Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

Similar documents
Flexural Strength of Three Denture Base Materials in Different Curing Procedures

AN INJECTION MOULDING DEVICE, IMPROVING THE EXISTING INJECTION SYSTEM FOR ACRYLIC DENTURE FABRICATION

Journal of IMAB - Annual Proceeding (Scientific Papers) 2016, vol. 22, issue 3

Modification of curing technique of a self cure injection molding acrylic resin: Effect on residual monomer

An evaluation of the hardness of flexible Denture Base Resins

ISO 1567 INTERNATIONAL STANDARD. Dentistry Denture base polymers. Art dentaire Polymères pour base de prothèses dentaires. Third edition

Effect of Thickness and Recycling on Transverse Strength of Relined Acrylic Resin Denture

A comparison of three dimensional change in maxillary complete dentures between conventional heat polymerizing and microwave polymerizing techniques

International J. of Healthcare and Biomedical Research, Volume: 04, Issue: 01, October 2015, Pages 17-25

The dimensional distortion of acrylic resin denture bases subjected to different dual cure materials and methods Dr MG Thokoane

TECHNICAL DATASHEET POUR TYPE ACRYLIC RESIN PDFTPT-082

Relining and Rebasing of complete denture

ISO INTERNATIONAL STANDARD. Dentistry Base polymers Part 1: Denture base polymers

The bond between acrylic resin denture teeth and the denture base: recommendations for best practice D.R.Radford 1, A.S.Juszczyk 2, R.K.F.Clark 3.

Bending strengths and hardness of autopolymerized acrylic resin

CERTIFICATE OF APPROVAL

Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

The Effect of Using Modified Flask on the Porosity of Processed Heat- Cure Acrylic Resin

"Artless solution to resolve the problem of retention in resorbed alveolar ridge cases"

Bond strength test of acrylic artificial teeth with prosthetic base

Original Research. Absorption of soft lining materials Kumar SK et al

RELINING AND REBASING

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Handling efficiency of autopolymerized resin applied using the brush-on technique

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

SOLUBILITY OF DIFFERENT SOFT LINING MATERIALS IN DISTILLED WATER, ARTIFICIAL SALIVA AND DENTURE DISINFECTANT SOLUTION

Research Article Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures

An Obturator With A Soft Touch: A Case Report

A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study

Evaluation of bond to Enigma High Impact Denture Base

Ivocap The successful technique

/jp-journals Evaluation of Impact Strength of Conventionally Heat Cured and High Impact Heat Cured Poly Methyl

Product Information. Meliodent The solution for every denture Effective material from a proven partner. Giving a hand to oral health.

Comparison of Flexural Strength of two Provisional Materials Used In Fixed Prosthodontics -An in Vitro Study.

FRACTURE STRENGTH OF PALATAL DENTURE BASE CONSTRUCTED FROM DIFFERENT ACRYLIC DENTURE BASE MATERIALS

1. RPD Acrylic portions = denture teeth (DT), denture base (DB) (and veneering)

Artic Posteriors 30 U 30 L 32 U 32 L 30 U 30 L 32 U 32 L 30 U 30 L 32 U 32 L. Jump to Product Item Numbers

The influence of different ph of saliva and thermal cycling on the adaptation of different denture base materials

Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth

CASE REPORT ABSTRACT INTRODUCTION. AIMS AND OBJECTIVES Aims

Rehabilitation of Resorbed Mandibular Ridge with Implant Supported Overdenture- A Clinical Report

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

Processing-induced Tooth Displacement and Occlusal Changes in Complete Dentures An Overview

UDELL DENTAL LABORATORY Instructions for Use

Element-Z Screw-Retained Hybrid

Triad Visible Light Cure System

Effect of Different Dental Materials on the Surface. Roughness of Acrylic Resin ( A comparative in vitro study )

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

An Alternative Approach for Fabrication of a Hollow Maxillary Complete Denture: A Case Report

A comparative study on the accuracies of resin denture bases and metal denture bases

Prof. Dr. Hikmat J. Al-Judy B.D.S., M.Sc., Ph.D in Prosthodontic, College of Dentistry/ Baghdad University/ Baghdad, Iraq.

J Korean Acad Prosthodont : Volume 45, Number 6, 2007

J Bagh College Dentistry Vol. 25(2), June 2013 Effects of time delay

INDIAN DENTAL JOURNAL

The full veneer crown is one of the most important

The effect of glass flakes reinforcement on the surface hardness and surface roughness of heat-cured poly (methyl methacrylate) denture base material

Comparative Evaluation of the Accuracy and Dimensional Stability of Three Interocclusal Recording Materials- An In Vitro Study

Opacity and Color Changes of Light-Cured Ideal Makoo (IDM)

The Effect of Outdoor Weathering on Color Stability of Silicone and Acrylic Resin, Pigments A Comparative Evaluation: An in vitro Study

THE LEVEL OF RESIDUAL MONOMER IN INJECTION MOLDED DENTURE BASE MATERIALS

Transverse Strength of Reinforced Denture Base Resin with Metal Wire and E-Glass Fibers

1. Introduction Technical data In-vitro investigations with Systemp.link Clinical assessment Biocompatibility...

Double-casting method for fixed prosthodontics with functionally generated path

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

AvaDent Bonding Procedure Results: The AvaDent bond exceeds ADA requirements.

Gingiva Solution SR Phonares II, IvoBase, SR Nexco

Dr Ziad N. Al-Dwairi. Supervisors at the Dental Technology Lab. Assistant(s)

RPD ACRYLIC MATERIALS

ident CT Guide Protocol

UnBreakable. Arian Deutsch, CDT

Original Article MATERIALS AND METHODS INTRODUCTION

DLT 211 ADVANCED COMPLETE DENTURES

It s more than a denture, It s a smile. IVOCLAR VIVADENT REMOVABLE. More than dentures. Tooth Line Portfolio

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

Frequent use for the preparation of prosthetic products

ISSN X (Print) Research Article. *Corresponding author Dr. Hemal Agrawal

Comparison between Acetal Resin and Cobalt-Chromium. Removable Partial Denture Clasp Retention: An in vitro Study.

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on /jp-journals

The Fracture Pattern of Different Mandibular Over Denture Designs.

Palatal Vault Depth Influence on the Flexural Strength of Two Heat Cure Acrylic Denture Base Resins: An in vitro Study

J Bagh College Dentistry Vol. 21(1), 2009 The effect of using different..

Nagri D et al. Linear occlusion and Neutral Zone recording for severely resorbed ridges

ZEST DANVILLE MATERIALS PERIOSCOPY

Prosthetic V. Removable dentures I.

PROSTHODONTIC REHABILITATION OF A SEVERELY RESORBED MANDIBULAR RIDGE USING NEUTRAL ZONE TECHNIQUE: A CASE REPORT

Incisal Edge Abrasion Caused By An Unusual Eating Habit

Making the Unstable Stable-A Case Series of Management of the Flabby Ridge

The success of implant reconstruction depends

A comparative evaluation of three different techniques for single step border molding

Flexural Strength of Poly Propylene Fiber Reinforced PMMA

Articulators. 5- Wax up and refining the occlusion for dental restorations.


DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

lec: Dental material dr. Aseel Mohammed Filling material

PROSTHETICREHABILITATION OFAHEMIMANDIBULECTOMY PATIENTWITHTWINOCCLUSION

Evaluation of the Effect of Temperature Changes on the Dimensional Stability of poly (Vinyl Siloxane) Impression Material.

Prosthodontic Management of Combination Syndrome Case with Metal Reinforced Maxillary Complete Denture and Mandibular Teeth supported Overdenture

An Evaluation on the Flexural Strength of Heat Cure Polymethyl methacrylate Denture Base Resin with and without Reinforcement of Polyethylene Fiber

Transcription:

Dental Journal Mahidol Dental Journal Original Article Dimensional stability of compression and injection molding denture bases in long and short curing procedures Noppavan Nagaviroj, Krantarat Wanitchanont, Widchaya Kanchanavasita, Amornrat Wonglamsam Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand Abstract Objectives: To compare the linear dimensional change of compression molding (Probase Hot and SR Triplex Hot) and injection molding (SR Ivocap High Impact) denture base materials subjected to long and short curing procedures. Materials and methods: Six disc-shaped specimens (40 mm in diameter, 3 mm in thickness) of each material were polymerized in long and short curing procedures according to manufacturer s instructions. The dimensional change of the disc was measured in two perpendicular directions immediately after processing, 24 hours and 48 hours after processing using a measuring microscope. Statistical analyses were performed by three-way ANOVA (α=0.05) and simple effects analysis because of the interaction among 3 independent variables (materials, curing procedures and time after processing). Results: There was a significant difference in dimensional change among materials. The dimensional change of SR Ivocap High Impact was the least, especially with the long curing procedure (p<0.05). Significantly less dimensional change occurred when SR Ivocap High Impact was cured in a longer period of time (0.02-0.023%). The dimensional change of compression molding (Probase Hot and SR Triplex Hot) occurred more at 48 hours after processing (0.05-0.13%) than at 24 hours after processing (0.03-0.05%). Conclusions: Dimensional change of the injection molding material after processing was less than the compression molding material. The curing procedures had an effect on the dimensional accuracy of the injection molding material, i.e. long curing procedure provided less dimensional change. Keywords: dimensional stability, denture base materials, compression molding, injection molding, polymerization shrinkage How to cite: Nagaviroj N, Wnaitchanont K, Kanchanavasita W, Wonglamsam A. Dimensional stability of compression and injection molding denture bases in long and short curing procedures. M Dent J 2016; 36: 155-163. Corresponding author: Noppavan Nagaviroj Department of Prothodontics, Faculty of dentistry, Mahidol University 6 Yothi Street, Rajthevi. Bangkok, 10400, Thailand. Received: 15 February 2016 Accepted: 26 February 2016 155

Introduction Most of denture bases are fabricated from acrylic resins, which have been used in dentistry and mostly used in prosthodontics, especially for removable prostheses such as complete denture or partial denture. 1 Acrylic resins and their curing methods have been developed and used for fabricating denture bases in a variety of ways. 2 There are many advantages of using acrylic resins to construct a denture such as their acceptable color appearance which matches the oral soft tissue, adequate strength and ease of repair. 1-2 The proper fabrication process is important for achieving optimum properties of the material resulting in the favorable prostheses. A dimensional stability is the special concern in the mechanical properties 3 which provides the well-fitting denture base that adapts to the palate and produces the border seal to the peripheral tissue. This can improve the patient satisfaction. 1 Despite the several processing methods attempting to decrease the polymerization shrinkage, the inaccuracies of a denture base material including dimensional change can happen during and after processing. 1,3 When fabricating maxillary complete dentures from acrylic resin, polymerization shrinkage can occur depending on the material properties and processing techniques. The posterior palatal gap may not be sealed and the vertical dimension may be changed, as a result of the dimensional change. This condition can lead to an inaccurate fit of supporting structure, poor retention, and inadequate occlusal function. 4 To decrease the dimensional change from polymerization shrinkage in the compression molding technique, the injecting molding technique has been developed. By using this technique, the unpolymerized acrylic resin can be controlled to a specific molding design which helps compensate a polymerization shrinkage. Anderson et al. 5 reported that the injection molding could improve dimensional stability when compared to the compression molding techniques. Due to the popularity of the injection molding technique, many manufacturers have provided an acrylic resin using this technique. In a denture construction process, we commonly use the conventional curing technique which is divided into two methods, short and long curing methods. The differences between the two methods are the boiling temperature and curing duration which may affect the properties of the denture. The long curing method produces the most dimensionally stable denture while the short curing method produces quick, cheap and less energy consumption procedure. 1-3 The purpose of this study was to compare the dimensional stability of acrylic resin using different processing techniques and polymerization cycle. Materials and methods Three brands of commercial denture base materials were selected: Probase Hot and SR Triplex Hot (compression molding) and SR Ivocap High Impact (injection molding) (Table 1). Circular stainless steel mold (40 mm in diameter and 3 mm in thickness; with 1 mm in depth of two crossing triangular grooves at the bottom of the mold) was used to fabricate specimens. The two grooves created two crossing projections, with two reference points 30 mm apart, in the cured specimens (Figure 1 and Figure 2). The molds were invested in the Hanau flasks (Figure 3) and flasked for injection molding techniques (Figure 4) using dental stone type III. Six specimens were prepared from six separate mixes for each group. The compression and injection process of the specimens, using long curing method and short curing method, were carried out following the manufacturers instruction of each material (Table 2). 156

Table 1 Composition of commercial denture base materials Brand of denture base materials Powder ProBase HOT -Polymethyl methacrylate > 95% -Dibenzoyl peroxide 2.5% -Softening agent -Pigments SR Triplex Hot -Polymethyl methacrylate > 95% -Benzoyl peroxide 0.5-1.5 % -Pigments and catalysts SR Ivocap High Impact -Polymethyl methacrylate -Dibenzoyl peroxide -Copolymer and pigments -Pigments Monomer -Methyl methacrylate 25-100% -Ethylene dimethacrylate 1-<10% -Catalyst -Methyl methacrylate 50-100% -Ethylene dimethacrylate 3-<10% -Methyl methacrylate 50-100% -Ethylene dimethacrylate 3-<10% -Copolymer Figure 1 Circular stainless mold. (40 mm in diameter, 3 mm in thickness with 2 crossing triangular grooves) Figure 2 The specimen after removal from the mold showing two crossing triangular projections with reference points Figure 3 Circular stainless steel mold invested in Hanau flask 157

Figure 4 Circular stainless steel mold invested in flask for injection molding techniques Table 2 Curing methods according to the manufacturer s sheet. Brand Processing P:L Ratio Mixing Working Procedure (g:ml) time time Probase Heat-cured Hot compression (longcured) molding Curing Curing method according to Procedure manufacturer s sheet 22.5:10 10 min 20 min Long Heat-polymerization in cold water, heat up to 100 C and let boil for 45 min. Heat-polymerization in boiling water 100 C for 40 min. SR Triplex Hot (longcured) SR Ivocap (longcured) Heat-cured compression molding Heat-cured injection molding 23.4:10 10 min 20 min Long Heat-polymerization in cold water, heat up to 100 C and let boil for 45 min. Heat-polymerization in boiling water 100 C for 20 min. 20:30 5 min 10 min Long Using the Ivocap flask starts to boil for 90 min. during entire polymerization Using the Ivocap flask starts to boil for 35 min. during entire polymerization 158

The linear dimensional change of the specimens was determined by the changes in the distance between the reference points. The measurements were made after deflasking, and at 24 hours and at 48 hours using a measuring microscope. The normality test of the data was carried out using the Shapiro-Wilk test, while the test for homogeneity of variances was carried out using Levene s test in SPSS for Windows (version 16). The percentage linear dimensional changes were analyzed by three-way analysis of variances (ANOVA), the 3 independent variables were material brand, processing time and time after processing. The simple effects analysis was used when there was an interaction among these. All statistical tests were performed at α=0.05. Results The mean values and standard deviations of the percentage linear dimensional changes are shown in Table 3. From three-way ANOVA (Table 4), a significant interaction between materials and curing procedures, as well as, between materials and times were observed. Table 3 Mean and standard deviation of percentage linear dimensional changes after 24 and 48 hours from the initial distance (n=12) Materials Curing procedures % Linear Dimensional Changes at times after processing Mean±SD 24 hours 48 hours Probase Hot Long -0.030±0.005-0.030±0.005-0.051±0.006-0.052±0.003 SR Triplex Hot Long -0.052±0.007-0.131±0.009 SR Ivocap High Impact Long -0.050±0.005-0.020±0.003-0.037±0.004-0.133±0.010-0.023±0.002-0.047±0.003 Table 4 Tests of between Subjects Effects (three-way ANOVA) Source Type III Sum of Squares df Mean Square F p-value Materials.098 2.049 1.434E3 <.05 Curing procedure.002 1.002 49.929 <.05 Time.048 1.048 1.389E3 <.05 Materials * curing procedure.003 2.002 46.088 <.05 materials * time.037 2.019 547.324 <.05 Curing procedure * time.000 1.000 3.536.062 materials * curing procedure * time 5.704E-5 2 2.852E-5.834.437 *Statistical significance at α = 0.05 159

The percentage linear dimensional changes in all materials were statistically significant difference in both curing procedures and times. Linear dimensional changes of SR Triplex Hot showed the highest value in both long and short curing procedures at 24 and 48 hours after processing, while SR Ivocap High Impact showed the lowest value of linear dimensional changes. Significantly less dimensional changes occurred when SR Ivocap High Impact was cured longer (Figure 5 and Figure 6). Figure 5 Estimated marginal means of linear dimensional changes of the three materials between long and short curing procedures at 24 hours after processing Figure 6 Estimated marginal means of linear dimensional changes of the three materials between long and short curing procedures at 48 hours after processing 160

Linear dimensional changes of Probase Hot and SR Triplex Hot demonstrated statistically significant difference between 24 hours from initial distance and 48 hours from initial distance in both curing procedures. Only SR Ivocap cured by short curing procedures showed statistically significant difference between 24 hours from initial distance and 48 hours from initial distance. SR Ivocap High Impact cured by long curing procedures did not show any differences between 24 and 48 hours from initial distances (Figure 7 and Figure 8). Figure 7 Estimated marginal means of linear dimensional changes of the three materials in long curing procedure between 24 and 48 hours after processing Figure 8 Estimated marginal means of linear dimensional changes of the three materials in short curing procedure between 24 and 48 hours after processing 161

Discussion The dimensional change of an acrylic denture base material can be examined using various methods, such as measuring vertical dimension, measuring pin point opening in articulator and measuring linear dimensional change. In this experiment, the stainless steel mold directly invested in the flask was used. The specimens were disc-like with controlled thickness to permit a measurement of the dimensional change of the specimens, resulting from polymerization. The absence of denture teeth and different denture base thickness were the condition to avoid dimensional distortion of acrylic specimens. The two acrylic resins fabricated by compression molding technique, Probase Hot and SR Triplex Hot showed different degrees of shrinkage that could arise from the difference in composition of the material. The manufacturer claimed that the Probase Hot formula was developed but all of the compositions have not yet been clearly stated. The injection molding materials, SR Ivocap High Impact, showed less shrinkage than that of the compression molding materials. In a previous study, complete dentures processed by SR Ivocap system provided minimal processing error in dimensional stability. The mean increase in vertical dimension for the injection method was 0.001±0.003 inch. 6 Anderson et al. 5 reported that the injection molding can improve dimensional stability compared with the compression molding techniques. This polymerization shrinkage measured within 24 hours of processing range from 0.35% to 0.78% for the injection process. Nogueira et al. 7 concluded that the injection molding techniques produced a significantly smaller incisial pin opening, more accuracy, reduced vertical changes and decreased occlusal adjustment in laboratory over the compression molding techniques. It can be explained by the compensation of polymerization shrinkage due to the pressure applied by injection of the resin. The resin was injected to the mold and was pressured for 5 minutes before placing in the boiling water. During the curing process, the pressure was maintained and the polymerization shrinkage was compensated to a certain extent from a reservoir of the non-polymerized material from the sprue. Another advantage of the injection molding techniques is less measuring error according to well-prepared capsule package of monomer and polymer. Stanford and Paffenbarger 8 investigated that long curing procedures could produce more dimensional accuracy of dentures than short curing procedures. In this study, the specimens that were cured by compression molding techniques produced the same level of dimensional change between long curing and short curing procedures. Bhanodaya et al. 10 conclude that the cooling process was believed to be the cause of residual stress and distortion from induced strain. The rate of cooling of the flask after processing has an effect on the dimensional changes of acrylic resin more than the rate of heat application. 10 By the way, curing procedures affected the SR Ivocap High Impact injection molding that long curing procedures could provide more dimensional accuracy than short curing procedures because of the longer boiling time and duration of pressure application, and the higher degree of monomer conversion. A polymerization reaction is never 100% complete as not all monomer is able to react completely. 9 Thus, vary amounts of free monomer still exist in the polymerized denture known as residual monomer. 1-2 After polymerization, there is less than 1% residual monomer presented in heat-cured acrylic resin. It is temporarily trapped in the polymer network and dimensional change can 162

occur until the monomer leaches out which can take few minutes, several days, or several weeks. 1-2 For both 24 and 48 hours after processing, residual monomer also exists. 9 The difference is amount of leaching out monomers. For the 48 hours after processing, less monomer presented as it continued leaching when the time passed by. 9 In this research, we focused on the simple disc-like specimens. In clinical situation, however, other factors to be concerned are size, shape, thickness and the presence of artificial teeth and distortion when the denture is deflasked that influences the dimensional stability of complete denture. These should be taken into account for determinate of dimensional stability of complete denture. The conclusions are as follows : 1. The injection molding techniques provided more dimensional accuracy than compression molding techniques. 2. The curing procedures affected SR Ivocap High Impact material; long curing procedures provided more dimensional accuracy. 3. No statistically significant differences in long and short curing procedures in compression molding technique materials. 4. The different time after processing did not affect SR Ivocap High Impact using long curing procedure. The long curing procedure could not show any differences between 24 and 48 hours from initial distances. Funding: None Competing interests: None declared Ethical approval: None (Laboratory study) References 1. Power JM, Ronald LS. CRAIG S Restorative Dental Materials 12th ed. United states of America: Elsevier; 2016: 514-550. 2. Anusavice KJ. Phillip s Science of Dental Materials 11th ed. Philadephia: Saunders; 2003: 143-169. 3. Darvell BW. Materials Science for Dentistry 9th ed. Oxford: Woodhead Publishing Limited; 2009: 61-80. 4. Henrike V, Klaus B, Ingrid P. The effect of processing methods and acrylic resins on the accuracy of maxillary dentures and toothless denture bases: An in vitro study. Quintessence Int 2011; 42: 669-677. 5. Gary CA, John KS, Thomas GA. Dimensional stability of injection and conventional processing of denture base acrylic resin. J Prosthet Dent 1988; 60: 394-398. 6. Robert AS. Comparison of changes in vertical dimension between compression and injection molded complete dentures. J Prosthet Dent 1989; 62: 716-718. 7. Sergio SN, Robert EO, Elaine LD. Comparison of accuracy between compression and injectionmolded complete denture. J Prosthet Dent 1999; 82: 219-300. 8. Paffenbarger GC, Standford JW. Processing denture base resins heat curing type. J Am Dent Assoc 1956; 53: 72-73. 9. Carol DH, Stephan EW. Dental Materials Clinical applications for dental assistants and dental hygienists. St. Louis: Saunders; 2003. 249-256. 10. Bhanodaya M, Andrzej S, David R. Dimensional change of heat-cured acrylic resin dentures with three different cooling regimens following a standard curing cycle. Eur J Prosthodont Rest Dent 2005; 13: 159-163. 163