SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ENTHALPY ANALYTICAL, INC East Parham Road Richmond, VA Gwen Vaughan Phone:

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CORESTA Recommended Methods with history and correspondence with ISO Standards

SCOPE OF ACCREDITATION TO ISO/IEC GUIDE 34:2009. SPEX CERTIPREP GROUP, LLC. 203 Norcross Avenue Metuchen, NJ Gael Miller Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

WHO work on smokeless tobacco. Dr Vinayak Prasad, WHO HQ Ms Sarah Emami, WHO HQ

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

The fitness for purpose of existing tobacco product test methods identifying the gaps

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Routine Analytical Chemistry Sub-Group Report Berlin 2016

Tobacco Blend Style. Dinah Winter, Martin Coleman, Nigel Warren

Progress of the validation of analytical chemical methods for testing and measuring cigarette contents and emissions

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

The Effect of Puff Duration on Smoke Chemistry

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

TECHNICAL APPENDIX C REQUIRED CONTAINERS, PRESERVATION TECHNIQUES, HOLDING TIMES AND 40 CODE OF FEDERAL REGULATIONS (CFR) PART 136

PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

Smoke Analytes Sub-Group (SMA) 2017 Report

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TNCO Testing procedures

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Contribution To Standards Development For Next Generation Products. Dr Nils ROSE

Contribution To Standards Development For Next Generation Products. Eduardo BEREA Alternative Ingredients ENDS 2018 London 4-5 June 2018

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Menthol Addition to Cigarettes Using Breakable Capsules in the Filter. Impact on the Mainstream Smoke Yields of the Health Canada List Constituents

Evaluation of the Potential for Second-hand Exposure to E-cigarette Aerosol in an Office Environment

THE INFLUENCE OF CIGARETTE FILTER DESIGN ON THE YIELD AND COMPOSITION OF CIGARETTE SMOKE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Cigarettes Determination of tobacco specific nitrosamines in mainstream cigarette smoke Method using LC-MS/MS

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010 PROFICIENCY TESTING PROVIDER

2014_TSRC77_Melton.pdf

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CORESTA RECOMMENDED METHOD NÄ 9

DEVELOPMENT OF A TECHNIQUE FOR THE DETERMINATION OF ph-values OF AEROSOLS GENERATED BY E-CIGARETTES

CHARACTERIZING PASSIVE EXPOSURE TO TOBACCO SMOKE

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

INTERNATIONAL STANDARD

CORESTA Recommended Method No. 84

E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017

CHEM 105 Module 11 QUIZ

GC-MS analysis of e-liquids taken. from e-cigarettes and e-liquids (e-juice) before use in e-cigarettes

Indoor Air Pollution. Indoor Air Pollution. Trends. Indoor Air Pollution Trends Sources. Regulation and Abatement 2

Air Quality assessment during indoor use of the Tobacco Heating System 2.2

This student paper was written as an assignment in the graduate course

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited Proficiency Testing Provider

10.6 Schedule of Accreditation

A New Method for the Analysis of Carbonyl Compounds in e-cigarette Liquids

FORMs of TOBACCO. 2 nd of 3 Prep for Session 1

Calibration Factors and Time-and-Distance Guidelines For Use of Theatrical Fog Equipment

Physical design analysis and mainstream smoke constituent yields of the new potential reduced exposure product, Marlboro UltraSmooth

What is worse, cigarettes or narghile?

What is combustion and why is the absence of combustion important for heat not burn products

Toxic Contents and Emissions in Smokeless Tobacco Products

SPECTRA EAST, INC. Rockleigh, NJ

October 11, Division of Dockets Management (HFA-305) Food and Drug Administration 5630 Fishers Lane Rm.1061 Rockville, MD 20852

RE: Docket No. FDA-2014-N , Electronic Cigarettes and the Public Health

Approaches for the design of reduced toxicant emission cigarettes

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CORESTA RECOMMENDED METHOD N 39

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

FIt s a late summer s afternoon in Jarrow, A LAB OF ITS TIME

Air Quality assessment during indoor use of the Tobacco Heating System 2.2

F-RQS-05 PT SCHEM Page 1 of 5

Technical Report. CORESTA Reference Products

Smoking vs Smokeless. Tobacco is a plant that contains nicotine. Cigars and pipes contain more tar and other chemicals.

Harmful and Potentially Harmful Constituents in Tobacco Products and Tobacco Smoke;

A. Incorrect! The alveolus is where gas exchange takes place. B. Correct! Surfactant is the lipid-rich material that permits lung inflation.

CERTIFICATE OF ACCREDITATION

UK E-Cigarette Summit Relative risks of cancer posed by combustible and vapourising forms of nicotine delivery: Evidence from chemical exposures

Schedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).

Technical Report. Analysis of Moisture Content (Oven Volatiles) of Smokeless Tobacco Products

Annex F1/15 to the Certificate No SCOPE of ACCREDITATION of the Testing Laboratory A. TSAKALIDIS Inc.

B. Food and Animal Feed 1. Aerobic Plate Count ISO 4833: Enumeration of Spores of ISO 15213:2003 Sulphite Reducing Bacteria

E-Cigarette Aerosol Analysis Report

INTERNATIONAL STANDARD

Particle Size Distribution of E-Cigarette Aerosols and the Relationship to Cambridge Filter Pad Collection Efficiency

E-Cigarette Aerosol Analysis Report

Technical Report. Determination of Nitrate in Smokeless Tobacco Products by Continuous Flow Analysis

Chapter 11 Tobacco Section 1: Tobacco Use

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Again, congratulations. If you have any questions, please contact Lauren Schnack, Senior Specialist, Quality and Accreditation, at (703)

2017_ST10_JinCathy.pdf. SSPT Document not peer-reviewed by CORESTA

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

GRUPO ANALIZA CALIDAD. International Workshop UBU 2013 Silvia Raliegos Martín

July 10, Division of Dockets Management (HFA-305) Food and Drug Administration 5630 Fishers Lane, Room 1061 Rockville, MD 20852

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Smoke Yields of Tobacco-Specific Nitrosamines in Relation to FTC Tar Level and Cigarette Manufacturer: Analysis of the Massachusetts Benchmark Study

Pierre-Marie GUITTON Next Generation Nicotine Delivery London June, 2017

DECISION. Recalling further its decision FCTC/COP5(6) to adopt further partial guidelines;

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ENTHALPY ANALYTICAL, INC. 1470 East Parham Road Richmond, VA 23228 Gwen Vaughan Phone: 804 887 2104 CHEMICAL Valid To: November 30, 2019 Certificate Number: 1873.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following types of tests on tobacco, tobacco smoke, and electronic cigarettes: Mainstream (MS) and Sidestream (SS) Smoke Analysis: Acetamide & Acrylamide (MS) by GC/MS AM-127 Ammonia (MS/SS) by HPLC AM-011 HC T-101, HC T-201 Analytical Smoke Machines SOP EQU-037 HC T-115, FR11178, FR45483 ISO3308, ISO3402, ISO4387, CRM No.64 Benzo(a)pyrene (MS) by HPLC AM-207 HC T-103 Benzo(a)pyrene (SS) by HPLC AM-208 HC T-203 Carbon Monoxide (MS) by NDIR AM-007 HC T-115, HC T-214, FR11178, FR46483, ISO8454, CRM No.68 Carbonyls (MS) by UPLC AM-076 HC T-104 Carbonyls (MS/SS) by HPLC AM-005 HC T-204 Ethyl Carbamate by GC/MS AM-175 Eugenol (MS/SS) by HPLC AM-087 HC T-105 Filter Efficiency (MS) by GC AM-026 Humectants (MS) by GC/FID AM-105 HC T-115, HC T-304 Hydrogen Cyanide (MS/SS) by CFA AM-111 HC T-107, HC T-205 Ignition Propensity AM-050 ASTM 2187-04, ASTM 2187-09 ISO 12863:2010 Mercury (MS) by CVAA AM-036 HC T-108 Mercury (SS) by CVAA AM-041 HC T-206 Metals (MS) by ICP/MS AM-021 HC T-109 Metals (SS) by ICP/MS AM-043 HC T-207 Nicotine, Water, and Menthol (MS) by GC AM-001 HC T-115, FR11178, FR46483 ISO10315, ISO10362-1,ISO4387 CRM No.65, No.66, No.67 Nitric Oxide (MS) by Chemiluminescence AM-029 Nitric Oxide (MS) by Chemiluminescence AM-216 HC T-110 Nitric Oxide (SS) by Chemiluminescence AM-034 Nitric Oxide (SS) by Chemiluminescence AM-217 HC T-208 ph (MS) by ph Meter AM-016 (A2LA Cert. No. 1873.01) 12/5/2017 Page 1 of 4

ph (MS) by ph Meter AM-093 HC T-113 ph (SS) by ph Meter AM-092 Phenolics (MS) by HPLC AM-027 HC T-114 Phenolics (SS) by HPLC AM-048 HC T-211 Primary Aromatic Amines (MS/SS) by GC/MS AM-030 HC T-102, HC T-202 Primary Aromatic Amines (MS) by GC/MS Polycyclic Aromatic Hydrocarbons (MS) by GC/MS Polycyclic Aromatic Hydrocarbons (MS/SS) by GC-MS AM-199 AM-190 AM-044 Semi-Volatiles (MS/SS) by GC/MS AM-006 HC T-112, HC T-210 Tar, Nicotine, and CO (SS) by GC and NDIR AM-008 HC T-212 Mainstream (MS) and Sidestream (SS) Smoke Analysis cont d: Tobacco Specific N-Nitrosamines (MS) by AM-020 LC/MS/MS Tobacco Specific N-Nitrosamines (MS) by AM-210 HC T-111 GC Tobacco Specific N-Nitrosamines (SS) by GC AM-211 HC T-209 Volatiles (MS/SS) by GC/MS AM-015 HC T-116, HC T-213 Volatiles I (MS) by GC/MS AM-180 Volatiles II (MS) by GC/MS AM-193 Physical Properties: Physical Properties AM-009 ISO: 2971, 4387, 6565, 9512 CRM No.65 Permeability AM-057 ISO2965 Weight of Cigars/Cigarettes per Thousand AM-186 Tax Purposes Tobacco: Ammonia by HPLC AM-115 HC T-302 Anions by HPLC AM-110 Benzo(a)pyrene by UPLC AM-125 HC T-307 Carbonyls in Tobacco by UPLC-MS/MS AM-240 CDC Nicotine by GC-FID AM-072 FR Volume 74, No. 4 CDC Oven Volatiles and ph by ph Meter AM-071 FR Volume 74, No. 4, AOAC 966.02 (OV) Methyl Salicylate (Wintergreen) and AM-078 Ethyl Salicylate by GC/MS Eugenol by HPLC AM-088 HC T-314 Humectants by GC/FID AM-090 HC T-304 (A2LA Cert. No. 1873.01) 12/5/2017 Page 2 of 4

Tobacco cont d Mercury by CVAA AM-095 HC T-306 Metals by ICP/MS AM-052 HC T-306 Minor Alkaloids by GC/MS AM-100 Nicotine by GC/MS AM-100 Nicotine by GC/NPD AM-206 HC T-301 Nitrate by CFA AM-218 HC T-308 Nitrite by CFA AM-182 Organic Nitrogen by CFA AM-183 Oven Volatiles by Gravimetric AM-058 ph by ph Meter AM-053 HC T-310 Polycyclic Aromatic Hydrocarbons by AM-187 GC/MS Protein Nitrogen by CFA AM-184 Reducing Substances by CFA AM-197 ISO 15153 Reducing Sugars by CFA AM-074 CRM No. 38 Sodium Propionate by GC/MS AM-170 Sodium Propionate by GC-FID AM-089 HC T-312 Sorbic Acid by HPLC AM-098 HC T-313 Tobacco Specific N-Nitrosamines by AM-031 LC/MS/MS Tobacco Specific N-Nitrosamines by AM-209 HC T-309 GC/TEA Total Alkaloids by CFA AM-114 ISO15152 Total Sugars by CFA AM-073 CRM No. 38 Total Sugars (as Reducing Sugars) by CFA AM-113 FR Notice No 66, Volume 71 Triacetin by GC/MS AM-099 HC T-311 Water Activity in Smokeless Tobacco AM-233 Toxicology Services: Ames Assay AM TOX-001 HC T-501 Neutral Red Uptake Assay AM TOX-002 HC T-502 Micronucleus Assay AM TOX-003 HC T-503 Sister Chromatid Exchange AM TOX-004 Micronucleus in Binucleated Cells AM TOX-005 Skin Irritation Assay AM TOX-008 Cytokine Analysis AM TOX-009 Mycoplasma Test AM TOX-010 Total Bacteria, Yeast and Mold Enumeration AM TOX-011 BAM, 8 th edition, Rev. A, 1998. Ch 18, AOAC 966.23 Mainstream Smoke for Bacterial Reverse AM-122 HC T-122 Appendix I, HC T-115 Mutation Assay Mainstream Smoke for Neutral Red Uptake Assay AM-123 HC T-123 Appendix I, HC T-115 (A2LA Cert. No. 1873.01) 12/5/2017 Page 3 of 4

Mainstream Smoke for InVitro Micronucleus Assay AM-124 HC T-124 Appendix I, HC T-115 Electronic Cigarettes: Test Description Method Carbonyls in E-Cigarette Aerosol By HPLC-UV AM-236 Carbonyls in E-Cigarette Aerosol By HPLC-UV AM-236 Carbonyls in E-Liquid by UPLC-UV AM-239 Nicotine Degradants in E-Liquid and E-Cigarette AM-238 Aerosol by LC-MS Nicotine Degradants in E-Liquid and E-Cigarette AM-238 Aerosol by LC-MS Nicotine, Menthol and Humectants in E-liquid AM-200 by GC-FID Nicotine, Menthol, Humectants and Contaminants AM-201 in E-Cigarette Aerosol by GC-FID ph in Smoke and E-Cigarette Aerosol AM-237 ph in Smoke and E-Cigarette Aerosol AM-237 ph of E-Liquid AM-232 ph of E-Liquid AM-232 Primary Aromatic Amines (PAAs) AM-221 in E-Cigarette Vapor by GC-MS Selected Carbonyls in E-liquid by GC-MS AM-227 Selected Diketones In E-Liquid By GC/MS AM-230 Selected Diketones In E-Liquid By GC/MS AM-230 Selected Metals In E-Liquid and Trapped Aerosol AM-235 By ICP/MS Selected Metals In E-Liquid and Trapped Aerosol AM-235 By ICP/MS Tobacco Specific N-Nitrosamines in E-liquid AM-225 by LCMSMS Tobacco-Specific N-Nitrosamines (TSNAs) AM-220 in E-Cigarette Vapor by LCMSMS Water in E-Cigarette Vapor by GC-TCD AM-223 Water in E-Cigarette Vapor by GC-TCD AM-223 Water in E-liquid by GC-TCD AM-222 Key: FR = Federal Register / ISO = International Standards Organization / HC = Health Canada (A2LA Cert. No. 1873.01) 12/5/2017 Page 4 of 4

Accredited Laboratory A2LA has accredited ENTHALPY ANALYTICAL, INC. Richmond, VA for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 5 th day of December 2017. President & CEO For the Accreditation Council Certificate Number 1873.01 Valid to November 30, 2019 For the tests to which this accreditation applies, please refer to the laboratory s Chemical Scope of Accreditation.