EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

Similar documents
IGRT/Adaptive Gating

Protura Robotic Patient Positioning System. for efficiency + performance

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

Unrivaled, End-to-End

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

Elekta Synergy Digital accelerator for advanced IGRT

Leksell Gamma Knife Icon A New User s Perspective

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

02 CyberKnife: Treatment Delivery

Cyberknife Stereotactic Treatment

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

SBRT REQUIRES: STEREOTACTIC BODY RADIOTHERAPY STEREOTACTIC BODY RADIOTHERAPY (SBRT) (SBRT) What s s in a name? Stereotactic Body Radiotherapy

Precisely Maximize Dose, side effects, Patient

Work partially supported by VisionRT


The High-End Solution for Real-Time Patient Tracking

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

XSIGHT LUNG TRACKING SYSTEM

ph fax

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Implementation of advanced RT Techniques

02 CyberKnife: System Overview

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

Original Date: April 2016 Page 1 of 7 FOR CMS (MEDICARE) MEMBERS ONLY

Inter-fractional Positioning Study for Breast Cancer with Proton Therapy using a 3D Surface Imaging System

CYBERKNIFE M6 SERIES: Unmatched Precision and Patient Comfort

Overview of Advanced Techniques in Radiation Therapy

A Patient s Guide to SRS

BRAINLAB ELEMENTS RADIOTHERAPY PLANNING

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

SRS Uncertainty: Linac and CyberKnife Uncertainties

IMAGE-GUIDED SPINE SURGERY

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

Elekta Infinity Digital accelerator for advanced treatments

Radiotherapy and Radiosurgery

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

Trilogy Stereotactic System Stereotactic, IMRT, and 3D CRT in one system

Elekta - a partner and world-leading supplier

What is the CyberKnife System?

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Universal Couchtop. for safe, efficient treatment planning + imaging. Long Extension. 1 Piece

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

SunCHECK Patient Comprehensive Patient QA

On the road to Gamma Knife Icon workflow automation in radiation oncology. Young Lee Department of Medical Physics

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

I. Equipments for external beam radiotherapy

1 : : Medical Physics, Città della Salute e della Scienza, Torino, Italy

Case Study. Institution Farrer Park Hospital

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

THE AIO SOLUTION ALL-IN-ONE PATIENT POSITIONING SYSTEM

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Universal Couchtop. for safe, efficient treatment planning + imaging. 5 Year Warranty. Long Extension. 1 Piece

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Estimation of patient setup uncertainty using BrainLAB Exatrac X-Ray 6D system in image-guided radiotherapy

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Performance Evaluation of Calypso (R) 4D Localization and Kilovoltage Image Guidance Systems for Interfraction Motion Management of Prostate Patients

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Objectives. Image-Guided RT: Process. kv CBCT Novel Clinical Applications and Future Directions. Standard Clinical Uses. Novel Applications.

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

) and the localizer(iso loc. I. Introduction

Managing the imaging dose during image-guided radiation therapy

brain SPINE 2 SRS Matures into breast lung spine LUNG Dr. Robert Timmerman Discusses SBRT for Inoperable Lung Cancer BRAIN

SRS Plan Quality and Treatment Efficiency: VMAT vs Dynamic Conformal ARCs

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Credentialing for the Use of IGRT in Clinical Trials

Has radiotherapy the potential being focal?

SEEING. BELIEVING. Dynamic Targeting IGRT A Leap in Cancer Treatment Accuracy

Medical Errors in Radiation Therapy 2014

CBCT of the patient in the treatment position has gained wider applications for setup verification during radiotherapy.

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

pat hways Medtech innovation briefing Published: 16 May 2018 nice.org.uk/guidance/mib147

Jean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division

vertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance

A N E W S T A N D A R D O F C A R E

Solutions

Stereotactic Radiosurgery

Introducing the TrueBeam STx system with Novalis Radiosurgery.

Subject: Image-Guided Radiation Therapy

Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6-degree couch

Integrating CBCT into Radiotherapy Verification Protocols

Advanced Tumor Treatment

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Motion gating and tracking techniques: overview and recent developments

SCIENTIFIC PROGRAMME

Quality assurance in external radiotherapy

The future of radiation therapy. Safe and innovative options, including the CyberKnife System

Integrating the Radixact into a Highly Comprehensive Center

Herlev radiation oncology team explains what MRI can bring

X-Ray Guided Robotic Radiosurgery for Solid Tumors

ABAS Atlas-based Autosegmentation

A method to predict patient specific table coordinates for quality assurance in external beam radiation therapy

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Leksell Gamma Knife Icon contributes to significant growth, greater efficiency and an enhanced patient experience

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Goals and Objectives: Head and Neck Cancer Service Department of Radiation Oncology

Transcription:

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

PATIENT POSITION MONITORING ExacTrac is an in-room based monitoring system that detects intrafractional motion during treatment delivery. Two kv X-Ray units and a proprietary 6D fusion provide fast and highly accurate positioning information at the time of treatment, even at non-coplanar fields. Any deviations in the patient s position that exceed a prescribed tolerance are immediately displayed to the user. Display of detected patient misalignment

PRECISION BASED ON INTERNAL ANATOMY ExacTrac X-Ray Monitoring provides clinicians with a unique insight into the patient position during treatment delivery. The possibility for internal verification during treatment reduces the potential for geographical miss as a result of patient motion, or internal anatomical shift. This also provides the clinician with confidence that the prescribed treatment has been delivered accurately and safely. Examination of automatic bony fusion result within the ExacTrac software

NON-COPLANOR VERIFICATION ExacTrac X-Ray Monitoring compliments existing IGRT solutions by offering the possibility to detect intra-fractional motion. This is not possible with a linac based IGRT system alone, especially at non coplanar fields. ExacTrac X-Ray Monitoring continuously verifies the patient s position as defined by the linac based IGRT system throughout the entire treatment delivery. X-Ray Monitoring at any couch angle

FRAMELESS RADIOSURGERY ExacTrac Frameless Radiosurgery system offers highly accurate delivery of single or multiple fractionated treatments without the need for a conventional head ring. A patient friendly head to shoulder mask facilitates a streamlined workflow, overcoming the restrictions of frame based radiosurgery and improving scheduling flexibility for imaging, planning, and treatment. Stereotactic sub millimeter precision can be achieved with the patient s skull serving as the localization geometry, allowing for single fraction radiosurgery. The ExacTrac frameless system with its three piece, non-invasive mask is compatible with couch tops from multiple vendors. ExacTrac Frameless Radiosurgery System

OPTIONAL AUTOMATED PATIENT POSITIONING Efficiency is an important attribute for any IGRT system, especially given the ever growing patient demand on radiation therapy departments. One method to improve efficiency is to provide a more automated means to patient setup. Optional automatic patient positioning packages may be added to ExacTrac X-Ray Monitoring to allow the patient to be positioned directly from the control area. Positioning packages improve efficiency by minimizing the need to enter the treatment room between fields reducing the overall treatment setup time. Positioning packages are available for either 4D or full 6D robotic alignment. ExacTrac console

LINAC COMPATIBILITY ExacTrac is a fully integrated solution on both Elekta and Varian linacs resulting in a seamless clinical workflow which is fast, safe and highly accurate, and allows the possibility to detect intra-fractional motion. ExacTrac software guarantees that the same patient is automatically loaded on ExacTrac and the linac, and is furthermore compatible with ARIA and MOSAIQ. Deviations in the patient s setup position can be automatically corrected from the control area via the Varian Couch, Elekta Hexapod or Brainlab Robotics, removing the need to enter the treatment room between fields. ExacTrac also offers a range of benefits to extend the capabilities of the Siemens linac. It allows for a quick and efficient setup of cranial and extra cranial cases and the ability to detect intra-fractional motion. If the Siemens linac is to be replace by a Varian or Elekta linac at a later date, the room based ExacTrac can be refitted. ExacTrac on Varian Linac ExacTrac on Elekta Linac ExacTrac on Siemens Linac

IMPLANTED MARKER SUPPORT ExacTrac is a versatile system which not only allows the setup or patients with cranial or head and neck indications but also lesions in the lung, liver, prostate and other organs. In these indications there may be difficulty visualizing the tumor, or the need to compensate for tumor motion due to respiration or random motion. In this situation fiducial markers may be implanted prior to treatment. ExacTrac offers a simple, automated approach to visualize, detect and register implanted markers using a proprietary software solution and 6D fusion. ExacTrac supports a wide range of implanted fiducials such as short and long grains, stents and surgical clips. Automatic implanted marker detection in ExacTrac software

SELECTIVE ANATOMICAL FUSION The Volume of Interest (VOI) tool improves clinical confidence by allowing the user to focus the fusion on the most relevant parts of the patient s anatomy which most closely relate to the target. Areas of anatomy that may not correlate well to the target such as the ribs, adjacent vertebras or other non-rigid objects can be excluded from the 6D fusion ensuring precise patient setup. The VOI defined is automatically used for subsequent imaging and helps ensure a consistent fusion resulting in highly accurate patient positioning. Bony fusion based on volume of interest

brainlab.com 2014 Brainlab AG. RT_BR_EN_ExacTrac_June14_Rev2 Trademark of Brainlab AG in Germany and/of the US.