Journal of Foot and Ankle Research

Similar documents
Relationship between the Apex of Flexible Nail and the Level of Fracture: A Biomechanical Study Ahmed N* 1, Gakhar H 2, Cheung G 3, Sharma A 4

Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates

EXTERNAL FIXATION SYSTEM

Biomechanical Comparison of Four Different Lateral Plate Constructs for Distal Fibula Fractures

COMPARING KIRSCHNER WIRE FIXATION TO A NEW DEVICE USED FOR PROXIMAL INTERPHALANGEAL FUSION

Mehmet Erdil 1,Hasan Huseyin Ceylan 2, Deniz Kara 3,Gokhan Polat 4, Ergun Bozdag 5, Emin Sunbuloglu 5

Knee spanning solutions

Stability at the half pin frame interface on external fixation constructs

Biomechanics of Fractures and Fixation

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

THE MEMORY STAPLE SURGICAL TECHNIQUE

Zimmer Small Fragment Universal Locking System. Surgical Technique

Distal Radius Plate 2.4/2.7 dorsal and volar

Foot & Ankle. EasyClip. Osteosynthesis Compression Staples. Foot & Ankle

Nailing Stability during Tibia Fracture Early Healing Process: A Biomechanical Study

Biomechanical and Clinical Evaluation of a New Operative Technique

Surgical technique. Angular Stable X-Plate and 2-Hole Plate. For osteotomies, arthrodeses and fractures of the foot.

Experimental Prediction of Contact Area in Hip Replacement and Hemi- Arthroplasty

Stiffness of callus tissue during distraction osteogenesis

3.5 mm Locking Attachment Plate

CERTIFICATE OF ACCREDITATION

Designing a Novel Fixation Device for Pediatric Orthopaedic Tibia Fractures

This publication is not intended for distribution in the USA.

HELIOS h i p s y s t e m

CERTIFICATE OF ACCREDITATION

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

Clover Staple. Surgical Technique

Hoffmann II Compact External Fixation System

MetaFix Ludloff Plate

Memory Staple. Surgical Technique

Intramedullary Nailing: History & Rationale

External Fixator Brochure

AcUMEDr. Olecranon Threaded Compression Rod

Three Dimensional Titanium Mini Plates in Management of Mandibular Fractures

Competitive Overview. 1.K-Wires. Arrowhead Med Technologies

Small Fragment Plating System

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

PROXIMAL TIBIAL PLATE

FLEXIBLE NON-METAL TRAUMA SOLUTIONS.

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Specializing in Mechanical Testing for Medical Devices. Office:

The Metacarpal Locked Intramedullary Nail: Comparative Biomechanical Evaluation of New Implant Design for Metacarpal Fractures

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

2.0. The Unrivaled Solution for MidFoot Fusion. Reinforced Bone Bridge. Zero Profile. Because Uniform Compression is Better Compression

Ratcheting Compression Plating System. Value Analysis Committee Resource Guide

Plate Fixation Options

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

Back out of Locking Pin with Hinge Fracture after High Tibial Osteotomy

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Monolateral External Fixation System for Trauma and Orthopaedics

Compression Screw 3.2 Bioabsorbable. Product information

Pre-Operative Planning. Positioning of the Patient

The Vilex FUZETM. Dual Thread Screw & Intramedullary Nail in One Implant. The Ultimate TTC Arthrodesis Internal Fixator

Continuing the Tradition. VerSys Heritage Hip System

Small Fragment Plating System. Securing optimal fixation through locked and compression plating technology

Flower Opening Wedge Plate

Comparitive Study between Proximal Femoral Nailing and Dynamic Hip Screw in Intertrochanteric Fracture of Femur *

Locked plating constructs are creating a challenge for surgeons.

Variable Angle LCP Locking Technology

The Flower Forefoot PROCEDURE GUIDE.

AcUMEDr. AcUTRAKr. Headless Compression Screw

ORTHOLOC CROSSCHECK TECHNOLOGY OVERVIEW FOR HOSPITAL VALUE ANALYSIS COMMITTEE

Locked Plate Fixation of Osteoporotic Humeral Shaft Fractures: Are Two Locking Screws Per Segment Enough?

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

Introduction Basics MIS Screw 2 System Characteristics 2 Indication 2

Treatment of open tibial shaft fractures using intra medullary interlocking

Does the self-centering mechanism of bipolar hip endoprosthesis really work in vivo?

BIOMECHANICAL EVALUATION OF INCOMPLETE RINGS AND HYBRID FIXATOR CONSTRUCTS

This is a repository copy of Mechanics of musculoskeletal repair devices.

Micro-CT imaging of surgical screw tightening in human trabecular bone

4Fusion. Shape Memory Implant. Operative Technique

The American Academy of Foot & Ankle Osteosynthesis. presents

2.7 mm/3.5 mm Variable Angle LCP. Ankle Trauma System

SMV Scientific Bone Plate and Screw System Surgical Technique

Comparative Study of Fixation Devices for Intertrochanteric Fractures

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

UNITE Foot Plating System

External Skeletal Fixation (ESF)

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

Stability of Talar Neck Fracture Fixation: A Biomechanical Comparison of 4.0 Cannulated Headed Screws and Conical Headless Screws

Asnis III Cannulated Screw System. Operative technique

The Flower Straight Fibula Plate

Technique Guide. DCP and LC-DCP Systems. Dynamic Compression Plates (DCP) and Dynamic Compression Plates with Limited Bone Contact (LC-DCP).

Mini External Fixator.

Introduction to the Taylor Spatial Frame Hardware. Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off.

Results of tibia nailing with Angular Stable Locking Screws (ASLS); A retrospective study of 107 patients with distal tibia fracture.

The Flower Medial Column Fusion Plate

Efficacy of a Kirschner-Wire Guide in Distal Linear Metatarsal Osteotomy for Correction of Hallux Valgus

Foot & Ankle. Smart Toe II. Intramedullary Implant. Operative Technique. Foot & Ankle

FLT105 12/02.

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

Ankle Fractures in the Elderly: How to Deal with Poor Bone Quality

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

Alignment Rod. For intraoperatively confirming correction of the mechanical leg axis.

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

Large External Fixator Delta Frame Ankle Bridge. Using pin clamps with outrigger posts.

Transcription:

Journal of Foot and Ankle Research BioMed Central Research Mechanical characteristics of three staples commonly used in foot surgery Ulfin Rethnam* 1, Jan Kuiper 2 and Nilesh Makwana 3 Open Access Address: 1 Department of Orthopaedics, Glan Clwyd Hospital, Bodelwyddan, UK, 2 Hip Research Unit, Robert Jones & Agnes Hunt Orthopaedic Hospital, Oswestry, UK and 3 Department of Orthopaedics, Robert Jones & Agnes Hunt Orthopaedic Hospital, Oswestry, UK Email: Ulfin Rethnam* - ulfinr@yahoo.com; Jan Kuiper - Jan.Kuiper@rjah.nhs.uk; Nilesh Makwana - nilesh@bhanu.freeserve.co.uk * Corresponding author Published: 25 February 2009 Journal of Foot and Ankle Research 2009, 2:5 doi:10.1186/1757-1146-2-5 This article is available from: Received: 22 August 2008 Accepted: 25 February 2009 2009 Rethnam et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Abstract Background: Bone staples are an accepted method of fixation in foot surgery. They reduce operating time and trauma in surgical procedures. A variety of memory staples are available but their properties compared to standard staples are not known. We carried out a study comparing two popular types of memory staples and a standard stainless steel staple. Methods: Standardized bone models of metatarsals made from Tufnol tubes were osteotomized and stabilised using one of three types of bone staples, two types of memory staple (Memory staple and heat-activated Memoclip) or a standard stainless steel staple (Richards). Constructs were loaded in bending and torsion on a material testing machine. The moment and torque to achieve 10 degree of bending or torsion and permanent angulation of the osteotomized bones were assessed. Results: The Richards staple was found to provide a four times larger resistance to bending and torsion than the two memory staples. However, it was permanently deformed after bending. The Memory and Memoclip staples were equal in their stiffness. In addition, angulation of bones fixed with the Memoclip was elastic, preventing any permanent deformation. Conclusion: The Richards staple was stiffer, although the permanent deformation of this staple is a disadvantage. Memoclip staples exhibit lower but adequate stiffnesss when compared to the standard Richards staple and are not permanently deformed after bending. The Memoclip staples were easier to handle. The results will enable surgeons to determine the optimal staple for foot and ankle procedures. Background Bone staples are widely used in foot and ankle surgery. They are considered to be an effective internal fixation method [1]. The cited advantages of bone staples include easier fixation onto bones, reduced surgical time and trauma. This in turn leads to improved healing and reduced post-operative pain [2]. Various types of bone staples are available, differing in their shape and physical properties. Recently, bone staples have been introduced based on shape-memory materials. For all staples, manufacturers cite advantages in terms of ease of use and provide compression strength based on physical properties of the metals used to produce the staples. However, little is known about the actual fixation Page 1 of 5

2009, :5 capabilities of staples used in foot and ankle surgery and how these compare between staples. It is unknown how the fixation capabilities of staples based on memory material compare to those of conventional metals. The aim of this study was to compare two types of staples based on memory metal and one conventional staple, all three commonly used in foot and ankle surgery. Specifically, we addressed the question regarding the bending stiffness, torsional stiffness, and permanent deformation of these staples. The null hypothesis was that there was no difference in stiffness between the staples. Methods This study was conducted in the Laboratory for Biomechanics at The Robert Jones and Agnes Hunt Orthopaedic Hospital in Oswestry after approval from the review board. Materials Three types of staples were used in this study, two of which were made of nickel-titanium (nitinol) memory material. All the staples had a bridge dimension of 14 mm and leg dimensions of 12 mm. The first of these, Memoclip (Heritage, United Kingdom), is heat activated (Figure 1). When the staple is exposed to a temperature above 50 degrees Centigrade, these staples deform their limbs and generate compression. The second of these, the Memory staple (Depuy, United Kingdom), is normally stored at 0 4 degrees Centigrade. When the staple is brought to body temperature (37 degrees Centigrade), the limbs deform and cause compression of bone. The third staple (Richards staple, Smith & Nephew, United Kingdom) is made of stainless steel (Figure 1). Compression is achieved by the mechanical properties of the staple. No further compression is achieved once the staple is inserted into bone. Specimen preparation Standardised metatarsal bone models made of Tufnol tubes (10 mm diameter) were used (Figure 2). We used Tufnol tubes for our study as they exhibit similar properties to bone and are commonly used in biomechanical studies [3,4]. The Tufnol tubes were 15 cm in length and they were osteotomised in the centre with a saw. The osteotomised tubes were stabilised using a single staple applied perpendicular to the osteotomy. Fixation of the near and far cortices (bicortical) was done for each specimen. 5 specimens were constructed for each staple type (n = 5 for each staple type). Mechanical testing The prepared specimens were mounted on a materials testing machine (ESH Ltd, Brierly Hills, United Kingdom) (Figure 3). Each construct was tested in four point bending and torsional stress (Figure 4). Load displacement curve and stiffness of fixation of each staple were measured. A constant temperature of 37 degrees Centigrade was maintained throughout the experiment using a thermostat controlled fan heater. Outcome measures and statistical analysis The primary outcome measure was the moment to achieve 10 degree of bending or torsion at the osteotomy site of the specimen. A 10 degree deformation of the construct was considered as mechanical failure of the staple as in a clinical situation 10 degree angulation at a fracture or osteotomy after fixation would be considered as an implant failure (Figure 5). One-way Analysis of Variance (ANOVA) was used for statistical analysis of the results and the Tukey test was used for pairwise comparison between the staples. p < 0.05 was considered to be statistically significant. Memory Figure 1(left) & mechanical (right) staples Memory (left) & mechanical (right) staples. Tufnol tubes used Figure 2 Tufnol tubes used. Page 2 of 5

2009, :5 Materials Figure 3testing machine Materials testing machine. Deformation Figure 5 of construct on four point bending stress Deformation of construct on four point bending stress. Results Bending stress In four point bending, there was a non-linear relation between the bending angle and the bending moment. The average moment to achieve 10 degree of bend at the osteotomy site of the specimens was as follows: Richards staple: 1.9 ± 0.21 Nm, Memoclip staple: 0.51 ± 0.1 Nm and Memory staple: 0.44 ± 0.03 Nm. The Richards staple was four times stiffer than the Memory and Memoclip staples. This difference was statistically significant (p < 0.01, ANOVA followed by Tukey pairwise test) (Figure 6, 7). There was no significant difference between the Memoclip and Memory staple (p = 0.26, ANOVA followed by Tukey pairwise test). On removal of the load, constructs fixed with the Memoclip staple returned to their original shape while the other two staples were permanently deformed (Figure 6). Torsional stress In torsion, there was a linear relation between the torsion angle and applied torque. The average moment to achieve 10 degree torsion of the construct was as follows: Richards staple: 0.12 ± 0.03 Nm/degree, Memoclip staple: 0.04 ± 0.01 Nm/degree and Memory staple: 0.03 ± 0.01 Nm/ degree. The Richards staple was four times stiffer than the Memory and Memoclip staples. This difference was statistically significant (p < 0.01, ANOVA followed by Tukey pairwise test) (Figure 8). There was no significant difference in torsional stiffness between the Memoclip and the Memory staple (p = 0.998, ANOVA followed by Tukey pairwise Specimen Figure 4 undergoing four point bending stress Specimen undergoing four point bending stress. Load Figure displacement 6 curves for different staples in bending Load displacement curves for different staples in bending. Page 3 of 5

2009, :5 Bending Figure 7stiffness for different staples Bending stiffness for different staples. test). Upon removal of the load, all constructs returned to their original shape suggesting that there was no permanent deformation of the staples. Discussion Bone staples are used commonly in foot and ankle surgery. No data exists in the literature on the comparative analysis of biomechanical properties of bone staples. The fixation stiffness in bone staples is one of the most important factors determining the success of osteosynthesis along with compression achieved at the osteotomy site. There are studies evaluating the mechanical properties using different staple configuration and leg lengths of staples [5]. There are no studies that compare mechanical properties of staples with different physical properties. The staples selected for the study were made of different materials and had different physical properties. Two staples (Memoclip and Depuy Memory staple) achieved compression following deformation of the limbs when exposed to a particular temperature. The other staple (Richards) achieved compression by mechanically holding the bone ends across the osteotomy site. With bicortical fixation, the constructs fixed with the Richards staple was the stiffest in both bending and torsion stress. There was a permanent deformation of the Richard staple on Torsion Figure 8stiffness for different staples Torsion stiffness for different staples. bending and this may be a disadvantage of this staple as deformation of this manner in a clinical scenario would cause distraction at the osteotomy site. Both temperature activated memory staples (Memoclip and Memory staple) had similar fixation stiffness in bending & torsion. The Memoclip staple resisted permanent deformation while the Memory staple revealed some permanent deformation on bending. The advantages of these staples are that they cause compression at the osteotomy site after insertion. The mechanically activated Richards staple will also apply compression after insertion; it will not however have a propensity to deform further as will the shape-memory staples. Comparing the two memory staples, the Memoclip staples were easy to use as deformation of the limbs occurred only when exposed to temperatures >50 degree Centigrade. The Memory staple showed deformation of the limbs when exposed to body temperature therefore making insertion more difficult. The strength of our study was that it was conducted in a uniform environment maintaining constant temperature and a substitute (Tufnol tubes) similar to bone was used. The results of our study show that permanent deformation of the Richards staple occurs with increasing bending and torsional stress. However the Richards staple was on an average four fold stiffer than the temperature dependent staples. There was no significant difference between the Memoclip and Memory staples with regards to stiffness although the Memory staple did undergo permanent deformation in bending. This study will allow surgeons to make a more informed choice when using staples in foot and ankle surgery. Further clinical trials would be needed to compare these staples with regards to bone healing and fatigue failure. Conclusion Biomechanical testing of three different staples used in foot and ankle surgery revealed the Richards staple to have the highest fixation stiffness in both bending and torsion, although there was permanent deformation. The Memoclip staples provided adequate stiffness, resisted permanent deformation and were easier to handle which could be its advantages when compared to the Richards and Memory staple. Competing interests The authors declare that they have no competing interests. Authors' contributions UR the main author for the manuscript and was involved in specimen preparation, conducting the study, data acquisition and preparation of the manuscript. JK was involved in setting up of equipment, data analysis, inter- Page 4 of 5

2009, :5 pretation of data and preparation of the manuscript. NM the senior author was involved in conception and design of the study. All authors have read and approved the final manuscript. About the Authors UR - Orthopaedic registrar. JK - Research scientist. NM - Consultant Trauma & Orthopaedics References 1. Mow EM, Darby HD: Powered metaphyseal stapler: an effective and simplified internal fixation system used in multiple types of podiatric surgery. J Foot Surg 1991, 30(6):558-63. 2. Weltmer JB Jr, Cracchiolo A 3rd: The use of the powered metaphyseal stapler for reconstructive procedures in the adult foot. Foot Ankle 1990, 11(1):12-5. 3. Humphreys PK, Orr JF, Bahrani AS: An investigation into the effect of cyclic loading and frequency on the temperature of PMMA bone cement in hip prostheses. Proc Inst Mech Eng [H] 1989, 203(3):167-70. 4. Moorcroft CI, Thomas PB, Verborg S, Ogrodnik PJ: Cortex distraction forces caused by the insertion of external fixator pins. J Orthop Trauma 2001, 15(7):507-12. 5. Freeland AE, Zardiackas LD, Terral GT, Blickentaff KR: Mechanical properties of 3 M staples in bone block models. Orthopedics 1992, 15(6):727-31. Publish with BioMed Central and every scientist can read your work free of charge "BioMed Central will be the most significant development for disseminating the results of biomedical research in our lifetime." Sir Paul Nurse, Cancer Research UK Your research papers will be: available free of charge to the entire biomedical community peer reviewed and published immediately upon acceptance cited in PubMed and archived on PubMed Central yours you keep the copyright BioMedcentral Submit your manuscript here: http://www.biomedcentral.com/info/publishing_adv.asp Page 5 of 5