Ultra hcg Combo Test

Similar documents
IVD Revised 22 July, 2008

Chorionic Gonadotropin Human ELISA Kit

ifob Test Rev. P5576-A, 04/16 5. Read the result in 5-10 minutes. RESULTS AFTER 10 MINUTES. Important: DO NOT READ

hcg Combo Test Positive Negative Expel entire contents of the barrel into the sample well of the test device. No drop counting required.

ifob Test Rev. P /15 6. Read the result in 5-10 minutes. RESULTS AFTER 10 MINUTES. Important: DO NOT READ

INSTANT-VIEW H. pylori Rapid Test CLIA WAIVED Test for Whole Blood QUALITATIVE IN-VITRO DIAGNOSTIC TEST FOR EXTERNAL USE ONLY

NEGATIVE POSITIVE. Rev , 06/11. 5 min. Mono Test. For fi ngertip. blood: 1 DROP 1 DROP For serum, whole blood. plasma or. samples.

PROCEDURE. Sekisui Diagnostics OSOM ifob Rapid Test. Title: Procedure #: Institution: Prepared by: Date: Title: Accepted by: Date adopted: Title:

CDIA TM Rubella IgG/IgM Rapid Test Kit

For Detection of TSH in Whole Blood: For Professional Use. Whole Blood One-Step Rapid TSH Assay for Hypothyroidism Screening in Adults

See external label 2 C 8 C 96 tests B-HCG (Total) Cat #

Opiates Rapid Test. Cat. No.:DTS137 Pkg.Size:50T. Intended use. General Description. Principle Of The Test. Reagents And Materials Provided

Pregnancy Test on a Urine Sample. Amal Alamri

hcg (Human) CLIA Kit Catalog Number KA assays Version: 01 Intended for research use only

Summary of Significant Changes at this Revision. Items Required. Printed copies are uncontrolled unless there is an allocated Copy Number on page 1

Hepatitis C Virus (HCV) Antibody Test

Treponema Pallidum (TP) Antibody Test

Mono Test 1 DROP 1 DROP. For fingertip blood: For serum, plasma or whole blood samples in tubes: Rev , 05/09

Ultra-sensitive Human TSH ELISA Kit. MyBioSource.com

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

hcg 01 English - Ref.: 904 Ref.:904 Insert Intended use. System for quantitative determination of Human Chorionic Gonadotropin - hcg in serum.

TSH (Human) ELISA Kit

Human Ultrasensitive Thyroid Stimulating Hormone ELISA Kit

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

QuickTox Drug Screen Dipcard (with and without Adulteration Tests)

INTENDED USE. MATERIALS REQUIRED BUT NOT PROVIDED 1.Urine sample collection container. 2.Timer or clock with setting of 5 minutes or more.

hc Step Serum/Urine, hc Step Detector and HumaPreg Serum/Urine

CLIA Complexity: WAIVED INTENDED USE SUMMARY AND EXPLANATION

Infectious Mononucleosis IM Cassette Test RAPU04A830

SAMPLE PROCEDURE , 07/11

CLIA Complexity: Waived

Human Thyroid Stimulating Hormone (TSH) ELISA Kit

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

Procedures: LifeSign MI Myoglobin/CK-MB/Troponin I Test. Prepared by Date Adopted Supersedes Procedure # Review Date Revision Date Signature

The Rapid D-Dimer Test is a chromatographic immunoassay for the qualitative detection of D-Dimer in human whole blood and plasma.

25-Hydroxy Vitamin D TOTAL (25HD) on Liaison XL

QuickTox Drug Screen Dipcard (with and without Adulteration Tests)

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Human FSH (Menopause) (midstream) Rapid Test (RAP-4155) For the rapid detection of Follicle Stimulating Hormone (hfsh) in human urine specimens

PreventID TSH. Additional information Manual Medical information

HAV IgM Rapid Test(Cassette)

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

Rapid-VIDITEST FOB Blister

Fastect II Drug Screen Dipstick Test Training and Certification Program

Unigold Recombigen HIV 1/2 Training for HIV Testing Sites. Updated: February 2018 Cicely Richard Office of HIV/AIDS

ToxCup Drug Screen Cup (with and without Adulteration Tests) Training and Certification Program

Free beta hcg quantitative assay is designed for quantitative measurement of chorionic Gonadotropin free beta subunit in human serum.

HAV IgG/IgM Rapid Test

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Rapid-VIDITEST. Strep A Card. One step Strep A Card for the detection of Group A Streptococcal antigen from throat swabs or culture.

Rapid-VIDITEST. Strep A Blister. One step Strep A Blister for the detection of Group A Streptococcal antigen from throat swabs or culture.

TB LAM Ag Lateral Flow Assay Standard Operating Procedure

MALARIA P. FALCIPARUM / P. VIVAX

Cortisol (Sheep) ELISA Kit

Human Thyroid Stimulating Hormone CLIA kit

T R A I N I N G G U I D E

ToxCup Drug Screen Cup (with and without Adulteration Tests) Training and Certification Program

Rapid-VIDITEST Calprotectin

FinTest IgG4 Screen 20 ELISA KIT

Chlamydia trachomatis (CHLa)Test Kit

Hexagon PSA. Design Verification. Contents

Rapid-VIDITEST. Helicobacter pylori. One step Helicobacter pylori Blister test. Instruction manual

Dengue IgG/IgM/NS1 Combo Rapid Test Device

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

See external label 96 tests ULTRASENSITIVE THYROID STIMULATING HORMONE (u-tsh) TSH Ultra Sensitive

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

SAMPLE PROCEDURE 907-9, 06/11

Annex 1 Instruction for Use

Follicle Stimulating Hormone (FSH) ELISA Catalog No (96 Tests)

Fecal H. pylori Antigen Rapid Test (Strip)

Rubella Latex Agglutination Test

See external label 2 C-8 C Σ=96 tests Cat # 3122Z MICROWELL ELISA THYROID STIMULATING HORMONE (TSH) ENZYME IMMUNOASSAY TEST KIT TSH.

Rapid-VIDITEST C. difficile Ag (GDH) Card/Blister

Malaria Pf/pan antigen Rapid Test

Free Estriol ELISA. For the quantitative determination of free estriol in serum

Rapid-VIDITEST. Rota-Adeno Blister. One Step Rotavirus and Adenovirus Antigen Blister test. Instruction manual

Human Hemoglobin Colorimetric Detection Kit

Human Follicle-Stimulation Hormone ELISA Kit

The LH (serum) ELISA kit is an enzyme immunoassay for the quantitative in vitro diagnostic measurement of the Luteinizing Hormone (LH) in serum.

DRUG-CONJUGATES The drug buprenorphine is conjugated to protein and immobilized as a line on a membrane at the BUP location labeled on the device.

USO PROFESSIONALE PROFESSIONAL USE

Toxoplasma gondii IgM ELISA Kit

Human Free Thyroxine (ft4) CLIA Kit

INSTANT-VIEW H. pylori Rapid Test CLIA WAIVED Test for Whole Blood QUALITATIVE IN-VITRO DIAGNOSTIC TEST FOR EXTERNAL USE ONLY

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

Serum Amyloid A ELISA

Human Chorionic Gonadotropin ELISA

Procine sphingomyelin ELISA Kit

Rapid-VIDITEST. Influenza A+B

25 OH Vitamin D Rapid test

H. Pylori Whole Blood Rapid Test

HBeAg and HBeAg Ab ELISA Kit

Mouse C3 (Complement Factor 3) ELISA Kit

Apolipoprotein A-1 ELISA

Strep-a-Test Twister Test

Testosterone ELISA. Catalog No (96 Tests) For Research Use Only. Not for use in Diagnostic Procedures.

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Human Cytomegalovirus IgM ELISA Kit

Rubella virus IgG ELISA Kit

NCCLS. Accutest H. pylori WB Test. (Catalog. No. ID-92A225) For Professional and In Vitro Diagnostic Use Only

Transcription:

STEP 1 For each test, open one OSOM hcg Serum/ Urine pouch, and label the OSOM device with the patient ID. STEP 2 Holding the dropper in a vertical position, add 3 drops of sample into the Sample Well (S) STEP 3 Read the results at 3 5 minutes. Do not interpret the results after 5 minutes. Ultra hcg Combo Test Positive Two pinkish-purple lines, one each at the Test Position (T) and at the Control Position (C). Each of the following indicates a positive test result. Negative Only one pinkish-purple line, at the Control Position (C). Invalid A distinctive colored line at the Control Position (C) should always appear. The test is invalid if no Control line forms. Rev. P-51560, 04/15

Ultra hcg Combo Test CLIA Complexity: Waived for Urine Non-Waived for Serum THIS TEST IS FOR PROFESSIONAL USE IN PHYSICIANS OFFICES AND CLINICAL LABORATORIES. INTENDED USE OSOM Ultra hcg Combo Test is a simple immunoassay for the qualitative detection of human chorionic gonadotropin (hcg) in serum or urine for the early confirmation of pregnancy. SUMMARY AND PRINCIPLE Human chorionic gonadotropin (hcg) is a glycoprotein hormone produced by the placental trophoblastic cells shortly after the fertilized ovum is implanted in the uterine wall. 1-4 The primary function of hcg is to maintain the corpus luteum during early pregnancy. The appearance of hcg in both the urine and serum soon after conception and its rapid rise in concentration make it an excellent marker for confirmation of pregnancy. The hormone may become detectable in both urine and serum as early as 7 to 10 days after conception. 1-4 The concentration of hcg continues to rise rapidly, frequently exceeding 100 miu/ml by the first missed menstrual period and peaking in the 30,000 100,000 miu range by 10 to 12 weeks into pregnancy. The hormone is comprised of two non-covalently bound dissimilar subunits containing approximately 30% carbohydrate by weight. 5 The alpha subunit is structurally similar to other human pituitary glycoprotein hormones, whereas the beta (ß) subunit confers unique biological and immunological specificity to the molecule. 6,7 The OSOM Ultra hcg Combo Test is a rapid serum or urine test for detecting hcg. The test is a solid-phase, two-site immunometric assay in which a combination of monoclonal and polyclonal antibodies is used to selectively detect elevated levels of hcg in serum or urine with a high degree of sensitivity. In the test procedure, sample is added to the sample well with the aid of a transfer pipette and sample is allowed to soak in. If hcg is present in the specimen, it will react with the conjugate dye, which binds to the antibody on the membrane to generate a colored line. Presence of two colored lines, one in the Test position (T) and the other in the Control position (C), indicates a positive result, while the absence of the line in the Test position indicates a negative result. REAGENTS AND MATERIALS PROVIDED OSOM Ultra hcg Combo Test kit contains enough reagents and materials to perform all the tests. 25 OSOM Ultra hcg devices (Test device containing the polyclonal anti-hcg coated membrane and a pad with the mouse monoclonal IgG (anti-hcg)-dye conjugate in a protein matrix containing 0.1%sodium azide) Disposable dropper Package insert NOTE: Two extra devices have been included in the kit for external QC testing. MATERIALS MAYBE REQUIRED BUT NOT PROVIDED Timer Specimen cup Latex gloves Positive and Negative Controls (Sekisui Diagnostics recommends the OSOM hcg Urine Control (Catalog number 134) and the OSOM hcg Serum Control (Catalog Number 138)). WARNING AND PRECAUTIONS For in vitro diagnostic use only. Do not use beyond the expiration date. The OSOM Ultra hcg Combo Test device should remain in its sealed pouch until ready for use. Use appropriate precautions for the collection, handling, and storage of specimens. All human blood products should be treated as potentially infectious and handled with good laboratory practices. STORAGE AND STABILITY OSOM Ultra hcg Combo Test kit should be stored at 2 30 C (36 86 F) in the sealed pouch. SPECIMEN COLLECTION AND PREPARATION Urine Assay For optimal early detection of pregnancy, a first morning urine specimen is preferred since it generally contains the highest concentration of hcg. However, randomly collected urine specimens may be used. Collect the urine specimen in a clean glass or plastic cup. Urine containing excessive bacterial contamination should not be used since spurious results may occur with such specimens. Serum Assay Remove the serum from the clot as soon as possible to avoid hemolysis. When possible, clear, non-hemolyzed specimens should be used. Specimens containing particulate matter may give

inconsistent test results. Such specimens should be clarified by centrifugation prior to assaying. If refrigerated, bring specimens to room temperature (18 30 C) prior to testing. Frozen specimens must be completely thawed, thoroughly mixed, and brought to room temperature prior to testing by allowing the specimens to stand at room temperature for at least 30 minutes. SPECIMEN STORAGE If testing will not be performed immediately, the specimens should be refrigerated (2 8 C) for up to 48 hours. Bring specimens to room temperature prior to testing. For prolonged storage, specimens may be frozen and stored below 20 C. Frozen specimens must be completely thawed, thoroughly mixed, and brought to room temperature prior to testing by allowing the specimens to stand at room temperature for at least 30 minutes. Avoid repeated freezing and thawing. If specimens are to be shipped, they should be packed in compliance with Federal regulations covering the transportation of etiologic agents. For urine samples, add sodium azide to a concentration of 0.1% as a preservative and ship by the quickest means possible. PROCEDURES PROCEDURAL SUMMARY The procedure consists of adding the specimen to the sample well in the device and watching for the appearance of colored lines on the membrane. PROCEDURAL NOTES The instructions below must be followed to achieve optimal test reactivity with serum or urine specimens. Allow specimens and the OSOM Ultra hcg Combo Test device to stand at room temperature for at least 30 minutes prior to testing. Label the OSOM device with the patient name or control number. Allow the dropper to fill with sample. Holding the dropper in a vertical position, add 3 drops of sample into the Sample Well (S). Handle all specimens as if capable of transmitting disease. After testing, dispose of the OSOM device and the dropper following good laboratory practices. Consider each material that comes in contact with specimen to be potentially infectious. TEST PROCEDURE STEP 1 For each test, open one OSOM Ultra hcg Combo Serum/Urine pouch, and label the OSOM device with the patient ID. STEP 2 Holding the dropper in a vertical position, add 3 drops of the sample into the Sample well (S). STEP 3 Read the results at 3 5 minutes. Do not interpret the results after 5 minutes. INTERPRETATION OF RESULTS Positive Two pinkish-purple lines, one each at the Test Position (T) and at the Control Position (C). Each of the following indicates a positive test result. NOTE: A specimen containing a detectable level of hcg will generate a pinkish-purple line at the Test Position (T) within 3 5 minutes. The time required to generate the line is dependent on the hcg concentration in the sample. Some positive results can be read in as early as one minute. To be interpreted as positive,the pinkish-purple line in the Test Position (T) should be clearly distinguishable from the background color of the membrane. In strong positive tests, the color intensity of the line at the Control Position (C) may be much lighter than that of the line at the Test Position (T). a. Two strong pinkish-purple lines, one each at the Test (T) and Control (C) Positions b. One strong pinkish-purple line at the Test Position (T) and one light pinkish-purple line at the Control Position (C). c. One light pinkish-purple line at the Test Position (T) and one pinkish-purple colored line at the Control Position (C).

Negative Only one pinkish-purple line, at the Control Position (C). NOTE: In the absence of hcg, or in the case that the hcg concentration is below the detection limit of the test, there will be no apparent line at the Test position. The control line at the Control Position should be clearly readable. Invalid A distinctive colored line at the Control Position (C) should always appear. The test is invalid if no Control line forms. NOTE: If there is no distinct pinkish-purple line visible at the Control Position, the test is inconclusive. If there is a suspected procedural error made by the user, the result should be considered inconclusive. It is recommended that in this case the test be repeated or a fresh specimen be obtained and tested. A Control line should always appear. The absence of a pinkish-purple line at the Control Position means the test is invalid and should be repeated with a new test device. LIMITATIONS As with any assay employing mouse antibodies, the possibility exists for interference by human anti-mouse IgG antibodies (HAMA) in the sample. Similarly, specimens from patients who have been routinely exposed to animals or to animal serum products may contain heterophile antibodies which may cause erroneous results. Elevated hcg levels have been reported in patients with both gestational and nongestational trophoblastic diseases. 8, 9, 10 The hcg of trophoblastic neoplasms is similar to that found in pregnancy, so these conditions, including choriocarcinoma and hydatidiform mole, should be ruled out before pregnancy is diagnosed. An extremely low concentration of hcg during the early stage of pregnancy can give a negative result. In this case, another specimen should be obtained at least 48 hours later and tested. The hcg level may remain detectable for several weeks after normal delivery, delivery by cesarean section, spontaneous abortion, or therapeutic abortion. 11 The hcg level in the case of spontaneous abortion may be very low and eventually decrease. The test is highly sensitive, and specimens which test positive during the initial days after conception may later be negative due to natural termination of the pregnancy. Natural termination occurs in 22% of clinically unrecognized pregnancies and 31% of pregnancies overall. 12 Subsequent testing of a new urine or serum sample after an additional 48 hours is recommended in order to confirm that the hcg level is rising as indicated in a normal pregnancy. The concentration of hcg may be very low in the case of ectopic pregnancy. 13 A suspected ectopic pregnancy may be further evaluated using a quantitative hcg assay. Very high levels of hcg may exist in certain pregnancies and pathological conditions (e.g., choriocarcinoma and hydatidiform mole). This may weaken the signal line. The physician should evaluate data obtained from this kit in light of other clinical information. Samples which contain excessive bacterial contamination or have been subjected to repeated freezing and thawing should not be used because such specimens can give spurious results. Urine samples collected after consumption of a large amount of fluids may contain a lower hcg concentration. If such a sample is negative, a first morning specimen should be obtained and retested. In rare occasions, persistent low levels of hcg present in men and in nonpregnant women (concentrations 3 to 100 miu/ml) may result in positive results. 14,15 USER QUALITY CONTROL INTERNAL CONTROL: Each OSOM Ultra hcg Combo Test device has a built-in control. The Control line is an internal positive procedural control. A distinct reddish-purple Control line should appear at C position indicating an adequate sample volume is used, the sample and reagent are wicking on the membrane, and the test reagents at the Control line and the conjugate-color indicator are reactive. In addition, the clearing background in the Result window is considered as an additional procedural control by providing a distinct readable result. This may be considered an internal negative procedural control. If background color appears in the Result window which interferes with your ability to read the test result and obscure the formation of the control band, your result may be invalid. If the problem persists, contact Sekisui Diagnostics Technical Service at 800-332-1042 (US Customers only) EXTERNAL CONTROL: External controls may also be used to assure that he reagents are working properly and that the assay procedure is followed correctly. It is recommended that a control be

tested before using a new lot, untrained operator or a new shipment of kit as good laboratory testing practice and that users follow federal, state, and local guidelines for quality control requirements. For information on how to obtain controls, contact Sekisui Diagnostics Technical Service: Tel 800-332-1042 (U.S. Customers only). EXPECTED VALUES OSOM Ultra hcg Combo Test is capable of detecting hcg levels of 25 miu/ml (WHO 3rd International Standard). HCG levels in normal early pregnant women vary and hcg levels often exceed 100 miu/ ml by the first day of the missed menstrual period. 1 The test is usually capable of detecting hcg by the first day of the missed menstrual period. PERFORMANCE CHARACTERISTICS Clinical Evaluation-Urine Assay A total of 247 blind clinical urine samples were studied. These specimens were assayed with OSOM Ultra hcg Combo Test and Tandem Icon II according to the package inserts (Table 1). Thirty-six (36*) samples are from menopausal women TABLE 1 (URINE ASSAY) OSOM Ultra hcg Combo Test vs. Tandem Icon II with Urine Specimens TEST RESULT (# OF SAMPLES) Tandem Icon II OSOM Ultra hcg Combo Positive 78 78 Negative 133 133 Menopausal Not Determined 36 (Negative) The data demonstrate the excellent correlation between OSOM Ultra hcg Combo Test and Tandem Icon II. The clinical accuracy and sensitivity of the two tests are found comparable. Overall Accuracy: 100% Relative Sensitivity: 100% Relative Specificity: 100% Clinical Evaluation Serum Assay A total of 425 blind clinical serum samples were studied. These specimens were assayed with OSOM Ultra hcg Combo Test and Tandem Icon II according to the package inserts. The results demonstrate 100% relative sensitivity, 99% relative specificity and 99.5% overall accuracy (Table 2). TABLE 2 (SERUM ASSAY) OSOM Ultra hcg Combo Test vs. Tandem Icon II with Serum Specimens. TEST RESULT (# OF SAMPLES) Tandem Icon II + - Positive 215 2 OSOM Ultra hcg Combo (Serum/Urine) Negative 0 208 Total 215 210 Overall Accuracy: 99.5% Relative Sensitivity: 100% Relative Specificity: 99% PHYSICIANS OFFICE LABORATORY EVALUATION (Proficiency Study) Reproducibility of OSOM Ultra hcg Combo test results was evaluated at three physicians office laboratories using a total of 120 blind control samples. The control panels were prepared in serum or urine. Each panel consisted of 5 negative ( ), 5 low positive (25 miu/ml hcg), 5 moderate positive (200 miu/ ml hcg), and 5 high positive (500mIU/mL hcg) samples. The results obtained at each site agreed 100% with expected results and with predicate tests compared in parallel. Sensitivity- Urine Assay Standard controls (calibrated to the WHO 3rd International Standard) ranging from 5 miu/ml to 40 miu/ml in urine were tested in 20 replicates. The results confirmed sensitivity of 25 miu/ml.

Sensitivity- Serum Assay Standard controls (calibrated to the WHO 3rd International Standard) ranging from 5 miu/ml to 40 miu/ml in serum tests were tested in 20 replicates. The results confirmed sensitivity of 25 miu/ml. Specificity Thirty-six (36) urine specimens collected from menopausal women were studied. Specimens from menopausal women are known to interfere frequently with pregnancy tests due to cross-reactivity with other gonadotropin hormones. These specimens were assayed with OSOM Ultra hcg Combo Test. All 36 specimens were found negative. The assay is free from interference with other commonly known homologous hormones when tested at the levels specified below (Table 3). TABLE 3 Homologous Hormones: Urine Serum hfsh 1000 miu/ml 1000 miu/ml hlh 500 miu/ml 500 miu/ml htsh 1000 μiu/ml 1000 μiu/ml) POTENTIALLY INTERFERING SUBSTANCES Potentially interfering substances were prepared at the following concentrations in both urine and serum which contain either 0 or 25 miu/ml hcg. These samples were tested with the OSOM Ultra hcg Combo. No interference was found (Table 4). TABLE 4 Substance Added: Concentration Added in Urine in Serum Drugs Acetaminophen 20 mg/dl 20 mg/dl Acetylsalicylic Acid 20 mg/dl 20 mg/dl Ampicillin 20 mg/dl 20 mg/dl Ascorbic Acid 20 mg/dl 20 mg/dl Atropine 20 20 mg/dl 20 mg/dl Caffeine 20 20 mg/dl 20 mg/dl Gentisic Acid 20 mg/dl 20 mg/dl Phenothiazine 20 mg/dl 20 mg/dl Phenylpropanolamine 20 mg/dl 20 mg/dl Salicylic Acid 20 mg/dl 20 mg/dl Tetracycline 20 mg/dl 20 mg/dl Urinary Analytes Bilirubin 2 mg/dl 30 mg/dl Glucose 2000 mg/dl 2000 mg/dl Hemoglobin 25 mg/dl 250 mg/dl Ketones 100 mg/dl - Protein 2000 mg/dl 14000 mg/dl Triglycerides - 2000 mg/dl Homologous Hormones hfsh 1000 miu/ml 1000 miu/ml hlh 500 miu/ml 1000 miu/ml htsh 1000 μiu/ml 1000 μiu/ml

REFERENCES 1. Braunstein, G.D., Rasor, J., Adler, D., Danzer, H., and Wade, M.E. Serum Human Chorionic Gonadotropin Levels Throughout Normal Pregnancy. Am. J. Obstet. Gynecol. 1976; 126:678. 2. Krieg, A.F. Pregnancy Tests and Evaluation of Placental Function in: Clinical Diagnosis and Management by Laboratory Methods, 16th ed., Henry, J.B. (ed.) W.B. Saunders Co., Philadelphia, pp. 680, 1979. 3. Brody, S. and Carlstrom, G. Immunoasay of Human Chorionic Gonadotropin in Normal and Pathologic Pregnancy. J. Clin. Endocrinol. Metab. 1962; 22:564 4. Hussa, R.O. Human Chorionic Gonadotropin, A Clinical Marker: Review of its Biosynthesis. Ligand Review 1981; 3:6.. 5. Swaminathan, N. and Bahl, O.P. Dissociation and Recombination of the Subunits of Human Chorionic Gonadotropin. Biochem. Biophys. Res. Commun. 1970; 40:422. 6. Ross, G.T. Clinical Relevance of Research on the Structure of HumanChorionic Gonadotropin. Am. J. Obstet. Gynecol. 1977; 129:795. 7. Reuter, A.M., Gaspard, U.J., Deville, J-L., Vrindts-Gevaert, Y. and Franchimont, P. Serum Concentrations of Human Chorionic Gonadotrophin and its Alpha and Beta Subunits. 1. During Normal Singleton and Twin Pregnancies. Clin. Endocrinol. 1980; 13:305. 8. Morrow, C.P., et al. Clinical and Laboratory Correlates of Molar Pregnancy and Trophoblastic Disease. Am. J. Obstet Gynecol. 1977; 50:424-430. 9. Dawood, M.Y., Saxena, B.B., and Landesman, R. Human Chorionic Gonadotropin and its Subunits in Hydatidiform Mole and Choriocarcinoma. Am. J. Obstet. Gynecol. 1977; 50:172 181. 10. Braunstein, G.D., Vaitukaitis, J.L., Carbone, P.P., and Ross, G. T. Ectopic Production of Human Chorionic Gonadotropin by Neoplasms. Ann. Inter. Med. 1973; 78:39-45. 11. Steier, J.A., Bergsjo, P., and Myking, O.L. Human Chorionic Gonadotropin in Maternal Plasma After Induced Abortion, Spontaneous Abortion, and Removed Ectopic Pregnancy. Am. J. Obstet. Gynecol. 1984; 64:391-394. 12. Wilcox, A.J., Weinberg, C.R., O Connor, J.F., Baird, D.D., Schlatterer, J.P., Canfield, R.E., Armstrong, E.G., and Nisula, B.C. Incidence of early loss of pregnancy. N. Engl. J. Med. 1988; 319:189-194. 13. Murray, H., Baakdah, H., Bardell, T., and Tulandi, T. Diagnosis and treatment of ectopic pregnancy. CMAJ 173: 905-912, 2005. 14. Cole, L.A. Immunoassay of human chorionic gonadrotropin, its free subunits and metabolites. Clinical Chemistry 43:12. 2233-2243, 1997. 15. Snyder, J.A., Haymond, S., Parvin, C.A., Gronowski, A.M., and Grenache, D.G. Dynamic considerations in the measurement of human chorionic gonadotropin in aging women. Clinical Chemistry 51:10. 1830-1835, 2005. ASSISTANCE For assistance, call Sekisui Diagnostics Technical Assistance at 800-332-1042. REORDER Item No. 1004 (25 Test Kit) OSOM is a registered U.S. trademark of Sekisui Diagnostics, LLC. Princeton BioMeditech Corporation 4242 U.S. Hwy 1, Monmouth Jct. New Jersey 08852, U.S.A. 1-732-274-1000 www.pbmc.com MF Sekisui Diagnostics, LLC 6659 Top Gun Street San Diego, CA 92121 USA 800-332-1042 Lexington, MA 02421 Tel: 800-332-1042 www.sekisuidiagnostics.com 2015 Sekisui Diagnostics, LLC All rights reserved.

SYMBOLS KEY Instructions For Use (Read) Item Number Store At Expiration Date CONT Contents DEV Test Device IFU Instructions For Use PIP 2 Transfer Pipette Do Not Reuse For In Vitro Diagnostic Use Lot Number Manufacturer MF Manufactured For