Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Similar documents
Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Quality Assurance in Stereotactic. Radiotherapy. Swedish Cancer Institute Seattle, WA

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Credentialing for the Use of IGRT in Clinical Trials

EORTC Member Facility Questionnaire

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

SRS/SBRT Errors and Causes

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

SRS Uncertainty: Linac and CyberKnife Uncertainties

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

ph fax

AbstractID: 8073 Title: Quality Assurance, Planning and Clinical Results for Gamma Knife Radiosurgery S. Goetsch, Ph.D. Page 1 Seattle, WA May 2008

Clinical Implementation of SRS/SBRT

SBRT REQUIRES: STEREOTACTIC BODY RADIOTHERAPY STEREOTACTIC BODY RADIOTHERAPY (SBRT) (SBRT) What s s in a name? Stereotactic Body Radiotherapy

SUPPLEMENTAL MATERIAL

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Global Radiosurgery 2011 All Rights Reserved 1

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Unrivaled, End-to-End

Patient-specific quality assurance for intracranial cases in robotic radiosurgery system

Who Should Know Radiation Oncology Coding?

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Disclosures. Clinical Implementation of SRS/SBRT. Overview. Anil Sethi, PhD. Speaker: BrainLAB Standard Imaging Research collaboration: RaySearch

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Implementing SBRT Protocols: A NRG CIRO Perspective. Ying Xiao, Ph.D. What is NRG Oncology?

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Case Study. Institution Farrer Park Hospital

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

Pitfalls in SBRT Treatment Planning for a Moving Target

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Work partially supported by VisionRT

Overview of MLC-based Linac Radiosurgery

Patient-Specific QA & QA Process. Sasa Mutic, Ph.D. Washington University School of Medicine

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Image Guided Stereotactic Radiotherapy of the Lung

Radiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague

In-Room Radiographic Imaging for Localization

Guideline & Reports 医学物理学会教育委員会資料

Film-based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom

2011 All Rights Reserved

Leksell Gamma Knife Icon A New User s Perspective

Original Date: April 2016 Page 1 of 7 FOR CMS (MEDICARE) MEMBERS ONLY

8/3/2016. Outline. Site Specific IGRT Considerations for Clinical Imaging Protocols. Krishni Wijesooriya, PhD University of Virginia

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

Disclosures. Overview 8/3/2016. SRS: Cranial and Spine

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

In-Room Radiographic Imaging for Localization

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Innovative RT SBRT. The variables with REQ in superscript are required.

Limits of Precision and Accuracy of Radiation Delivery Systems

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Dosimetry of the Gamma Knife TM

On the use of 4DCT derived composite CT images in treatment planning of SBRT for lung tumors

CPT code semantics 8/18/2011. SBRT Planning Case Studies. Spectrum of applications of SBRT. itreat

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Leila E. A. Nichol Royal Surrey County Hospital

Activity report from JCOG physics group

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Commissioning and initial stereotactic ablative radiotherapy experience with Vero

such as lung cancer or breast cancer

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Stereotactic Radiosurgery

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

brain SPINE 2 SRS Matures into breast lung spine LUNG Dr. Robert Timmerman Discusses SBRT for Inoperable Lung Cancer BRAIN

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

The Journey of Cyberknife Commissioning

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Overview of Advanced Techniques in Radiation Therapy

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Eric E. Klein, Ph.D. Chair of TG-142

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

I. Equipments for external beam radiotherapy

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Dosisverifikation mit Delta 4 Discover während der Behandlung

Flattening Filter Free beam

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

SRS Plan Quality and Treatment Efficiency: VMAT vs Dynamic Conformal ARCs

Transcription:

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy Implementation of radiosurgery and SBRT requires a fundamentally sound approach Errors don t blur out and can t be corrected later Timothy D. Solberg, Ph.D. University of Texas Southwestern Medical Center Dallas, TX Assemble your team Plan Ahead Assemble the Documentation ACR / ASTRO Practice Guidelines Coordinate with all involved well in advance Determine your clinical goals SRS: Mets, benign tumors, pain, functional? Single fraction, fractionated? SBRT: Lung, liver, spine, others? What do they cover? Personnel Qualifications / Responsibilities Procedure Specifications Quality Control / Verification / Validation Follow-up Assemble the Documentation Task Group Reports AAPM Report #54 Stereotactic Radiosurgery AAPM Report #91 The Management of Motion in Radiation Oncology (TG 76) TG 68 Intracranial Stereotactic Positioning Systems TG 101 Stereotactic Body Radiotherapy TG 104 kv Localization in Therapy TG 117 Use of MRI in Treatment Planning and Stereotactic Procedures TG 132 Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning TG 135 QA for Robotic Radiosurgery TG 147 QA for Non-Radiographic Radiotherapy Localization and Positioning Systems TG 155 Small Fields and Non-Equilibrium Condition Photon Beam Dosimetry TG 176 Task Group on Dosimetric Effects of Immobilization Devices TG 178 Gamma Stereotactic Radiosurgery Dosimetry and QA TG 179 QA for Image-Guided Radiation Therapy Utilizing CT-Based Technologies Some words about Report No. 54 Only for cranial applications Published in 1995, so it predates: MR Localization Relocatable Frames Image Fusion Micro-MLC Robotic Linacs and Perfexion Units Others.. 1

RTOG Protocols Assemble the Documentation RTOG 0236 has something for everyone Anatomy Definition RTOG 9005 Single Dose Radiosurgical Treatment of Recurrent Previously Irradiated Primary Brain Tumors and Brain Metastases RTOG 9305 Randomized Prospective Comparison Of Stereotactic Radiosurgery (SRS) Followed By Conventional Radiotherapy (RT) With BCNU To RT With BCNU Alone For Selected Patients With Supratentorial Glioblastoma Multiforme (GBM) RTOG 9508 A Phase III Trial Comparing Whole Brain Irradiation Alone Versus Whole Brain Irradiation Plus Stereotactic Radiosurgery for Patients with Two or Three Unresected Brain Metastases RTOG 0236 A phase II trial of SBRT in the treatment of patients with medically inoperable stage I/II non-small cell lung cancer RTOG 0618 A phase II trial of SBRT in the treatment of patients with operable stage I/II non-small cell lung cancer RTOG 0813 Seamless phase I/II study of SBRT for early stage, centrally located, non-small cell lung cancer in medically operable patients OAR Constraints Guidance for physicists Other Documents ASTRO/AANS Consensus Statement on stereotactic radiosurgery quality improvement, 1993 RTOG Radiosurgery QA Guidelines, 1993 European Quality Assurance Program on Stereotactic Radiosurgery, 1995 DIN 6875-1 (Germany) Quality Assurance in Stereotactic Radiosurgery/Radiotherapy, 2004 and read the literature! Determine what kinds of delivery techniques will be used Determine how you will: IMRT? Dynamic Arcs? VMAT? Robotic Delivery? Simulate Manage Motion 4DCT / Compress / Gate / Track. Immobilize Localize MV / kv / CBCT / Calypso. Verify 2

Assemble the proper resources Example: Novalis Tx Personnel Time Equipment Dosimetry Equipment Specialized Phantoms Immobilization Devices Clarify procedures and responsibilities, and design QA program As the physicist, you will be responsible for all of the technical details! Real-time Stereoscopic Infrared Imaging Robotic Couch Dual Energy Linac w/ HD-120 Electronic MLC: Portal 2.5 and SRS mode and multiple 5 mm Imaging leaves energy electrons On-board Room-mounted Imaging Stereoscopic and CBCT Imaging Example: Novalis Tx New Planning System with Many Delivery Techniques Stereotactic Target SRS SRT Positioner Frame Mask Localizer Circular Winston-Lutz Collimator Couch Collimators Mount Tool Conformal Gating AVMs SBRT Beams Trigeminal Circular IMRT Collimators Neuralgia New Planning System with Many Delivery Techniques Prepare for the task at hand Gating Dynamic Arcs Commissioning photons on a Novalis Tx is akin to commissioning 7 beams: Cones-Direct Measurement XLow Standard-Pencil Beam XLow SRS-Pencil Beam XHigh Standard-Pencil Beam XLow Standard-Monte Carlo XLow SRS-Monte Carlo XHigh Standard-Monte Carlo 3

Get the Documentation Get the right equipment Small fields require small detectors Circular collimators 4 15 mm in diameter MLC fields 5x5 mm 2 400x400 mm 2 Be careful with diodes and radiographic film 1) Both diodes and film are energy dependent, and the energy spectrum varies considerably for small fields relative to large fields. So: - Use Gafchromic film, not radiographic film - Use an intermediate reference field appropriate for both diodes and ion chambers Monte Carlo requires scanned data in air Need a brass buildup cap for your small chamber 2) Diode response drifts over time - Re-measure reference between each change in field size Reference diode output to an intermediate field size The Million Dollar Question Are your data correct? 1 Circular Collimators - XLow Output Factor Reading (FS) diode = X Reading (Ref ) diode Reading (Ref ) IC Reading (Ref) IC Relative Output Factor 0.9 0.8 0.7 0.6 NO! Reading (5 mm) diode 0.1 Reading (100 mm) diode YES! Reading (5 mm) diode X Reading (20 mm) diode Reading (20 mm) IC Reading (100 mm) IC 0 0 2 4 6 8 10 12 14 16 Field Diameter (mm) 4

Compare with Existing Data Compare with Existing Data HD-120 Fields XLow SRS Mode HD-120 Fields XLow Standard Mode Institution 1 Institution 2 Off Axis Profiles Cones Diagonal (Radial) Profiles Standard Mode This shouldn t be difficult, but.. Know how your data is processed and what the planning system does with it Output Factor ~45% Institution 5

And people continue to have problems A different institution in the U.S Institution in the U.S 1.2 Cone size (mm) Original Output Factor Re-measured Output Factor 1 0.8 Institution A Institution B 4.0 7.5 10.0 12.5 15.0 17.5 20.0 25.0 30.0 0.312 0.610 0.741 0.823 0.862 0.888 0.903 0.920 0.928 0.699 0.797 0.835 0.871 0.890 0.904 0.913 0.930 0.940 0.6 0.4 0.2 0 0 50 100 150 200 250 300 Depth (mm) And still another institution in the U.S Commissioning your system: Does calculation agree with measurement? 110 100 Percent Depth Dose 90 80 70 60 50 40 6.0 % 10.3 % Institution A Institution B 30 20 10 0 0 50 100 150 200 250 300 350 400 450 Depth (mm) Start simple, and increase complexity End-to-end testing Dosimetric uncertainty 1 isocenter 4 field box Calculation arc-step Calculation = 10 o arc-step = 2 o Dynamic Conformal Arcs 2 isocenters off axis Relative Dosimetry 2 isocenters on axis IMRT 6

End-to-end testing Dosimetric uncertainty End-to-end dosimetric evaluation Absolute Dosimetry Lucy Phantom Lucy Phantom End-to-end dosimetric evaluation End-to-end dosimetric evaluation End-to-end dosimetric evaluation Isocentric Accuracy: The Winston-Lutz Test 7

Mechanical Uncertainties Perform for Cones and MLC Is the projection of the ball centered within the field? Good results 0.5 mm Is the projection of the ball centered within the field? End-to-end localization evaluation Phantom Specifications iplan Stereotactic Coordinates AP LAT VERT Structure AP LAT VERT Cylinder 0.0 0.0 30.0 1.0 0.4 30.8 Cube 20.0-17.0 40.0 20.8-17.1 42.4 Cone -35.0-20.0 40.0-34.6-19.7 40.8 Sphere 25.0 20.0 32.7 25.5 20.2 33.5 End-to-End Localization Accuracy 8

Verification of MLC shapes and isocenter Fusion Verification MR Fusion Hidden Target Test scan, plan, localize assess RPC Phantom Lucy Phantom Use ALL the RPC phantoms Immobilization / Motion Management Use abdominal compression (typically) to control tumor motion to less than 0.5-1.0 cm. We visualize the tumor OR use the dome of diaphragm Perform 4-D CT (using bellows for phase) under compression 9

How will you use 4D CT? Maximum Intensity Projection PTV ITV AVG Uncompressed Compressed How do you know its all correct? Localization Frame Based or Image Based? Image Guided Localization Anatomy or Markers? Frame-assisted image guidance never frame alone Depends on the image guidance methodology and the anatomy / application Have lots of redundancy Localization Stereo X-rays 10

Also works well in Spine How do we know the system is targeting properly? End-to-end evaluation that mimics a patient procedure Identify target & plan X-ray Irradiate DRR Set up in treatment room Evaluate Results of Phantom Data Localization - cone beam CT (mm) Lat. Long. Vert. 3D vector Average -0.06-0.01 0.05 1.11 Standard Deviation 0.56 0.32 0.82 0.42 Sample size = 50 trials (justified to 95% confidence level, +/- 0.12mm) End-to-end evaluation: Extracranial CBCT for Localization of Lung SBRT Patients 3D error 1.2 ± 0.4 mm 11

CBCT for Localization of Prostate SBRT Patients CBCT for Localization of Prostate SBRT Patients Localization using implanted fiducials Localization using implanted fiducials Courtesy Sam Hancock, PhD, Southeast Missouri Hospital Courtesy Sam Hancock, PhD, Southeast Missouri Hospital Know your planning system, and what s makes a plan good Know your dose The Initial SBRT Experience 20 tumors (all primary) in 11 patients 1-3 fractions of 5-15 Gy per fraction (14-45 Gy total dose) 70% response and no recurrences at 12 months All patients developed fever and nausea 2 patients developed ascites and subsequently died: 3 x 15 Gy for 57 cc tumor (HCC, hepatitis, cirrhosis) 3 x 10 Gy for 293 cc tumor (HCC) One patient died 2 days following a single dose of 30 Gy to a large tumor Blomgren et al, Acta Oncol. 34:861-70, 1995 12

SRS has existed as a clinical tool for over 50 years, and SBRT for over a decade. While both applications have reached a level of maturity, the associated technologies continue to evolve Both applications present physicists with many unique challenges The significance of potential treatment errors imposes a high level of diligence, a thorough and systematic approach, and considerable time and resources, for implementing these technologies If your institution isn t willing to fully commit, then don t implement an SRS or SBRT program 13