DEVELOPMENT OF AN EFFECTIVE STRATEGY FOR SULFIDE CONTROL IN SEWERS USING FREE NITROUS ACID

Similar documents
SAFETY DATA SHEET Cutan Luxury Shampoo, Conditioner & Bodywash

MATERIAL SAFETY DATA SHEET

Emergency telephone NSW Poisons Information Centre Contact New Zealand call

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET TAMPUR 100

Material Safety Data Sheet

ESM and disposal of PCBs

SAFETY DATA SHEETS. Version: 2 Issued: 13 th May 2013 Page 1 of 7

Marks & Spencer Homecare Products Ingredients and Safety Data Sheet

Appendix 20 Assessment of Beca s Report on Solid Settling Options

HyProBlack Hexavalent chrome free RoHS and ELV compliant. HyPro System

1. SUBSTANCE IDENTIFICATION/ PREPARATION AND COMPANY DETAILS. Concentrated Multi-Purpose Liquid Cleaner

Eco Clear Shield - Polycarbonate

Material Safety Data Sheet

ETON IRRIGATOR ADVISORY COMMITTEE

GROW BETTER NATIVE POTTING MIX

DATA SHEET N O 088 O.E.S. / M.E.L.

1. Identification of the substance/mixture and of the company/undertaking

Chemical CAS No. EINECS Registration % Classification Classification No. Number Conc 1999/45/EC 1272/2008

Safety Data Sheet 1907/2006/EC, 1272/2008/EC

MATERIAL SAFETY DATA SHEET

PPH CERKAMED Safety Data Sheet - CHLORAXID 5,25% GEL

Abbey Animal Health Pty Ltd Material Safety Data Sheet

1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING

POOL SYSTEMS PO Box 5225 BRENDALE QLD 4500

IODOSORB MSDS No. 173

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

NON-Hazardous Chemical, NON-Dangerous Goods

Material Safety Data Sheet

Material Safety data sheet

Flex Crax Safety Data Sheet

(50mg, 100mg, 150mg & 200mg Sustained Release Tablets)

SAFETY DATA SHEET Zinc Chloride Page 1 Issued: 11/11/2012 Revision No: 1

RATSAK 1 SHOT RAT & MOUSE BLOCKS

Dear Valued Customer,

Section 1 Identification of Material and Supplier

Q Can a local government elect to cease fluoridating communities that are currently fluoridated?

One of Diabetes Queensland key strategies to improve lives is through research.

SAFETY DATA SHEET. Thermal, acoustic insulation. Address: 1809 Lytton Road, Lytton, Queensland Phone: (07) Fax: (07)

USE OF ILLICIT DRUGS AND OTHER PROHIBITED SUBSTANCES BY STUDENTS

REPORT ON LAWS AND RECOMMENDATIONS ON DENTAL MERCURY MANAGEMENT IN THE EU

MATERIAL SAFETY DATA SHEETS

SibEnzyme Ltd. 1. IDENTIFICATION OF THE PREPARATION/SUBSTANCE AND OF THE COMPANY

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. Material for temporary filling and rebuilding root canals

HIGHLANDS COMMUNITY DEVELOPMENT DISTRICT

CMT GROUT/CMT GROUT HITHIX. Monolithic support system grout (ALL HOURS)

MATERIAL SAFETY DATA SHEET TAMPUR 130

RINSE ALL. Restrictions on Use None known. Manufacturer Esteam Mfg Ltd, th NE, Calgary, Alberta, T2E6V2, , esteam.

Material Safety Data Sheet

Instant Hand Sanitising Gel

Bio Cleaning Solutions

Material Safety Data Sheet

Safety data sheet according to 1907/2006/EC, Article 31

DARENT WAX COMPANY LIMITED SAFETY DATA SHEET

Material Safety Data Sheet

Not applicable (5g), (15g) 63 Poplar Road, Parkville, Victoria 3052, Australia (24hr)

Bait for the control of mice in domestic situations (ALL HOURS)

HYDROGEN PEROXIDE AND PERACETIC ACID

NOT CLASSIFIED AS HAZARDOUS ACCORDING TO CRITERIA OF WORKSAFE AUSTRALIA

MATERIAL SAFETY DATA SHEET

Primacor Injection Milrinone Lactate

Fellowes UK Yorkshire Way, West Moor Park Doncaster, South Yorkshire DN3 3FB UK Telephone: + 44 (0) Fax: + 44 (0)

Safety Data Sheet. : CD/DVD Scratch Repair Kit. : Yorkshire Way, West Moor Park Doncaster, South Yorkshire DN3 3FB UK

Safety Data Sheet. SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product Identifier

ADT Booster TM (5 x 0.5mL syringe) 63 Poplar Road, Parkville, Victoria 3052, Australia (24hr)

MATERIAL SAFETY DATA SHEET

: ISOPON WINDSCREEN RESIN (WSR-R-AU)

Safety Data Sheet WOOL WASH

SAFETY DATA SHEET BAL CEMENT BASED GROUTS

MATERIAL SAFETY DATA SHEET

Waterless urinals Choosing the appropriate model for your business

Safety Data Sheet Avesta Classic Pickling Paste 101

Tramal. (50mg Capsules)

Safety Data Sheet Brigand SB

SAFETY DATA SHEET BWT-27

Greer's Peroxide Cleaner

Rapid Set Sand and Cement

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET WILKINSONS GROUT CLEANER

SAFETY DATA SHEET LAUNDRY LIQUID CLASSIC 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER 2. HAZARDS IDENTIFICATION

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET BLACK LIQUOR 1. PRODUCT AND COMPANY IDENTIFICATION

MATERIAL SAFETY DATA SHEET

Page 1 of 5. Date of Issue: 13 th September 2016 Soft Serve Machine Cleaner

2.2. Label elements There are no statutory labelling requirements under Directive 1999/45/EC, regulation 1272/2008 and regulation 453/2012.

Sodium Bromide, Liquid Sodium Bromide

SAFETY DATA SHEET Diamond Powder

Road Marking Waterborne Primer/Sealer

NON-Hazardous Substance, NON-Dangerous Goods

Pet owners are often very anxious about veterinary procedures that involve anesthesia. This handout attempts to alleviate some of these concerns.

Amalgam Containment and Recycling: Attaining Zero Mercury Discharge in Dental Office Wastewater

Safety Data Sheet. Single component polyurethane foam with propellant Fire protection of linear joints and around service penetrations

PRODUCT NAME POLYESTER BASECOAT

MATERIAL SAFETY DATA SHEET KAPA2G Robust HotStart ReadyMix PCR Kits

Material Safety Data Sheet According to EU Regulation 1907/2006

UltraCarb (Stearate Coated)

Transcription:

DEVELOPMENT OF AN EFFECTIVE STRATEGY FOR SULFIDE CONTROL IN SEWERS USING FREE NITROUS ACID Howard Leemon 1, David Fillmore 2, Anthony Keating 1, Guangming Jiang 3, Sandeep Sarathy 1, Zhiguo Yuan 3 1. Cloevis Pty Ltd, St Lucia, QLD, Australia 2. Unitywater, Morayfield, QLD, Australia 3. Advanced Water Management Centre, The University of Queensland, Brisbane, QLD, Australia ABSTRACT Free nitrous acid (FNA) was dosed into a rising main 840 m long, 150 mm diameter, with an average flow rate of 202 kl per day and an average retention time of 2 hours, to control the formation of sulphide within the rising main where sulphide control was challenging. It was found that weekly doses of FNA for 6 hours could provide sustained control of downstream sulphide at an estimated chemical cost of $19 to $27 per ML of wastewater treated (averaged over the total flow for a week). INTRODUCTION Field trials at the City of Gold Coast of a novel technology for sulfide control have been reported previously (Jiang et al., 2013). Here we report the results of field trials conducted at Scarborough in Queensland by Cloevis Pty Ltd, Unitywater and the Advanced Water Management Centre (AWMC) at The University of Queensland (UQ) for the purpose of demonstrating the effectiveness of the Cloevis process in controlling sulfide production in a rising main where an alternative method of control by dosing magnesium hydroxide was not sufficiently effective. The conditions for the trial were challenging. Without any chemical control, weekly hydrogen sulfide readings have on occasions averaged more than 100 ppm with a 90 th percentile reading in excess of 250 ppm have been recorded in the rising main discharge manhole. The system wide target across the Unitywater system is a 90 th percentile of 10 ppm. Dosing with magnesium hydroxide (MHL) had brought about significant reductions in the recorded hydrogen sulfide levels but they were still well above the target level. Sulfide generation at this site is impacted strongly by trade waste that is injected in an irregular manner directly into the rising main between the wet well and the discharge manhole. The sewage collection system in this part of Unitywater s network is sub-optimal. Changes to the infrastructure will be expensive and difficult to implement. Unitywater closely monitors the trade waste in this catchment and has effected incremental improvements. Chemical dosing is currently seen as the most acceptable strategy to control the odour and corrosion potential in this catchment. Chemical dosing where the trade waste enters Unitywater s network is not possible so the upstream pumping station (SPS-RED001) was chosen as the dosing site. For Cloevis Pty Ltd, the objectives of the trial were to demonstrate that sulphide control using intermittent dosing with FNA could be achieved for this challenging location, to establish appropriate operating parameters for the dosing, to further refine the technology and to determine the likely chemical costs associated with this

novel control strategy. For Unitywater, the purpose of the trial was to see if dosing with FNA offered a better solution than dosing with MHL. THE CLOEVIS PROCESS The Cloevis process was developed by researchers at the AWMC during the SCORe project. It works in a very different manner to the continuous dosing control methods that aim to prevent the release of sulphide into the gas phase well downstream from the locations where it is formed. FNA is dosed into upstream rising mains on a regular but intermittent basis to prevent the formation of sulphide at its source, thereby reducing or removing the need for downstream control measures. METHODOLOGY The rising main The wet well (SPS-RED001) used for this trial is located in Jamieson Park at Scarborough in Queensland. Figure 1 provides a schematic layout of the rising main. The average daily flow of domestic wastewater into the wet well is 202 kl. The pumps are rated at 26 L/s. During the course of the trial the set points for the wet well gave an average pump frequency of 50 cycles per day with each pump cycle delivering about 4.0 kl into the rising main. The rising main has a diameter of 150 mm and length approximately 840 m to the discharge manhole. Trade waste is also being discharged directly into the rising main at 4 separate locations. The flow at the discharge manhole enters a turbulent phase rendering control by ph elevation extremely difficult. Figure 1: Schematic layout of the rising main system

Dosing In the previous trials (Jiang et al., 2013) hydrogen peroxide had been used in conjunction with FNA to improve the performance of the dosing. In these trials, FNA alone was used to test the effectiveness of a less complex mix. FNA was formed in the wet well by dosing liquid sodium nitrite (40%) and hydrochloric acid (35%) simultaneously below the water level in the wet well in order to optimise mixing while the wet well was refilling after the completion of each pump cycle. It should be noted that the transport and storage of chemicals is regulated by the Australian Code for the Transport of Dangerous Goods by Road & Rail (National Transport Commission, 2014). Appropriate safety measures for handling and storage were put in place to comply with the requirements of the code. The target level for nitrite in the rising main was 100 mgn/l of wastewater. The quantity to be dosed during each pump cycle to achieve this target was calculated using an additional 50% safety factor to allow for variability in the flows arising from the trade waste sources. The target ph in the rising main was less than or equal to 6.0. Extensive sampling from the wet well was carried out initially to establish the required quantity of hydrochloric acid to be dosed during each pump cycle to achieve this target. Using the observed periods for the recovery in the sulfide levels over the first few trials, it was decided that the most appropriate gap between trials to optimise costs and operational efficiency was approximately 7 days. The duration of dosing was varied between trials in order to determine the lower limits for effective control. Sulfide measurements Hydrogen sulfide levels in the discharge manhole were measured using Odalog gas data loggers providing a reading every minute. As a precaution, 2 loggers were used at all times to ensure consistency in the readings. Rain events No significant rain events were recorded during any of the dosing periods. RESULTS AND DISCUSSION To demonstrate the effects of no dosing, dosing with MHL and dosing with FNA, the sulfide readings for 3 weeks that are representative of the results obtained by each of these are shown in Figure 2. The key measures of average sulfide, 90 th percentile and maximum sulfide for each of these are compared in Table 1.

Figure 2(a). Sulfide readings without dosing Figure 2(b). Sulfide readings with MHL dosing Figure 2(c). Sulfide readings with FNA dosing for 6 hours on 08/09/2014

Table 1: Comparison of key parameters for each representative week following FNA dosing 7 day average sulfide readings 7 day 90th percentile sulfide readings 7 day maximum sulfide readings (a) No dosing 129 305 1023 (b) MHL dosing 21 47 529 (c) FNA dosing 4 12 177 The extremely high sulfide readings with no dosing being applied are significantly reduced by dosing with MHL. However, the MHL dosing, at that dosing rate, did not achieve sufficient reduction to meet the target of the 90 th percentile being 10 ppm. FNA dosing was able to achieve a further significant reduction over the MHL dosing. It should be noted that there would have been some differences in the temperatures of the wastewater between those for cases (a) and (b) and those for case (c) because of the time of year in which the trials were conducted. However, the temperature difference alone does not explain the significant reduction in sulfide measurements after FNA dosing. For FNA dosing the characteristic behaviour for each trial different from other methods in that dosing results in an immediate reduction of the recorded hydrogen sulfide levels or maintains an existing low level, after which the sulfide levels slowly begin to recover. An initial dose for 24 hours prepares the rising main for the subsequent shorter weekly maintenance doses. Various durations were tested before we settled on 6 hours as the minimum effective dose for this site. The detailed results of the FNA dosing trials are presented in Table 2. Table 2: Average, 90 th percentile and maximum sulphide readings for 7 days after FNA dosing Trial # Dose duration (hrs) 7 day average sulfide readings 7 day 90th percentile sulfide readings 1 24 3 8 2 11 4 9 3 11 5 12 4 8 4 9 5 7 4 12 6 5 7 16 7 6 7 21 8 7 9 23 9 6 15 35 10 6 15 35

In estimating the cost of FNA treatment, here we consider only the cost of chemicals. The capital and set up costs of the dosing infrastructure and chemical delivery costs are likely to be similar to other chemical dosing installations while the labour costs are likely to be similar or somewhat reduced given the intermittent dosing strategy. For a weekly dosing strategy, we estimate that the cost of chemicals will lie in the range of $19 to $27 per ML of wastewater treated when the cost is averaged over the total flow for the week. CONCLUSION Effective control of sulfide production in a rising main by weekly dosing with FNA was demonstrated over multiple trials with 6 hours as the minimum dosing duration for this challenging site where the sulfide level is impacted strongly by trade waste. Hydrogen peroxide was not used in these trials, thereby simplifying the chemical handling and dosing. It is likely that treatment with FNA will provide a cost effective alternative to other sulfide control methods when applied to upstream rising mains. CLOEVIS PTY LTD The method of controlling sulfide in sewers using FNA, with and without hydrogent peroxide, has been protected by patent applications and has been licensed for commercialisation worldwide to Cloevis Pty Ltd. Cloevis is working in partnerships with US Peroxide LLC which is conducting trials of the Cloevis technology in USA. ACKNOWLEDGEMENTS The authors acknowledge the essential contributions made by Unitywater in providing the site and support for this trial, US Peroxide LLC for the supply and installation of the dosing equipment and The University of Queensland and UniQuest Pty Limited for providing personnel and operational support. REFERENCES Jiang, Guangming, Keating, Anthony, Corrie, Shaun, O'Halloran, Kelly, Lam Nguyen and Yuan, Zhiguo (2013) Dosing free nitrous acid for sulfide control in sewers: results of field trials in Australia. Water Research, 47 13: 4331-4339 National Transport Commission (2014), Australian Code for the Transport of Dangerous Goods by Road & Rail, Edition 7.3 (www.ntc.gov.au)