Comparative study of MALDI-TOF MS and VITEK 2 in bacteria identification

Similar documents
Int.J.Curr.Microbiol.App.Sci (2016) 5(9):

Brief Communication Clinical Microbiology

MALDI-TOF mass spectrometry for direct bacterial identification

Received 1 March 2011/Returned for modification 19 April 2011/Accepted 20 May 2011

Original Article Clinical Microbiology INTRODUCTION

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of beta-hemolytic streptococci

TITLE: MALDI-TOF Mass Spectrometry for Bacterial Species Identification: A Review of Diagnostic Accuracy and Clinical and Cost-Effectiveness

Optimizing MALDI-TOF Use. Clinical Impact Laboratory Impact

Microorganisms direct identification from blood culture by matrixassisted laser desorption/ionization time-of-flight mass spectrometry

Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry

Abstract. Introduction

VITEK MS Implementation of Mass Spectrometry

National Surveillance of Nosocomial Septicemia (Hospital-wide)

SUPPLEMENTARY MATERIAL

Cefotaxime Rationale for the EUCAST clinical breakpoints, version th September 2010

S. Q. van Veen,* E. C. J. Claas, and Ed J. Kuijper. Department of Medical Microbiology, Leiden University Medical Center, Leiden, Netherlands

Tandem MS in Microbiology. Chris Doern, PhD D(ABMM) UT Southwestern Medical Center Dallas, TX

KENNEL KARE SC DISINFECTANT / CLEANER / DEODORIZER Efficacy Data EPA Reg. #

University of Alberta Hospital Antibiogram for 2007 and 2008 Division of Medical Microbiology Department of Laboratory Medicine and Pathology

Direct identification of bacteria from positive anaerobic BacT/Alert blood cultures by. Contents Category: Diagnostics, typing and identification

OVERVIEW OF CURRENT IDENTIFICATION SYSTEMS AND DATABASES

Spread of carbapenems resistant Enterobacteriaceae in South Africa; report from National Antimicrobial Resistance Reference Laboratory

Performance of mass spectrometric identification of bacteria and yeasts routinely isolated in a clinical microbiology laboratory using MALDI-TOF MS

Consultation on the Revision of Carbapenem Breakpoints

KENNEL KARE SC DISINFECTANT / CLEANER / DEODORIZER Efficacy Data EPA Reg. #

Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review

Medical Microbiology, University Hospital of Liège, Liège, Belgium

Supplemental Digital Content

Clinical Biochemistry

Microsan rx Anti-Microbial Healthcare Professional Soap. Organism Positives ATCC #

1430 West McCoy Lane Santa Maria, CA p:

Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for the Identification of Clinically Relevant Bacteria

Surveillance of Healthcare Associated Infections in Scottish Intensive Care Units

MALDI-TOF Mass Spectrometry: A New Rapid ID Method in Clinical Microbiology

Cefuroxime iv Rationale for the EUCAST clinical breakpoints, version th September 2010

Mongolia September 2012

The MALDI Biotyper An In Vitro Diagnostic System (IVD) for Identification of Bacteria and Yeasts with a Global Reach

Infections in transplants why is it so difficult to collect reasonable data regarding infections?

Detection of NDM-1, VIM-1, KPC, OXA-48, and OXA-162 carbapenemases by MALDI- TOF mass spectrometry

RESEARCH ARTICLE Torres et al., Journal of Medical Microbiology 2017;66: DOI /jmm

Comparison of MALDI-TOF MS, gene sequencing and the Vitek 2 for identification of seventy-three clinical isolates of enteropathogens

Optimized Use of the MALDI BioTyper System and FilmArray BCID Panel for the Direct

INFECTIOUS DISEASE. Page 2

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification

Comparison of CPS ID 3 and CHROMagar Orientation chromogenic agars with standard biplate technique for culture of clinical urine samples

DIVISION OF ANTIINFECTIVE DRUG PRODUCTS (HFD-520) CLINICAL MICROBIOLOGY REVIEW NDA Date review completed: 15 Jun 05

BACTERIOLOGY PROGRAMME AND PLAN OF TEACHING 3 rd Semester (academic year )

Identification of bacteria directly from positive blood culture samples by DNA pyrosequencing of the 16S rrna gene

Healthcare-associated infections acquired in intensive care units

Rapid identification and resistance assessment: The future is mass spectrometry

Efficacy Data. Disinfectant Cleaner & Odor Counteractant EPA REG. #

DNA pyrosequencing of the 16S rrna

Received 22 December 2009/Returned for modification 26 January 2010/Accepted 4 March 2010

MALDI-TOF mass spectrometry tools for microbial identification in archival document investigation

Ramanath Karicheri 1, Beena Antony 2* Original Research Article. Abstract

Infectious Disease Testing. UriSelect 4 Medium. Direct Identification Visibly Reliable

320 MBIO Microbial Diagnosis. Aljawharah F. Alabbad Noorah A. Alkubaisi 2017

Molecular approaches in the diagnosis of sepsis in neutropenic patients with haematological malignances

The Clinical Significance of Blood Cultures. Presented BY; Cindy Winfrey, MSN, RN, CIC, DON- LTC TM, VA- BC TM

Abstract. Introduction

Tigecycline activity tested against 26, 474 bloodstream infection isolates: a collection from 6 continents

Abstract. Introduction. Editor: R. Canton

Blue coloring. Enrichment medium for the simultaneous detection of total coliforms and Escherichia coli in water, foods and dairy products.

This material is supported in part by unrestricted educational grants from: Abbott, Bayer HealthCare, Merck Frosst, Roche Diagnostics, and Wyeth Inc.

Surveillance of Healthcare Associated Infections in Scottish Intensive Care Units

ESCMID Online Lecture Library. by author

The Public Health Benefit of CRE Colonization Testing

HYPOCHLOROUS ACID (HOCl) Our Body's immune system protector in a BOTTLE

M O L E C U L A R G E N E T I C S

BACTERIAL INTERVENTIONS TO INCREASE BLOOD SAFETY

Sep Oct Nov Dec Total

Cost Analysis of Implementing MALDI-TOF plus Real-time Antimicrobial Stewardship

General Bacteriology 1 (5080) and 2 (5081). List of microbes included in the specimens linked to the corresponding photo replies since

SCIENCE CHINA Life Sciences

Correlation between sputum and BAL cultures. 1. Pôle des Maladies Infectieuses et Tropicales Clinique et Biologique, Fédération de

Torres, Brian Carlmichael L., Ma. Luisa G. Daroy, Juan s. Lopez, Vanessa Oh, Marie Joan Loy, Prospero ma. Tuaño, and Ronald R. Matias Research and

CONSIDERATIONS IN UTI DETECTION AND POTENTIAL IMPACT ON ANTIBIOTIC STEWARDSHIP

IMMUVIEW S. PNEUMONIAE ANTIGEN TEST. Lateral flow test for qualitative detection of S. pneumoniae in urine and cerebrospinal fluid.

The value of acute phase reactants and LightCycler SeptiFast test in the diagnosis of bacterial and viral infections in pediatric patients

La «Fast Microbiology» applicata alla sepsi: prospettive ed opportunità

Matrix-assisted laser desorption/ionization timeof-flight

Evaluation of the feasibility of the VACUETTE Urine CCM tube for microbial testing of urine samples

Clinical experience with ceftazidime in urology in Japan

Physical Properties Appearance: Clear Liquid Fragrance: Fragrance Free Form: Gel ph: INCI Name*

Next Generation in Acne treatment. A new approach in Acne Treatment. GramaDerm. Advanced Acne Vulgaris Management with Microcyn Technology

Surveillance of Healthcare Associated Infections in Scottish Intensive Care Units

PATHOGEN DETECTION WITH THE FILMARRAY

Syndromic Testing: The right test, the first time.

Technical Summary: August 6, 2015 GFS BioProtect Foam Hand Sanitizer with Aloe Vera:

Matrix-assisted laser-desorption/ionization BIOTYPER: experience in the routine of a University hospital

Rapid identification of bacteria from positive blood culture bottles by MALDI-TOF MS following short-term incubation on solid media

MALDI-TOF MS: Translating Microbiology Laboratory Alphabet Soup to Optimize Antibiotic Therapy

Correlation between the Treatment Result and Causative Bacteria in Amputation of Diabetic Foot

General Bacteriology 1 and 2. List of samples and the microbes linked to the corresponding photo replies since

PREVENTIVE MEDICINE - LABORATORY

Treatment of febrile neutropenia in patients with neoplasia

SURVEILLANCE BLOODSTREAM INFECTIONS IN BELGIAN HOPITALS ( SEP ) RESULTS ANNUAL REPORT data

MALDI-TOF MS: a new tool to rapidly assess antibiotic susceptibility

Cell counting (EtBr) Before cell-lysis. Cell-lysis by 3% SDS beads beating. After cell-lysis

Transcription:

MALDI-TOF MS in Clinical Microbiology Comparative study of MALDI-TOF MS and VITEK 2 in bacteria identification Ling Guo, Liyan Ye, Qiang Zhao, Yanning Ma, Jiyong Yang, Yanping Luo Department of Microbiology, General Hospital of PLA, Beijing 100853, China Correspondence to: Yanping Luo. Department of Microbiology, PLA General Hospital, 28 Fuxing Road, Beijing 100853, China. Email: ypluo301@aliyun.com. Background: Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been introduced in diagnostic microbiology laboratories for the identification of bacterial and yeast strains isolated from clinical samples. This study aimed to evaluate the accuracy of MALDI-TOF MS in clinical microbiology diagnosis by comparing it with commonly-used VITEK 2 or gene sequencing. Methods: The performances of MALDI-TOF MS and VITEK 2 were compared retrospectively for identifying routine isolates. Discrepancies were analyzed by gene sequencing analysis of the 16S genes. Results: For 1,025 isolates, classified as 55 species of 25 genera, 1,021 (99.60%) isolates were accurately identified at the genus level, and 957 (93.37%) isolates at the species level by using MALDI-TOF MS. A total of 949 (92.59%) isolates were completely matched by both methods. Both methods found 76 unmatched isolates among which one strain had no definite identification by MALDI-TOF MS and VITEK 2 respectively. However, MALDI-TOF MS made no errors at the genus level while VITEK 2 made 6 (0.58%) errors at the genus level. At the species level, the identification error rates for MALDI-TOF MS and VITEK 2 were 5.56% and 6.24%, respectively. Conclusions: With a lower identification error rate, MALDI-TOF MS has better performance than VITEK 2 in identifying bacteria found routinely in the clinical laboratory. It is a quick and cost-effective technique, and has the potential to replace conventional phenotype methods in identifying common bacterial isolates in clinical microbiology laboratories. Keywords: Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS); VITEK2; bacteria identification Submitted Jan 18, 2014. Accepted for publication Feb 26, 2014. doi: 10.3978/j.issn.2072-1439.2014.02.18 View this article at: http://www.jthoracdis.com/article/view/2351/2939 Introduction Traditionally, bacterial and fungal identifications in clinical microbiology laboratories are mainly carried out according to phenotype characteristics, including identifications of culture media, colony morphology, gram stain and various biochemical reactions (1). Although all of these methods can achieve high accuracies, it usually takes minimum one day or longer to complete the whole identification process. Molecular methods, such as real-time PCR, gene sequencing and microarray analysis, are quick methods for bacterial and fungal identification, but they come at a very high cost and require highly-trained technicians. Therefore, molecular methods are not routinely used for bacterial identification. A faster and easier technique for microbial identification would greatly enhance the conventional laboratory in providing more timely feedback to clinic. This is especially true in cases when patients are critically ill suffering from infectious diseases and where therapeutic intervention is urgently needed. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) can be used to obtain protein fingerprinting from whole bacterial cells (2). Through comparing these fingerprints to a reference database by the use of various algorithms, bacteria can be rapidly identified. The earliest application of this technique

Journal of Thoracic Disease, Vol 6, No 5 May 2014 for bacterial identification dates back to 1975 (3), while the first related article was published in 1996 (Holland, et al.) (4). Studies in this field have been progressively advancing for the last decade (5). Until now, domestic comparative studies on mass spectrometry and other methods are relatively few. In order to compare the performance differences between MALDI-TOF MS and VITEK 2, the latter being the most-used automated identification technique in current microbiology laboratories, we employed the two systems in parallele to identify and analyze 1,025 isolates routinely isolated in 2012 at a microbiology laboratory of PLA General Hospital. 535 before adding 1 μl VITEK MS-CHCA matrix. Finally, the mass spectra acquired for each sample were compared to the known mass spectra contained in the database for, and given a confidence score according to how close the acquired spectra matched those contained in the database. ATCC8739 was used as the quality control strain. Gene sequencing Discrepancies between VITEK 2 and MALDI-TOF MS were resolved by 16S rrna gene sequencing. The results would be considered valid if the homologous rate was above 99%. Methods Bacteria isolates A total of 1,025 isolates, composed of 1,020 bacterial strains and 5 fungal strains representing 25 different genera were selected for analysis. These bacteria were routinely isolated from clinical patients, such as Pseudomonas spp, Acinetobacter spp that cause lung infections, Enterobacteriaceae that cause blood and urinary tract infections. In addition, there are also some bacteria which grow slowly but have clinical significance such as Eikenella corrodens, Listeria monotytogens, Haemophilus infuenzae, etc. VITEK 2 identification GP, GN, YST, ANC and NH were selected to run identification analysis according to the different strains to be tested. The identification rate was expected to be above 93% by VITEK 2 (biomérieux) (5), with quality control by stages via ATCC25922, ATCC27853 and ATCC25923. MALDI-TOF MS identification Strains were identified by MALDI-TOF MS using the VITEK MS system (biomérieux). Loops were used to select and smear the subject isolates onto the sample spots on the target slide. Then 1 μl VITEK MS-CHCA matrix was applied over the sample and air dried until the matrix and sample co-crystallized. The target slide with all prepared samples then was loaded into the VITEK MS system to acquire the mass spectra of whole bacterial cell protein, mainly composed of ribosomal protein, for each sample. In the case of yeasts, 0.5 μl VITEK MS-FA was added to each sample on the target slide and allowed to air dry it Standards for identification In cases where the isolate was correctly identified at the species level or at the generic level by both VITEK MS and VITEK 2, the results were considered to be in accordance with one another. In instances that the two methods produced different results, or if the results from one method were not definite, 16S rrna gene sequencing was used to resolve identification discrepancies. For isolates misidentified at the genus level, the results were considered a major mistake in the identification analysis. For isolates misidentified at species level but correctly identified at the genus level, the results were considered a minor mistake. Results not able to distinguish two different bacteria of the same genus also were considered as minor mistakes (6,7). Results Identification results by MALDI-TOF MS Among the 1,025 total isolates, 1,021 (99.60%) isolates were accurately identified at the genus level and 957 (93.37%) isolates at the species level by MALDI-TOF MS. Matched results by the two identification methods Identification results for 949 (92.59%) isolates, belonging to 23 genera and 48 species, were in agreement (see Table 1) using both methods. Unmatched results by the two identification methods Among the 1,025 isolates, 76 (7.4%) isolates produced discordant results between the two identification methods. One strain had no definitive identification for each

536 Guo et al. Comparative study of MALDI-TOF MS and VITEK 2 in bacteria identification Table 1 Matched results by both MALDI-TOF MS and VITEK 2 Bacterial genera Number of strains Acinetobacter banmannii complex 30 Corynebacterium jeikeium 1 Citrobacter braakii 2 Citrobacter freundii 6 Citrobacter koseri 1 Escherichia coli 297 Enterobacter aerogenes 13 Enterococcus casseliflavus 2 Enterococcus faecalis 10 Enterococcus faecium 24 Enterococcus gallinarum 1 Enterococcus hirae 3 Klebsiella oxytoca 10 Klebsiella pneumonia 66 Micrococcus ssp 3 Morganella morganii 7 Pseudomonas aeruginosa 126 Pseudomonas putida 1 Stenotrophomonas maltophilia 33 Proteus mirabilis 75 Proteus vul.gr/proteus pen. 9 Procidencia rettgeri 2 Staphylococcus aureus 76 Staphylococcus epidermidis 36 Staphylococcus hominisssphominis 37 Staphylococcus saprophyticus 1 Staphylococcus haemolyticus 14 Staphylococcus cohnii 1 Staphylococcus capitis 5 Serratia marcescens 23 Streptococcus parasanguinis 1 Streptococcus pneumonia 4 Streptococcus mitls/steptococcusoralis 3 Streptococcus gallolyticus 1 Streptococcus gordonii 1 Streptococcus sailvarius 1 Streptococcus agalatiae 5 Streptococcus sanguinis 1 Shewanella algea 3 Vibrio parahaemolyticus 1 Candida parapsilosis 2 Aeromonasssp 3 Chryseobacterium indologenes 1 Eikenella corrodens 1 Salmonella group 2 Listeria monotytogens 1 Haemophilus infuenzae 1 Burkholderia cepacia 1 Total 949 MALDI-TOF MS and VITEK 2. However, MALDI-TOF MS made no errors at the genus level while VITEK 2 made 6 (0.58%) errors at the genus level. At the species level, the identification error rates of the two methods were 5.56% and 6.24% for MALDI-TOF MS and VITEK 2 respectively (Table 2). Discussion and Conclusions In our laboratory, MALDI-TOF MS is an efficient, quick and relatively inexpensive per isolate method for identifying pathogenic microorganisms including bacteria and fungi. MALDI-TOF MS identification also is largely compatible with a large range of culture media and culture conditions, and is the fastest means to detect microbes in positive blood culture (8). Furthermore, MALDI-TOF MS has broader application prospects in the field of testing for drug resistance (9,10). Shortening the turnaround time to pathogen identification and offering quicker results to the clinic remain the most important issues needed to be solved in the microbiology laboratory. Based on our data, experienced clinicians can treat critically infected patients appropriate antibiotic treatment given effective and timely identification of pathogenic bacteria. Shortening the turnaround time permits the clinician to treat patients faster, ultimately reducing the fatality rates, the length of patient stay in the clinic, and healthcare costs associated with patient care. MALDI-TOF MS offers one promising solution to shorten the turnaround time and relieve these pressures in the clinic. In the present study, we chose 1,025 pathogenic bacteria routinely found in our laboratory for identification, and compared the performance of MALDI-TOF MS to the VITEK 2 system, the latter which is based on conventional biochemical identification that is presently found in most microbiology laboratories. Our results showed that MALDI-TOF MS offered higher identification accuracy and lower error rates at the species level when compared to VITEK 2. Additionally, MALDI-TOF MS dramatically shortened identification time from 6-8 hours to just a few minutes. MALDI-TOF MS identified 99.60% of isolates to the genus level and 93.37% of isolates to the species level, which are slightly higher rates than those previously reported (5,7,11-14). Van Veen et al., for example, achieved accuracy rates of 97.1% and 92% to the genus and species levels, respectively. The difference in accuracy is most likely due to the different choices of strains. The strains in van Veen s study included 61 yeast strains, among which 96.7%

Journal of Thoracic Disease, Vol 6, No 5 May 2014 537 Table 2 Unmatched results by both MALDI-TOF MS and VITEK 2 Bacterial species Number of strains VITEK MS VITEK 2 Generic errors Species errors Generic errors Species errors Acinetobacter banmannii 2 2 Acinetobacter jonnosonii 2 2 Citrobacter freundii 1 1 Enterobacter cloacae 46 46 46 Enterococcus faecium 1 1 Pseudomonas putida 1 1 Peudomonas aeruginosa 1 1 Staphylococcus hominis 4 4 Staphylococcus aureus 4 1 3 Staphylococcus epidermidis 1 1 Streptococcus agalactiae 2 2 Streptococcus mitis 3 3 3 Candida guilliermondii 1 1 Rhodotorula mucilaginosa 1 1 1 Achromobacter xylosoxidans 3 3 Chryse.indologenes 1 1 1 Listeria monocytogenes 1 1 Cryptococcus neoformans 1 1 Total 76 0 (0) 57 (5.56%) 6 (0.58%) 6 (6.24%) were identified to the genus level and 82.5% to the species level. Streptococcus viridans, streptococcus pneumoniae and anaerobic bacteria, all difficult pathogens to identify notably were included in van Veen s study and not in our study. Most of the strains analyzed in our study were largely more commonly found pathogens, and the construction of the MALDI-TOF MS database may offer higher identification accuracies for these pathogens. In conclusion, MALDI-TOF MS is a rapid, easy, relatively inexpensive and high-throughput method for identifying clinically relevant bacteria and fungi. MALDI-TOF MS offers very high accuracy, often higher than conventional methods, in identifying common microorganisms. Due to these key advantages and with continued development of MALDI-TOF MS technology and its clinical knowledgebase, MALDI-TOF MS will become a rapid, routine method for identifying pathogenic bacteria found in the conventional clinical microbiology laboratory. Acknowledgements Disclosure: The authors declare no conflict of interest. References 1. Carroll KC, Weinstein MP. Manual and automated systems for detection and identification of microorganisms. In: Murray PR, Baron EJ, Jorgensen JH, et al. eds. Manual of clinical microbiology. 9th ed. Washington, DC: American Society for Microbiology Press, 2007:192-217. 2. Fenselau C, Demirev PA. Characterization of intact microorganisms by MALDI mass spectrometry. Mass Spectrom Rev 2001;20:157-71. 3. Anhalt JP, Fenselau C. Identification of bacteria using massspectrometry. Anal Chem 1975;47:219-25. 4. Holland RD, Wilkes JG, Rafii F, et al. Rapid identification of intact whole bacteria based on spectral patterns using matrix-assisted laser desorption/ionization with time-offlight mass spectrometry. Rapid Commun Mass Spectrom 1996;10:1227-32. 5. Seng P, Drancourt M, Gouriet F, et al. Ongoing revolution in bacteriology: routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Clin Infect Dis 2009;49:543-51. 6. Bizzini A, Durussel C, Bille J, et al. Performance of

538 Guo et al. Comparative study of MALDI-TOF MS and VITEK 2 in bacteria identification matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of bacterial strains routinely isolated in a clinical microbiology laboratory. J Clin Microbiol 2010;48:1549-54. 7. van Veen SQ, Claas EC, Kuijper EJ. High-throughput identification of bacteria and yeast by matrix-assisted laser desorption ionization-time of flight mass spectrometry in conventional medical microbiology laboratories. J Clin Microbiol 2010;48:900-7. 8. Drancourt M. Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review. Clin Microbiol Infect 2010;16:1620-5. 9. Burckhardt I, Zimmermann S. Using matrix-assisted laser desorption ionization-time of flight mass spectrometry to detect carbapenem resistance within 1 to 2.5 hours. J Clin Microbiol 2011;49:3321-4. 10. Hrabák J, Walková R, Studentová V, et al. Carbapenemase activity detection by matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 2011;49:3222-7. 11. Blondiaux N, Gaillot O, Courcol RJ. MALDI-TOF mass spectrometry to identify clinical bacterial isolates: evaluation in a teaching hospital in Lille. Pathol Biol (Paris) 2010;58:55-7. 12. Dupont C, Sivadon-Tardy V, Bille E, et al. Identification of clinical coagulase-negative staphylococci, isolated in microbiology laboratories, by matrix-assisted laser desorption/ionization-time of flight mass spectrometry and two automated systems. Clin Microbiol Infect 2010;16:998-1004. 13. Dubois D, Leyssene D, Chacornac JP, et al. Identification of a variety of Staphylococcus species by matrixassisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 2010;48:941-5. 14. Spanu T, De Carolis E, Fiori B, et al. Evaluation of matrix-assisted laser desorption ionization-time-offlight mass spectrometry in comparison to rpob gene sequencing for species identification of bloodstream infection staphylococcal isolates. Clin Microbiol Infect 2011;17:44-9. Cite this article as: Guo L, Ye L, Zhao Q, Ma Y, Yang J, Luo Y. Comparative study of MALDI-TOF MS and VITEK 2 in bacteria identification.. doi: 10.3978/j.issn.2072-1439.2014.02.18