Integra. Uni CP Compression Plating System PRODUCTS FOR SALE IN EUROPE, MIDDLE EAST AND AFRICA ONLY

Similar documents
ADVANSYS Midfoot plating system

Integra. surgical technique. Advansys Midfoot Plating System. eng. D.L.P. Dorsal Lisfranc Plate. M.L.P. Medial Lisfranc Plate

large qwix Positioning and fixation screws Surgical Technique lower large qwix English PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST and AFRICA ONLY

IPP-ON. Interphalangeal implant. Surgical Technique. l o w e r e x tre mit y. Or t h o pa e d i c s. IPP-ON English

Integra. Solustaple Standard staple SURGICAL TECHNIQUE. Uni-Clip Compression staple. Products for sale in Europe, Middle-East and Africa only.

eng Integra surgical technique Large Qwix Products for sale in Europe, Middle-East and Africa only.

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

SURGICAL TECHNIQUE. Compression screw FOREFOOT SOLUTIONS

HALLU-FIX ENGLISH. HALLU -FIX M.T.P. Arthrodesis System. Surgical Technique

TIBIAXYS. A u n i q u e p l a t i n g s y s t e m for distal tibial osteotomy. Surgical technique

Headless Compession Screw 2.5 / 3.0

Technique Guide Small Bone Fusion System

Lapidus Arthrodesis System Instructions for Use

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

eng Integra surgical technique TIBIAXYS Osteotomy - Arthrodesis Products for sale in Europe, Middle-East and Africa only.

Zimmer Anterior Buttress Plate System. Surgical Technique

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment

AxSOS Locking Plate System

Technique Guide KISSloc Suture System

Flexible Fragment Fixation. Surgical Technique

Asnis. Micro Cannulated screw system. Xpress operative technique

MetaFix Ludloff Plate

O.S.2-C & O.S.2-V. Static Staple - Stainless steel

DISTAL RADIUS. Instructions for Use

Table of Contents.

ACP1 CERVICAL PLATE SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE II.

TM TM Surgical Technique

EasyStep. Operative technique

D. The following factors are of extreme importance to the eventual success of the procedure.

Zimmer Small Fragment Universal Locking System. Surgical Technique

3.5 mm LCP Extra-articular Distal Humerus Plate

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

A U X I L I A R Y C O N N E C T O R S Surgical Technique

Technique Guide Lapidus Arthrodesis System

3.5 mm LCP Olecranon Plates

Salto Talaris Total Ankle Prosthesis

SMV Scientific Bone Plate and Screw System Surgical Technique

Revision A Date:

TC-PLUS Primary Knee IMPORTANT MEDICAL INFORMATION SPECIAL NOTE. This Package Insert is for product distributed in the US only.

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

Low Bend Distal Tibia Plates

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

TIBIAXYS ANKLE FUSION

OPERATIVE TECHNIQUE. anterior cervical plating system

Hinged Laminoplasty System surgical technique

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Precautionary Statement ( )

BONE GRAFT WASHER _Rev A IMPORTANT INFORMATION ON THE BONE GRAFT WASHER

3.5 mm Locking Attachment Plate

O.S.2-C. Compression staple PEEK

INTELLIGENT SPINAL SYSTEM

IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY)

MetaCun DuoMetaCun. Midfoot Fusion Locking Plate System. Surgical Technique and Ordering Information

Gallery Laminoplasty Spine System

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

3.0 mm Cannulated Screw System. Surgical Technique

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

Peanut Growth Control Plating System

Surgical Technique. Calcaneal Locking Plate

KATALYST. Bipolar Radial Head System. Surgical Technique. orthopedics. KATALYST English. PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST and AFRICA ONLY

Surgical Technique. Clavicle Locking Plate

Surgical Technique. Distal Humerus Locking Plate

Complex process High costs

A New Benchmark in Tibial Fixation

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

NCB Distal Femur System. Surgical Technique

Telya. Varisation staple. Surgical Technique. Irish Distributer: O'Mara Medical Tel

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

PediLoc Tibia Surgical Technique

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Instructions for Use Reprocessed Arthroscopic Shavers

PROXIMAL TIBIAL PLATE

Cervical Screw System

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Surgical Technique. Olecranon Locking Plate

For use by an Accredited Orthopaedic Surgeon only

LBL-014. Rev

Conventus CAGE PH Surgical Techniques

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Integra Total Foot System 2

The Flower Proximal Humerus Plate

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

HawkeyeTM Peek. surgical technique

Surgical Technique. Apache Anterior Lumbar Interbody Fusion

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

The Flower Forefoot PROCEDURE GUIDE.

Royal Oak Cervical Plate System

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

Ratcheting Compression Plating System. Surgical Technique

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

Memory Staple. Surgical Technique

Transcription:

TM Integra Uni CP Compression Plating System S U R G I C A L T E C H N I Q U E

Uni CP Compression Plating System Table of contents Indications...03 Contraindications...03...03 Surgical Technique... 04 Step n 1: Surgical approach... 04 Step n 2: Positioning trial plate... 04 Step n 3: Plate contouring... 05 Step n 4: Assembling the drill guides... 05 Step n 5: Drilling and hole preparation... 05 Step n 6: Screw insertion... 06 Step n 7: Compression... 06 X-Rays... 06 Instructions for use...07 References... 08 2 PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY

Indications The UNI CP compression plates are indicated for fixation of bone fractures or for bone reconstruction: Arthrodesis in foot and ankle surgery. Fractures management in the foot and ankle. Mono or bi cortical osteotomies in the foot and ankle. Contraindications The implant should not be used in a patient who has currently, or who has a history of: Local or systemic acute or chronic inflammation, Active infection or inflammation, Suspected or documented metal allergy or intolerance. 3 plate configurations:» 2 hole design (17, 20, 25, and 30 mm interaxis)» 4 hole design (20, 25, and 30 mm interaxis)» 4 hole T shape design (20 mm interaxis) Range of screw lengths» 12 mm to 40 mm in 2 mm increments Surfix Locking Technology Material:» Plates: Stainless steel 316L (ISO 5832 1 / ASTM F138&139)» Screws: Titanium alloy Ti 6Al 4V (ISO 5832 3 / ASTM F136) 3

339 004 Trial plate t et u 339 005 Implant sizer 2 and 4 holes Surgical technique This technique has been developed with the help of Stephen Conti, MD. NEWDEAL as the manufacturer of this device, does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient. The surgeon who performs any implant procedure is responsible for determining and using the appropriate techniques for implanting the device in each patient. 1. Surgical approach The articular surfaces should be prepared using standard technique to resect the necessary amount of cartilage and, if necessary, to remove bone graft material. Obtain adequate reduction and provisional fixation using guide wires or reduction forceps. 2. Positioning trial plate Use the trial implant (339 005, 339 004) to determine the ideal plate configuration and position. Depending on the indication, the surgical exposure may not accommodate the trial plate. Place the graduated end of the trial over the larger bone (fragment), under the soft tissue to minimize irritation. HINT 1mm guide wires can be placed through the trial to maintain plate alignment if desired. 4

115 101 K wire diam. 1.0 mm, L. 100 mm 219 735 Bending Forceps diam. 3.5 mm hole, L. 171 mm 219 635 Drilling guide diam. 2.7 mm 219 835 Screwdriver/Hex. diam. 2.0 mm, L. 180 mm 339 003 Holder 3. Plate contouring The chosen plate can be contoured, prior to application, to better fit the patient s anatomy. A set of two plate benders (219 735) are included to aid in this process. It is important to position the benders in the locking holes to protect the locking mechanical properties of the plate design. If this is not the case, the intermediate locking threads may be damaged or deformed, thus preventing optimal functioning of the lock-screw mechanism. WARNING The plate will weaken with excessive bending. The Uni CP plate may be bent only once and should not be bent excessively. Attach the drill guides to the appropriately contoured plate. 4. Assembling the drill guides Assemble the drilling guides to the bended plate. 5. Drilling and hole preparation Position the plate in the desired location. An implant holder (339 003) can be secured to any one of the drill guides to aid in this process. 1 mm guide wires can then be inserted into the wire holes in the plate for temporary fixation. HINT If 1mm guide wires were introduced through the trial instrument, the plate can be introduced over them. 5

219 535 Drill AO diam. 2.7 mm, L. 190 mm 219 335 Depth gauge diam. 3.5 mm screws 219 835 Screwdriver/Hex. diam. 2.0 mm, L. 180 mm 219 435 Screwdriver/ AO hex. diam. 2.0 mm, L. 76 mm 339 001 Compression forceps 6. Screw insertion For each hole, the following steps must be followed as shown in figures A to F: Fig. 6 b Fig. 6 a Prepare holes with the 2.7 mm drill (219 635) through the drilling guide. The screw length can be read from the calibrated scale on the drill. The depth is read from the top side of the drilling guide. Fig. 6 d Insert the screw into the prepared hole until the plate is at the desired position relative to the bone. The screw should be fully seated in the plate. Clean the threaded hole before and after introducing the screw. Maintain co axiality between the screw and the threaded hole. Fig. 6 c Fig. 6 e Assemble the lock screw to the appropriate screwdriver. The lock screw should be inserted after each screw, and before preparation and insertion of the subsequent screw. This prevents potential damage to thread. WARNING Steps a to f should be completed for each screw before starting preparation of the subsequent screw(s). If not, the axes of the screw and the prepared hole may be misaligned. 7. Compression After all screws are locked in place, compress the Uni CP plate using the compression forcep (spreading) instrument (339 001) Upon opening the diamond designed bridge, the compressive forces will pull the ends of the plate toward one another 8. X-Rays 6 Chamfer the drill hole with the screwdriver. Ensure that the threaded hole is not damaged when performing the chamfering. Alternately, measure the necessary screw length using the length gauge (219 335), after having removed the drill guide. Surgical Technique Uni CP Compression Plating System PRODUCTS FOR SALE IN EUROPE, MIDDLE EAST AND AFRICA ONLY Fig. 6 f Locking: Fully seat the lock screw with the screwdriver. The lock screw should be flush with the top of the plate when it is fully inserted. 219 635 Drilling guide

INSTRUCTIONS FOR USE In accordance with the directive 93/42/EEC relative to medical devices, this product must be handled and/or implanted by WELL- TRAINED and QUALIFIED PERSONS, AWARE OF THESE INSTRUCTIONS FOR USE. The osteosynthesis systems manufactured by Newdeal, are designed for the fi xation of fractures, fusions and osteotomies, more especially for foot, ankle and hand surgery. Material: Plates: 316L (ISO 5832-1 / ASTM F138&139) Screws: Ti-6Al-4V (ISO 5832-3 / ASTM F136) Indications For fi xation of bone fractures or for bone reconstruction. Examples include: Arthrodesis in hand or foot surgery Fractures management in the foot or hand Mono or Bi-cortical osteotomies in the foot or hand Distal or proximal metatarsal or metacarpal osteotomies Fixation of osteotomies for Hallux Valgus treatment (such as Scarf, Chevron, etc.) The size of the chosen staple should be adapted to the specifi c indication. The UNI-CP Plates have to be fi xed with the Surfi x Locking System screws and washers diam. 3.5 mm. Contraindications The implant should not be used in a patient who has currently, or who has a history of: Local or systemic acute or chronic infl ammation; Active infection or infl ammation; Suspected or documented metal allergy or intolerance. Warnings Serious post-operative complications may occur from use of the implant in a patient who: Lacks good general physical condition; Has severe osteoporosis; Demonstrates physiologic or anatomic anomalies; Has immunological responses, sensitization, or hypersensitivity to foreign materials; Systemic or metabolic disorders. Precautions for use Physician must determine if implant is appropriate for patients who have any of the following conditions: Drug and/or alcohol and/or smoke addiction and/or abuse, Infectious disease, Malignancy, Local bone tumors, Compromised wound healing, Obesity, Demonstrated psychological instability, displayed a lack of understanding, inappropriate motivation, or attitude, Unwillingness to accept the possibility of multiple surgeries for revision or replacement, Lacks an understanding that a metallic implant is not as strong as normal healthy bone and will bend, loosen, or fracture if excessive demand is placed on it, Lacks an understanding that their preoperative capacity may not be fully recovered even after successful implantation, Knowledge of surgical techniques, proper reduction, selection and placement of implants, and post-operative patient management are considerations essential to a successful outcome. Criteria for patient selection are the responsibility of the surgeon. Information contained within this document should be taken into consideration during the selection process. Recognition of the appropriate indications and contraindications and the selection of the proper surgical procedures and techniques determined to be best for the patient are the responsibility of the surgeon. Each surgeon must evaluate the appropriateness of the procedure and instruments used during the procedure based on his or her own training and experience. The surgeon should discuss with the patient prior to surgery possible risks, precautions, warnings, consequences, complications, and adverse reactions associated with the surgical procedure and implantation of the device. Each patient must be evaluated by the surgeon to determine the specifi c risk/benefi t relationship in light of the patient s condition and the surgeon s practice, training, experience, and knowledge of the related medical literature. Complications with the use of osteosynthesis systems have been reported in the medical literature. Any patient undergoing a surgical procedure is subject to intra-operative and postoperative complications. Each patient s tolerance to surgery, medication, and implantation of a foreign object may be different. Possible risks, adverse reactions, and complications associated with surgery and the use of osteosynthesis systems should be discussed with and understood by the patient prior to surgery. The implant is made from metallic alloys; therefore, it is subject to possible reactions and complications, including those listed herein. The patient should not be led to unrealistic expectations as to the performance or results that the surgery and implant can provide. The patient should be informed that the life expectancy of the device is unpredictable once implanted, and that successful results cannot be guaranteed. IT IS THE RESPONSIBILITY OF THE SURGEON TO PROVIDE THE PATIENT WITH INFORMATION PRIOR TO SURGERY. Complications may include but are not limited to: Pain, discomfort, or abnormal sensations due to presence of the implant, Bending, loosening, and/or breakage, which could make removal impracticable or diffi cult, Risk of additional injury from post-operative trauma, Migration of the implant position or implant material resulting in injury, Bone loss due to stress shielding. Side effects may include but are not limited to: Infections, Hematoma, Allergy, Thrombosis, Bone non-union or delayed union. Adverse effects may necessitate re-operation, revision or removal surgery, arthrodesis of the involved joint, and /or amputation of the limb. Implant removal should be followed by adequate postoperative management to avoid fracture or re-fracture. Interference risks during medical imaging: MRI/SCANNER: ask the patient to systematically mention that he/ she was implanted with a metallic device. Packaging - sterility This product is sold either sterile or non sterile. The sterilization method is specifi ed on the packaging. Components sterilized by radiation are exposed to a minimum of 25 kgy of gamma irradiation. If the product is not labeled «STERILE», it must be sterilized prior to use, in compliance with current regulations. If the product has been removed from packaging but not used, it may be re-sterilized. Check packaging and labeling integrity before use. The sterility is guaranteed as long as the packaging has not been damaged or opened and before the expiration date. Do not use any implant for which the packaging has been opened or damaged outside the operating theatre. Inner packaging should be handled under sterile conditions (persons/instruments). Use of the products The surgeon must use the instrumentation recommended in accordance with the operative technique available from the manufacturer. The medical device must be used in compliance with the use of the profession and the standard of art. Do not attempt a surgical procedure with faulty, damaged or suspect instruments or implants. Inspect all components preoperatively to assure utility. Alternate fi xation methods should be available intraoperatively. Opening of the instruments set must be done according to aseptic condition. When handling the implants, avoid any contact with other material or tools which may damage the implant surface. Under no circumstances should the implant be modifi ed. The multi-component devices (such as plates-screws systems) should only associate the appropriated Newdeal products and should never be used in conjunction with components of any other manufacturers, as these products may not be compatible. The company accepts no responsibility for such use. Specifi c cautions for plates The plates should never been excessively bent, nor reverse bent. Re-use of the implants Orthopedic implants already implanted must never be re-used. The company accepts no responsibility for such re-use. Re-sterilization of non-implanted implants and sterilization of non-sterile products Unless supplied sterile and clearly labeled as such, all implants and instruments must be steam autoclaved prior to use in surgery. Resterilization is only allowed for non-implanted products. Remove delivery packaging in compliance with current regulations to sterilize non-sterile products. Ostesynthesis implants manufactured by Newdeal are recommended to be sterilized by the steam autoclaving procedure regularly used in the hospital. The implants can be sterilized several times in the same conditions. The following two methods have been validated by the manufacturer: Newdeal Stainless Steel sterilization trays CYCLE GRAVITY DISPLACEMENT 5 PULSES [MAXIMUM 900 MBAR; MINIMUM 200 MBAR] PRE-VACUUM 3 PULSES [MAXIMUM 26.0 PSIG (2.8 BAR); MINIMUM 10 INHG (339 MBAR)] MINIMUM TEMPERATURE 134 C (273 F) 132 C (270 F) EXPOSURE TIME 18 MINUTES 4 MINUTES PURGE - 2-3 MINUTE VACUUM DRYING 20 MINUTES 20 MINUTE These sterilization parameters assume that all instruments have been properly decontaminated prior to sterilization. The parameters are validated to sterilize specifi c confi gurations as noted in the tray markings. If other products are added to the tray or to the sterilizer, the recommended parameters may not be valid and new cycle parameters may need to be validated by the user. The autoclave must be properly installed, maintained and calibrated. Other sterilization method and cycles may also be used. However, individuals or hospitals not using the recommended method are advised to validate the alternative method using appropriate laboratory techniques. EtO sterilization or cold sterilization techniques are not recommended. Information related to postoperative care The patient should be advised that a second more minor procedure for the removal of the implants is usually necessary. While the surgeon must make the fi nal decision regarding implant removal, wherever possible and practical for the individual patient, fi xation devices should be removed once their service as an aid to healing is accomplished. In the absence of a bursa or pain, removal of the implant in elderly or debilitated patients is not suggested. Postoperative instructions to patients and appropriate nursing care are critical. Early weight bearing substantially increases implant loading and increases the risk of loosening, bending, or breaking the device. Patients who are obese or non-compliant, as well as patients who could be predisposed to delayed or non-union must have auxiliary support. Even after full healing, the patient should be cautioned that refracture is more likely with the implant in place and soon after its removal, rather than later, when the voids in the bone left by implant removal have been fi lled in completely. Patients should be cautioned against unassisted activity that requires walking or lifting. Postoperative care and physical therapy should be structured to prevent loading of the operative extremity until stability is evident. The patient should be encouraged to report to his/her surgeon any unusual changes of the operated extremity. If evidence suggests loosening of the implant (particular pain and progressive changes in the radiographs) an intensifi ed schedule of check-ups is advised and new warning and instructions to the patient may be appropriate regarding further activity restrictions. The patient should be encouraged to receive prompt medical attention for any infection that could occur, whether at the operated-member level or elsewhere in the body. Storage Store in dry place. Product information disclosure Liability Newdeal, an Integra LifeSciences Company, has exercised reasonable care in the selection of materials and the manufacture of these products and warrants that the products are free from manufacturing defects. Newdeal excludes all other warranties, whether expressed or implied, including but not limited to, any implied warranties of merchantability or fi tness for a particular purpose.newdeal shall not be liable for any incidental or consequential loss, damage, or expense, directly or indirectly arising from use of this product. Newdeal neither assumes nor authorizes any person to assume for it any other or additional liability or responsibility in connection with these products. Newdeal intends that this device should be used only by physicians having received proper training in orthopedic surgery technique for use of the device. WARNING This device is not approved for screw attachment or fi xation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine. INFORMATION Should any information regarding the products or their uses be required, please contact your representative or distributor or directly contact the manufacturer. 7

Uni CP Compression Plating System Surfix Titanium screw diam. 3.5 mm + lock screw Reference 285 312s Length 12 mm 285 314s Length 14 mm 285 316s Length 16 mm 285 318s Length 18 mm 285 320s Length 20 mm 285 322s Length 22 mm 285 324s Length 24 mm 285 326s Length 26 mm 285 328s Length 28 mm 285 330s Length 30 mm 285 332s Length 32 mm 285 334s Length 34 mm 285 336s Length 36 mm 285 338s Length 38 mm 285 340s Length 40 mm 185 300s Lock screw diam 3 5 mm 1 330 217s 330 225s 330 230s 2 holes 17 mm 2 holes 25 mm 2 holes 30 mm 330 420s 330 425s 330 430s 330 030s 4 holes 20 mm 4 holes 25 mm 4 holes 30 mm 4 holes 20mm T shape 6 8 6 1 2 4 Compression stainless steel plate Reference 7 9 10 11 3 5 Container Instruments Reference Reference 219 835 Screwdriver / Hex diam 2 0 mm, L 180 mm 339 950 Container 2 219 435 Screwdriver / AO, hex diam 2 0 mm, L 76 mm 339 920 Base 3 219 635 Drilling guide, diam 2 7 mm 996 200 Lid 4 219 535 Drill, AO diam 2 7 mm, L 190 mm 169 106 Module 5 115 101 K wire, diam 1 0 mm, L 100 mm 6 219 735 Bending forceps, diam 3 5 mm hole, L 171 mm 7 219 335 Depth gauge, diam 3 5 mm screws 8 339 001 Compression forceps 9 339 004 Implant sizer for T and U plates * 1 10 339 003 Holder 11 339 005 Trial plate for 2 and 4 holes plates 9 Integra LifeSciences Services (France) SAS Sales & Marketing EMEA Immeuble Séquoia 2 97 allée Alexandre Borodine Parc technologique de la Porte des Alpes 69800 Saint Priest FRANCE +33 (0)4 37 47 59 00 fax +33 (0)4 37 47 59 99 emea info@integralife com integralife.com Distributed by Customer Service International: +33 (0)4 37 47 59 50 +33 (0)4 37 47 59 25 (Fax) csemea@integralife com United Kingdom : csuk ortho@integralife com France: +33 (0)4 37 47 59 10 +33 (0)4 37 47 59 29 (Fax) cs ortho@integralife com Benelux: +32 (0)2 257 4130 +32 (0)2 253 2466 (Fax) custsvcbenelux@integralife com Switzerland: +41 (0)2 27 21 23 30 +41 (0)2 27 21 23 99 (Fax) custsvcsuisse@integralife com Newdeal SAS Immeuble Séquoia 2 97 allée Alexandre Borodine Parc technologique de la Porte des Alpes 69800 Saint Priest FRANCE +33 (0)4 37 47 51 51 fax +33 (0)4 37 47 51 52 newdeal@newdeal info www newdeal info 2010 Integra LifeSciences Corporation All rights reserved ILS 08 07 038 02 10 PRODUCTS FOR SALE IN EUROPE, MIDDLE EAST and AFRICA ONLY Availability of these products might vary from a given country or region to another, as a result of specific local regulatory approval or clearance requirements for sale in such country or region Always refer to the appropriate instructions for use for complete clinical instructions Non contractual document The manufacturer reserves the right, without prior notice, to modify the products in order to improve their quality WARNING: Applicable laws restrict these products to sale by or on the order of a physician Surfix, UNI CP, Integra and the Integra logo are trademarks or registered trademarks of Integra LifeSciences Corporation or its subsidiaries