STEP-BY-STEP-ANLEITUNG

Similar documents
LABORATORY PROCEDURES, STEP BY STEP

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

Invisible Retainer with Single-Tooth Pontic Fabrication Technique (Multi-Tooth Pontic Procedure also available)

Invisible Retainer with Multi-Tooth Pontic Fabrication Technique (Single-Tooth Pontic Procedure also available)

Occlusal Splint Fabrication Technique

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

Universal Plunger Loc Attachment

UDELL DENTAL LABORATORY Instructions for Use

TECHNICAL GUIDE. For use with CEREC

VIP Partner Laboratory (PL) Process Flow

Relining and Rebasing of complete denture

Hex-Lock Abutment System. Restorative Manual

Detailed Step-by Step Instruction for Chairside Splinting

Complete denture impressions

Prior to use, carefully read the instructions for use.

Steps in construction of an interim dental implant-supported hybrid prosthesis:

1. Visually survey the cast for discrepancies and surface defects. 2. Remove surface defects and fill unnatural indentations.

Triad Visible Light Cure System

allinone... unbelievable? But true! Picture: Dr. Thano Kristallis

Listing of Standards By Task

The fitting process of SomnoGuard

Horizontal Jaw Relation

The fitting process of SomnoGuard AP. Hints to complement the user instructions

BEGO PMMA Multicolor Processing information for CAD/CAM-produced restorations

Surgical Guide Technique

Removable Partial Dentures

Preci Clix Instructions for Ball Retained Overdenture Attachments

Prosthetic V. Removable dentures I.

Construction of Removable Partial Denture

Austenal PermaSoft Soft Denture Liner

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

AFFINIS Sys360 putty maximum precision and easy to use

(Instruction For Use) Vertex ThermoSens Rigid

Preci Clix Instructions for Ball Retained Overdenture Attachments

GUIDELINES FOR PROCESSING CELTRA DUO

DENTCA Denture Base II - Directions for Use

RELINING AND REBASING

Listing of Standards By Task

3D Printing Full Dentures with the Form 2

The Reinforced Removable Retainer

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

Bioplus, Artiplus and BioStabil

Denture Duplicator Flask

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

Lab Provisional Procedures

artegral ImCrown manual

Instruction Guide. Today is the day you change the way you live with dentures. How to Apply DenSureFit Soft Silicone Reline Material

ZEST DANVILLE MATERIALS PERIOSCOPY

MM01-Facebow And Bite Registration Procedure Checklist

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Index. Why Choose TCS UK? For the dentist 4. For the lab 7. Why Choose tcs material? 8. tcs Unbreakable 9. tcs iflex 10.

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Shadeguides Ceramic Veneers: Tooth Preparation for Enamel Preservation

Locator retained mandibular complete prosthesis (isy Implant System)

Interim Denture Interim Complete Dental Prosthesis Clinical Steps

Element-Z Screw-Retained Hybrid

Model and stump preparation

INSTRUCTIONS FOR USE AND CARE

GUM COLORS INSTRUCTIONS FOR USE

Complete Denture Clinic Complete Removable Dental Prosthesis Procedures

GUIDELINES FOR PROCESSING CELTRA DUO

Horizontal jaw relations: The relationship of mandible to maxilla in a

FR Attachment Instructions Removable Partial Dentures

Maxillofacial Patient Information Leaflet

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Psychological Impact of Communication

GUIDELINES FOR PROCESSING CELTRA DUO

Patient Instruction Booklet. TAP Elite ThermAcryl. TAP Elite TL. TAP 3 Elite. Revision E, 2013 PRTD29. * Medicare requires Double Lingual Bar Design

Occ 5002, Summer Semester /24/2010

Denture Troubleshooting Guide

INJECTION TECHNOLOGY FOR DENTURE PRODUCTION

2018 MEDIHELP RATES - 54 PRACTICE Kindly see below Tariffs for Medihelp. Please note that not all tariff codes listed are covered by the respective

The CT Scanning Guide

Tips & Tricks Direct fabrication of provisionals. Giving a hand to oral health.

ident CT Guide Protocol

Quintessence copyright. You are not allows to show or use this file for any other purpose than personal use.

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

UDELL DENTAL LABORATORY Instructions for Use AND ERA-RV

Quick Start Guide. Effective January PFm - $125. Emax - $170 EMA - $150. Toll Free. Full Contour Zirconia - $140 Layered Zirconia - $205

SimpleLine II Surgical / Prosthesis Manual

LEARN FROM A LEADER. Intensive, hands-on training that will prepare you to confidently fabricate the appliances you want.

Removable partial dentures

Impression Manual.

CURVES. Anatomically Adaptable IPR strips. Brochure Instructions for use Processing instructions

THE. Curve THE CURVE STRIPPING TOOL

Zirox Guidelines. Supplement to the ZIROX Instructions for Use (dated 07/05)

Patient Instruction Booklet

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

The number of totally edentulous

Perfect provisional restorations

The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances. Illustrated Instruction Manual

Clinical Guideline. for full contour zirconia restorations produced chairside with CEREC Zirconia (milling process).

FLEXSTAR-V. Flexible Appliances. Instruction Manual

IMMEDIATE PARTIAL DENTURE PROSTHESIS - A CASE REPORT

OT EQUATOR CASTABLE Single Attachment for Overdentures

Technical Instructions

SKELETAL PROTHESIS with Vertys Prothesis Excel / Plus heat-curing resin

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Transcription:

STEP-BY-STEP-ANLEITUNG VON TECHNIKERN FÜR TECHNIKER LABORATORY PROCEDURES, STEP BY STEP BY TECHNICIANS FOR TECHNICIANS

Eclipse junior Laboratory Procedures, Step by Step* Splints Drilling Stents Temporaries Baseplates Repairs (small voids) * This description does not replace the regular Directions for Use, but are solely intended to visualize individual procedural steps. Frequently Asked Questions

Splints Survey the cast and indicate the tooth equator. In the anterior region, the margin of the splint should align with the tooth equator, while in the posterior region it should run approximately mm below the tooth equator. Apply a wax cuff that follows this line exactly. Block out any undercuts. Place model in the Eclipse junior VLC Curing Unit. Make sure the top of the model is below the maximum height line (row of holes in the back wall of the chamber). If this is not the case, remove stone from bottom of the model until the entire model is below this line. Duplicate the cast and apply Al-Cote separating agent. Attach the temperature indicator and place the cast on the hot-plate (hotplate needs 0 minutes pre-heating time; level not higher; wear protective gloves) until the temperature indicator has turned black. Remove the cast from the hot-plate and immediately start applying the splint material. 7 8 Place the splint material on the warm cast with the rounded side facing down. Wait briefly until the material has absorbed the heat of the cast, then adapt to the desired form by pressing with your fingers. Splint material, completely adapted. Isolate the opposing cast with MRA and lower according to the edge-to-edge relation of the splint. To avoid adhesion, press the opposing cast only briefly into the soft material and re-open the articulator immediately. As soon as the desired occlusal height and any impressions have been created, place the cast and splint in the refrigerator for 0 minutes. Perform the necessary movements and excursions on the articulator and check the splint accordingly. The splint with impressions.

Splints 9 Paint the splint with ABC protective varnish. 0 Light-cure immediately in the Eclipse junior VLC Curing Unit (menu nightguard). Center the device on the turntable. After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Finish the splint on the articulator. Determine the lateral extension of the splint. Leave the splint on the cast and place in a luke-warm water bath for 0 minutes. For additional information see Section, Frequently Asked Questions. Remove the splint from the cast and finish. Polish with pumice and regular polishing brushes. Use a buff wheel for high-lustre polish. The completed splint on the master cast. The completed splint on the duplicate cast.

Drilling Stents Create parallel bores in the model according to the dentist s instructions. Attach the temperature indicator. Place model in the Eclipse junior VLC Curing Unit. Make sure the top of the model is below the maximum height line (row of holes in the back wall of the chamber). If this is not the case, remove stone from bottom of the model until the entire model is below this line. Insert the analogues in the cast, then fit the bore guides over them. Apply (two thin layers of) Al-Cote separating agent to the dry cast. Allow each separating layer to air-dry well. 7 8 Place the cast on the hot-plate (hotplate needs 0 minutes pre-heating time; level not higher; wear protective gloves) until the temperature indicator has turned black. Remove the cast from the hot-plate and immediately start applying the transparent baseplate material. Place the transparent base material on the warm cast with the rounded side facing down. Wait briefly until the material has absorbed the heat of the cast, then adapt to the desired form by pressing with your fingers. Adapted drilling stent and paint the drilling stent with ABC protective varnish. Light-cure immediately in the Eclipse junior VLC Curing Unit (menu nightguard). Center the device on the turntable. After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Leave the drilling stent on the cast and place in a luke-warm water bath for 0 minutes.

Drilling Stents 9 Remove the drilling stent from the cast and finish. Polish with pumice and regular polishing brushes. Use a buff wheel for high-lustre polish. 0 The finished and polished drilling stent. For additional information see Section, Frequently Asked Questions.

Temporaries Baseline situation. Place model in the Eclipse junior VLC Curing Unit. Make sure the top of the model is below the maximum height line (row of holes in the back wall of the chamber). If this is not the case, remove stone from bottom of the model until the entire model is below this line. Provisionals ( teeth) can be fabricated without clasps due to their excellent fit. But clasps can be added if needed; bend them into the desired shape before adapting the baseplate material. Use an instant adhesive to attach the clasps on the vestibular aspects of the clasp tooth. 7 8 Apply (two thin layers of) Al-Cote separating agent to the dry cast. Allow each separating layer to air-dry well. Attach the temperature indicator and place the cast on the hot-plate (hotplate needs 0 minutes pre-heating time; level not higher; wear protective gloves) until the temperature indicator has turned black. Remove the cast from the hot-plate and immediately start applying the baseplate material. Remove all residual wax from the tooth. Roughen the basal surface and create V-shaped undercuts using the diamond cutter that is part of the set. Prepare the denture teeth for setup. Create a collar groove around the base of the teeth. Make sure the groove marks the end of the gingiva modellation (even interdentally).

Temporaries 9 Heat the fracture area with a hot-air gun before applying the baseplate material. 0 Measure out the Eclipse baseplate material as needed. Hint: Place the baseplate material in the refrigerator for a few minutes. The colder the material the easier it is to break into pieces. Apply the baseplate material (rounded side down) in the desired position. Push baseplate material forward to the edentulous areas. Heat the basal surfaces of the teeth with a hot-air gun. Press the tooth into the baseplate material, moving it into the desired position. A silicone index can be used if desired, as long as these are removed before polymerization (important!). Position the teeth. Remove any excess material with a cold instrument.

Temporaries 7 A regular wax knife can be used for shaping the gingiva. 8 Paint the provisional with ABC protective varnish. 9 Light-cure immediately in the Eclipse junior VLC Curing Unit (menu Flipper/ Base). Center the device on the turntable. After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Leave the provisional on the cast and place in a lukewarm water bath for 0 minutes. 0 Carefully lift the provisional off the cast. If tissue side shade is slightly orange, apply ABC protective varnish to the tissue side. Cure again, tissue side up (menu: BP tissue side). Center the device on the turntable. After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Finish the provisional. Polish with pumice and regular polishing brushes. Use a buff wheel for high-lustre polish. For additional information see Section, Frequently Asked Questions. The completed provisional.

Baseplates In case of undercuts, duplicate the cast first. Reduce any reflection folds that are deeper than mm to a maximum of mm. Fabricate the baseplate on the duplicate cast (which is subsequently destroyed, with the base then being adapted to the modified master cast). Apply retention holes on the dorsal aspect of the mandibular cast. Place model in the Eclipse junior VLC Curing Unit. Make sure the top of the model is below the maximum height line (row of holes in the back wall of the chamber). If this is not the case, remove stone from bottom of the model until the entire model is below this line. Apply (two thin layers of) Al-Cote separating agent to the dry cast. Allow each separating layer to air-dry well. Attach the temperature indicator and place the cast on the hot-plate (hot-plate needs 0 minutes pre-heating time; level not higher; wear protective gloves) until the temperature indicator has turned black. Remove the cast from the hot-plate and immediately start applying the baseplate material. Place the baseplate material on the warm cast with the rounded side facing down. Wait briefly until the material has absorbed the heat of the cast, then adapt the baseplate material. Begin adapting in the vestibular region and then cover the palatal region. 7 8 Displace any excess material dorsally and adapt it to the dorsal holes. This minimizes the A line from lifting during polymerization. Coat the baseplate with ABC protective varnish. Light-cure immediately in the Eclipse junior VLC Curing Unit (menu Flipper/Base). Center the device on the turntable. After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Leave the base on the cast and place in a luke-warm water bath for 0 minutes. Trim the dorsal excess with a separating disk. Lift off the baseplate. If tissue side shade is slightly orange, apply ABC protective varnish to the tissue side. Cure again, tissue side up (menu: BP tissue side). Center the device on the turntable.

Baseplates 9 After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Then finish the baseplate. For additional information see Section, Frequently Asked Questions.

Repairs (small voids)* Widen the fracture. Grind a border/termination resembling a chamfer. Clean the fragments first with water and then with alcohol. Check height of model in the Eclipse junior VLC Curing Unit (according picture Provisionals). Apply Al-Cote separating agent onto the cast. Attach the temperature indicator and place the cast on the hot-plate (hot-plate needs 0 minutes pre-heating time; level not higher; wear protective gloves) until the temperature indicator has turned black. Measure out the Eclipse baseplate material as needed. Hint: Place the baseplate material in the refrigerator for a few minutes. The colder the material the easier it is to break into pieces. Heat the fracture area with a hot-air gun. Adapt baseplate material to the fracture area and smoothen out the baseplate material. 7 8 Paint the denture body with ABC protective varnish. Light-cure immediately in the Eclipse junior VLC Curing Unit (menu BP Repair). Center the device on the turntable. After polymerization is complete, allow to cool to room temperature. Peel off or wash off the protective varnish. Remove from the model. * Full denture repairs and large full baseplate fracture repairs are not recommended. Apply ABC protective varnish to the tissue side. Cure again, tissue side up (menu: BP tissue side). Center the device on the turntable. After polymerization is complete, return the provisional immediately to the cast. Allow to cool to room temperature and remove ABC protective varnish. Finish the denture. Polish with pumice and regular polishing brushes. Use a buff wheel for high-lustre polish. For additional information see Section, Frequently Asked Questions.

Frequently Asked Questions Problem Possible Causes Solution Air bubbles in the baseplate or splint material Baseplate material was adapted too quickly Allow the baseplate material to rest on the cast so it can absorb the heat of the cast and is easier to adapt. Try adapting the baseplate material in only one direction. Baseplate material cannot be adapted Cast is too cold Work on warm casts only. Wait for the temperature indicator to turn black. Baseplate material is viscous and sticky as it is taken Incorrect storage (too hot) Store the material at 7 C. out of the packaging. Some of the baseplate material has not polymerized Shadow areas too large Reduce the height of the reflection fold to mm. When (in the reflection fold). designing cast-metal frameworks, make sure that the shadow areas of the retentions do not exceed mm. Irregular baseplate surface (map-like) Incorrect isolation Use only Al-Cote separating agent. Baseplate breaks as it is lifted off the cast Undercuts. Create a duplicate cast. Destroy the duplicate cast to lift off the baseplate and adapt the baseplate to the modified master cast. White discolouration spots in the baseplate material Heat was generated during roughening/grinding Reduce instrument speed during roughening A line lifts off. Baseplate material not adapted to the dorsal notches. Adapt the baseplate material to the dorsal notches on the cast on the cast.. Baseplate lifted off too soon after polymerization.. The baseplate to remain on the cast. Baseplate material too thick in the area of the A line.. Make sure the baseplate material is not too thick in the area of the A line.. Conditioning time in the pre-heating oven too short.. Extend the conditioning time in the pre-heating oven (at least hours). Teeth have broken out Incorrectly designed or missing retentions Always create a groove in the cervical area and V-shaped undercuts in the basal area. Make sure to fill the basal retentions with setup material.

Frequently Asked Questions Problem Possible Causes Solution Difficulties lifting a polymerized item from the cast Soaking omitted or incorrect or missing separating agent Isolate casts before adapting the baseplate material. Use only Al-Cote separating agent. Soak casts in a hand-warm water bath for 0 minutes before lifting off the baseplate. Problems while finishing the occlusal surface of a splint Missing separating agent on the opposing cast. Always isolate using MRA. Use short, controlled Occlusal check of the opposing cast took too long. movements to check the occlusion. Flowout of the occlusal surface of a splint Splint was not polymerized immediately after Polymerize the splint immediately after finishing the finishing the occlusal surface occlusal surface. Baseplate materials in a repair job do not fuse Improper cleaning. Fracture surfaces were not heated Carefully clean the fracture surfaces with water and before adapting the baseplate material. alcohol. Pre-heat the fracture surfaces with a hot-air gun. Broken splint Cast improperly blocked out or surveyed Block out and survey the cast properly. Insufficient lustre Buff wheel dirty Use a clean buff wheel. Plaster particles in the baseplate material Incorrect plaster used Use only Class IV dental stone. Bubble formation during polymerization ABC protective varnish omitted Paint with ABC protective varnish before each polymerization step. Not completely polymerized. Two or more casts were placed into the polymerization unit.. Polymerize one item at a time.. Top of the model is obove height line. Make sure that top of model is below the height line Basic rules Always work on a warm model. For repairs, make sure to pre-heat the denture body as well (hot-air gun at level ). Always allow the cast to cool after polymerization. Soak the cast before removing an item (for approximately 0 minutes). Before measuring out the material, place it in the refrigerator for a few minutes. Otherwise, store at 7 C.

08/080/GVD Stand/Last revision: 0/008 Manufacturer: DENTSPLY Dentsply International Inc. York PA 70-087 USA EU-Representative: DeguDent GmbH A Dentsply International Company Postfach D-0 Hanau