AMS 800 Urinary Control System

Similar documents
AMS 800 Urinary Control System ACTIVATING:

AMS 800. Urinary Control System. User s Guide. Table of Contents. The AMS 800 Urinary Control System...1. Using the AMS 800 Urinary Control System...

A Simple Solution. to a Common Problem. Find relief from sudden, unplanned urine leakage.

Life after prostate cancer End your frustration. Restore your normalcy. Renew your confidence. Take the next step


Penile implants What to expect and how to prepare

CARING FOR YOUR CATHETER AT HOME

Angiogram, angioplasty and stenting

Vesico Ureteric Reflux (VUR)

Bulkamid. Patient Information. Obstetrics & Gynaecology Department

Intermittent self-catheterisation

Pain relief that s better for every body. ON-Q* Pump with ONDEMAND* Bolus Button. myon-q.com. As determined by your doctor

Before and After Your Surgery

Life after prostate cancer. End your frustration. Restore your normalcy. Renew your confidence. Erectile dysfunction and male incontinence

Continence Control System USER S MANUAL

Loss of Bladder Control

One Slim Needle One Incision. One Simple Solution for Stress Urinary Incontinence. The Difference is in the Data

Overactive bladder. Information for patients from Urogynaecology

Intermittent self-catheterisation (ISC) Information for patients Spinal Injuries

Loss of Bladder Control

THE BULKING AGENT WITH LONG-LASTING EFFECT!

National Kidney and Urologic Diseases Information Clearinghouse

Bard: Continence Therapy. Stress Urinary Incontinence. Regaining Control. Restoring Your Lifestyle.

encathopedia Volume 7 PARKINSON S AND THE BLADDER

Pelvic Support Problems

Achieving Independence. A Guide to Self-Catheterization with the Bard Touchless Plus Intermittent Catheter System

Caring for a Nephrostomy and what is Ureteric Stenting

Clean Intermittent Self-Catheterisation (CISC)

You have been booked for a. Flexible Cystoscopy. Under Local Anaesthetic

Guide for Use. Apogee Plus Touch Free Intermittent Catheter System

After care following insertion of suprapubic catheter

Discussions about having a Supra pubic catheter

ZEPHYR SURGICAL IMPLANTS SÀRL

AMS Ambicor. Penile Prosthesis. Operating Room Manual. English

Instructions for Use TRULICITY. dulaglutide solution for injection, for subcutaneous use. 1.5 mg/0.5 ml Single-Use Pen, Once-Weekly

Urogynecology Associates of Philadelphia URODYNAMIC TESTING

Instruction Guide to Clean Intermittent Catheterization for Parents of Boys Using the Hydrophilic Cure Catheter

Lee Jackson, M.D. Post-Operation Information and Instructions

Bladder retraining - treatment for urgency and urge incontinence

INSERTION OF AN ARTIFICIAL URINARY SPHINCTER IN MEN

Suprapubic Catheter Insertion Clinic

Urinary incontinence. Urology Department. Patient Information Leaflet

Managing your suprapubic catheter

q7:480499_P0 6/5/09 10:23 AM Page 1 WHAT YOU SHOULD KNOW ABOUT YOUR DIAGNOSIS OF STRESS URINARY INCONTINENCE

Guide for Use. Advance Plus Touch Free Intermittent Catheter System

THE MEDTRONIC TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) SYSTEM

Before you use the TALTZ autoinjector, read and carefully follow all the step-by-step instructions.

Instructions for Use. For use with. 10 mg vial

Nephrostomy. Radiology Department. Patient information leaflet

Prostate surgery. What is the prostate? What is a TURP? Why is a TURP operation necessary? Deciding to have a TURP operation.

Indwelling urinary catheter

Incontinence. Anatomy The human body has two kidneys. The kidneys continuously filter the blood and make urine.

Glossary of terms Urinary Incontinence

Procedure Specific Information Sheet Open Radical Prostatectomy

Sacral Nerve Stimulation (SNS) System Implantation

Neurogenic Bladder: What You Should Know. A Guide for People with Spinal Cord Injury

Pelvic Floor Muscle Exercises and Advice for Men

Patient information leaflet. Royal Surrey County Hospital. NHS Foundation Trust. Nephrostomy. Radiology

Instruction Guide to Sterile Self-Intermittent Catheterization For Men Using the Cure Catheter Closed System

MANUALFor Operating Room

Patient and Family Education. Bladder Exstrophy. What is bladder exstrophy? How common is bladder exstrophy? What causes bladder exstrophy?

B l a d d e r & B o w e l C a r e. For Patients with Spinal Cord Injuries

Incontinence. Urinary. In Adults. THIS PUBLICATION IS OUT OF DATE. For most current information:

Patient Information Leaflet Guidelines for the use of Rectal Irrigation

Returning Home After Prostatectomy

Surgical treatment of urinary stress incontinence with tension free vaginal tape

What you should know about your diagnosis of incontinence

gentle catheter clip USER GUIDE optimum medical support optimummedical independence with confidence

Pelvic Floor Muscle Exercises and Advice for Men

encathopedia Volume 2 MULTIPLE SCLEROSIS AND THE BLADDER

Robotic Prostatectomy - After Surgery

IF YOU VE GOT TO GO, WE VE GOT SOLUTIONS.

Cystoscopy and urethroscopy

Understanding your treatment options for male stress urinary incontinence and erectile dysfunction

Obstructive Defaecation

Achieving Independence

Indwelling Urinary Catheters And Drainage systems

Instruction Guide to Clean Intermittent Catheterization for Parents of Boys Using the Cure Catheter

Urinary Catheter Passport for patients

Talk about Clean Intermittent Catheterisation (CIC)

How to care for your urethral catheter

Procedures/Risks:central venous catheter

Suprapubic and Mitrofanoff Catheter Care

Instruction Guide to Clean Self-Intermittent Catheterization For Men Using the Hydrophilic Cure Catheter

INL No. A0075 Project Medtronic Patient Information Leaflet Description 16 page booklet

University Hospitals Bristol NHS Foundation Trust NHS. Catheterisation using a Mitrofanoff

User Appreciation of the VaPro Intermittent Catheter Characteristics and Packaging

THE ARTIFICIAL URINARY SPHINCTER:

Having a Ureteric Stent What to expect and how to manage

Apogee. Intermittent Catheter Guide for Use

Women and Men s Health Physiotherapy Pelvic floor exercises for men

This information is intended as an overview only

Child and Family Information Material

Coping with urges and leaks?

Female Urinary Incontinence: What It Is and What You Can Do About It

Intravesical Botox Injections

Information for parents. Selective Salpingogram (SS)

Neuroform Microdelivery Stent System

Voiding Diary. Begin recording upon rising in the morning and continue for a full 24 hours.

Continuous Bladder Irrigation

Transcription:

AMS 800 Urinary Control System 1 DAILY USE: While the cuff is closed, urine stays inside the bladder. To urinate, open the cuff as follows: Feel for the control pump in your scrotum. Stabilize the control pump in the proper place by grasping the tubing above the control pump. Grasp Tubing Control Pump

AMS 800 Urinary Control System 2 Use the other hand to squeeze and release the lower, softer part of the pump several times. Repeat this step until the pump is flat. Once flat, this indicates that the cuff is deflated. The urethra is now open and you can urinate. MR Conditional: 3.0 Tesla Soft Part Rx Only The denoted marks are trademarks or registered trademarks of American Medical Systems, Inc. 2015 American Medical Systems, Inc. All Rights Reserved. an endo international company 1001248r2 02-15 www.americanmedicalsystems.com 1-800-328-3881

AMS 800 Urinary Control System 1 DEACTIVATING: Squeeze and release the lower part of the control pump several times to empty the cuff. (The cuff is empty when the pump remains flat). Then, allow the pump bulb to partially refill for about 30-60 seconds. After allowing the pump bulb to partially refill, firmly press the deactivation button found at the top of the pump.

AMS 800 Urinary Control System 2 When the device is deactivated, a slight indentation will be felt at the center of the soft part of the pump. Deactivation Button MR Conditional: 3.0 Tesla an endo international company Soft Part Rx Only The denoted marks are trademarks or registered trademarks of American Medical Systems, Inc. 2015 American Medical Systems, Inc. All Rights Reserved. 1001248r2 02-15 www.americanmedicalsystems.com 1-800-328-3881

AMS 800 Urinary Control System 1 ACTIVATING: Begin by stabilizing the control pump in the proper place by grasping the tubing above the control pump. Use your other hand to firmly squeeze the sides of the upper, hard part of the pump for several minutes. Squeeze sides of upper, hard part

AMS 800 Urinary Control System 2 Continue stabilizing the control pump by holding the tubing. Give the lower part of the pump a hard, forceful squeeze. This step may need to be repeated if you re not successful the first time. The system should now function normally. MR Conditional: 3.0 Tesla Rx Only The denoted marks are trademarks or registered trademarks of American Medical Systems, Inc. 2015 American Medical Systems, Inc. All Rights Reserved. an endo international company 1001248r2 02-15 www.americanmedicalsystems.com 1-800-328-3881

AMS 800 Urinary Control System User s Guide for Male Patients Table of Contents The AMS 800 Urinary Control System... 1 Using the AMS 800 Urinary Control System.2 Special precautions to take with your AMS 800 Urinary Control System before undergoing a medical procedure... 5 Deactivating the AMS 800 Urinary Control System... 5 Activating the AMS 800 Urinary Control System... 7 When should I contact my doctor?... 9 Where can I get more information about the AMS 800 Urinary Control System?... 11

The AMS 800 Urinary Control System The AMS 800 Urinary Control System is intended for use in the treatment of male urinary incontinence. This device is not for patients who are determined by their doctor to be poor surgical candidates, have permanent blockage of the lower urinary tract or who have uncontrollable contraction of the bladder. Some AMS 800 Urinary Control devices may contain an antibiotic (InhibiZone ). The AMS 800 Urinary Control System consists of three main components: an occlusive cuff, a control pump, and a pressureregulating balloon (Figure 1). These are connected by tubing and are filled with a sterile solution. The cuff works much like a normal sphincter, gently squeezing the urethra (urinary canal) closed to keep urine in the bladder. pressure regulating balloon (PRB) occlusive cuff urethra control pump 1 Figure 1 The device may not be suited for patients who are allergic to the antibiotics contained within the device (rifampin, minocycline or other tetracycline s). Patients with urinary tract infections, diabetes, spinal cord injuries, or skin infections may have an increased risk of infection.

Using the AMS 800 Urinary Control System While cuff is closed, urine stays inside of the bladder. To urinate, the cuff is opened as follows: 1. Feel for the control pump in your scrotum (Figure 2). tubing deactivation button hard part soft part Figure 2 2. Stabilize the control pump in the proper place by gently grasping the tubing above the control pump (Figure 3). Figure 3 2

3. Use the other hand to squeeze and release the lower, softer part of the control pump (Figure 4). Do this several times until the control pump is flat. Figure 4 4. When the lower part of the control pump is flat, it indicates that the fluid that filled the cuff has moved to the pressure regulating balloon (PRB), deflating the cuff (Figure 5). The urethra opens and you can urinate. 3 Figure 5

That is the all the manipulation required to urinate. The fluid automatically returns from the PRB to refill the cuff. Once full, the cuff again squeezes the urethra closed. It usually takes several minutes for the cuff to be filled by the fluid (urethra to be re-closed), but each person is different. After using your AMS 800 Urinary Control System a few times, you will know how long it takes for your cuff to refill. If you feel that you did not empty your bladder completely before the cuff refilled, give the soft part of the control pump a few more squeezes to re-open the urethra. It is a good idea to get into the habit of emptying your bladder on a regular basis, such as every two to three hours. It is important to let someone else, such as your spouse, know how to operate the AMS 800 Urinary Control System to assist you if needed. 4

Special precautions to take with your AMS 800 Urinary Control System before undergoing a medical procedure It is important for healthcare providers to know that you have an AMS 800 Urinary Control System before you undergo any medical procedure. This is especially true of any procedures which require the insertion of a catheter or any other instrument into the urethra. Such procedures can only be safely performed after your AMS 800 Urinary Control System has been deactivated (see the following section for deactivation instructions). Failure to deactivate the AMS 800 Urinary Control System before inserting a catheter or other instrument into the urethra can result in damage to the device and/or your urethra. It is possible that such damage could require removal of the device. Deactivating the AMS 800 Urinary Control System The AMS 800 Urinary Control System has a deactivation button which stops the flow of the fluid from one component to another.your doctor may deactivate your device at various times, such as while you are healing following your surgery or before inserting a catheter or other instrument into your urethra. 5

To deactivate the AMS 800 Urinary Control System: 1. Squeeze and release the lower part of the control pump several times, just as you would do to urinate. 2. After completely emptying the cuff (the cuff is empty when the pump remains flat), allow the pump bulb to partially refill (about 30-60 seconds). When the control pump is partially refilled, firmly press the deactivation button on the top of the control pump. After pressing the deactivation button, you will still feel the button on the upper part of the pump. Pressing the deactivation button locks out the flow of fluid through the control pump. When the device is properly deactivated, a slight indentation will be felt at the center of the soft part of the pump. The cuff will now remain open (Figure 6). deactivation button Figure 6 When the AMS 800 Urinary Control System is deactivated, the cuff around your urethra will not stop the flow of urine. You should use pads while the AMS 800 Urinary Control System is deactivated. What happens if the deactivation button is squeezed accidentally? The device will deactivate and two problems could occur. 6

Fluid may not refill the cuff, so you will keep leaking urine, or fluid may lock in the cuff so you cannot urinate. If either problem occurs, you will notice that the pump feels different from its normal status. You can activate the device to solve these problems. Activating the AMS 800 Urinary Control System It is important that the AMS 800 Urinary Control System remain open while you are healing following your surgery. Closely follow your doctor s instructions about the amount of time before activating the device. To activate the AMS 800 Urinary Control System: 1. Use one hand to grasp the tubing above the control pump to hold the control pump in an appropriate place (Figure 7). 2. Use the other hand to squeeze the sides of the upper, hard part of the control pump, on the side opposite the deactivation button. Be sure to use steady, firm pressure for several minutes. This will cause the lower part of the control pump to become hard and filled with fluid. 7 Figure 7

3. Continue stabilizing the control pump by holding the tubing (DO NOT STABILIZE THE PUMP BY HOLDING THE UPPER, HARDER PART OF THE PUMP DURING THIS STEP. DOING SO WILL MAKE PROPER ACTIVATION EXTREMELY DIFFICULT). Give the lower part of the pump a quick, forceful squeeze (Figure 8). This step may need to be repeated if you re not successful the first time. Because greater pressure is required for activation than for normal operation, you may experience some discomfort while activating the device. The system should now function normally. Figure 8 8

When should I contact my doctor? Contact your doctor if you notice any of the following: Fever Swelling near the incision Redness near the incision Any other signs of infection If the surgical area does not heal Prolonged pain or discomfort If the device can be seen or felt outside of the skin Return of leakage If the device is not working correctly 9

Where can I get more information about the AMS 800 Urinary Control System? Your doctor is the best source for getting more information on the AMS 800 Urinary Control System. Your doctor is most familiar with your medical situation and can work with you to make sure you get the best possible results from the AMS 800 Urinary Control System. Contact your doctor if you have questions or would like to receive additional information. You can also call the AMS patient liaison at 1-800-328-3881, extension 6261, or visit our website at www.americanmedicalsystems.com. 10

American Medical Systems, Inc. U.S. Headquarters 10700 Bren Road West Minnetonka, MN 55343 USA U.S. Toll Free: 800-328-3881 Tel: + 952 930 6000 Fax: + 952 930 6157 www.americanmedicalsystems.com American Medical Systems Europe B.V. Haarlerbergweg 23 G 1101 CH Amsterdam Zuid-Oost The Netherlands Tel: +31 20 593 8800 regulatoryaffairseu@americanmedicalsystems.com Rx Only The denoted marks are trademarks or registered trademarks of American Medical Systems, Inc. 2013 American Medical Systems, Inc. All Rights Reserved. Printed in USA. 600334-01G/August 2013