Thermo Scientific Hypersil BDS Columns

Similar documents
ACE C18-AR Use the Power!

Analytical and Preparative SFC Columns

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Sepax Technologies, Inc.

Roc On with These Dependable LC Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Impurity Profiling of Carbamazepine by HPLC/UV

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Ultimate Core Performance to Maximize Your Investment

Restek Ultra II HPLC Columns

Hyper-fast & Super-rugged

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

Ultra Columns. also available. ordering note

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

Ultra Columns HPLC COLUMNS

SeQuant ZIC -HILIC For all who expect more...

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Am I getting the very best value from my UHPLC analyses?

GlycanPac AXR-1 Columns

SeQuant ZIC -HILIC For all who expect more...

HPLC. Varian Dynamax Preparative HPLC Columns

Comparison of a UPLC Method across Multiple UHPLC Systems

The Raptor HILIC-Si Column

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Fortis Method Development Options

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

Choosing Preparative Columns

Agilent Technologies Prep LC Columns

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

IAM Chromatography. Introduction

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

Hypersil BDS and Hypersil Classical HPLC Columns

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Extended Temperature Range Impact on HPLC Column Stability and Performance

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

ACE Excel UHPLC Columns

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

SUMMARY, CONCLUSION & RECOMMENDATIONS

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

LC Columns with Liquid Separation Cell Technology

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

YMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Core-Shell Technology for Proteins and Peptides

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

A New Era in SFC Column Technology

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Normal Phase HPLC Column COSMOSIL SL-II

YMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

Unequalled durability against water elution. % tr

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

Confident, lower-pressure analysis of carbohydrates, alcohols, and organic acids. Agilent Hi-Plex Ligand-Exchange HPLC Columns

Results of Using Re-washed Vials and Closures

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

Kromasil The way to peak performance in liquid chromatography

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

GlycanPac AXH-1 Columns

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

176 YMC Chiral Columns

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Extended Application Note

HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Columns for HPLC. Columns for HPLC

C30 ISOMERS HAVE MET THEIR MATCH

A Novel HILIC Column for High Speed N-linked Glycan Analysis

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Raptor HILIC-Si: Simplify the Switch to HILIC

Column Stability and Performance under High Temperature HPLC Conditions

QuickSplitTM Flow Splitters

2012 Waters Corporation 1

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis

Transcription:

Technical Guide Version 2 Thermo Scientific Hypersil BDS Columns Robust and rugged, delivering excellent reproducibility and peak symmetry Part of Thermo Fisher Scientific

Thermo Scientific Hypersil BDS Columns When you are scaling the peaks in chromatography, every piece of equipment is critical. Since their introduction in 1989, Thermo Scientific Hypersil BDS columns have gained a reputation as one of the most robust, reproducible and reliable HPLC columns available. Based on highly base deactivated silica with endcapping, Hypersil BDS columns exhibit the following key features, separation after separation: Excellent reproducibility Reduced tailing Very robust and rugged with long column lifetimes Excellent peak symmetry for basic and acid compounds This Technical Guide provides an overview of the Hypersil BDS product range and how quality and reproducibility of the phases and columns are monitored.

Base Deactivated Silica and Bonded Phases The use of covalently-bonded silica stationary phases in HPLC allows the analysis of a broad range of analytes. Along with rapid equilibration times, and significantly improved mass transfer characteristics over liquid-liquid partition chromatography, this has resulted in the hugely successful advancement of HPLC as a modern day analytical technique. However, covalently-bonded silica stationary phases often have specific limitations. Many chemical properties associated with derivatized silicas used in HPLC have a strong effect on analyte interactions. These properties are specific to either the derivatized ligand itself, or the remaining underivatized silanol groups on the silica surface. In particular, the number and acidity of these remaining silanol groups is of significance. It is the silanol groups that are responsible for the acid-base properties of the base silica, contributing to the overall polarity of the surface even when the surface method is derivatized. Their type and acidity play an important role in determining resolution and peak shape for various classes of compounds being analyzed. Peak tailing and low efficiencies of both basic and acidic compounds can occur due to unwanted silanol interactions. The effect is most apparent with some of the earlier silicas developed for HPLC, in which silanol groups are quite acidic. For these types of silicas, the observed effect on peak shape requires the mobile phase to include either a competing base such as triethylamine or a competing acid such as acetic acid. Both peak shape and column performance are improved dramatically when the appropriate competing agent is used. The effect of the additive is to compete with any silanol interactions that interfere with analyte retention and peak shape. Consequently, the additive must be present in fairly high concentrations, often as much as 1% volume fraction of the mobile phase. The use of additives in such a concentration can often have a deleterious effect on the column lifetime and also on reproducibility of the method. 1

These difficulties have provided the impetus for the development of an improved range of chromatographic silicas (base deactivated silicas) that allow the analysis of both basic and acidic compounds without the requirement for competing additives in the mobile phase. A proprietary treatment to the silica surface results in significant improvements to the homogeneity of the surface silanol population prior to derivatization. The result has been that the bonded silica surface no longer requires a competing acid or base in the mobile phase to achieve acceptable peak shapes for problematic analytes. This is illustrated in Figure 1. Hypersil BDS packings were among the first base deactivated silica HPLC packings to offer the characteristics associated with these surface improvements, offering benefits such as: Reduced silanol interactions Reduced peak tailing Reduced need for mobile phase additives Excellent peak symmetry Long column lifetimes Improved performance with basic, neutral and acidic compounds 1 3 2 4 2 4 Column: Hypersil BDS C18 5 µm, 150 x 4.6 mm Part Number: 28105-154630 Eluent: 60% ACN/40% 0.05M KH 2 PO 4, ph 4.5 Detector: UV @ 254nm 3 Sample: 1. Pyridine 2. N-Methylaniline 3. N, N-Dimethylaniline 4. Toluene 1 0 2 4 6 Min. Typical C18 0 2 4 6 Min. Hypersil BDS C18 Figure 1: Hypersil BDS shows improved peak symmetry over traditional ODS for difficult analytes 2

The Base Deactivation Process The popularity of columns packed with C18 derivatized silica is due to their wide breadth of application, encompassing non-polar and neutral, acidic, and basic analytes. The selectivity of a given C18 phase can depend on the type of silane used and the synthetic conditions, as both of these factors will affect the density of the bonded phase on the surface. This density of the bonded phase is important since the greater the access of an analyte to the underlying silica support, the greater the opportunity for secondary interactions such as hydrogen bonding. There are approximately five silanol (Si-OH) groups per nm 2 of surface on the silica, corresponding to 8-9 mmol/m 2. It is stereochemically impossible to react more than ~50% of the silanol groups even with ligands as small as trimethylsilane (C1). The surface composition of silica prior to derivatization is very important. As illustrated in Figure 2a, at most silica surfaces it is usual to have a variety of silanol groups: (1) lone silanols, (2) siloxanes, (3) geminal silanols and vicinal silanols. The presence of these silanols in a derivatized silica can result in unwanted silanol interactions with the analytes which can give rise to peak tailing and changes in retention and selectivity on a typical alkyl C18 packing, such as: Si -OH NH 2 -R (Hydrogen bonding with base) Si - OH O=RCOH (Hydrogen bonding with acid) Si O- +NH 3 -R (Ion exchange with base) Figure 2a Figure 2b (1) (2) (3) H O Si Si Si Si O O O O O OH HO O H H H H O O O O Si Si Si Si O O O O O Figure 2: The base deactivation process produces a homogenous surface 3

Using a proprietary production process, the surface of the Hypersil BDS silica is made much more homogeneous, so that all silanols are of the same type (vicinal silanols), as illustrated in Figure 2b (previous page). The resultant silica surface is more uniform and ready for surface derivatization. Special care is taken to ensure a high density of coverage followed by thorough end-capping in order to further reduce the possibility of any silanol interactions. As a consequence of the base deactivation process, the silanols that are still present after surface derivatization become much more friendly toward basic and acidic compounds, and the packing material becomes an excellent choice to develop highly reproducible methods. Silanols are less acidic and are less likely to be available for ion exchange interaction with ionized basic analytes, and are also less likely to hydrogen bond with polar analytes. With these reduced silanol interactions, Thermo Scientific Hypersil BDS columns are ideally suited for analysis of a wide range of analytes including both acids and bases, with peak shape and column performance significantly improved. Reproducibility HPLC owes its success as an analytical technique to several factors. One of the most important has been the ability to transfer newly developed methods to other laboratories around the world. In this respect, column reproducibility has played a crucial role. Column performance parameters are key factors in determining reproducibility from column to column. A column with poor efficiency may lead to loss in resolution, while stationary phase differences may lead to a change in selectivity that can result in loss of resolution. Thermo Scientific strives continuously to provide HPLC columns of the highest standard with a strong focus on reproducibility. Different brands of C18 media may differ from one another significantly. This is largely due to differences in the properties of the underlying silica. Differences in surface area and silanol population give rise to stationary phases that differ in carbon content, ligand type or silanol content. Differences within a particular column brand may also occur simply due to the amorphous properties of the base silica itself. Strict control over the processes employed to manufacture both the stationary phase and columns are therefore of paramount importance. Our stringent quality control measures ensure that the required column-to-column reproducibility is achieved. In the following discussion, we describe some of the quality control measures that ensure the continued quality and reproducibility associated with Thermo Scientific Hypersil BDS columns. Batch Testing Procedure Hypersil BDS columns are manufactured to the highest standards, and are rigorously quality controlled. The fully documented ISO9001:2000 control procedures for both media and column production ensure that only the highest quality columns are released to end users. Derivatization only takes place once the BDS silica has passed almost thirty (30) physical and chromatographic test specifications. Once bonded, every production lot of the BDS C18 media is tested for its chromatographic properties and for carbon load. This testing is done both prior to and after end-capping has taken place. 4

The chromatographic test compares the selectivity, efficiency and asymmetry for the range of analytes against a standard column which is prepared from a blend of up to 50 previous batches of Hypersil BDS C18 packing. The test mixture employed contains compounds such as pyridine and dimethylaniline, which are known to be sensitive to the stationary phase silanol content and can cause peak tailing and varying selectivity on many older HPLC phases. For each batch of BDS material, all selectivity parameters (k and alpha values) must be within 5% of those measured for the standard column, while efficiency parameters and asymmetry values must also meet strict specifications before it is made available for packing into columns. Figure 3 shows batch-to-batch reproducibility for the selectivity between toluene and NN Dimethyl aniline. 10.00 a 6,4 %var 5.00 0.00-5.00-10.00 Date 1/25/91 9/17/92 2/2/94 10/5/94 6/12/95 5/31/96 2/25/97 10/28/97 6/2/98 11/11/98 8/5/99 4/19/00 12/6/00 6/19/01 11/27/01 4/19/02 9/17/02 12/2/02 5/1/03 3/19/04 9/3/04 3/9/05 10/8/05 6/2/06 12/5/06 4/18/07 8/10/07 11/15/07 3/4/08 8/6/08 2/27/09 Date Figure 3: Percentage variation in selectivity (measured against a standard column) for batches of Hypersil BDS produced between 1989 and 2009 5

Column Testing Procedure Peak asymmetry and decreased column efficiency are usually observed when a column deteriorates, but may also occur if the column is poorly packed. Every Thermo Scientific Hypersil BDS column is individually tested prior to shipment to ensure the quality of the column. Figure 4 demonstrates column performance in terms of efficiency for over 15,000 Hypersil BDS C18 (250 x 4.6 mm, 5 µm) columns. The peak efficiency (measured for o-xylene) is consistently above 80,000 plates/m. Also noticeable is the trend towards higher efficiency which reflects our commitment to continually improve our column packing process. Column Efficiency 120000 100000 80000 PLates 60000 40000 20000 0 1 1001 2001 3001 4001 5001 6001 7001 8001 9001 10001 11001 12001 13001 14001 15001 Figure 4: QC data illustrating efficiency for 15000 Hypersil BDS columns 6

Bonded Phases Hypersil BDS columns are available in four bonded phases. All Hypersil BDS columns, the base deactivation procedure and endcapping process minimize peak tailing, even for basic drugs. Each Hypersil BDS column comes with a Certificate of Authenticity. Hypersil BDS C18 Columns Hypersil BDS C18 media is an excellent reversed phase material for a variety of applications and is one of the most popular packing materials available. Hypersil BDS columns are a good choice for QA/QC labs as a robust general purpose column in applications where reproducibility and long column lifetimes are required. Hypersil BDS C18 columns are applicable to a wide range of analytes including acids, bases and neutrals as shown, and are popular in methods worldwide. Ordering Information Particle size Length (mm) 4.6 mm ID 4.0 mm ID 3.0 mm ID 2.1 mm ID 2.4 µm 30 28102-034630 28102-032130 50 28102-054630 28102-052130 100 28102-104630 28102-102130 150 28102-154630 28102-152130 3 µm 30 28103-034630 28103-034030 28103-033030 28103-032130 50 28103-054630 28103-054030 28103-053030 28103-052130 100 28103-104630 28103-104030 28103-103030 28103-102130 150 28103-154630 28103-154030 28103-153030 28103-152130 5 µm 50 28105-054630 28105-054030 28105-053030 28105-052130 100 28105-104630 28105-104030 28105-103030 28105-102130 125 28105-154630 28105-154030 28105-153030 28105-152130 150 28105-204630 28105-204030 28105-203030 28105-202130 200 28105-254630 28105-254030 28105-253030 28105-252130 250 28105-304630 28105-304030 28105-303030 28105-302130 600 550 500 2 450 mau 400 350 300 250 200 150 100 50 0-50 1 1. Lidocaine 2. Methyl paraben 3. Propyl paraben 3 Column: Hypersil BDS C18 150 x 4.6 mm 5 µm Mobile phase: 30% MeCN 70% 50 mm KH 2 PO 4 ph 3.5 Flow rate: 1.0 ml/min Detection: UV @ 254nm Inj vol: 20 µl Temperature: 30 C Pressure: 92 bar 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Minutes Figure 5: Separation of lidocaine and parabens 7

Hypersil BDS C8 Columns Hypersil BDS C8 columns offer the same high quality basedeactivated, fully endcapped phase as Hypersil BDS C18, with similar selectivity but slightly less retention. They are applicable to the analysis of acids, bases and neutrals including soft drink additives as shown. Ordering Information Particle size Length (mm) 4.6 mm ID 4.0 mm ID 3.0 mm ID 2.1 mm ID 2.4 µm 30 28202-034630 28202-032130 50 28202-054630 28202-052130 100 28202-104630 28202-102130 150 28202-154630 28202-152130 3 µm 30 28203-034630 28203-034030 28203-033030 28203-032130 50 28203-054630 28203-054030 28203-053030 28203-052130 100 28203-104630 28203-104030 28203-103030 28203-102130 150 28203-154630 28203-154030 28203-153030 28203-152130 5 µm 50 28205-054630 28205-054030 28205-053030 28205-052130 100 28205-104630 28205-104030 28205-103030 28205-102130 125 28205-154630 28205-154030 28205-153030 28205-152130 150 28205-204630 28205-204030 28205-203030 28205-202130 200 28205-254630 28205-254030 28205-253030 28205-252130 250 28205-304630 28205-304030 28205-303030 28205-302130 1 3 5 8 7 6 2 4 0 5 10 Min. Column: Hypersil BDS C8, 5 µm, 250 x 4.6 mm Part Number: 28205-254630 Mobile Phase: A: 0.85% v/v H 2 SO 4 in 17.5 mm KH 2 PO 4 at ph 1.8 Flow Rate: 1.5 ml/min Detection: UV at 254 nm Sample: 1. Asorbic Acid 2. Quinine 3. Caffeine 4. Saccharin 5. Vanillin 6. Aspartame 7. Sorbic Acid 8. Benzoic Acid Figure 6: Additives in soft drinks can be readily separated using a Hypersil BDS C8 column 8

Hypersil BDS Phenyl Columns Hypersil BDS Phenyl columns offer alternative selectivity to Hypersil BDS C18 and C8 columns. It is well established that phenyl phases offer clear advantages over alkyl chains when certain types of compounds must be resolved. The exceptional stability and unique selectivity of Hypersil BDS Phenyl can be used to accomplish a difficult separation. Ordering Information Particle size Length (mm) 4.6 mm ID 4.0 mm ID 3.0 mm ID 2.1 mm ID 2.4 µm 30 28902-034630 28902-032130 50 28902-054630 28902-052130 100 28902-104630 28902-102130 150 28902-154630 28902-152130 3 µm 30 28903-034630 28903-034030 28903-033030 28903-032130 50 28903-054630 28903-054030 28903-053030 28903-052130 100 28903-104630 28903-104030 28903-103030 28903-102130 150 28903-154630 28903-154030 28903-153030 28903-152130 5 µm 50 28905-054630 28905-054030 28905-053030 28905-052130 100 28905-104630 28905-104030 28905-103030 28905-102130 125 28905-154630 28905-154030 28905-153030 28905-152130 150 28905-204630 28905-204030 28905-203030 28905-202130 200 28905-254630 28905-254030 28905-253030 28905-252130 250 28905-304630 28905-304030 28905-303030 28905-302130 1 2 3 4 5 Column: Hypersil BDS Phenyl, 5 µm, 150 x 4.6 mm Part Number: 28905-154630 Eluent: 90% 0.5M KH 2 PO 4 /10% ACN Flow Rate: 1.25 ml/min Detection: UV at 254 nm Sample: 1. Uracil 2. Procainamide 3. N-Acetyl Procainamide 4. Caffeine 5. N-Propionyl Procainamide Figure 7: Analysis of procainamides using a Hypersil BDS Phenyl column 9

Hypersil BDS Cyano Columns Hypersil BDS Cyano columns can be used in both reversed phase and normal phase chromatography. In reversed phase, they offer different selectivity compared to C18 or C8 phases. In normal phase, they are less retentive than silica columns. Ordering Information Particle size Length (mm) 4.6 mm ID 4.0 mm ID 3.0 mm ID 2.1 mm ID 2.4 µm 30 28802-034630 28802-032130 50 28802-054630 28802-052130 100 28802-104630 28802-102130 150 28802-154630 28802-152130 3 µm 30 28803-034630 28803-034030 28803-033030 28803-032130 50 28803-054630 28803-054030 28803-053030 28803-052130 100 28803-104630 28803-104030 28803-103030 28803-102130 150 28803-154630 28803-154030 28803-153030 28803-152130 5 µm 50 28805-054630 28805-054030 28805-053030 28805-052130 100 28805-104630 28805-104030 28805-103030 28805-102130 125 28805-154630 28805-154030 28805-153030 28805-152130 150 28805-204630 28805-204030 28805-203030 28805-202130 200 28805-254630 28805-254030 28805-253030 28805-252130 250 28805-304630 28805-304030 28805-303030 28805-302130 1 2 0 2 4 Min. Column: Hypersil BDS Cyano, 5 µm, 150 x 4.6 mm Part Number: 28605-154630 Eluent: 5% ACN / 95% 0.05M KH 2 PO 4 ph 3.5 Flow Rate: 1.25 ml/min Detection: UV at 254 nm Sample: 1. Morphine 2. Nalorphine Figure 8: Polar compounds (morphine and nalorphine) are retained and separated using a Hypersil BDS Cyano column 10

2.4 µm Particle Size for Faster Separations 2.4 µm particles give higher efficiency than 3 or 5 μm particles and this efficiency is delivered over a greater range of optimum linear velocity. This makes it possible to operate at higher flow rates without losing performance. Because shorter columns packed with 2.4 µm particles give equivalent efficiency to longer columns packed with 5 µm particles faster analysis and solvent savings for the chromatographer become a reality. When transferring methods to columns packed with 2.4 μm particles, the following three tips should be considered: 1) To maintain an equivalent separation when transferring a method it is important to keep the reduced linear velocity constant between the original and new method. 2) 2.4 μm-based methods are most often transferred to smaller volume columns, so the same injection volume will take up a larger proportion of the new column, possibly leading to column omeprazole or band broadening. It is therefore important to scale down the injection volume to match the change in column volume. 3) Geometrical transfer of the gradient requires calculation of the number of column volumes of mobile phase in each segment (time interval) of the gradient in the original method to ensure that the new calculated gradient takes place over the same number of column volumes, for the new column. Figure 9 illustrates method transfer to 2.4 μm particles using omeprazole as an example. The separation using the column packed with 2.4 μm particles, omeprazole elutes in 3.3 minutes, compared with 7.5 minutes for the column packed with 5 μm particles and delivers 20% more efficiency. m Volts 450 400 350 300 250 200 150 100 50 0-50 m Volts 450 400 350 300 250 200 150 100 50 0-50 0 1 2 3 4 5 6 7 8 9 10 Minutes 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Minutes Column: Hypersil BDS C8 150 x 4.6 mm 5 µm Mobile phase: 75% ACN, 25% phosphate buffer Flow rate: 1.0 ml/min Detection: UV @ 254nm Inj vol: 10 µl Temperature: 30 C Pressure: 90 bar Column: Hypersil BDS C8 100 x 4.6 mm 2.4 µm Mobile phase: 75% ACN, 25% phosphate buffer Flow rate: 0.43 ml/min Detection: UV @ 254nm Inj vol: 2 µl Temperature: 30 C Pressure: 278 bar Figure 9: Columns packed with 2.4 µm particles give faster, more efficient chromatography than columns packed with 5 µm particles 11

One advantage of using 2.4 µm particle size columns is that high speed, high efficiency separations are achievable using conventional HPLC systems, even for narrow columns. For example, the backpressure for a 100 x 2.1 mm ID column packed with 2.4 µm particles is shown in Figure 10. The optimum flow rate for this column is 0.4 0.5 ml/min, which will give a backpressure within the limits for a conventional HPLC system. We offer a convenient method transfer calculator at the Chromatography Resource Centre. www.thermo.com/columns Flow Rate vs Backpressure 100 x 2.1 mm columns in 50/50 ACN/H 2 0 Backpressure psi 8,000 7,000 6,000 5,000 4,000 3,000 2,000 1,000 2.4 µm 3 µm 5 µm 0.2 0.3 0.4 0.5 0.6 0.7 Flow Rate ml/min Figure 10: Column backpressure as a function of flow rate for 2.4, 3 and 5 µm particle packed columns There are some system considerations to remember when using short columns packed with 2.4 µm particles in order to maximise their performance. Firstly, to avoid dispersion which can lead to peak broadening, the system volume (connecting tubing ID and length, injection volume, UV detector flow cell volume) should be minimized. Secondly, because peak widths are narrower with fast chromatography, the detector time constant and sampling rate need to be carefully selected. If fast gradients are being used, then a pump with a low dwell volume is desirable to transfer the gradient to the column quickly. 12

Guard Cartridges for Column Protection Drop-in guard cartridges and holders offer convenience, economy and effective protection for extending column lifetimes. The 10 mm design offers maximum protection with minimal increase in retention. Thermo Scientific Hypersil BDS drop-in guard cartridges are provided in packs of 4 each. Ordering Information Phase Particle size Length (mm) 4.6 mm ID 4.0 mm ID 3.0 mm ID 2.1 mm ID C18 2.4 µm 10 28102-014001 28102-012101 3 µm 10 28103-014001 28103-014001 28103-013001 28103-012101 5 µm 10 28105-014001 28105-014001 28105-013001 28105-012101 C8 2.4 µm 10 28202-014001 28202-012101 3 µm 10 28203-014001 28203-014001 28203-013001 28203-012101 5 µm 10 28205-014001 28205-014001 28205-013001 28205-012101 Phenyl 2.4 µm 10 28902-014001 28902-012101 3 µm 10 28903-014001 28903-014001 28903-013001 28903-012101 5 µm 10 28905-014001 28905-014001 28905-013001 28905-012101 Cyano 2.4 µm 10 28802-014001 28802-012101 3 µm 10 28803-014001 28803-014001 28803-013001 28803-012101 5 µm 10 28805-014001 28805-014001 28805-013001 28805-012101 2.4 µm Hypersil BDS columns can also be used with modern ultra high pressure liquid chromatography (UHPLC) instruments, including the Thermo Scientific Accela High Speed LC. 13

Chromatography Columns and Consumables As the world s sole manufacturer of Thermo Scientific Hypersil silica, we have set a very high standard in HPLC and continue to maintain it with innovative new products spanning across SPE, HPLC and GC. We offer one of the broadest selections of premier chromatographic phases and innovative hardware designs available, combined with superb technical support and customer service. Whether you use HyperSep for rapid sample preparation, Hypersil BDS for routine separations or are looking for something new for your most challenging methods like Thermo Scientific Hypersil GOLD or TRACE GC columns, we have the choices to meet your needs. Chromatography Resources Our bi-monthly Separated by Experience newsletter keeps you up-to-date on the latest technical and product information of interest to chromatographers. Subscribe today! www.thermo.com/columns Our Chromatography Columns and Consumables catalog helps you find all your chromatography needs in a single resource. To order your copy visit thermo.com/catalog 2009 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. USA and Canada Tel: +1 800 532 4752 Fax: +1 561 688 8731 analyze.us@thermo.com United Kingdom Tel: +44 (0) 845 702 3964 Fax: +44 (0) 1707 391 311 enquiries@chromacol.com, France Tel: +33 (0) 1 60 92 48 00 Fax: +33 (0) 1 60 92 49 00 analyze.fr@thermo.com, Germany Tel: +49 (0) 6103 408 1140 Fax: +49 (0) 6103 408 1111 analyze.de@thermo.com Japan Tel: +81 45 453 9220 Fax: +81 45 453 9222 analyze.jp@thermo.com, India Toll free: 1800 22 8374 Tel: +91 22 67162200 Fax: +91 22 67162244 contact.lpg.in@thermofisher.com, Switzerland Tel: +41 56 618 41 11 Fax: +41 56 618 41 41 info.ch@thermofisher.com www.thermo.com/columns BRGSCHYPBDS0609