How to Transfer Your Settings

Similar documents
How to Transfer Your Settings

Getting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite

USING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User

USING THE MINIMED 670G SYSTEM

RELEASED. first steps. Icon Icon name What it means

PATIENT TRAINING CHECKLIST MINIMED 670G SYSTEM

Welcome to CareLink Pro

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

RELEASED. Clearing your active insulin

Report Reference Guide

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

Diabetes Management App. Instruction Manual

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

Getting you up to speed Quick Reference Guide

GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

GETTING STARTED WITH THE MINIMED 640G SYSTEM

Imagine a world... Believe in better control. MiniMed Veo Paradigm System A Step-by-Step Guide

MiniMed 640G System Intelligent for Better Control

Wuxi Apex Medical Co., Ltd. Add: Suit 607, 5Bld., No.7 Changjiang Road, High Tech. Area, Wuxi, Jiangsu, China Tel:

MiniMed 640G System Intelligent for Better Control

MINIMED 640G SYSTEM^ Getting Started WITH CONTINUOUS GLUCOSE MONITORING

GETTING STARTED. Continuous Glucose Monitoring MiniMed 630G System

GETTING STARTED WITH CONTINUOUS GLUCOSE MONITORING

Aviva Combo BLOOD GLUCOSE METER. Advanced Owner s Booklet for Self-Testing Only

BREAKDOWN OF THE CARELINK REPORTS GETTING STARTED WITH CARELINK PERSONAL SOFTWARE

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

5.2mmol/L. 5.2 mmol USER GUIDE. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System

5.2 mmol USER GUIDE. 5.2 mmol/l. Bolus Reminder Notes. 12:00 PM l 10/13. Uses only Contour Next blood glucose test strips.

Using the Bolus Wizard Calculator

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

DURING TRAINING CONTINUOUS GLUCOSE MONITORING MINIMED 630G SYSTEM

MiniMed 530G System User Guide

5.2 mmol USER GUIDE 5.2. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System 12:00 PM METER BG

Contour Diabetes app User Guide

Insulin Pumps Available in Canada

Aviva Combo BLOOD GLUCOSE METER. Getting Started Guide for Self-Testing Only

THERAPY MANAGEMENT SOFTWARE FOR DIABETES. User Guide

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

120 mg USER GUIDE. 120 mg/dl. Bolus Reminder Notes. Uses only CONTOUR NEXT Blood Glucose Test Strips. 12:24 PM l 10/13.

CONTINUOUS GLUCOSE MONITORING SYSTEM. Quick Start Guide

Continuous Glucose Monitoring (CGM) Dexcom G6 Training for Healthcare Professionals and Patients

ssociation of Children s Diabetes Clinicians Clinicians Continuous Glucose Monitoring (CGM) Training for Healthcare Professionals and Patients

BLINDED MODE USERS GUIDE SUPPLEMENT

Understanding the CareLink TM Therapy Management Dashboard Report

Predicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY

User s Manual Blood Glucose Meter

Quick Reference Guide. Sensor Smart Transmitter Mobile App

Paradigm/Guardian CGM Screens. CareLink Online Reports. Make Your Own Jackson Pollack. CGM by Jackson Pollack. How To Read CGM Screens/Reports

Getting Started. with Continuous Glucose Monitoring for the MiniMed 530G with Enlite. CGM Foundations

GETTING STARTED WITH CONTINUOUS GLUCOSE MONITORING

PROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY

DISCOVER THE POWER OF CONNECTION MINIMED 640G

NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP

Getting Started. with Continuous Glucose Monitoring. Learning Guide

Understanding the CareLinkTM Sensor Meter Overview Report: Page 1

Seven Simple Steps to Start. Your Dexcom G4 PLATINUM System

Continuous Glucose Monitoring System. Receiver Setup

GETTING STARTED WITH THE MINIMED 640G SYSTEM

Table of Contents. Contour Diabetes App User Guide

Home Glucose Monitoring

GETTING STARTED WITH THE MINIMED 640G SYSTEM

IMPORTANT SAFETY INFORMATION

Data Management System (DMS) User Guide

Wireless Blood Glucose Monitoring System. 93 mg 12:24 PM METER BG. Mg/dL. Uses only CONTOUR NEXT blood glucose test strips from Bayer USER GUIDE

Medical Education. Personal Continuous Glucose Monitoring Protocol. Innovating for life.

Imagine a world... Believe in better control. MiniMed Veo Paradigm System. A Practical Guide to Continuous Glucose Monitoring

User s Manual Blood Glucose Meter

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:

Diabetes Devices Workshop Angela Aldrich, PharmD, PhC April Mott, PharmD, PhC, BCPS Presbyterian Medical Group 28 January 2018

DIABETES MANAGEMENT PLAN 2017

Report reference guide. mmol/l. One. solution EMR. No fuss

Comparative table of insulin pumps

Blood Glucose Monitoring System. Copyright 2016 Ascensia Diabetes Care Holdings AG diabetes.ascensia.com

Caregiver Guide WITH THE OMNIPOD. MyOmniPod.com RYAN OMNIPOD WEARER

COROS APEX Watch User Manual

CARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT CARELINK REPORTS GUIDE

USER GUIDE BEST LIFE Insulin Pump

POPULATION TRACKER MIDS USER GUIDE

SIMPLE, NON-STOP INSULIN DELIVERY FOR PEOPLE WITH DIABETES WHO INSIST LIFE STILL COMES FIRST. HEALTHCARE PROFESSIONAL BROCHURE

GLOOKO FOR ios MIDS USER GUIDE

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE

MINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD

CONTINUOUS GLUCOSE MONITORING SYSTEM. Receiver with Share TM USER S GUIDE

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use

Live life, less complicated. InPen MOBILE APP. Healthcare Provider INSTRUCTIONS FOR USE. CompanionMedical.com

G4-Global Continuous Glucose Monitoring System

Abbott FreeStyle Libre Pro System

Insulin Pump An information session to help you decide if you are ready to use an insulin pump.

Interpreting the charts & graphs

WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS?

Understanding the Assessment and Progress Report

USER S GUIDE DEXCOM G4 PLATINUM CONTINUOUS GLUCOSE MONITORING SYSTEM

First steps for success.

THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA

CONTINUOUS GLUCOSE MONITORING SYSTEM. Receiver with Share TM USER S GUIDE

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

Therapy Management Software for Diabetes

Making the Most of Continuous Glucose Monitoring

Transcription:

How to Transfer Your Settings for your Replacement MiniMed 530G System Let s get started! Step 1: Before you send your original pump back, copy your current settings onto the Insulin Pump Settings Form. If for any reason you cannot copy the settings please contact your Healthcare Provider or reference your CareLink reports. Step 2: Insert a AAA battery into your new pump. Be sure not to use a rechargeable or lithium battery. Step 3: Follow the instructions found on pages 2 through 5 to program the settings that you have recorded on the Insulin Pump Settings Form into your new pump. A CHECK SETTINGS alarm will occur after the first time you rewind your new pump. Press then to clear the alarm. For more information on pump features and settings, please reference the MiniMed 530G System User Guide. Online Learning Resources Medtronic has a rich library of online training classes available through mylearning. There you can find classes on advanced pump and continuous glucose monitoring features. To browse the class catalog for a full list of offerings, login to mylearning at my.medtronicdiabetes.com/mylearning

MiniMed 530G Insulin Pump Settings Form Record your current pump settings to transfer them to your new MiniMed 530G insulin pump. Basal Settings Main > Basal > Basal Review Max Basal Rate: U/H Basal Rates: 1. 12:00AM U/H 2. U/H 3. U/H 4. U/H 5. U/H 6. U/H Temp Basal Type: U/H Percent of Basal Basal Pattern A: 1. 12:00AM U/H 2. U/H 3. U/H 4. U/H Basal Pattern B: 1. 12:00AM U/H 2. U/H 3. U/H 4. U/H Sensor Settings Main > Sensor > Review Settings SENSOR: On Off Glucose Limits: 1. 12:00AM - mg/dl 2. - mg/dl 3. - mg/dl 4. - mg/dl Hi Repeat: minutes hour Lo Repeat: minutes hour Predictive Alerts: Low: On Off min High: On Off min Rate of Change Alerts: Fall Rate: Off On mg/dl/min Rise Rate: Off On mg/dl/min Threshold Suspend: Off On mg/dl Cal Repeat: min. Cal Reminder: minutes hour Transmitter ID: Weak Signal: minutes Bolus Settings Main > Bolus > Bolus Setup > BW Setup > Review Settings Wizard: On Off Carb Units: Grams Exch Carb Ratios: 1. 12:00AM grams/u 2. grams/u 3. grams/u 4. grams/u Sensitivity: 1. 12:00AM mg/dl/u 2. mg/dl/u 3. mg/dl/u 4. mg/dl/u BG Target Ranges: 1. 12:00AM - mg/dl 2. - mg/dl 3. - mg/dl 4. - mg/dl Active Insulin Time: Hrs Main > Bolus > Bolus Setup Max Bolus: units Scroll Rate: 0.025 0.05 0.1 Dual/Square Option: On Off Easy Bolus: On/Set units Off BG Reminder: On Off Missed Bolus Reminder: On Off 1. - 2. - 3. - 4. - Utilities Main > Utilities > Alarm Alert Type: Beep Long Beep Medium Beep Short Vibrate Auto Off: Hrs Low Reservoir: Units Time Main > Utilities > Connect Devices Connect Devices: PC Connect Meter ID Remote ID Main > Utilities > Capture Option Capture Option: On Off 1

Steps to Program your Replacement 530G Insulin Pump When your pump is idle, press to access the Main Menu. Setting Time and Date Main > Utilities 1. Scroll to Time/Date and press. 2. Select 12-hour (AM/PM) or 24-hour (military time) and press. 3. Press to change the Time/Date. 4. Use and to set the hour. If 12-hour was selected, make sure you scroll through the hours until AM or PM time is set correctly. 5. Press to set. 6. Repeat steps 4 and 5 to set the minutes, year, month, and day. A prompt will appear asking if time and date are correct. If they are, highlight Yes and select. A CHECK SETTINGS alarm will also sound; clear the alarm by pressing and then. Setting Max Basal Rate Main > Basal > Basal Setup 1. Select Max Basal Rate. Press. 2. Use and to set MAX BASAL RATE amount. 3. Press. Setting Basal Rates Main > Basal 1. Scroll to Basal Setup. Press. 2. Set/Edit Basal is highlighted. Press. 3. Use to set the basal rate amount. Press. 4. If setting one basal rate, press to finish. 5. Use and to SET START TIME 2. Press. 6. Use and to SET BASAL RATE 2. Press. 7. Repeat step 5 and 6 as needed. Press to skip final START TIME. 8. BASAL RATE screen appears showing the current rate (U/H); start time and 24 hour basal total. Setting Max Bolus Main > Bolus > Bolus Setup 1. Select Max Bolus. Press. 2. Use and to set MAX BOLUS amount. 3. Press. 2

Steps to Program your Replacement 530G Insulin Pump Turn Turn Bolus Bolus Wizard Wizard On: On: Main > Bolus > Bolus Setup 1. Select Bolus Wizard Setup. Press. 2. Select Edit Settings. Press. 3. Select Wizard: Off. Press. 4. Select On. Press. Program Bolus Wizard Settings: Main > Bolus > Bolus Setup > Bolus Wizard Setup > Edit Settings 1. Highlight Carb Units. Press. 2. Select Grams or Exchanges and press. 3. Highlight Carb Ratios. Press. 4. Use and to set Carb Ratio. Press. 5. If setting more than one Carb Ratio, use and to SET START TIME 2, otherwise, press to finish. 6. Highlight Sensitivity. Press. 7. Use and to set Sensitivity. Press. 8. If setting more than one Sensitivity, use and to SET START TIME 2, otherwise, press to finish. 9. Highlight BG Target. Press. 10. Use and to set Low and High Target. 11. Press after each one. 12. If setting more than one Target Range, use and to SET START TIME 2, otherwise, press to finish. 13. Highlight Active Ins Time. Press. 14. Use and to set Time. Press. 15. Press to finish programming your Bolus Wizard Settings. Bolus Wizard Setup is complete message appears. Note: The settings shown are for illustration purposes only your settings may be different. 3

Steps to Program your Replacement 530G Insulin Pump Programming the Sensor Features: Turn Sensor On: Main > Sensor 1. Press on Edit Settings. 2. Press on Sensor. The SENSOR ON/OFF screen appears. 3. Highlight On and press. Turn Glucose Alerts on: Main > Sensor > Edit Settings 1. Highlight Glucose Alerts and press. 2. On the GLUCOSE ALERTS screen, highlight On and press. Set Low and High Glucose Limits: Main > Sensor > Edit Settings > Glucose Limits 1. Use and to change Low Glucose Limit and press. 2. Then use and again to change High Glucose Limit and press. 3. SET START TIME 2 appears. Press if you do not have additional Glucose Limits to set. Otherwise, use and to set the time and press. 4. Repeat steps 1 through 3 to set the remaining limits. Set Low and High Repeat: Main > Sensor > Edit Settings > Hi Repeat 1. Use and to set High Repeat time and press. Main > Sensor > Edit Settings > Lo Repeat 1. Use and to set Low Repeat time and press. Set Predictive Alerts: Main > Sensor > Edit Settings > Predict Alerts 1. Use and to set Low Predictive time and press. 2. Repeat step to set High Predictive time and press. Set Fall and Rise Alerts: Main > Sensor > Edit Settings > Rate Alerts 1. Use and to set prescribed Fall Rate and press. 2. Repeat this step to set Rise Rate. Turn to page 5 to continue setting sensor settings 4

Set Threshold Suspend, Calibration and Transmitter Set Threshold Suspend: Set Threshold Suspend: Main > Sensor > Edit Settings > Sensor > Thresh. Suspend 1. Press to turn Threshold Suspend On. 2. Use and to set Suspend Threshold and press. Set Calibration Repeat: Main > Sensor > Edit Settings > Cal Repeat 1. Use and to set Calibration Repeat time and press. Set Calibration Reminder: Main > Sensor > Edit Settings > Cal Reminder 1. Highlight On and Press. 2. Use and to set Calibration Repeat time and press. Set Transmitter ID: Main > Sensor > Edit Settings > Transmitter ID 1. Use and to enter each digit and press. Linking your Meter: Main > Utilities > Connect Devices > Meters 1. To turn on meter option, highlight On and press. 2. Select Add ID and press. 3. Use and buttons to enter the six ID characters of your meter and press after each number. After you set the final character, the screen will return to the METER ID menu. Please take some time to review ALL your entries and ensure they are correct. For Technical Assistance: Call Medtronic 24-Hour HelpLine 800-646-4633 For Medical Advice: Call Your Healthcare Team 530G, Bolus Wizard, MiniMed, CareLink, are registered trademarks of Medtronic MiniMed, Inc. 950M13047-011 20141017 2014 Medtronic MiniMed, Inc. All rights reserved. 5