Andrew Karellas, PhD

Similar documents
Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Digital Breast Tomosynthesis from a first idea to clinical routine

CURRENTLY FDA APPROVED ARE FULL FIELD DIGITAL MAMMOGRAPHY SYSTEMS AND FILM SCREEN STILL BEING USED AT SOME INSTITUTIONS

Radiation Dosimetry in Digital Breast Tomosynthesis. March, 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist

Fundamentals of Breast Tomosynthesis

Opportunities and Innovations in Digital Mammography John M. Sandrik, Ph.D. GE Healthcare Milwaukee, WI

8/3/2016. DBT Physics Basic to Advanced: Primer On Tomosynthesis. Tomosynthesis Pedigree

TOMOSYNTHESIS: WORTH ALL THE HYPE?

Update of Digital Breast Tomosynthesis. Susan Orel Roth, MD

Since its introduction in 2000, digital mammography has become

Financial Disclosures

Disclosures. Outline. Learning Objectives. Introduction. Introduction. Stereotactic Breast Biopsy vs Mammography: Image Quality and Dose.

Contrast Enhanced Spectral Mammography (CESM) Updates

#46: DIGITAL TOMOSYNTHESIS: What is the Data Really Showing? TERMS (AKA) WHAT IS TOMOSYNTHESIS? 3/3/2014. Digital breast tomosynthesis =

Innovations and Applications of Tomosynthesis. Andrew D. A. Maidment, Ph.D. University of Pennsylvania Department of Radiology

What s New in Breast Imaging. Jennifer A. Harvey, M.D., FACR Professor of Radiology University of Virginia

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Mammography. What is Mammography?

Breast Tomosynthesis An additional screening tool in the fight against breast cancer

Breast Tomosynthesis. What is breast tomosynthesis?

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

The power and promise of breast tomosynthesis is here. Selenia Dimensions system with Acquisition Workstation 5000

Implementation of a New Tomosynthesis Program: A Physicists Perspective

SenoBright Contrast Enhanced Spectral Mammography Technology. Ann-Katherine Carton Sylvie Saab-Puong Matt Suminski

Diagnostic Medical Physicist Via Christi Hospitals Wichita, Wichita, KS

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

WHAT TO EXPECT. Breast Tomosynthesis An additional screening tool in the fight against breast cancer HOLOGIC. The Women's Health Company

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Patient Dosimetry in Mammography and Tomosynthesis:

Outline. Digital Breast Tomosynthesis: Update and Pearls for Implementation. Tomosynthesis Dataset: 2D/3D (Hologic Combo Acquisition)

Digital breast tomosynthesis

Breast tomosynthesis reduces radiologist performance variability compared to digital mammography

Policy Library Clinical Advantages of Digital Breast Tomosynthesis in Symptomatic Patients

Volume 14 - Issue 3, Matrix

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

Digital Breast Tomosynthesis: A Technological Review

X-Ray & CT Physics / Clinical CT

Contrast-Enhanced Breast Tomosynthesis: Combining the Best of Both Worlds for Better Breast-Cancer Diagnosis

WOMEN S HEALTH SOLUTIONS. The power and promise of breast tomosynthesis is here. Selenia Dimensions system with Acquisition Workstation 8000

Breast CT and Dosimetry

MRI-guided near-infrared spectroscopy of breast tumors

Mammography. What is Mammography? What are some common uses of the procedure?

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

B R E A S T I M A G I N G S O L U T I O N S. Selenia Dimensions A Revolution in Breast Imaging

Updates in Mammography. Dr. Yang Faridah A. Aziz Department of Biomedical Imaging University Malaya Medical Centre

CASE STUDIES. Population. Compression

ACR MRI Accreditation: Medical Physicist Role in the Application Process

Tomosynthesis and breast imaging update. Dr Michael J Michell Consultant Radiologist King's College Hospital NHS Foundation Trust

Corporate Medical Policy

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

Hacia la imagenología tomográfica de mama

Objectives. Explanation of Radiation Dose Terminology 10/9/2018. What are these lines?

FDA Executive Summary

Here are examples of bilateral analog mammograms from the same patient including CC and MLO projections.

3D Mammography. The most exciting advancement in mammography in over 30 years

the one name in cancer care.

Dose reduction in Hologic Selenia FFDM units through AEC optimization, without compromising diagnostic image quality.

Verification of micro-beam irradiation

Image processing mammography applications

Contrast-Enhanced Digital Mammography

Impact of digitalization of mammographic units on average glandular doses in the Flemish Breast Cancer Screening Program

Mammography Quality Control: A Refresher

Contrast-Enhanced Spectral Mammography

Direct half value layer measurements in mammography - is near enough good enough?

Molecular Breast Imaging: History and Recent Developments

Breast positioning system for full field digital mammography and digital breast tomosynthesis system

Computed tomography Acceptance testing and dose measurements

Cone-Beam CT for MSK Extremities

The latest developments - Automated Breast Volume Scanning. Dr. med. M. Golatta

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Advice Statement 005/18 April 2018

MQSA Physicist Qualifications. Jon J. Erickson, Ph.D., DABR

Breast Tomosynthesis

Emerging Techniques in Breast Imaging: Contrast-Enhanced Mammography and Fast MRI

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Update on the ACR FFDM QC Manual

Contrast enhanced spectral mammography: A literature review

Current Status of Supplementary Screening With Breast Ultrasound

CenSSIS Multimode Cancer Imaging via Digital Breast Tomosynthesis

Assessment of extent of disease: digital breast tomosynthesis (DBT) versus full-field digital mammography (FFDM)

Screening Mammograms: Questions and Answers

Look differently. Invenia ABUS. Automated Breast Ultrasound

Dual-Energy Imaging of Bone Marrow Edema on a Dedicated Multi-Source Cone-Beam CT System for the Extremities

Aceso Dual-Modality Imaging. Early detection of cancer in dense breasts. Full-field digital mammography and automated breast ultrasound in one system

Does the synthesised digital mammography (3D-DM) change the ACR density pattern?

Update on MQSA and Mammography Accreditation

Photoacoustic array imaging of calcifications: phantom study

PACS: ERGONOMIC CONSIDERATIONS 1

INTRODUCTION. Breast cancer is an epidemic that affects more than 200,000 new patients each year. With greater than

Accounting for Imaging Dose

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SATURDAY CURRICULUM

Multicenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening

THE DIAGNOSTIC WORKUP: THE TEAM APPROACH

A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

Breast Cancer Imaging

Clinical Policy: Digital Breast Tomosynthesis Reference Number: CP.MP.90

Transcription:

Advanced Imaging for Breast Cancer: Screening, Diagnosis, and Assessing Response to Therapy The Role of Tomosynthesis Andrew Karellas, PhD Department of Radiology University of Massachusetts Medical School Worcester, MA Andrew.Karellas@umassmed.edu AAPM 2013 Indianapolis WE A 141 01 1

Acknowledgments NIH NCI grant R21 CA 134128 (Karellas, UMass) NIH NCI grant R01 CA128906 (Vedantham, UMass) R01 CA139449-01 (Paulsen-PI, Dartmouth) The contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIH or the NCI. Mark Williams, PhD, University of Virginia Otto Zhou, PhD, University of North Carolina Andrew Tucker, graduate student, University of North Carolina Bob Liu, PhD, Massachusetts General Hospital Disclosures University based NIH funded collaboration with Dartmouth College. Hologic, Inc. is involved in this research. 2

Collaborators UMass Medical School Srinivasan Vedantham, PhD Linxi Shi, MS Stephen Glick, PhD Gopal Vijayaraghavan, MD Sarwat Hussain, MD Thayer School of Engineering at Dartmouth Keith Paulsen, PhD Brian Pogue, PhD Venkat Krishnaswamy, PhD Kelly Michaelsen (med student, PhD candidate) 3

Objectives 1. Rationale for the use of breast tomosynthesis 2. Evolution of breast tomosynthesis from digital mammography 3. Technical requirements Projection geometry X-ray generation, kvp, ma, x-ray spectra Hardware, acquisition modes, spatial resolution 4. Image characteristics, clinical applications 5. Future applications Fusion with molecular imaging Stationary x-ray sources Combination with optical imaging 4

Why do we need breast tomosynthesis? Didn t digital mammography deliver on its objectives? What were these objectives? Health care objectives Improved sensitivity Improved specificity Dose reduction Technological objectives Improved contrast Improved penetration in dense tissue Dynamic range Archival, communication, CAD 5

Increased sensitivity (dense breasts) Improved contrast Reduced dose but.. Digital Mammography It is still limited by superposition of tissues, particularly in the dense breast. How can this limitation be overcome? Develop tomographic capability 6

Digital Breast Tomosynthesis 7

Digital Breast Tomosynthesis X-ray source X-ray beam Compressed breast 4 mastectomy specimens 7-9 views, 30 40 total arc of tube motion Mo target, Mo filter, 26 kvp, 126 mas Dose: up to 1.74 times of mammography technique Breast lesions X-ray detector First digital breast tomosynthesis study. Niklason LT et al. Digital tomosynthesis in breast imaging. Radiology. 1997 205(2):399-406. 8

Subsequent Study on Breast Tomosynthesis S. Suryanarayanan, A. Karellas, S.Vedantham, SJ Glick SJ, CJ D'Orsi, SP Baker, RL Webber RL. Comparison of Tomosynthesis Methods Used with Digital Mammography. Acad. Radiol. 2000; 7:1085-1097. Conclusion The contrast-detail trends of all the tomosynthesis methods analyzed in this study were better than those of planar mammography. Further optimization of the algorithms could lead to better image reconstruction, which would improve visualization of valuable diagnostic information 9

Digital Mammography LCC Tomosynthesis LCC A clinical case showing 1.6 cm low-grade invasive ductal carcinoma with minor ductal carcinoma in situ (DCIS) component. Courtesy of Steven P. Poplack, Dartmouth Hitchcock Medical Center. Karellas A, Vedantham S. Med Phys. 2008 Nov;35(11):4878-97. 10

Tomosynthesis Geometry X-ray source motion 1 15 X-ray projections Breast Center of rotation Detector Scan arc 15 (± 7.5 from center) * 15 projections Antiscatter grid is not used Detector tilt (about 5 ) Other approaches 25º (±12.5 ), 9 projections 25 projections 10 Projections *Based on the Hologic approach 11

Tomosynthesis: X-ray Generation Tungsten x-ray target and aluminum filtration (W/Al) Tube potential: 25 to 49 kvp Tube current: 200 ma maximum Auto-exposure adjusts kvp and pulse width from 10 50 msec Total scan angle: 15º arc (±7.5 ), 15 projections, scan in less than 4 seconds Intensity (ma) modulation is not used 12

Breast Tomosynthesis : X-ray Detection Pixel size 2D: 70 microns Detector: a-se, ~ 24 x 29 cm Detector readout: 4 frames/sec 2x2 pixel binning mode (140 micron pixel) Detector moves slightly during scan Automatic exposure control: 5 x 14 cm, shifted to follow the breast Continuous movement with 30 msec 50 msec per exposure, 15 exposures Data sampling Reconstruction size: ~ 100 microns Reconstructed slice thickness: ~ 1 mm 13

X-Y Plane Resolution - 2D Acquisition Performance: 9 lp/mm can be resolved No depth information 14

X-Y Plane Resolution - 3D Acquisition Performance: 4 lp/mm pattern can be resolved Depth information available Courtesy of Dr. Bob Liu 15

Dose using ACR Phantom AGD ~ 1.2 mgy (2D) AGD ~ 1.4 mgy (Tomo) Courtesy of Dr. Bob Liu In agreement with S. Feng and I. Sechopoulos: Radiology: 2012; 263: 35-42 16

Tomosynthesis is an extension of digital mammography. It is commonly called 3D imaging. Is it fully 3D imaging? Does it matter? 17

Digital Mammography RCC RMLO Courtesy of Gopal Vijayaraghavan, MD, UMass Radiology 18

Digital Mammography RCC Tomosynthesis RMLO Courtesy of Gopal Vijayaraghavan, MD, UMass Radiology 19

Digital Mammography RMLO Tomosynthesis RMLO Diagnosis: Intraductal carcinoma Courtesy of Gopal Vijayaraghavan, MD, UMass Radiology 20

Ultrasound Courtesy of Gopal Vijayaraghavan, MD, UMass Radiology 21

Recent Developments and Future Directions Synergistic approaches Combination with molecular imaging X-ray source arrays, stationary x-ray sources Combination with optical imaging Disclaimer: The equipment and techniques described in the slides that follow are experimental and they are not FDA approved 22

Combination with molecular imaging Courtesy of Mark Williams, PhD Williams M B et al. Radiology 2010;255:191-198 2010 by Radiological Society of North America 23

Tomosynthesis Molecular Breast Imaging Merged High grade DCIS Courtesy of Mark Williams, PhD Williams M B et al. Radiology 2010;255:191-198 2010 by Radiological Society of North America 24

Stationary Digital Breast Tomosynthesis LEFT: Hologic Selenia Dimensions Unit Digital Breast Tomosynthesis system with single rotating x-ray source RIGHT: Stationary digital breast tomosynthesis system with integrated CNT x-ray source array (XinRay Systems Inc. Research Triangle Park, NC). There are 31 x-ray generating focal spots; each x-ray beam can be electronically controlled to turn on/off instantaneously. Tucker AW, Lu J, Zhou O. Med Phys. 2013 Mar;40(3):031917. Courtesy of Dr. Otto Zhou, University of North Carolina 25

Stationary x-ray sources: Spatial Resolution (a) The projection MTFs of the stationary and rotating gantry DBT systems along the scanning direction. (b) The system MTF obtained using reconstructed in-focus slice. Courtesy of Dr. Otto Zhou, University of North Carolina Med. Phys. 39, 2090 (2012) 2012 American Association of Physicists in Medicine

Tomosynthesis with stationary x-ray sources Multiple stationary x-ray sources Multiple stationary sources with a main high power x-ray source Main high power x-ray source X-ray projections Breast Detector 27

Combination with optical imaging NIR Spectral Tomography (NIRST) and Tomosynthesis 28

Venkat Krishnaswamy Brian Pogue Keith Paulsen Michael Mastanduno Shudong Jiang Scott Davis Optics in Medicine Group Steven Poplack Tracy Frazee Barbara Van Houten Joyce Wagner Srinivasan Vedantham Andrew Karellas Linxi Shi Ian Shaw Ken Defreitas Ken Brooks Albert Cerussi Hosain Haghany Keunsik No Brian Hill Funding Sources: NIH R01CA139449 NIH F30CA168079

Imaging at multiple wavelengths allows quantification of tissue chromophores Diffuse Imaging MRI Guided Imaging Carpenter et al,medicamundi, 2009 30

Tomosynthesis with near-infrared X-Ray Source NIR Scanning Source Compression Paddle Breast phantom X-Ray Detectors Hologic, Inc. Older Experimental, not current clinical system Thayer School of Engineering at Dartmouth and UMass Collaboration Courtesy of Kelly Michaelson, Venkat Krishnaswamy Brian Pogue, Keith Paulsen. 31

Near Infrared Light Source Scans Tissue Surface Courtesy of Kelly Michaelson, Venkat Krishnaswamy, Brian Pogue, Keith Paulsen. Thayer School of Engineering at Dartmouth 32

NIR Detector- Made up of 75 cm by cm silicon photodiodes from Hamamatsu, Many detector measurements made at each source position. Courtesy of Kelly Michaelson, Venkat Krishnaswamy, Brian Pogue, Keith Paulsen. Thayer School of Engineering at Dartmouth 33

Near Infrared Light Detectors Detect Signal Beneath the Breast Detector panel can be easily slid underneath the breast before the patient arrives and then removed in a couple of seconds prior to the X-ray imaging. This detector cover was designed in conjunction with Hologic to maintain clinical quality dbt scans. A number of breast mimicking phantom studies were performed to characterize the ability of the system to recover changes in hemoglobin, after which we began our first patient imaging scans. Courtesy of Kelly Michaelson, Venkat Krishnaswamy, Brian Pogue, Keith Paulsen. Thayer School of Engineering at Dartmouth 34

NIR Spectral Tomography (NIRST) and Tomosynthesis Near Infrared Scan NIR Detector Panel Removed DBT Scan IRB-approved study 8/7/2013 Thayer School of Engineering at Dartmouth 35

Metabolic Properties in Normal Subjects Show Expected Physiological Values Normal Subject Courtesy of Kelly Michaelson, Venkat Krishnaswamy, Brian Pogue, Keith Paulsen. Thayer School of Engineering at Dartmouth 36

Lesion segmentation Effective image segmentation is critically important to preserve edge and circumvent out of slice artifacts Srinivasan. Vedantham, Linxi Shi, et al. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:6188-91. Edge preserving out of slice artifact reduction using a Kernel Fuzzy c mean(kfcm) algorithm. Related reference W. Chen, M. L. Giger, and U. Bick, " Academic Radiology, vol. 13, pp. 63-72, Jan 2006. 37

Conclusions on Breast Tomosynthesis Provides limited but clinically useful tomographic detail Spatial resolution in the z-direction is limited (concern about detection of subtle microcalcifications) Currently it cannot be used without mammography 3D information is not fully 3D. Reconstruction in arbitrary planes is not available. 38

Conclusions on Breast Tomosynthesis Average glandular dose is comparable to mammography and about 2x mammography in combination with mammography Convenient platform for molecular imaging (radionuclide or optical) Challenge: Insurance may not pay Future: Stationary x-ray sources 39

40

Med. Phys. 35(2) p. 409 February 2008 41