POWERFUL CARDIAC MONITORING

Similar documents
REVEAL AF IN YOUR CRYPTOGENIC STROKE PATIENTS

November 2016 POWERFULLY SIMPLE CARDIAC MONITORING. SEEQ External Cardiac Monitor (ECM) System. From the leaders who brought you Reveal LINQ ICM

IS THERE A LINK BETWEEN ATRIAL FIBRILLATION AND MY STROKE? Finding answers about cryptogenic stroke

2017 ACC/AHA/HRS SYNCOPE GUIDELINES

POWERFULLY SIMPLE CARDIAC MONITORING

UNLOCK THE ANSWER. The Reveal LINQ TM System lets your physician learn about your heart while you live your life.

SYNCOPE DIAGNOSIS NEEDED. CHALLENGE ACCEPTED.

UTILITY OF THE IMPLANTABLE LOOP RECORDER

COMMONLY BILLED CODES AND ASSOCIATED 2018 MEDICARE RATES

WHAT CAN I DO ABOUT ATRIAL FIBRILLATION? Finding answers about atrial fibrillation

Cardiac Event Monitors

WHY AM I FAINTING? Finding answers about unexplained fainting

Clinical Policy: Holter Monitors Reference Number: CP.MP.113

CRYPTOGENIC STROKE THERAPY AWARENESS PRESENTATION. Reveal LINQ TM

2018 ESC SYNCOPE GUIDELINES SUMMARY

CLINICAL MEDICAL POLICY

INSERTABLE CARDIAC MONITORS FROM ATRIAL FIBRILLATION TO SYNCOPE:

MEDICAL POLICY Cardiac Event Monitors/ Cardiac Event Detection

ECG monitoring after ischemic stroke of TIA of unknown source with an insertable monitor? YES

WAS ATRIAL FIBRILLATION THE CAUSE OF MY STROKE? Finding answers about cryptogenic stroke

SYNCOPE THERAPY AWARENESS PRESENTATION

FREQUENTLY ASKED QUESTIONS MONITORING

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

CARDIAC MONITORING THE EARLY DAYS

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

LINQ THE RHYTHM TO THE SYMPTOM

CATHETER ABLATION CODING & REIMBURSEMENT GUIDE. Updated September 2018

2017 Cardiovascular Symposium CRYPTOGENIC STROKE: A CARDIOVASCULAR PERSPECTIVE DR. WILLIAM DIXON AND DR. VENKATA BAVAKATI SOUTHERN MEDICAL GROUP, P.A.

National Medical Policy

Model 5392 EPG Temporary Pacer

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Ambulatory Cardiac Monitors and Outpatient Telemetry Corporate Medical Policy

PACING AT THE BUNDLE OF HIS

Θα πρέπει να αναζηηείηαι η παροσζία ζιωπηλής κολπικής μαρμαρσγή ζε αζθενείς με κρσπηογενές εγκεθαλικό επειζόδιο; Ποιά είναι η καλύηερη μέθοδος;

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW

Call Medtronic at 1 (800) to verify the patient s current implanted system

Recurrent Unexplained Palpitations (RUP) Study

2009 CPT Codes for Cardiac Device Monitoring

Clinical Policy Title: Real-time outpatient cardiac monitoring

Diagnosing atrial fibrillation using implantable devices

Spontaneous Atrial Fibrillation and Noacs and Reversal agents

CONFIRM Rx INSERTABLE CARDIAC MONITOR CONTINUOUS HEART MONITORING LIVE LIFE WITHOUT SKIPPING A BEAT

CMS Limitations Guide - Cardiovascular Services

Medicare Advantage Medical Policy

Index. cardiology.theclinics.com. Note: Page numbers of article titles are in boldface type.

Speakers. 2015, American Heart Association 1

La strategia diagnostica: il monitoraggio ecg prolungato. Michele Brignole

Clinical Policy Title: Implantable cardiac loop recorders

Corporate Medical Policy

Seek and Ye Shall Find: Surprising Findings When Using the ILR-LINQ

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Tilt Table Testing MM /01/2015. HMO; PPO; QUEST Integration 09/22/2017 Section: Medicine Place(s) of Service: Office, Outpatient

Cerebrovascular accident icd 10

What the general cardiologist should know about arrhythmia Stroke prevention in AF" Peter Ammann Kantonsspital St. Gallen

A SIMPLE SOLUTION FOR CARDIAC MONITORING

MEDICAL POLICY SUBJECT: AMBULATORY EVENT MONITORS

ATRIAL FIBRILLATION ANSWERS. A Patient Education Handbook on Electrophysiology

Make the Connection A clinical compendium on the relationship between AF, stroke, and early intervention

TOP 3: EMBRACE. Lucy Vieira MD FRCP Neurologist MUHC. N Engl J Med Volume 370(26): June 26, David J.

Topic: Outpatient Cardiac Telemetry Date of Origin: April Section: Medicine Last Reviewed Date: December 2014

Clinical Policy Title: Implantable cardiac loop recorders

Cryptogenic Stroke: The role of silent Atrial Fibrillation

Medtronic, Inc.

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

Remote Monitoring & the Smart Home of the 21 Century

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY

A PATIENT S GUIDE TO THE LEFT ATRIAL APPENDAGE CLOSURE. Reducing the risk of stroke in atrial fibrillation

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

Atrial Fibrillation Ablation: in Whom and How

Management of Atrial Fibrillation. Leon Ptaszek, MD, PhD, FACC, FHRS 25 March 2018

NATIONAL INSTITUTE FOR CLINICAL EXCELLENCE SCOPE. Clinical guideline for the management of atrial fibrillation

Direct oral anticoagulants for Embolic Strokes of Undetermined Source? George Ntaios University of Thessaly, Larissa/Greece

Patient Resources: Arrhythmias and Congenital Heart Disease

Post-ablation Management: Drug therapy, Anticoagulation and long-term Monitoring

PFO Management update

Clinical Policy: Microvolt T-Wave Alternans Testing Reference Number: CP.MP.212

as the cause of recurrent syncope 3 allows appropriate management aimed

pat hways Medtech innovation briefing Published: 16 February 2018 nice.org.uk/guidance/mib141

CRYPTOGENIC STROKE. Reveal LINQ TM THERAPY AWARENESS PRESENTATION

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

FORAME OVALE PERVIO E ICTUS CRIPTOGENETICO: Dimensione del problema. Roberto Mantovan, MD, PhD U.O. Cardiologia Ospedale M.

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

EAE RECOMMENDATIONS FOR TRANSESOPHAGEAL ECHO. Cardiac Sources of Embolism. Luigi P. Badano, MD, FESC

Destination Therapy SO MUCH DATA IN SUCH A SMALL DEVICE. HeartWare HVAD System The ONLY intrapericardial VAD approved for DT.

Syncope evaluation: the role of syncope clinics Michele Brignole Arrhythmologic Centre, Lavagna, Italy

Why to monitor AF ablation success?

2018 Diagnosis Coding Fact Sheet

Implantable Cardiac Monitors for Atrial Fibrillation (AF) Detection: Ready for Routine Use?

Common Codes for ICD-10

ΑΣΥΜΠΤΩΜΑΤΙΚΗ ΚΟΛΠΙΚΗ ΜΑΡΜΑΡΥΓΗ

Clinical Case 1 A patient with a syncope Panos E. Vardas President Elect of the ESC, Prof of Cardiology, University Hospital of Crete

ESC Stockholm Arrhythmias & pacing

DO YOU HAVE PAROXYSMAL ATRIAL FIBRILLATION?

Atrial fibrillation (AF) has been the. Subclinical Atrial Fibrillation, Embolic Risk, and Anticoagulant Treatment

Supplementary Online Content

OUTPATIENT CARDIOVASCULAR TELEMETRY

Cryptogenic Stroke: What Don t We Know. Siddharth Sehgal, MD Medical Director, TMH Stroke Center Tallahassee Memorial Healthcare

Transcription:

POWERFUL CARDIAC MONITORING Indications, Guidelines, Clinical Evidence, and Coding Overview for Diagnosing Suspected Arrhythmias and Monitoring Known A-Fib Reveal LINQ Insertable Cardiac Monitoring System

Indications The Reveal LINQ Insertable cardiac monitor (ICM) is an implantable patient-activated and automatically activated monitoring system that records subcutaneous ECG and has been cleared by the FDA for use in two groups of patients: Patients with clinical syndromes or situations at increased risk of cardiac arrhythmias Patients who experience transient symptoms such as dizziness, palpitation, syncope, and chest pain that may suggest a cardiac arrhythmia The device has not been specifically tested for pediatric use. Clinical Evidence Cryptogenic Stroke and Underlying Atrial Fibrillation (CRYSTAL AF) Study 1 In 441 patients randomized either to Reveal ICM or standard medical care and followed for 36 months: Continuous monitoring detected over seven times more patients with AF at the 12-month end point When followed for three years, AF was detected at a rate of 30% in the ICM arm vs. 3% in the standard follow-up arm Short-term monitoring is not sufficient as the median time to AF detection over 12 months of follow-up was 84 days 97% of patients who had AF detected were prescribed OAC 88% of patients with AF would have been missed if only monitored for 30 days Place of Reveal ICM in the Care Pathway and Treatment of Patients with Unexplained Recurrent Syncope (PICTURE) Study 2 In 570 patients implanted with a Reveal ICM and followed for a year: Overall, patients had seen an average of three different specialists for management of their syncope The median number of tests performed per patient in the total study population was 13 (inter-quartile range 9 20) Most patients (70%) had been hospitalized at least once for syncope One third (36%) of these patients had experienced significant trauma in association with a syncopal episode Randomized Assessment of Syncope Trial (RAST) 3 60 unexplained syncope patients randomized to conventional testing or a Reveal ILR The diagnostic yield was 43% for ILR vs. 20% for conventional, and the cost/diagnosis of ILR was 26% less than conventional testing Recurrent Unexplained Palpitations (RUP) Study 4 50 patients with infrequent sustained palpitations were randomized either to a conventional external monitoring strategy or to a Reveal ILR Diagnosis was obtained in 21% of the conventional group and 73% of the ILR group, with significantly lower cost per diagnosis in the ILR group ($4,584 vs. $10,152) 5

Guidelines ESC Guidelines: Management of Atrial Fibrillation (2016) 6 Class IIa In stroke patients, additional ECG monitoring by long-term noninvasive ECG monitors or implanted loop recorders should be considered to document silent atrial fibrillation. AHA/ACC/HRS Guidelines for the Management of Syncope (2017) 7 Class I, Class IIa If the initial evaluation is unclear and a cardiac cause is suspected, cardiac monitoring is a Class I recommendation. The IIa recommendation for ICM is supported by clinical evidence and randomized controlled trials. AHA/ACC Scientific Statement on the Evaluation of Syncope 8 This approach (ILRs) is more likely to identify the mechanism of syncope than is a conventional approach that uses Holter or event monitors and EP testing, and is cost-effective. HRS Consensus Statement on Catheter and Surgical Ablation of AF (2012) 9 Patients in whom discontinuation of systemic anticoagulation is being considered should consider undergoing continuous ECG monitoring to screen for asymptomatic AF/AFL/AT. Coding distinctions ICM: Used to monitor physiologic heart data, generally in patient with heart failure. ILR (Reveal LINQ): is used to monitor recorded heart rhythm data to help diagnosis and monitor A-Fib. Reveal-related procedure coding Procedure Coding for Physician and Outpatient Hospital Services CPT 10 Description 33282 Implant pat-active ht record (ILR) 33284 Remove pat-active ht record (ILR) 93285 ILR device eval/programming 93291 ILR device interrogation (in person) 93298 ILR device interrogation (remote, prof svc) 93299 ILR device interrogation (remote, tech svc) C Code Required for Medicare Hospital OP Services C1764 Event recorder, cardiac (implantable) ICD-10-PCS Procedure Code and Definition 11 0JH632Z Insertion of Monitoring Device into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach (e.g., Reveal LINQ ICM) 0JPT32Z Removal of Monitoring Device from Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach (e.g., Reveal LINQ ICM) This information is intended only for educational use and does not replace seeking coding advice from the payer and/or your coding staff. The ultimate responsibility for correct coding lies with the provider of services. Please contact your local payer for their interpretation of the appropriate codes to use for specific procedures. Medtronic makes no guarantee that the use of this information will prevent differences of opinion or disputes with Medicare or other third party payers as to the correct form of billing or the amount that will be paid to providers of service.

Diagnosis Coding for Suspected Arrhythmias Diagnosis coding should reflect the highest level of known specificity. The appropriate code(s) must be used to identify diagnoses, symptoms, conditions, problems, complaints, or other reason(s) for the clinical encounter. If an arrhythmia is suspected, but not yet confirmed, the diagnosis code(s) should reflect the symptoms, signs, or risk factors which have led the physician to suspect an arrhythmia. If the patient has several symptoms, signs, and/or risk factors, multiple diagnosis codes may be used to document the patient s clinical condition. Syncope/Pre-Syncope Signs and Symptoms R00.2 Palpitations R42 R55 Dizziness and giddiness [light-headedness] Syncope and collapse [pre-syncope] R56.9 Unspecified convulsions [seizures NOS] R94.31 Abnormal electrocardiogram [ECG] [EKG] A-Fib Monitoring I47.0-I49.9 Paroxysmal tachycardia, atrial fibrillation and flutter, and other cardiac arrhythmias (include secondary diagnosis for long term anticoagulation therapy, Z79.01 if appropriate) Classifying Cryptogenic Stroke Cryptogenic stroke is an ischemic stroke which, despite extensive work-up, cannot be attributed to underlying cardioembolism, large artery atherosclerosis, small artery occlusion, or other known cause. The immediate culprit in acute ischemic stroke is embolism, thrombosis, or narrowing/stenosis of a precerebral or cerebral vessel. After acute stroke treatment, work-up focuses on determining the underlying disorder that caused the embolism, thrombosis, or narrowing/stenosis. In most cases, this is ultimately identified as embolism thrown off by the heart, atherosclerotic thrombosis, or small vessel occlusion due, for example, to external compression. Less commonly, other identified underlying etiologies include patent foramen ovale, thrombophilia, and non-bacterial endocarditis. In cryptogenic stroke, the underlying cause is not identified, either because work-up was negative or because work-up cannot be completed, for example because the cause is reversible and there was insufficient time. Alternately, there may be multiple, concomitant risk factors that do not allow the physician to determine a specific underlying cause. As an ischemic stroke of undetermined etiology, cryptogenic stroke places the patient at higher risk for recurrence. This material is adapted from the AHA guide: https://www.strokeassociation.org/idc/groups/stroke-public/@wcm/ @hcm/@sta/documents/downloadable/ucm_477051.pdf. Cryptogenic Stroke Acute Episode I63.0-I63.9 G45.0-G45.3, G45.8-G45.9 Post-Acute Phase I69.30-I69.998 Acute ischemic stroke Transient cerebral ischemic attacks and related syndromes Sequelae of cerebral infarction [late effect of ischemic stroke] and other cerebrovascular disease Z86.73 Personal history of transient ischemic attack (TIA), and cerebral infarction without residual deficits

References 1 Sanna T, Diener HC, Passman RS, et al. Cryptogenic Stroke and Underlying Atrial Fibrillation (CRYSTAL AF). N Engl J Med. June 26, 2014;370(26):2478-2486. 2 Edvardsson N, Frykman V, van Mechelin R, et al. Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry. Europace. February 2011;13(2):262-269. 3 Krahn AD, Klein GJ, Yee R, Hoch JS, Skanes AC. Cost implications of testing strategy in patients with syncope: randomized assessment of syncope trial. J Am Coll Cardiol. August 6, 2003;42(3):495-501. 4 Giada F, Gulizia M, Francese M, et al. Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy. J Am Coll Cardiol. May 15, 2007;49(19):1951-1956. 5 Based on an exchange rate of 1.5 to $1. 6 Kirchhof P, Benussi, S, Kotecha D, et al. 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J. Published online August 27, 2016. Accessed online August 31, 2016 at: http://eurheartj.oxfordjournals. org/content/early/2016/08/26/eurheartj.ehw210. 7 Shen WK, Sheldon RS, Benditt DG, et al. 2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. August 1, 2017;70(5):e39-e110. 8 Strickberger SA, Benson DW, Biaggioni I, et al. AHA/ACCF Scientific Statement on the evaluation of syncope from the American Heart Association Councils and the American College of Cardiology Foundation: in collaboration with the Heart Rhythm Society (2006). Circulation. January 17, 2006;113(2):316-327. 9 Calkins, et al. HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. June 2007;4(6):816-861. 10 CPT is a registered trademark of the American Medical Association. 11 Based on guidance from Clarity Coding, Linda Holtzman, MHA, RHIA, CCS, CCS-P, CPC, CPC-H. Brief Statement Indications Reveal LINQ LNQ11 Insertable Cardiac Monitor and Patient Assistant The Reveal LINQ Insertable cardiac monitor is an implantable patient-activated and automaticallyactivated monitoring system that records subcutaneous ECG and is indicated in the following cases: Patients with clinical syndromes or situations at increased risk of cardiac arrhythmias Patients who experience transient symptoms such as dizziness, palpitation, syncope, and chest pain, that may suggest a cardiac arrhythmia. The device has not been tested specifically for pediatric use. Patient Assistant The Patient Assistant is intended for unsupervised patient use away from a hospital or clinic. The Patient Assistant activates the data management feature in the Reveal Insertable cardiac monitor to initiate recording of cardiac event data in the implanted device memory. Contraindications There are no known contraindications for the implant of the Reveal LINQ Insertable cardiac monitor. However, the patient s particular medical condition may dictate whether or not a subcutaneous, chronically implanted device can be tolerated. Warnings/Precautions Reveal LINQ LNQ11 Insertable Cardiac Monitor Patients with the Reveal LINQ Insertable cardiac monitor should avoid sources of diathermy, high sources of radiation, electrosurgical cautery, external defibrillation, lithotripsy, therapeutic ultrasound, and radio frequency ablation to avoid electrical reset of the device, and/or inappropriate sensing as described in the Medical procedure and EMI precautions manual. MRI scans should be performed only in a specified MR environment under specified conditions as described in the Reveal LINQ MRI Technical Manual. Patient Assistant Operation of the Patient Assistant near sources of electromagnetic interference, such as cellular phones, computer monitors, etc., may adversely affect the performance of this device. Potential Complications Potential complications include, but are not limited to, device rejection phenomena (including local tissue reaction), device migration, infection, and erosion through the skin. See the device manual for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/ adverse events. For further information, please call Medtronic at 1-800-328-2518 and/or consult Medtronic s website at medtronic.com. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. Medtronic 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Toll-free in USA: 800.633.8766 Worldwide: +1.763.514.4000 Medtronic and the Medtronic logo are trademarks of Medtronic. Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company. medtronic.com UC201704396b EN 2017 Medtronic. Minneapolis, MN. All Rights Reserved. Printed in USA. 11/2017