IRMER Ionising Radiation Medical Exposure Regulations

Similar documents
IONISING RADIATION REGULATIONS 99

Health and Safety Policy Arrangements: Radiation Protection Guidelines

The checklist for the use of Ionising Radiation in Primary Dental Care. Not fully compliant

Information and Guidance

SUMMARY AND EXTRACTS FROM THE 2010 GUIDANCE ON THE SAFE USE OF DENTAL CONE BEAM CT (COMPUTED TOMOGRAPHY) EQUIPMENT

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

On successful completion of the Unit the learner will be able to:

Ionising Radiation Policy

BRITISH SOCIETY OF DENTAL AND MAXILLOFACIAL RADIOLOGY CORE CURRICULA IN DENTAL RADIOGRAPHY AND RADIOLOGY FOR THE DENTAL TEAM

Step by Step Guidance on how to Conduct a Clinical Audit in. Dental Radiography Core Subject

Ionising Radiation Policy

making a referral for breast imaging Standard Operating Procedure

Essential CPD for the dental team

IONISING RADIATION POLICY (for the Safe Use of)

Higher National Unit specification: general information

The Royal College of Radiologists, August 2000 This Publication is Copyright under the Berne Convention and the International Copyright Convention.

Trust Policy 218 Ionising Radiation Safety Policy

Code of Practice for Radiation Protection in Dentistry. Code of Practice For Radiation Protection in Dentistry

DIRECT ACCESS - Guidance to BSDHT Members

Doses to Patients arising from Dental X-ray Examinations in the UK, A Review of Dental X-ray Protection Service Data

TEST GDP DCP. Dental Hygienists and Therapists. Radiography and Radiation Protection. Radiography and Radiation Protection IR(ME)R 2000

Primary Care Dental Services Clinical Governance Framework. May 2006 (Updated)

1. NHS (GENERAL DENTAL SERVICES) (SCOTLAND) AMENDMENT REGULATIONS AMENDMENT NO 136 TO THE STATEMENT OF DENTAL REMUNERATION

RADIATION SAFETY POLICY. Controlled Document Number: Version Number: 3 Controlled Document Sponsor: Controlled Document Lead: Approved By:

CPD l Continuing Professional Development

Enhanced Continuing Professional Development and Personal Development Planning

The Professional Relationships Associated with the Practice of Dental Therapy Practice Standard

Document Control Report

Ionising Radiation Safety Type: Policy Register No: Status: Public. For compliance with the Ionising Radiations Regulations 1999

The College of Dental Surgeons of Saskatchewan Radiation and Imaging Standard

The Radiation Health and Safety Act, 1985

SFHOH4 SQA Unit Code H4PX 04 Contribute to the production of dental images

Template Standard Operating Procedure For: Handling of Midazolam and other controlled drugs in Dental Practices

Specialist List in Special Care Dentistry

A Study of dose Distribution and Radiation Protection in Industrial Radiography in Ireland

Integrated Research Application System (IRAS)

Guided learning hours It is recommended that 15 hours should be allocated for this unit, although patterns of delivery are likely to vary.

Performers List Validation by Experience (PLVE) NHS Performers List Applications. Competency Evidence Checklist

Dental Radiography Core Subject. Digital Radiography

A Guide to IR(ME)R for Referrers

Radiological Analysis - Normal Operation

CERTIFICATE IN ORTHODONTIC NURSING

Performers List Validation by Experience (PLVE)

Procedure. Identify all possible radiation hazards.

CLINICAL AUDIT OF DENTAL RADIOGRAPHY

DIPLOMA IN SPECIAL CARE DENTISTRY

STATE OF IDAHO BOARD OF DENTISTRY

Proposed Radiation Safety Regulations: Submission form

Ionising Radiations Regulations 2017

CHAPTER Committee Substitute for Committee Substitute for Senate Bill No. 2760

Notice of Scopes of Practice and Prescribed Qualifications

COMPETENT AUTHORITY (UK) MEDICAL DEVICES DIRECTIVES GUIDANCE NOTES FOR MANUFACTURERS OF DENTAL APPLIANCES

Receptor dose and Patient Dose in Radiographic exposures - a 15 year review

RADIOGRAPHY & RADIATION PROTECTION

CERTIFICATION OF PERSONNEL IN RADIATION SAFETY AND PROTECTION

IONISING RADIATIONS REGULATIONS 2017 REGULATIONS 5, 6, AND 7. NOTIFICATION, REGISTRATION AND CONSENT

SINGLE USE MEDICAL DEVICES POLICY

THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH IMPORTANT ANNOUNCEMENT ON THE DISCONTINUATION OF THE PART I EXAMINATION

REGULATION (EC) No.141/2000

Medical Devices Act 1

PCN-ISO GEN Requirements for the Qualification of personnel for Limited Applications of Non-destructive Testing

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

CERTIFICATE IN SPECIAL CARE DENTAL NURSING

Radiation Safety & Determining Need for Radiographs

Notice of Scopes of Practice and Prescribed Qualifications

THE COLLEGE OF DENTAL SURGEONS HONG KONG. Regulations. relating to. FCDSHK Intermediate Examination. the Specialty of Family Dentistry

DIRECT ACCESS Guidance to BSDHT Members

Draft Continuing Professional Development Rules Order of Council Public Consultation

BCC DENTAL HYGIENE DEPARTMENT PATIENT S RIGHTS AND CONSENT PACKET STANDARDS OF PATIENT CARE PATIENT S RIGHTS FOR DH CARE

Ionising Radiation Policy

IPEM Recommendations for the Provision of a Physics Service to Radiotherapy

Approval of Dosimetry Services in Ireland Guidelines for Applicants

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP)

WORKERS IN A NUCLEAR FACILITY

An overview of Patient Group Directions (PGDs)

Number 40 of Irish Sign Language Act 2017

Diploma in Implant Dentistry Opportunities 2014

Carolyn Costigan and Andrea Shemilt Nottingham University Hospitals NHS Trust

GUIDELINES ON IONISING RADIATION DOSE LIMITS AND ANNUAL LIMITS ON INTAKE OF RADIOACTIVE MATERIAL

Questions for ionising radiation applications

Occupational Health and Safety Act, 1993

RADIATION PROTECTION NO 175

International Journal of Radiation Research, January 2017

L A W ON RADIATION PROTECTION OF THE REPUBLIC OF LITHUANIA

Level 3 Diploma in Dental Nursing ( /91) January 2014 Version 2.1 (September 2016)

CHAPTER 40 PROFESSIONAL LICENSING AND FACILITY REGULATION

icat Precise Policy and Procedure Manual

Information about cases being considered by the Case Examiners

Level 3 Diploma in Dental Nursing ( /91) August 2017 Version 2.2

National Dental Advisory Committee

SECTION PRESCRIPTIONS

Online Form. Welcome to the Integrated Research Application System. IRAS Project Filter

Syllabus for International Dental Assistants. Prepare and maintain the dental surgery, instruments, and equipment for clinical dental procedures

Hong Kong Association of Medical Physics. Guide to Candidates

Image Diagnostic Technology Ltd 53 Windermere Road, London W5 4TJ Tel: +44 (0)

15-17 October 2014, BfS Neuherberg. WHO International Consultation:

Instructions for Applicants. Successful completion of this examination is required as one of the conditions for licensure in the State of Vermont.

1 DECISION 1 (6) REFERENCE LEVELS FOR THE PATIENT S RADIATION EXPOSURE FOR PAEDIATRIC X-RAY EXAMINATIONS

LEGAL ASPECTS of MEDICAL MARIJUANA Florida Nurse Practitioner Network Annual Conference September 17, 2018

RADIATION MANAGEMENT PLAN EXPLANATORY NOTE

Transcription:

IRMER Ionising Radiation Medical Exposure Regulations Download for information at www.scottishdental.org IONISING RADIATION (MEDICAL EXPOSURE ) REGULATION 2000 (as Amended) (IR(ME)R AN EXPLANATION GUIDE TO DENTISTS DEC 2011 These regulations are concerned with the safety of patients They came into force on 13 MAY 2000 They replace the Ionising Radiation (Protection of Persons Undergoing Medical Examination or Treatment)Regulations 1988 (IRR 88) JUSTIFICATION OPTIMISATION LIMITATION JUSTIFICATION NO PRACTICE shall be adopted unless its introduction produces a net benefit Regulation 6 IRMER REGS

Sufficient net benefit Detriments Alternatives Write it down!!!!! Regulation 5 (2) The practitioner shall be responsible for the justification of a medical exposure Selection Criteria in Dental Radiology OPTIMISATION ALL EXPOSURES shall be kept as low as reasonably practicable ALARP taking economic and social factors into account RADIATION RISKS AGE IN YEARS MULTIPLICATION FACTOR PER RISK OF CANCER UNDER 10 x 3 10-20 x 2 20-30 x 1.5 30-50 x o.5 50-80 x 0.3 OVER 80 Negligable Lower the age-higher the risk Justification Dose limitation: - Technique - Quality Assurance - Selection Criteria

- Use of guideline exposure settings All doses must be kept as low as reasonably practicable ALARP Apply QA procedures to the optimisation of patient dose Regulation 7 (3) the operator shall select equipment and methods to ensure that for each medical exposure the dose of ionising radiation to the individual undergoing the exposure is as low as reasonably practicable. Written protocols in place for type of standard exposure for each x-ray set Adherence to diagnostic reference levels Practical aspects Tube operating parameters Rectangular collimation Film speed X-ray holders Regulation 4 (c) Diagnostic reference levels for radiodiagnostic examinations having regard to European DRLs A radiation dose for a typical examination for a standard sized patient Aid to optimisation National or European DRLs Should not be exceeded without good reason Do we know? MPE LIMITATION The dose equivalent to individuals shall not exceed the limits recommended by the ICRP INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

DEFINES NEW POSITIONS of RESPONSIBILITY: IRMER DUTY HOLDERS The Employer (Legal Person) The Referrer The Practitioner The Operator IRMER regulations 2,4 and 5 ESSENTIAL REQUIREMENTS IRMER 2000 DUTIES OF EMPLOYERS: WRITTEN PROCEDURES ENTITLEMENT AND IDENTIFICATION REFERRERS/PRACTITIONERS/OPERATORS ENTITLEMENT SHOULD BE IN WRITING To include scope of entitlement Records of training and competency WRITTEN PROCEDURES TO IDENTIFY PATIENTS Difference between referrer and operator? ask the patient what is your name? what is your date of birth? what is your address? IDENTIFICATION OF PREGNANT PATIENTS Why? When? How?

- AUTHORISATION AND JUSTIFICATION OF EXPOSURES Referral - Clinical indications to allow justification Justification - intellectual process Authorisation signature to prove justification DOCUMENTED BEFORE films are taken CARRYING OUT AND RECORDING CLINICAL EVALUATION Evaluation of dental Exposure Evaluation to be recorded for every examination - Dentists Report - Record in the patients notes If no evaluation is recorded - exposure was not justified - exposure was illegal Regulation 8 Clinical evaluation of the outcome of each procedure is recorded in accordance with the employer s procedures USE OF DIAGNOSTIC LEVELS (DRLS) DIAGNOSTIC REFERENCE LEVELS Typical dose for a standard patient Set locally National recommendations

- Intra oral film - 2.1 mgy (ESD) - Panoral film - 65 mgy (DWP) DOSES GREATER THAN INTENDED Notification when dose to patient is much greater than intended not due to equipment fault - report to Care Quality Commission (England) - Scottish Ministers Example wrong patient being x rayed COMPLIANCE WITH QA PROGRAMMES Assessment of patient dose Reducing probability and magnitude of accidental and unintended doses to patients PROVISION FOR CLINICAL AUDIT Written Protocols and guideline exposure settings for every type of standard projection for each item of equipment Procedures for overexposure (not machine malfunction) IRMER AND TRAINING For practitioner and operator Proof of training Training records kept by the employer It is recommended that these employers written procedures and the local rules are kept together as the RADIATION PROTECTION FILE

DUTIES OF THE REFERRER PRACTITIONER OPERATOR THE REFERRER A registered doctor or dentist or other health professional entitled to refer a patient to a practitioner for a medical exposure. The referrer is responsible for supplying the practitioner with sufficient information to justify an appropriate exposure Must have been a history and clinical examination previous to the referral Previous radiographs should accompany the patient if relevant Diagnostic information entered in writing THE PRACTITIONER A registered doctor or dentist or other health professional entitled to take responsibility for a medical exposure. The practitioner must be adequately trained to take decisions and the responsibility for the justification of every exposure

THE OPERATOR The person conducting any practical aspect of a medical exposure Practical aspects include: patient identification positioning film, patient or x-ray tubehead Setting of exposure options Pressing the exposure switch to initiate the exposure Processing films Clinical evaluation of exposures Exposing test objects as part of QA programme The operator must be adequately trained for their role in the exposure JUSTIFICATION OF INDIVIDUAL MEDICAL EXPOSURE Before and exposure can take place it must be justified (ie assessed to ensure that it will lead to a change in the patient s management and prognosis) by an IRMER practitioner and authorised as the means of demonstrating that it has been justified Every exposure should be justified on the grounds of------ The radiation risk associated with radiographic examination The efficacy, benefits and risks of alternative techniques having the same objectives involving no or less exposure to ionising radiation HISTORY AND CLINICAL EXAMINATION ARE THE ONLY ACCEPTABLE MEANS OF DETERMINING THAT THE MOST

APPROPRIATE OR NECESSARY RADIOGRAPHIC VIEWS ARE REQUESTED CLINICAL AUDIT Provision must be made for clinical audit EXPERT ADVICE Involvement of Medical Physics expert for advice on measurement and optimisation of patient dose usually the RPA can act as the MPE EQUIPMENT Keeping and maintenance of itemised inventory of equipment including: Name of manufacturer Model no Serial no Year of manufacture Year of installation EQUIPMENT INVENTORY Regulation 10 The employer shall draw up, keep up to date and preserve at each radiological installation an inventory of equipment at that installation, and when requested, shall furnish it to the RQIA. REGULATION AND QUALITY IMPROVEMENT AUTHORITY

REFERRAL FORM Patient details View requested Clinical reason for request Particular areas of interest to be included on the film Authorisation to prove Justification Relevant medical history Signature can be electronic SUBJECTIVE QUALITY RATING 1. No less than 70% Excellent no errors of exposure, positioning or processing 2. No greater than 20% Acceptable some errors of exposure, positioning or processing 3. No greater than 10% Un acceptable errors rendering film unacceptable Documented with steps to rectify Reported - Recorded Signed Exposure assessment: Local rules and exposure parameters Size of patient

Condition of dentition Reason for radiograph PA Path Caries Bone levels ADEQUATE TRAINING AND CONTINUING EDUCATION OPERATORS AND PRACTITIONERS must have received adequate training and must undertake continuing education and training after qualification Nature of training is in the GUIDANCE NOTES OPERATOR ADEQUATE TRAINING OPERATORS INVOLVED IN RADIOGRAPHING PATIENTS Dentists - practitioner training Dental nurses - possess Certificate in Dental Radiography from a course conforming to the syllabus prescribed by the College of Radiographers Dental hygienists/therapists - equivalent training to nurses or Dentists? OPERATORS INVOLVED IN PROCESSING/QA Dental nurses and other DCPs should possess the Certificate in Dental Nursing or have received adequate and documented training specific to the tasks that they undertake CONTINUED PROFESSIONAL DEVELOPMENT CPD mandatory under IR(ME)R for all practitioners and operators involved in radiographing patients Dental radiography and radiation protection recommended by the GDC in 2006 as one of 3 'core subjects' for dentists requiring 5 hours of verifiable CPD within the 5 yearly CPD cycle Operators should attend a continuing education course every 5 years

Dental radiography and radiation protection recommended by the GDC as a'core' CPD subject for registered DCPs every 5 years from August 2008 PRACTITIONER COURSES: Principles of radiation physics Risks of ionising radiation Radiation doses in dental radiography Factors affecting doses in dental radiography Principles of radiation protection Statutory requirements Selection criteria Quality assuranc OPERATOR COURSES: Principles of radiation physics Risks of ionising radiation doses in dental radiography Factors affecting dose in dental radiography Principles of radiation protection Statutory requirements Quality assurance Recommended publications: Selection Criteria for Dental Radiography

Published By: Faculty of General Dental Practitioners (UK) Royal College of Surgeons of England Guidance Notes for Dental Practitioners on the Safe Use of X-Ray Equipment Published by: National Radiological Protection Board Orthodontic Radiographs Guidelines Published by: British Orthodontics Society Guidelines on Radiology Standards for Primary Dental Care