Newborn Hearing Thresholds Measured by Both Insert and Earphone Methods

Similar documents
Thresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

Application of a Stimulus Spectral Calibration Routine to Click Evoked Otoacoustic Emissions

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

ORIGINAL ARTICLE. Chung-Yi Lee, 1,2 Fu-Shan Jaw, 1 Shin-Liang Pan, 3,4 Tai-Hsin Hsieh, 2 Chuan-Jen Hsu 2 *

KANSAS GUIDELINES FOR INFANT AUDIOLOGIC ASSESSMENT

Hearing Screening, Diagnostics and Intervention

The CON-SOT-LOT Test for Nonorganic Hearing Loss

James W. Hall III, Ph.D.

Clinical Forum. Detecting and Remediating External Meatal Collapse during Audiologic Assessment. Levi A. Reiter* Shlomo Silmant

Effects of Exam Procedures on Transient Evoked Otoacoustic Emissions (TEOAEs) in Neonates

Comparison of Acoustic Immittance Measures Obtained With Different Commercial Instruments

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

Comparison of Screening Otoacoustic Emission Devices for Pre-school Aged Children

Ear Exam and Hearing Tests

Paediatric Whitepaper

Effects of Stimulus Phase on the Latency of the Auditory Brainstem Response

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

Early Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners

The Level Specific CE-Chirp

Hearing Evaluation: Diagnostic Approach

Update on Frequency Specificity of AEP Measurements

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

Neuro-Audio Version 2010

Supplementary Online Content

Basic Principles. The Current State of Auditory Steady-State Responses

NIH Public Access Author Manuscript Ear Hear. Author manuscript; available in PMC 2008 June 27.

Audiological Diagnosis after Newborn Screening

Provisional guidelines for using Auditory Steady State Responses (ASSR) in babies. July 2009

The clinical Link. Distortion Product Otoacoustic Emission

MEASUREMENTS AND EQUIPMENT FOR AUDIOLOGICAL EVALUATIONS

SLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

Effect of intensity increment on P300 amplitude

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Chapter 4 : Newborn Screening

5. Hospitals will provide the family with a copy of the Michigans Community Program: Information for Parents (MDCH /01). Copies can be ordered,

BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.

AUTOMATED AUDITORY BRAINSTEM RESPONSE INFORMATION AND GUIDELINES FOR SCREENING HEARING IN BABIES

Evoked Potenital Reading Session: BAEPs

Audiometric Techniques Program in Audiology and Communication Sciences Pediatric Audiology Specialization

ORIGINAL ARTICLE. Auditory Sensitivity in Children Using the Auditory Steady-State Response

EHDI: An Amazing Journey

Evoked Potenital Reading Session: BAEPs

Acoustic-Immittance Characteristics of Children with Middle-ear Effusion : Longitudinal Investigation

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

Knowledge Sharing: Pediatric Amplification Tips and Tricks. Implementing Best Practice

영유아에서청성뇌간반응과청성지속반응의역치비교

The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss

Maximum Length Sequence Auditory Evoked Brainstem Responses in Human Newborns and Adults

Articles. Automated and Conventional AB R Screening Uchniques in High-Risk Infants. Abstract. John T. Jacobson* Claire A. Jacobsont Robert C.

Development of Low-Frequency Tone Burst versus the Click Auditory Brainstem Response

Implementing the Cross-Check Principle in Pediatric Audiology

PURPOSE OF THIS PRESENTATION GUIDELINES DEVELOPMENT CONFERENCE GUIDELINES DEVELOPMENT CONFERENCE: FACULTY GUIDELINES DEVELOPMENT CONFERENCE: OUTCOMES

Recommended Procedure Cochlear Microphonic Testing

General about Calibration and Service on Audiometers and Impedance Instruments

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

VALIDITY OF DIAGNOSTIC COMPUTER-BASED AIR AND FOREHEAD BONE CONDUCTION AUDIOMETRY

A Guide to. Otoacoustic Emissions (OAEs) for Physicians.

Editorial Hearing Aids and the Brain

CASE REPORT. AUDITORY NEUROPATHY WITH BILATERAL BAT EARS A RARE CASE REPORT A. Sivakumar 1, V. Narendrakumar 2

The following describes general use of ELIOS device

Establishing Normal Hearing with the Dichotic Multiple-frequency Auditory Steady-State Response Compared to an Auditory Brainstem Response Protocol

FUNCTIONAL HEARING SCREENING WHO WE ARE: YOU TELL ME OBJECTIVES: SLIGHT HIGH FREQUENCY HEARING LOSS OUTLINE: A PASS IS NOT A PASS FOR LIFE!

Universal Newborn Hearing Screenings: A Three-Year Experience

Newborn Screening Free health checks for your baby. Newborn. Hearing Screening. Referral to Audiologist

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

Otoacoustic Emissions as a Cross-Check in Pediatric Hearing Assessment : Case Report

Historical Perspective. JCIH 1973 Position Statement. JCIH Goals. JCIH 1982 Position Statement

Your Baby s Visit to the Audiology Clinic (Hearing Clinic)

C ritical Review: Do we see auditory system acclimatization with hearing instrument use, using electrophysiological measures?

Hearing loss can muddy the waters of otologic disease detection

Quick Guide - eabr with Eclipse

UNDERSTANDING HEARING LOSS

UNDERSTANDING HEARING LOSS

DSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015.

Clinical Comparison of the Auditory Steady-State Response with the Click Auditory Brainstem Response in Infants

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Auditory Steady-State Responses and Speech Feature Discrimination in Infants DOI: /jaaa

C urrent proposals for the identification

Hearing Conservation Program

A Guide to. Otoacoustic Emissions (OAEs) for Otolaryngologists.

Hearing Loss, Deaf Culture and ASL Interpreters By Laura Jacobsen (4/2014)

EDUCATION University of Texas at Dallas-Dallas, Texas Doctor of Philosophy-Audiology ( )

III. Comprehensive. Efficient. Auditory EP Testing

Evaluating ME Function via an Acoustic Power Assessment

C HAPTER FOUR. Audiometric Configurations in Children. Andrea L. Pittman. Introduction. Methods

Strategies Used in Feigning Hearing Loss

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

Incorporating CAEP Testing in the Pediatric Clinic. Sarah Coulthurst, M.S. Alison J. Nachman, AuD Pediatric Audiologists

Session 2: Sensory Development

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Study of brainstem evoked response audiometry in sensorineural hearing deafness- A hospital based study

Update on Bone-Conduction Auditory Brainstem Responses: A Review

mously with greater accuracy for mid and high frequencies, compared to the accuracy that is achieved at lower frequencies.

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

A Case Study of Progressive Auditory Neuropathy

Audiology 101 SOFT HIGH PITCH LOUD. How do we hear? Ear to the Brain. Main parts of the Ear

CHILDREN WITH CMV: DON T FORGET THE IMPORTANCE OF EARLY INTERVENTION. Paula Pittman, PhD Director, Utah Parent Infant Program for the Deaf

Transcription:

J Am Acad Audiol 5 : 141-145 (1994) Newborn Hearing Thresholds Measured by Both Insert and Earphone Methods Robert Galambos* t MaryJo Wilson* Abstract Auditory brainstem response (ABR) absolute thresholds were obtained from 31 ears of 28 newborns using both the insert and the earphone methods to deliver the stimuli. The two estimates on each ear were acquired in a single test session, and they differed by 10 db or less in all cases. The results suggest that when the earphone is used, it rarely if ever collapses the ear canal to cause an artificial conductive hearing loss. Key Words : Absolute threshold, auditory brainstem response (ABR), insert earphone, intensive care nursery (ICN), newborn or the past 15 years, one of us (MW) has been obtaining auditory brainstem responses (ABRs) from babies about to be F discharged from second and third level intensive care nurseries (ICNs) in San Diego. Year after year, close to 20 percent of the third level ICN babies have failed to respond to 30-dB clicks in one or both ears, and the comparable percentage for the second level infants has been about half this (Galambos, Hicks, and Wilson, 1982, 1984, Galambos, 1986 ; Galambos, Wilson, and Silva, in press). It is sometimes said that such high failure rates are due to the fact that the earphone delivering the stimulus collapses the ear canal and creates an artificial conductive hearing loss. If this explanation is correct, the hearing losses we have been reporting include an artifact of unknown magnitude, on the one hand, and, on the other, our testing staff consistently produces the artifact about twice as often when they test third level babies. After a literature search failed to uncover useful information about infant canal collapse in general and our concerns in particular, we decided to investigate the matter ourselves. "Children's Hospital and Speech, Hearing and Neurosensory Center, San Diego, California ; and tdepartment of Neurosciences, University of California San Diego, La Jolla, California Reprint requests : Robert Galambos, 8826 La Jolla Scenic Drive, La Jolla, CA 92037 In the study to be described here, we obtained two ABR thresholds from each ear, one by the conventional earphone method and the other by the insert procedure in which the stimulus is conducted from a distant transducer into the ear canal through a plastic tube. If the earphone produces an artificial conductive hearing loss, the two threshold estimates will disagree. We report and discuss the outcome of these measurements here. Subjects METHOD ABRs were obtained from 28 infants about to be discharged from the Children's Hospital third level ICN and the Sharp Memorial Hospital and Grossmont Hospital second level ICNs (in Table 1 these are identified as N, T, and C, respectively). As part of the discharge procedure, the babies had been scheduled for the routine diagnostic ABR, which, in these hospitals, establishes whether each ear responds to 30-dB nhl clicks, and, if it does not, requires increasing the stimulus level until the threshold is reached. The insert measurement, which some clinics obtain routinely, was added to our earphone procedures to discover whether it produces lower and/or more reliable threshold estimates. The comparisons were made between August 1992 and March 1993 during sessions lasting about 1 hour. Babies

Journal of the American Academy of Audiology/Volume 5, Number 2, March 1994 Table 1 SubjectData" Threshold Estimations by Subject and Method ABR Absolute Threshold (db) By Phone By Insert Difference 32 MLT 40 35 5 32 FLN 15 5 10 33 FRN 20 10 10 33 - LCf 50 45 5 33 - RCf 50 50 0 33 FRN 20 10 10 34 FLN 10 10 0 34 - LN 15 5 10 34 - LN 10 10 0 34 FLN 25 15 10 34 FRN 20 10 10 34 --N 5 5 0 35 - LN 20 10 10 35 - LN 15 15 0 35 - LN 35 30 5 36 MRT 30 25 5 36 MRT 30 30 0 37 FLT 30 30 0 39 --N 15 15 0 39 MRN 15 15 0 39 - RT 35 25 10 40 MLN 15 5 10 40 MLN 35 30 5 40 - LT 35 35 0 41 MRN 20 10 10 43 FLT f 35 35 0 43 FRTt 50 50 0 - -LNt 25 25 0 - -RNt 20 10 10 - - LN 50 40 10 - MRT 40 40 0 N = Nicolet CA1000 ; T = Tracor Nomad 3400 ; C = Cadwell 5200 ; -= data unavailable. `Initial numbers give conceptual age in weeks, followed by sex (M, F), ear (L, R), and ABR instrument used. (Same baby. who received the added insert test were not selected randomly from the group of infants (about 300) tested during this period ; the ones with hearing loss by earphone were chosen whenever possible. Procedure The ABR testing method, already described in detail (Galambos et a1,1982,1984 ; Galambos, 1986), uses a commercial device to generate the stimuli, amplify the EEG, average the ABRs, and write out the result. We used three different instruments (Nicolet CA1000 ; Cadwell 5200 ; Tracor Nomad 3400), with either a TDH 39 earphone or the Tracor Northern TM-3430-22 insert system connected to the earphone outlet. We aimed to replicate all ABRs and estimate each threshold to ±5 db by both methods, but time often ran out before this could be accomplished. In all cases, the earphone delivering the click stimuli was hand held. Calibrations Each test instrument uses a 0 db nhl reference established by a jury of normal-hearing adults. However, note that factory-supplied calibration measurements and ICN clinical measurements are made under different conditions, especially ambient noise. Furthermore, infants were tested in the ICN while asleep in an open crib, or inside an isolette, or while held in the mother's arms. Such uncontrolled variations in both test conditions and ambient noise level would not be tolerated in an audiology laboratory but are inevitable in the clinical setting. Despite the response variances they introduced, the superimposed ABR replications in Figure 1 suggest that measurement error was limited to 5 or 10 db most of the time. S RESULTS ince 1977, the "normal" newborn ear has been defined in our clinic as one that delivers an ABR response to a 30-dB nhl click delivered through an earphone. This definition arose out of a study that reported that 99.8 percent of 220 babies (386 ears) delivered ABRs to 30-dB clicks under an earphone, and that 47 of 50 of them also responded at 20 db nhl but not at 10 db (Schulman- Galambos and Galambos, 1979). The final decision to use the 30-dB suprathreshold definition instead of an absolute threshold definition was made for practical reasons : to establish the presence of a 10- or 15-dB suprathreshold response requires far less time and effort in a clinical environment, and most clinicians consider this justsuprathreshold response to be a satisfactory substitute for the nearby absolute threshold. Twenty of the 31 ears in the study were normal by this definition. Figure 1 shows the absolute threshold estimates for two of these normal ears. Each panel displays two latency-intensity series, the one on the left made in the conventional way by holding an earphone over the pinna, the one on the right by stimuli delivered into the ear canal from the distant transducer through a plastic tube terminated in a small silicone nipple. At the bottom of each panel, the two 60-dB ABRs 142

Newborn Hearing Thresholds/Galambos and Wilson DB nhl DB RFIL OVERLAP INSERT AND EARPHONE RESPONSES INSERT 60 d8 OVERLAP INSERT AND EARPHONE RESPONSES INSERT EARPHONE Figure 1 ABR latency-intensity series obtained from newborns aged 39 weeks (left panel) and 34 weeks (right panel) by both the earphone and the insert methods. Numbers on the traces give ABR latencies. The two 60-dB recordings in each panel are superimposed at the bottom. Both methods evoke similar physiological events at all intensity levels and agree on the intensity of the absolute threshold stimulus. are superimposed ; their similarities in morphology and latencies (each insert record has been moved to the left by 0.7 msec, the added latency introduced into the sound path by the plastic tube) indicate that the two stimulus systems delivered essentially the same nominally 60-dB level click to the eardrum. The absolute threshold estimates reached by the two methods also agree ; both place this at 15 db for the 39-week-old baby, and at 10 or possibly 5 db for the 34-week-old baby. Thus, the two methods evoked closely similar physiological responses at the highest and lowest intensities used, and the likelihood that the earphone had collapsed the ear canals can be ruled out. The measurements in Figure 1 confirm what our earlier paper reported, namely, an absolute threshold estimate made under an earphone in the ICN environment can be close to what one might expect to obtain from an adult ear inside a sound-treated audiologic testing booth. The figure also shows, somewhat surprisingly, that the insert method had no measurable advantage over the earphone procedure at the lowest signal levels at which infant ears respond. Table 1 assembles all the available data on the 31 ears tested. Figure 2 is a condensed version of Table 1 ; in it, each insert-earphone difference listed in Table 1 is entered by its amount and the threshold level at which the difference was established. Thus, the two ears of Figure 1 are entered in the upper left corner of Figure 2, where they join four other ears with absolute thresholds between 5 and 20 db nhl and identical insert and earphone estimates ; the bottom entry in the 5-20 column shows that for nine other low-threshold ears the insert estimate was 10 db better than the earphone estimate. The column headed 25-35 contains the critical 30 db nhl stimulus intensity that for some audiologists is a screening pass-fail criterion and for others the suprathreshold index of a normal-hearing threshold. An interesting statistic to be extracted is the number of times the earphone and insert methods agree that a given baby's absolute threshold estimate places him/ her below, at, or above the critical 30-dB level. If the 10 ears that can answer this question are Absolute Threshold Range (db) 5-20 25-35 40-50 n 0 6 5 3 14 5 0 3 2 5 10 9 2 1 12 15 10 6 31 Figure 2 Threshold differences from Table 1 condensed.

Journal of the American Academy of Audiology/Volume 5, Number 2, March 1994 identified in Table 1, it will be found that the two methods agree at the 25-, 30-, or 35-dB level in all but three instances ; in these three cases, the earphone estimate was always 35 db compared to insert estimates of either 30 db (two cases) or 25 db. Thus, 3 ears with thresholds close to the borderline-normal 30 db by the insert method would have failed with a hearing loss of 5 db by the earphone method. The entries in the 40-50 column show six ears with elevated threshold by the insert method ; the earphone estimate either agreed with the insert estimate (three ears) or was higher by 5 db (two ears) or 10 db (one ear). DISCUSSION Collapsed Ear Canals? There are three possible reasons for the 5- and 10-dB threshold differences in Figure 2. First, during routine testing of ICN infants, an occasional difference of this magnitude in successive threshold estimates by any method would not be considered unusual. However, the random measurement-error explanation is inconsistent with the fact that the insert estimate is always smaller than the corresponding earphone estimate when not equal to it. Among the possible reasons for this asymmetric result are these : an imperfect seal where the earphone meets the pinna, which from time to time allows signal energy to escape and masking noise to enter ; and signal attenuation, because the earphone collapses the ear canal and causes an artificial conductive hearing loss. The imperfect seal explanation is consistent with the fact that by far the largest number of insert-earphone differences appear at the lowest threshold intensities, which is where the effects of such leakage artifacts would be noticed most often. Unfortunately, there is no certain way to decide whether a given insert-earphone difference in Table 1 is due to measurement error, an imperfect seal, or canal collapse. If one assumes canal collapse caused every one of the differences, the loss produced is no more than 5 db in 61 percent of the measurements and never more than 10 db in any of them. At the signal level of greatest interest, 30 db nhl, canal collapse would produce differences of 5 db (two cases) or 10 db (once) and change the classification of three babies. As for the claim noted at the beginning of this paper-namely, that canal collapse is responsible for the high prevalence of hearing loss in newborn populations tested under an earphone-table 1 contains 11 ears with threshold elevations between 35 and 50 db by both insert and earphone ; obviously, none of these hearing losses could possibly have been caused by collapsed canals. Finally, nothing in the data helps explain the fact that thresholds of second level babies are elevated half as often as those of third level babies. It would appear, then, that even after the hypothetical worst cases are included in the count, our measurements provide little support for a claim that clinics like ours report large numbers of ICN babies with elevated ABR thresholds because our earphones collapse ear canals (e.g., Hall et al, 1988 ; Schwartz and Schwartz, 1991). Opposing Database The collapsed canal idea was introduced into the literature on the basis of earphone ABRs recorded 3 months apart from a single infant and anecdotal accounts (i.e., no data) involving two additional infants and one adult (Hosford-Dunn, Runge, Hillel, and Johnson, 1983). The only other published evidence known to us comes from two studies by Gorga, Reiland, Beauchaine, Worthington, and Jesteadt (1987) and Gorga, Kaminski, and Beauchaine (1988). The first of these reported a 16 percent failure rate at 30 db for a group of 699 ICN graduates tested by the earphone method, whereas a second study from the same ICN found thresholds elevated in "approximately 5%d" of 177 ears tested by the insert method. The authors state they believe the difference between their 16 percent and approximately 5 percent estimates is due to collapsed ear canals during the earphone measurements. However, in our limited sample, no more than 3 of the 11 earphone failures to respond at 30 db could possibly be due to collapsed ear canals. Resolving this disagreement will require more measurements in which both methods are used on the same ear in a single session. Substitute Inserts for Earphones in ICN Testing? This report shows that healthy ICN graduates can, in the ICN environment, produce ABRs to clicks as weak as 5 or 10 db nhl delivered through an earphone on the ear ; that the absolute threshold estimates made by the insert and earphone methods are often identical ; and that when these threshold estimates 144

Newborn Hearing Thresholds/Galambos and Wilson differ the insert estimate is always lower, but never by more than 10 db. Listed below are additional aspects of our comparison of the two methods that may be useful to those debating the use of earphones and inserts in newborn hearing testing. 1. The insert seems to be more invasive than the earphone. In our tests, some babies, seemingly annoyed by the tube in the ear, slept less soundly, moved more frequently, and prolonged the session by movement artifacts that required more response averaging. 2. Placing and fixing the insert tube in the ear canal and periodically examining and adjusting its position take more care, time, and effort than merely placing and adjusting an earphone. 3. If both ABR and otoacoustic emissions measurements are to be made on a given subject, using the insert method for both would be most efficient, because the emissions measurement requires the insert. 4. A direct comparison of the two methods on the same subjects will be instructive. In our program, where the goal is to obtain a threshold estimate for each ear, the disadvantages of the insert method clearly outweigh its single advantage, which is an estimate that averages about 5 db below that of the earphone approximately half the time. Because this small difference approximates the variability of test-retest measurements obtained with either method by itself, we have decided to continue using earphones, even though several authorities strongly advise against this (e.g., Schwartz and Schwartz, 1991 ; Hall, 1992). REFERENCES Galambos R. (1986). Identification of the newborn with hearing disorder using the auditory brainstem response (ABR). In : Cracco RQ, Bodis-Wollner I, eds. Evoked Potentials. New York : Alan R. Liss, 463-470. Galambos R, Hicks G, Wilson MJ. (1982). Hearing loss in graduates of a tertiary intensive care nursery. Ear Hear 3(2):87-90. Galambos R, Hicks GE, Wilson MJ. (1984). The auditory brain stem response reliably predicts hearing loss in graduates of a tertiary intensive care nursery. Ear Hear 5:254-260. Galambos R, Wilson MJ, Silva PD. (in press). Diagnosing hearing loss in the intensive care nursery : a twenty-year summary. JAm Acad Audiol. Gorga MP, Kaminski JR, Beauchaine KA. (1988). Auditory brain stem responses from graduates of an intensive care nursery using an insert earphone. Ear Hear 9:144-147. Gorga MP, Reiland JK, Beauchaine KA, Worthington DW, Jesteadt W. (1987). Auditory brainstem responses from graduates of an intensive care nursery : normal patterns of response. J Speech Hear Res 30 :311-318. Hall JW III. (1992). Handbook of Auditory Evoked Responses. Boston: Allyn and Bacon. Hall JW III, Kripal JP, Hepp T. (1988). Newborn hearing screening with auditory brainstem response: measurement problems and solutions. Semin Hear 9:15-33. Hosford-Dunn H, Runge CA, Hillel A, Johnson SJ. (1983). Auditory brainstem response testing in infants with collapsed ear canals. Ear Hear 4:258-260. Schulman-Galambos C, Galambos R. (1979). Brainstem evoked response audiometry in newborn hearing screening. Arch Otolaryngol 105 :86-90. Schwartz DM, Schwartz JA. (1991). Auditory evoked potentials in clinical pediatrics. In: Rintelmann WF, ed. Hearing Assessment. 2nd ed. Austin, TX : Pro-Ed, 4291176.