested diameter is 1 mm larger than the HA lumen, and the suggested length is 10 cm), followed by a bare self-expandable stent inside the SECS (the same diameter and length as the SECS) to avoid kinking and future occlusion (Figure 1E). SECS dilatation with an angioplasty balloon is performed only when lumen compression is greater than 50%. For bilateral CIAAs extending to both HAs, deploy the contralateral iliac limb and repeat steps 2 through 4 (Figure 1F). VOL. 15, NO. 3 MARCH 2016 ENDOVASCULAR TODAY 85

TIPS AND TRICKS FOR TAAA REPAIR Access Selection The access selection and destination for TAAA repair depends on the number of vessels undergoing revascularization. Four-vessel revascularization. Left open subclavian artery access is the preferred access and should be made available with a 28-cm-long, 20-F sheath and two 90-cm-long, 7- and 8-F sheaths placed inside it to allow for two-vessel cannulation (one visceral artery and one renal artery). In addition, proceed with the percutaneous right brachial artery approach using a 90-cm-long, 8-F sheath to cannulate another visceral artery via a percutaneous contralateral retrograde femoral artery approach. Femoral access can be open or percutaneous based on the surgeon s discretion. We usually opt for open access on one side to make it easy to deliver the endoprosthesis and for percutaneous on the other to cannulate one of the renal arteries with a 65-cm-long, 7-F sheath. Three-vessel revascularization. The approach for three-vessel revascularization uses the same accesses previously described for four-vessel revascularization, but one femoral approach (11-cm-long, 5-F sheath) should be used for angiographic purposes only. Two-vessel revascularization. Spare the right brachial artery access, and save one femoral approach for angiographic purposes only as previously mentioned. Procedural Logistics The procedure for TAAA repair includes the following four steps to be undertaken in the order listed. Shuffling the steps may make the procedure cumbersome. Suggested overlapping measures and changes in device length may increase the risk for endoleak or occlusion. Step 1. Address the thoracic part of the aneurysm. Insert the thoracic aortic stent graft through a femoral approach and deploy it on the full thoracic extension of the aneurysm, leaving its distal end 10 mm to 20 mm above the celiac axis (Figure 2A). Step 2. Treat the visceral arteries. Cannulate the visceral arteries using a stiff 0.035-inch hydrophilic guidewire and 5-F catheters with vertebral, multipurpose tip curves at least 125-cm long. After cannulation, the stiff hydrophilic guidewire is exchanged for an extra-stiff, 0.035-inch guidewire with a floppy tip no longer than 20 mm, and then position the introducer 20 mm inside the target visceral vessel (Figure 2B). Step 3. Treat the remaining segment of the aneurysm. For type I TAAAs, insert the thoracic stent graft through the femoral access site. For types II, III, and IV TAAA, a bifurcated stent graft is deployed followed by the insertion of SECS into the visceral arteries (Figure 2C). A thoracic stent graft is then positioned to treat the remaining segment of the aneurysm (Figure 2D). The aortic stent graft should be deployed 1 cm below the proximal end of the SECS to obtain at least a 5 cm overlapping (between the thoracic endoprostheses and SECS), followed by aortic stent graft accommodation with a latex balloon (Figure 2E). Step 4. Deploy the SECS (the suggested diameter is 1 mm larger than the target visceral vessel lumen), followed by a bare self-expandable stent inside them (same diameter and length of the SECS) to avoid kinking and future occlusion (Figure 2F). The suggested lengths of the SECS are 10 cm for celiac trunk and superior mesenteric artery, 15 cm for antegrade renal arteries revascularization, and 5 cm for retrograde renal artery revascularization. Dilatation of the SECS with an angioplasty balloon is performed only when lumen compression is greater than 50%. The distal stent graft must be larger than the proximal stent graft. A 30% oversizing of the sandwich stent graft is recommended to enable two- to four-vessel endo revascularization. SUMMARY AIAs extending to the HA may require a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent graft limb(s), a potential site for endoleak. Thoracic endovascular aortic repair has gained acceptance as a valid treatment option for thoracic aortic aneurysms. Despite great technical and device improvement in the last 2 decades, complex aortic aneurysm disease, such as TAAA, still presents technical challenges that are not completely overcome by either open surgery or currently available endovascular techniques. The sandwich technique was first introduced in 2008 to treat AIAs extending to the HA and has rapidly improved to address all four types of complex aortic aneurysms. The concept behind this technique was based on the trihedron feasibility, immediate availability, and cost-effectiveness. The sandwich technique was primarily developed to 86 ENDOVASCULAR TODAY MARCH 2016 VOL. 15, NO. 3

overcome anatomic and device constraints that limited the endovascular approach in either elective or urgent settings. Over 7 years, the sandwich technique has proven safe, long-lasting, and, in our opinion, unparalleled with regard to low rates of spinal cord ischemia, use in the urgent or emergent settings for TAAA endovascular repair, and flexibility to allow the surgeon to use any available stent graft. In this article, we have provided our perspectives on patient selection criteria for the sandwich technique for TAAA and AIA repair, as well as proposed tips and tricks to optimize the interventionist s experience to ultimately improve results and the degree of user-friendliness. n 1. Armon MP, Wenham PW, Whitaker SC, et al. Common iliac artery aneurysms in patients with abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 1998;15:255-257. 2. Razavi MK, DeGroot M, Olcott C 3rd, et al. Internal iliac artery embolization in stent graft treatment of aortoiliac aneurysms: analysis of outcomes and complications. J Vasc Interv Radiol. 2000;11:561-566. 3. Karch LA, Hodgson KJ, Mattos MA, et al. Adverse consequences of internal iliac artery occlusion during endovascular repair of abdominal aortic aneurysms. J Vasc Surg. 2000;32:676-683. 4. Yano OJ, Morrissey N, Eisen L, et al. Intentional internal iliac artery occlusion to facilitate endovascular repair of aortoiliac aneurysms. J Vasc Surg. 2001;34:204-211. 5. Parodi JC, Ferreira M. Relocation of the iliac artery bifurcation to facilitate endoluminal treatment of abdominal aortic aneurysms. J Endovasc Surg. 1999;6:342-347. 6. Faries PL, Morrissey N, Burks JA, et al. Internal iliac artery revascularization as an adjunct to endovascular repair of aortoiliac aneurysms. J Vasc Surg. 2001;34:892-899. 7. Mertens RA, Bergoeing MP, Mariné LA, et al. Antegrade hypogastric revascularization during endovascular aortoiliac aneurysm repair: an alternative to bilateral embolization. Ann Vasc Surg. 2010;24:255. e9-12. 8. Bergamini RM, Rachel ES, Kinney EV, et al. External iliac artery-to-internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting. J Vasc Surg. 2002;35:120-124. 9. Criado FJ, Wilson EP, Velazquez OC, et al. Safety of coil embolization of the internal iliac artery in endovascular grafting of abdominal aortic aneurysms. J Vasc Surg. 2000;32:684-688. 10. Gough MJ, MacMahon MJ. A minimally invasive technique allowing ligation of the internal iliac artery during endovascular repair of aortic aneurysms with an aortouniiliac device. Eur J Vasc Endovasc Surg. 1998;16:535-536. 11. Karch LA, Hodgson KJ, Mattos MA, et al. Management of ectatic, nonaneurysmal iliac arteries during endoluminal aortic aneurysm repair. J Vasc Surg. 2001;33:S33-8. 12. Torsello G, Schonefeld E, Osada N, et al. Endovascular treatment of common iliac artery aneurysms using the bell-bottom technique: long-term results. J Endovasc Ther. 2010;17:504-509. 13. Lobato AC, Camacho-Lobato L, Cury MP. Endovascular repair of aortoiliac aneurysms: concurrent comparison between hypogastric artery interruption, bell-bottom, and sandwich techniques J Vasc Surg. 2014;59:19S-20S. 14. Greenberg RK, West K, Pfaff K, et al. Beyond the aortic bifurcation: branched endovascular grafts for thoracoabdominal and aortoiliac aneurysms. J Vasc Surg. 2006;43:879-887. 15. Malina M, Dirven M, Sonesson B, et al. Feasibility of a branched stent-graft in common iliac artery aneurysms. J Endovasc Ther. 2006;13:496-500. 16. Verzini F, Parlani G, Romano L, et al. Endovascular treatment of iliac aneurysm: concurrent comparison of side branch endograft versus hypogastric exclusion. J Vasc Surg. 2009;49:1154-1161. 17. Pua U, Tan K, Rubin BB, et al. Iliac branch graft in the treatment of complex aortoiliac aneurysms: early results from a North American institution. J Vasc Interv Radiol. 2011;22:542-549. 18. Lobato AC, Camacho-Lobato L. Endovascular treatment of complex aortic aneurysms using the sandwich technique. J Endovasc Ther. 2012;19:691-706. 19. Pearce BJ, Varu VN, Glocker R, et al. Anatomic suitability of aortoiliac aneurysms for next generation branched systems. Ann Vasc Surg. 2015;29:69-75. 20. Gray D, Shahverdyan R, Jakobs C, Brunkwall J, Gawenda M. Endovascular aneurysm repair of aortoiliac aneurysms with an iliac side-branched stent graft: studying the morphological applicability of the Cook device Eur J Vasc Endovasc Surg. 2015;49:283-288. 21. Wong DR, Parenti JL, Green SY, et al. Open repair of thoracoabdominal aortic aneurysm in the modern surgical era: contemporary outcomes in 509 patients. J Am Coll Surg. 2011;212:569-581. 22. Chiesa R, Tshomba Y, Melissano G, Logaldo D. Is hybrid procedure the best treatment option for thoraco-abdominal aortic aneurysm? Eur J Vasc Endovasc Surg. 2009;38:26-34. 23. Patel R, Conrad MF, Paruchuri V, et al. Thoracoabdominal aneurysm repair: hybrid versus open repair J Vasc Surg. 2009;50:15-22. 24. Verhoeven EL, Katsargyris A, Bekkema F, et al. Editor s choice ten-year experience with endovascular repair of thoracoabdominal aortic aneurysms: results from 166 consecutive patients. Eur J Vasc Endovasc Surg. 2015;49:524-531. 25. Sobel JD, Vartanian SM, Gasper WJ, et al. Lower extremity weakness after endovascular aneurysm repair with multibranched thoracoabdominal stent grafts. J Vasc Surg. 2015;61:623-628. 26. Lobato AC. Sandwich technique for aortoiliac aneurysms extending to the internal iliac artery or isolated common/internal iliac artery aneurysms: a new endovascular approach to preserve pelvic circulation. J Endovasc Ther. 2011;18:106-111. 27. Lobato AC, Camacho-Lobato L. A new technique to enhance endovascular thoracoabdominal aortic aneurysm therapy: the sandwich procedure. Semin Vasc Surg. 2012;25:153-160. 28. Lobato AC, Camacho-Lobato L. The sandwich technique to treat complex aortoiliac or isolated iliac aneurysms: results of midterm follow-up. J Vasc Surg. 2013;57:23-34. Armando C. Lobato, MD, PhD Director, São Paulo Vascular & Endovascular Institute (ICVE-SP) Professor, Translational Medicine Research Program Federal University of São Paulo (UNIFESP-EPM) aclobato@icve.com.br Luciana Camacho-Lobato, MD, PhD Internal Medicine, São Paulo Vascular & Endovascular Institute (ICVE-SP) Adjunct Professor, Department of Medicine Federal University of São Paulo (UNIFESP-EPM) Marcelo Cury, MD São Paulo Vascular & Endovascular Institute (ICVE-SP) Research Fellow, Federal University of São Paulo (UNIFESP-EPM) Camila Kolber, MD São Paulo Vascular & Endovascular Institute (ICVE-SP) Jose Reginaldo Simão, MD São Paulo Vascular & Endovascular Institute (ICVE-SP) 88 ENDOVASCULAR TODAY MARCH 2016 VOL. 15, NO. 3