Supporting Information

Similar documents
Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

Mass Spectrometry. Actual Instrumentation

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Supporting information

Supporting Information

CAMAG TLC-MS INTERFACE

Dienes Derivatization MaxSpec Kit

Sulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms

Components of a Mass Spectrometer

A pillar[2]arene[3]hydroquinone which can self-assemble to a molecular zipper in the solid state

Electronic Supplementary Information

Supplementary information. Miniaturised 3D printed polypropylene reactor for online reaction. analysis by mass spectrometry

An Unusual Glycosylation Product from a Partially Protected Fucosyl Donor. under Silver Triflate activation conditions. Supporting information

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Introduction. This paper

Steviol Glycosides from Stevia rebaudiana Bertoni

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

1. Sample Introduction to MS Systems:

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Introduction to LC/MS/MS

Supplementary Information

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

MALDI-TOF. Introduction. Schematic and Theory of MALDI

CESI-MS of Intact Proteins

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

More structural information with MS n

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

SUPPORTING INFORMATION. High Throughput Reaction Screening using Desorption Electrospray Ionization Mass Spectrometry

Supporting Information

Oxysterol Derivatization MaxSpec Kit

Zinc Chloride Promoted Formal Oxidative Coupling of Aromatic Aldehydes and Isocyanides to α- Ketoamides

Analyzing Phenyl Ureas and Carbamates with HPLC/API-MS. Presented by Chen-Kai Meng, Ph.D. Applications Chemist

Fundamentals of Soft Ionization and MS Instrumentation

Concours d'ingénieur de laboratoire Externe

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Characterization of Noncovalent Complexes of Polyelectrolytes by Mass Spectrometry

Uptake and Metabolism of Phthalate Esters by Edible Plants

Solid Phase Peptide Synthesis (SPPS) and Solid Phase. Fragment Coupling (SPFC) Mediated by Isonitriles

Ionization Methods. Neutral species Charged species. Removal/addition of electron(s) Removal/addition of proton(s)

PHOSPHOPEPTIDE ANALYSIS USING IMAC SAMPLE PREPARATION FOLLOWED BY MALDI-MS and MALDI PSD MX

Supporting Information

Electronic Supplementary Information

Synthetic chemistry-led creation of a difluorinated biaryl ether non-nucleoside reverse transcriptase inhibitor

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Supporting information for the article

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Mechanistic Insight into Oxidized N,N-Dimethylacetamide as a source of Formaldehyde Related Process Derivatives

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Selection and Optimization of the Sample Introduction System

Mass Spectrometry Introduction

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Supplementary Information

Supporting Materials. Experimental Section. internal standard TMS (0 ppm). The peak patterns are indicated as follows: s, singlet; d,

SUPPLEMENTARY MATERIAL

Supporting Information

Supporting Information

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Authors. Abstract. Introduction. Environmental

Electronic supplementary material to: The influence of L-carnitine on the formation of preneoplastic and

Measuring Lipid Composition LC-MS/MS

CHAPTER: 4. The Mass Spectrometric Investigation of Proton Induced Cyclisations of 2-nitro-N-phenyl anilines In Gas-Phase

ph Switchable and Fluorescent Ratiometric Squarylium Indocyanine Dyes as Extremely Alkaline Sensors

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Ion Source. Mass Analyzer. Detector. intensity. mass/charge

MS/MS Scan Modes. Eötvös University, Budapest April 16, MS/MS Scan Modes. Árpád Somogyi. Product Ion Scan Select. Scan. Precursor Ion Scan Scan

John Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA

Synthesis of Sequence-Controlled Acrylate Oligomers. via Consecutive RAFT Monomers Additions

Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ MS

Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010

Development of a near-infrared fluorescent probe for monitoring hydrazine in serum and living cells

SUPPLEMENTARY INFORMATION

PosterREPRINT EVALUATION OF A RF-ONLY STACKED RING BASED COLLISION CELL WITH AXIAL FIELD FOR THE LC-MS-MS ANALYSIS OF THE METABOLITES OF RABEPRAZOLE

Supporting Information. First synthetic entry to the trimer stage of 5,6-dihydroxyindole polymerization: orthoalkynylaniline-based

Determination of Amantadine Residues in Chicken by LCMS-8040

Supplementary Information

The use of mobile-device data to better estimate dynamic population size for wastewater-based epidemiology

SUPPLEMENTARY INFORMATION

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Single Quadrupole Compact Mass Spectrometer for Liquid Sample

Lipidomic Analysis by UPLC-QTOF MS

Determination of B-vitamins in Energy Drinks by CE/MS/MS

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

Time (min) Supplementary Figure 1: Gas decomposition products of irradiated DMC.

Acyl Radical Reactions in Fullerene Chemistry: Direct Acylation of. [60]Fullerene through an Efficient Decatungstate-Photomediated Approach.

Supporting Information

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

California TOF/QTOF Users Meetings: MS Settings. Jim Lau, Agilent Technologies.

Application Note # FTMS-46 solarix XR: Analysis of Complex Mixtures

LC/MS Crossroads. Jerry Pappas Sales Representative 265 Davidson Avenue Somerset, NJ

The Analysis of Jojoba Oil by LC-Coordination Ion Spray-MS (LC-CIS-MS)

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Transcription:

Supporting Information Wiley-VC 2007 69451 Weinheim, Germany

Electrospray Ionization Mass Spectrometric Study on the irect rganocatalytic α-alogenation of Aldehydes Cesar A. Marquez, Francesco Fabbretti and Jürgen. Metzger* (I) Experimental The mass spectrometric measurements were performed on the quadrupole-time of flight (Q- Tof) instrument Micromass Premier (Waters, Manchester) equipped with a standard ESI ion source containing a stainless steel spray capillary (127µm inner diameter, 229µm outer diameter, 181mm of length). A capillary voltage of 500V, and source and desolvation temperature of 40 C were used as standard ESI-MS operation conditions. The collisioninduced dissociation (CI, collision gas argon) was performed in the collision cell region, using a capillary voltage of 2.5kV, source and desolvation temperature of 40 C, and collision energy of 8a.u. as standard ESI-MS/MS operation conditions. Butanal 1, -chlorosuccinimide (CS), -bromosuccinimide (BS), -iodosuccinimide (IS), -methyl-lproline, L-prolinamide 3, methanol, and C 2 Cl 2 were obtained from Aldrich (Steinheim, Germany). All chemicals were used without further purification but CS, BS that were purified by recrystallization from water, and IS, recrystallized from a mixture of 1,4-dioxan/CCl 4. Them three were dried afterwards in vacuum using P 2 5 as drying agent. C 2 Cl 2 was dried before used using Ca 2 as drying agent.

(II) General Procedures a) n-going reaction MS experiments. Two syringes assembled in different pumps, one containing the on-going reaction and the other containing a diluting solvent, e.g., methanol, were allowed to feed a mixing tee (Techlab, PEEK mixing tee) directly connected to the ESI or APCI source (see graphic S1). The reacting solution was this way diluted before entering the ion source. When any of the reactants was present in suspension, the reaction was let to take place in a vessel. Samples of the reacting mixture were then collected at different intervals, diluted with methanol, and injected directly into the ESI source. Reacting solution Methanol Mixing tee ESI-MS Graphic S1. Schematic setup for the on-going reaction MS experiments. A solution of 1 (45µL, 0.5M), 3 (5.7mg, 50mM), and -halosuccinamide (X=Br and I, 1M) in 1mL C 2 Cl 2 was prepared. With the help of the assembly above described, this mixture was injected into the ESI source. An injection speed of 0.1µLmin 1 was settled for the reactants solution, and 40µLmin 1 for the methanol. CS did not dissolve completely in these conditions, remaining in part as a suspension. In the experiments performed with it, samples of 5µL of the reacting mixture were collected at different intervals, diluted with 1mL methanol, and injected directly into the ESI source. The intermediates 5 and 6 where intercepted and analyzed using this assembly. For the detection of T1 and T3, a mixture of methanol/water (1:1, v/v) was used as diluent instead of methanol. 2

b) Continuous-flow MS experiments. Two syringes containing solutions of the different reagents were allowed to feed a mixing tee. A second mixing tee was attached between that and the ionization source to reduce the final sample concentration entering the mass spectrometer (see graphic below). The reaction volume (0.75µL, bold in graphic S2) for bimolecular processes was then that of the capillary connecting both mixing tees; the volume of the metal spray capillary is rendered negligible after the strong dilution process in the second mixing tee. The reaction time was controlled by the flow rate set up on the different pumps. Reagent A Methanol ESI-MS Mixing tees Reagent B Graphic S2. Schematic setup for the continuous-flow MS experiments. Two solutions were prepared, the first containing 1 (4.5µL, 50mM) and XS (50mM) in 1mL dried C 2 Cl 2 (Reagent A), and the second 3 (0.57mg, 0.5mM) in 1mL dried C 2 Cl 2 (Reagent B). These two solutions were transfer to syringes and allowed to react by using the assembly described above. An injection speed of 5µLmin 1 was settled for the reactants solutions, and 40µLmin 1 for the methanol. These conditions allowed the study of the medium ~1s after initiating the reaction. ther times were achieved by varying the flow speed in the pumps. The evolution in time of 5, T2/6, and their homologues using BS and IS were analyzed using this assembly. 3

c) alogens 1,3-shift MS experiments. A solution of 1 (4.5µL, 50mM) and 3 (0.57mg, 0.5mM) in 1mL dried C 2 Cl 2 was prepared in the presence of molecular sieves (Reagent A), and in a different vessel, a solution of XS (50mM) in 1mL dried C 2 Cl 2 (Reagent B). These two solutions were transfer to syringes and allowed to react by using the microreactor system. An injection speed of 90µLmin 1 was settled for the reactants solutions. These conditions allowed the study of the medium ~1s after initiating the reaction. For the experiments performed on the ual ESI, reagent A was sprayed using the main capillary of the Q-Tof, while reagent B was sprayed using the traverse capillary. The ual ESI assembly is depicted below (graphic S3). Graphic S3. Schematic representation and picture of the ual ESI assembly used. 4

(III) Selected Spectra. a) Atmospheric Pressure Chemical Ionization. Figure S1. APCI-MS spectrum of the reaction of 1 and CS catalyzed by 3 after 30min. b) Kinetics. Figure S2. Evolution in time for the intermediates 4 and 5 + ( ), 6 (ο) from ESI-MS experiments, and the ratio between S + and CS + (+) from APCI-MS experiments. 5

c) Reaction Intermediates. Figure S3. ESI-MS/MS of 3 +. Figure S4. ESI-MS/MS of the ion signal corresponding to 4 and 5 + (m/z 169). 6

(IV) Iminium ion (4)/ enamine (5 + ) differentiation Ions 4 and 5 + can be distinguished by using a deuterated medium. A mixture of 1 (50mM) and 3 (0.5mM) in per-deuterated methanol was prepared and allowed to react during 30 minutes (see graphic S4). Reacting solution Methanol-d 4 Mixing tee ESI-MS Graphic S4. Schematic setup for the iminium ion / enamine differentiation experiments. With the help of the assembly above described, this mixture was injected into the ESI source. An injection speed of 0.1µLmin 1 was settled for the reactants solution, and 40µLmin 1 for the per-deuterated methanol. Scheme S1 shows the different species and the m/z ratios expected for the main CI fragment ions. 7

m/z 171, corresponding to 5-d 2 + and 4-d 2 : 2 2-2 5-d 2 + 4-d 2 5-d 2 -C 2 -C 2 CI Fragments: 5-d 2 + 2 m/z 124 m/z 124 m/z 172, corresponding to 5-d 2 +, 4-d 3, and 5-d 3 + : 2 2-2 5-d 2 + 4-d 3 5-d 3 + 5-d 3 -C 2 -C 2 -C 2 CI Fragments: 5-d 3 + 2 m/z 124 m/z 125 m/z 171, corresponding to 5-d 3 + and 4-d 4 : 2 m/z 125 5-d 3 + 4-d 4 -C 2 -C 2 CI Fragments: m/z 125 m/z 126 Scheme S1. ifferent species and the m/z ratios expected for the main CI fragment ions for the iminium ion / enamine differentiation. According with the scheme depicted above, the ion with m/z 171 is not suitable for the calculation of the signal ratio enamine/iminium since both enamine (5-d 2 + ) and iminium (4-d 2 ) fragment to produce the same ion with m/z 124. In the case of the ion with m/z 172, it is not suitable either; the fragment with m/z 125 corresponds to the enamines (5-d 2 +, 5-8

d 3 + ) and the iminium (4-d 3 ). owever, the fragments observed for the ion with m/z 173 allows a rough estimation for the ratio enamine/iminium, since the enamine (5-d 3 + ) only fragments to m/z 125, meanwhile the iminium (4-d 4 ) only to 126. From the spectra studied (shown below), and considering only the ratio of the intensities of the ions m/z 125 and m/z 126 observed in the MS/MS spectrum of ion m/z 173, an enamine/iminium ratio of 10:1 is estimated. Figure S5. ESI-MS spectrum of the reaction of 1 (50mM) and 3 (0.5mM) in per-deuterated methanol after 30min. The signal with m/ 119 corresponds to 3-d 3 +. n the right, the same spectrum expanded in the m/z range corresponding to the deuterated products 4 and 5 +. 2 CI Figure S6. ESI-MS/MS spectrum for the ion with m/z 119 in the same experiment. 9

Figure S7. ESI-MS/MS spectrum for the ion with m/z 171, corresponding to 5-d 2 + and 4- d 2. n the right, the same spectrum expanded in the m/z range corresponding to the main fragmentation. Figure S8. ESI-MS/MS spectrum for the ion with m/z 172, corresponding to 5-d 2 +, 5- d 3 +, and 4-d 3. n the right, the same spectrum expanded in the m/z range corresponding to the main fragmentation. Figure S9. ESI-MS/MS spectrum for the ion with m/z 173, corresponding to 5-d 3 + and 4- d 4. n the right, the same spectrum expanded in the m/z range corresponding to the main fragmentation. 10

(V) Fragmentation Patters. a) -halo-l-prolinamides. Figure S10. ESI-MS/MS of the reaction of 3 (2.5mM) and XS in dried C 2 Cl 2 (2.5mM, X=Cl, Br, and I respectively). otice that -chloro-l-prolinamide fragments to release C 2. owever, when the amine hydrogen is replaced by a methyl group (see below), the fragmentation Cl-C 2 is favored. For BS and IS, the main fragmentation is that to release X-C 2, forming the ion with m/z=70. 11

b) -methyl- -halo-l-proline. Figure S11. ESI-MS/MS of the reaction of -methyl-l-proline (2.5mM) and XS (2.5mM, X=Cl, and I respectively). The halogenation is not favored in any case, but clear spectra could be achieved from signals at noise level in case of CS and IS. o clear spectrum could be obtained for BS. The main fragmentation is that to release X-C 2, producing the fragment ion with m/z=84. 12

c) Synthesized 6-type compounds (L-prolinamide + haloketones). Figure S12. ESI-MS/MS of the reaction in dried C 2 Cl 2 of 3 (2.5mM) and 3-chloro-2- butanone (2.5mM), and the reaction of 3 (2.5mM) and 1-bromo-2-butanone (2.5mM) respectively. otice that the release of formamide (ion signals at m/z 158 and 202 respectively) and X (m/z 167 in both cases) are predominant in both cases. 13