Ethambutol (EMB), the first-line drug used to treat mycobacterium

Similar documents
Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Ganglion cell complex scan in the early prediction of glaucoma

Clinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic Syndrome

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Jong Chul Han, Da Ye Choi, and Changwon Kee. 1. Introduction

Reports. Macular Thickness as a Potential Biomarker of Mild Alzheimer s Disease

Advances in OCT Murray Fingeret, OD

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Ethambutol toxic optic neuropathy

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

Changes in Peripapillary Retinal Nerve Fiber Layer Thickness after Pattern Scanning Laser Photocoagulation in Patients with Diabetic Retinopathy

Macular Thickness and Amblyopia

Non-arteritic anterior ischemic optic neuropathy (NAION) with segmental optic disc edema. Jonathan A. Micieli, MD Valérie Biousse, MD

Comparison of the Thickness and Volume of the Macula and Fovea in Patients with Anisometropic Amblyopia Prior to and after Occlusion Therapy

Longitudinal Changes of Retinal Thicknesses in Branch Retinal Artery Occlusion: Spectral-Domain Optical Coherence Tomography Study METHODS.

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

New Normative Database of Inner Macular Layer Thickness Measured by Spectralis OCT Used as Reference Standard for Glaucoma Detection

Diabetic macular edema (DME) is the most common cause. Effect of Diabetic Macular Edema on Peripapillary Retinal Nerve Fiber Layer Thickness Profiles

Sequential non-arteritic anterior ischemic optic neuropathy (NAION) Jonathan A. Micieli, MD Valérie Biousse, MD

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

OCT in the Diagnosis and Follow-up of Glaucoma

Pearls, Pitfalls and Advances in Neuro-Ophthalmology

Characterization of retinal nerve fiber layer thickness changes associated with Leber's hereditary optic neuropathy by optical coherence tomography

Macular thickness changes in a patient with Leber s hereditary optic neuropathy

Figure 1. Illustration of the progression of visual acuity in RESCUE

RETINAL NERVE FIBER LAYER

Eye Movements, Strabismus, Amblyopia and Neuro-Ophthalmology

53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Research Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

Bilateral Microphthalmos Associated with Papillomacular Fold, Severe Hyperopia and Steep Cornea

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Clinical Characteristics of Optic Neuritis in Koreans Greater than 50 Years of Age

Influence of cataract on image quality and macular thickness measured using spectral domain optical coherence tomography: a prospective cohort study

Assessment of Retinal Nerve Fiber Layer Changes by Cirrus High-definition Optical Coherence Tomography in Myopia

CHAPTER 13 CLINICAL CASES INTRODUCTION

CLINICAL SCIENCES. optic neuropathy characterized

Intrapapillary hemorrhage with concurrent peripapillary and vitreous hemorrhage in two healthy young patients

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

University Hospital Basel. Optical Coherence Tomography Emerging Role in the Assessment of MS PD Dr. Konstantin Gugleta

Characterization of macular thickness changes in Leber s hereditary optic neuropathy by optical coherence tomography

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

S uperior segmental optic hypoplasia (SSOH), also termed

International Journal Of Basic And Applied Physiology

Glaucoma Evaluation. OCT Pearls for Glaucoma. OCT: Retinal Nerve Fiber Layer. Financial Disclosures. OCT: Macula. Case Example

QUANTIFICATION OF PROGRESSION OF RETINAL NERVE FIBER LAYER ATROPHY IN FUNDUS PHOTOGRAPH

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology

Comparison of the Pattern of Retinal Ganglion Cell Damage Between Patients With Compressive and Glaucomatous Optic Neuropathies

THE STRUCTURE-FUNCTION JUNCTION

Cirrus TM HD-OCT. Details defi ne your decisions

Clinical Ophthalmology

Ji Soo Shin, Young Hoon Lee. Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea

Cirrus TM HD-OCT. Details define your decisions

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

Evolving glaucoma management True diagnostic integration for the preservation of vision

1. Background. Correspondence should be addressed to Atsushi Miki;

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Comparison of macular GCIPL and peripapillary RNFL deviation maps for detection of glaucomatous eye with localized RNFL defect

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

OtticaFisiopatologica

Structural examina.on: Imaging

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 2: Optic Nerve Head and Retinal

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Thickness Changes in the Fovea and Peripapillary Retinal Nerve Fiber Layer Depend on the Degree of Myopia

What You Should Know About Acute Macular Neuroretinopathy

SOUTH-EAST EUROPEAN JOURNAL of OPHTHALMOLOGY 2015; 1 (1) 34 40

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

The Measure of Confidence

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Case report: bilateral optic nerve head drusen and glaucoma

Rates of Abnormal Retinal Nerve Fiber Layer and Ganglion Cell Layer OCT Scans in Healthy Myopic Eyes: Cirrus Versus RTVue

OCT Assessment of the Vitreoretinal Relationship in CSME

Retinitis pigmentosa (RP) primarily affects the photoreceptor/pigment

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

Ganglion Cell-Inner Plexiform Layer Assesment with Cirrus Hd 5000 in Early Glaucoma

Measurement of Subfoveal Choroidal Thickness Using Spectral Domain Optical Coherence Tomography

Optical coherence tomography (OCT) is a noninvasive,

OPTOMETRY RESEARCH PAPER

Analysis of Peripapillary Atrophy Using Spectral Domain Optical Coherence Tomography

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

Glaucoma: Diagnostic Modalities

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

Reproducibility of Bruch Membrane Opening-Minimum Rim Width Measurements With Spectral Domain Optical Coherence Tomography

Glaucoma THE STRUCTURE-FUNCTION JUNCTION. Measuring Structure and Function. Structure-Function Relationship. Structure-Function Relationship

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

Comparison of retinal thickness measurements of normal eyes between topcon algorithm and a graph based algorithm

Clinical and OCT features of different types and stages of diabetic optic neuropathy

Optical Coherence Tomography (OCT) in Uveitis Piergiorgio Neri, BMedSc, MD, PhD Head Ocular Immunology Unit

EFFECT OF OPTIC DISK FOVEA DISTANCE ON MEASUREMENTS OF INDIVIDUAL MACULAR INTRARETINAL LAYERS IN NORMAL SUBJECTS

Transcription:

Eye Movements, Strabismus, Amblyopia and Neuro-Ophthalmology Ganglion Cell Layer and Inner Plexiform Layer as Predictors of Vision Recovery in Ethambutol-Induced Optic Neuropathy: A Longitudinal OCT Analysis Ju-Yeun Lee, Jae Hwan Choi, Kyung-Ah Park, and Sei Yeul Oh Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea Correspondence: Sei Yeul Oh, Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Korea; syoh@skku.edu. Submitted: September 15, 2017 Accepted: December 22, 2018 Citation: Lee J-Y, Choi JH, Park K-A, Oh SY. Ganglion cell layer and inner plexiform layer as predictors of vision recovery in ethambutol-induced optic neuropathy: a longitudinal OCT analysis. Invest Ophthalmol Vis Sci. 2018;59:2104 2109. https://doi.org/ 10.1167/iovs.17-22988 PURPOSE. To describe changes in the retina during ethambutol-induced optic neuropathy (EON) progression, and determine the retinal layer thickness as a predictive factor for vision recovery after stoppage of ethambutol (EMB) in EON. METHODS. A total of 42 eyes in 21 patients with EON underwent Spectralis optical coherence tomography after the onset of symptoms. Peripapillary and macular retinal nerve fiber layer as well as ganglion cell layer plus inner plexus layer (GCIPL) thickness was measured using Early Treatment Diabetic Retinopathy Study (ETDRS) circles. Data on best-corrected visual acuity at first visit and 1, 3, 6, and 12 months after stoppage of drug were collected. The longitudinal change of each retinal layer was described, and the association between retinal thickness at the first visit and the degree of vision recovery at each visit was analyzed. RESULTS. In inner temporal GCIPL, a 10-lm-thickness loss in the initial OCT was associated with a 0.5 decrease in the amount of logmar visual acuity recovery at 12 months (P < 0.001, 95% confidence interval [CI]: 0.2 0.7), and a 10-lm-thickness reduction between follow-up visits was associated with a 0.5 decrease in the amount of logmar visual acuity recovery (P < 0.001, 95% CI: 0.3 0.7). CONCLUSIONS. We described a structure function relationship between the retinal changes that occur in early EON and vision recovery. Temporal GCIPL could be used to predict vision recovery at 12 months after stoppage of EMB. Careful evaluation for GCIPL damage is required for visual prognosis in early EON. Keywords: ethambutol, optic neuropathy, visual acuity, recovery, ganglion cell layer Ethambutol (EMB), the first-line drug used to treat mycobacterium tuberculosis, is a common cause of toxic optic neuropathy. EMB-induced optic neuropathy (EON) has been reported in 1% to 5% of all patients, accounting for 100,000 new cases per year. 1 3 EON is characterized by dyschromatopsia and gradual visual loss of bilateral eyes. Since a delayed diagnosis of EON carries the risk of irreversible visual loss, early detection of EON and early stoppage of EMB are required. 4 Unfortunately, there are no obvious predisposing or risk factors to contribute to the poor visual gain after stoppage of EMB. 5 7 Despite the importance of early detection, early-stage EON (within 6 months of the onset of visual deterioration) does not present remarkable findings in a fundus examination. 8 Many trials have investigated structural changes to particular retinal layers to allow early detection of EON. 9 13 Evidence has emerged that the structural changes occur around the time of onset of symptoms. Han and associates 10 prospectively enrolled 1 EON patient (2.7%) from among 37 patients taking EMB and reported early thickening of peripapillary retinal nerve fiber layer (cprnfl) and thinning of the ganglion cell layer plus inner plexus layer (GCIPL) at the onset of symptoms. 10 The previous research work has not yet demonstrated whether these early structural changes are associated with visual prognosis or not. If there is a significant relationship between these structural changes and visual prognosis, this may provide invaluable information on the therapeutic window in which to prevent further structural damage to avoid irreversible visual loss. Therefore, we aimed to quantify the retinal thickness changes of cprnfl, macular RNFL (mrnfl), and GCIPL after stoppage of EMB in EON, and to establish a relationship between any structural changes and the amount of vision recovery. MATERIALS AND METHODS Subjects This hospital-based retrospective observational study was a single-center study performed from 2009 to 2016 in accordance with the tenets of the Declaration of Helsinki. This study was approved by the institutional review board of Samsung Medical Center. Patient records were anonymized and de-identified prior to analysis. All patients diagnosed with EON were reviewed. Patients were eligible for inclusion if they were receiving EMB doses for the treatment of pulmonary tuberculosis. Inclusion criteria were as follows: slowly progressive visual loss accompanied by dyschromatopsia after taking EMB, taking EMB for more than 2 months, normal appearance of the optic disc at the first visit, and absence of symptoms associated with optic neuritis, such as pain on ocular movement. All patients who reported any suspicious visual symptoms were referred Copyright 2018 The Authors iovs.arvojournals.org j ISSN: 1552-5783 2104 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Vision Recovery Predictor in Ethambutol Optic Neuropathy IOVS j April 2018 j Vol. 59 j No. 5 j 2105 immediately to the neuro-ophthalmology clinic and told to stop taking EMB. All subjects underwent Spectralis optical coherence tomography (OCT; Heidelberg Engineering, Heidelberg, Germany) after the onset of symptoms (visit 1) and at a followup visit (visit 2). We considered the retinal thickness measurements from visit 1 to be representative data. Only high-quality (Q values > 25) scans were included. The change in retinal thickness between visits 1 and 2 was used to evaluate a possible association with vision recovery. All study participants underwent a detailed ophthalmologic examination, including assessment of refraction, best-corrected visual acuity (BCVA), color vision, relative afferent pupillary defect, slit-lamp examination, tonometry, and a fundus examination. Exclusion criteria included the presence of concurrent retinal diseases, any history of glaucoma, and ocular surgery except for cataract surgery. Data on sex, age, duration of taking EMB, BCVA at first visit, presence of visual recovery, BCVA at 1, 3, 6, and 12 months after stoppage of EMB, and color vision examined by Hardy- Rand-Rittler (HRR) test were collected from the electronic records of each patient. Corrected visual acuities were transformed to a logarithmic scale (logmar) for statistical analysis. The amount of visual acuity recovery was calculated as the difference between the first BCVA logmar and the follow-up BCVA logmar at each visit. Image Acquisition and Retinal Layer Thickness Measurement One experienced technician (Y.L.) performed imaging on all subjects with disc and retinal Spectralis OCT (software version 1.6.4.0; Heidelberg Engineering). A 3608 3.4-mm-diameter peripapillary circle scan centered on the optic disc was performed for RNFL assessment, and all OCT scans were performed with spectral-domain (SD)-OCT that provided 40,000 A-scans/second with 7-lm optical and 3.5-lm digital axial resolution. Horizontal and vertical SD-OCT scans of the fovea were obtained for all subjects. All OCT images were converted to grayscale for better visualization and accurate analysis. The thickness of each retinal layer was measured automatically using the SD-OCT software. The thickness values for the inner locations (inner superior, inner nasal, inner temporal, and inner inferior) were measured in the Early Treatment Diabetic Retinopathy Study (ETDRS) central circular 1000-lm-diameter area. Thicknesses of the outer areas (outer superior, outer nasal, outer temporal, and outer inferior) were measured in the ETDRS circular 3000-lm-diameter area. Using this method, we acquired the thicknesses of the cprnfl, mrnfl at the outer locations, and GCIPL at the inner and outer locations. Main outcomes were grouped into two categories: each retinal layer thickness measurement at visit 1 (initial) and difference in each thickness measurement between visits 1 and 2. Statistical Analysis Statistical analyses were performed using SAS version 9.4 software (SAS Institute, Cary, NC, USA). We used the generalized estimating equation (GEE) with Bonferroni s correction to assess the associations between retinal thickness measurements and clinical factors. We described the relationships between thickness as a function of time with scatter plots fitted with a locally weighted regression smoothed nonparametric regression line. Both categories of OCT measurements were used for the analysis. Age, sex, laterality of EON, and timing of OCT after the onset of symptoms were adjusted. A P value < 0.05 was considered significant. All data were presented as mean 6 standard deviation. RESULTS We enrolled a total of 42 eyes in 21 patients, 9 males and 12 females (Table). The mean age was 59 6 12 years (range, 33 77 years). The mean time between the onset of symptoms and the first SD-OCT scan was 0.5 6 0.5 months (range, 0 1.2 months). Duration of taking EMB was 5.7 6 2.9 months (range, 2 12 months), and the mean dosage of EMB was 17.8 6 2.3 mg/kg (range, 15.0 22.8 mg/kg). No patient had prior history of EON. The symptoms at the first visit were gradual decrease in visual acuity in 15 (72%) patients, visual field constriction in 3 (14%) patients, and dyschromatopsia in 3 (14%) patients. These symptoms developed during taking EMB in all patients. BCVA was 0.83 6 0.43 logmar at the first visit and 0.99 6 0.42 logmar 1 month, 0.82 6 0.52 logmar 3 months, 0.69 6 0.42 logmar 6 months, and 0.38 6 0.54 logmar 12 months after stoppage of EMB. There was a significant difference in BCVA between the first visit and 1 month, between 1 and 3 months, between 3 and 6 months, and between 6 and 12 months (paired t-test, P ¼ 0.014, 0.026, 0.037, and < 0.0001, respectively). The mean interval between the initial and follow-up OCT was 6.2 6 0.6 months (range, 5.5 7.0 months). The mean thickness of cprnfl at the temporal, nasal, and inferior locations, inner GCIPL at the temporal, nasal, and inferior locations, and outer GCIPL at the superior and inferior locations was significantly thinner in the follow-up OCT than in the initial OCT (GEE with Bonferroni s correction: P ¼ 0.012, 0.014, 0.001, 0.003, 0.002, 0.048, 0.009, and 0.041, respectively) (Fig. 1). The longitudinal change in each thickness measurement is presented in Figure 2. Correlation Between Thickness Measurements and Vision Recovery A multivariable analysis between visit 1 retinal layer thicknesses and visual recovery showed that as the thickness of the temporal inner GCIPL increased, the degree of visual acuity improvement 12 months after discontinuation of EMB increased significantly (P < 0.001). In the inner GCIPL a 10- lm-thickness loss was associated with a 0.5 decrease in the amount of logmar visual acuity recovery at 12 months (95% confidence interval [CI]: 0.2 0.7). We found no significant correlation with the amount of visual acuity recovery at 1, 3, and 6 months. A scatter plot of the relationship between GCIPL measurements and the amount of visual acuity recovery is presented in Figure 3. A multivariable analysis between the change in thickness measurements between visits 1 and 2 and visual recovery showed that as the reduction in temporal inner GCIPL and superior cprnfl increased between visits 1 and 2, the degree of visual acuity improvement 12 months after discontinuation of EMB decreased significantly (P < 0.001 and 0.09, respectively). In the inner GCIPL, a 10-lm-thickness reduction was associated with a 0.5 decrease in the amount of logmar visual acuity recovery (95% CI: 0.3 0.7); in the superior cprnfl, a 10-lm-thickness reduction was associated with a 0.5 decrease in the amount of logmar visual acuity recovery at 12 months (95% CI: 0.2 0.8). Other Clinical Factors Correlated With Visual Recovery Two other clinical factors, duration of medication (interval between starting EMB and the first visual symptoms) and initial BCVA, were significantly correlated with visual acuity recovery. As duration of medication use increased, the degree of visual acuity recovery decreased 3, 6, and 12 months after stoppage

Vision Recovery Predictor in Ethambutol Optic Neuropathy IOVS j April 2018 j Vol. 59 j No. 5 j 2106 FIGURE 1. The change in mean thickness measurements of peripapillary retinal nerve fiber layer (cprnfl), macular RNFL, and ganglion cell layer plus inner plexus layer (GCIPL) between initial and follow-up visits in patients with ethambutol-induced optic neuropathy (asterisks: P < 0.05). of EMB (all P < 0.001). Also, the lower the initial BCVA was at the first visit, the greater the visual acuity improvement was 12 months after stoppage of EMB (P < 0.001). This study has an 80% or greater power to evaluate the difference in temporal GCIPL thickness between visits 1 and 2. DISCUSSION Many trials have been done to evaluate structural changes to the disc and retina in early-stage EON because OCT clearly demonstrates the structural loss of particular retinal layers, despite a near-normal appearance of the fundus. Early GCIPL loss, which refers to primary axonal loss in some optic neuropathies, was previously reported. 14,15 Balducci et al. 14 detected damage to the GCIPL starting 6 weeks before visual loss in Leber s hereditary optic neuropathy (LHON). Viera et al. 15 reported a 34% to 40% decrease in the thickness of the retinal ganglion cell layer (compared with a control group) in eight patients with EMB-induced and nutritional optic neuropathy. 15 In the present longitudinal analysis, we also observed initial cprnfl swelling within 3 months after symptom onset. Initial decrease of GCIPL, reflecting early axonal damage caused primarily by EMB toxicity, was more remarkable in inner locations than in outer locations. The results were similar to those in a previous study reporting early swelling of cprnfl and an early decrease in the perifoveal GCIPL. 10 The amount of reduction in the cprnfl during follow-up was much greater than in the GCIPL (visit 1 versus visit 2). Despite greater reduction in cprnfl, GCIPL values are preferable to cprnfl or mrnfl values due to earlier expression of structural damage compared to cprnfl for detecting early neuronal loss caused by EON, whereas during the progression of EON, structural changes to the cprnfl should also be carefully observed. Our most important finding was that the amount of reduction in temporal GCIPL thickness negatively correlated with the degree of vision recovery. Some studies previously reported a relationship between visual acuity and GCIPL thickness that was related to the pathophysiology of each optic neuropathy. Kim et al. 16 demonstrated that thinning of the superior and inferior GCIPL was significantly correlated with visual acuity in severe glaucoma, and Moster et al. 17 reported that a decrease in GCIPL thickness was associated with worsening vision in the acute phase of LHON. 17 In addition to those optic neuropathies, we found a significant effect of GCIPL thickness on the potential for visual recovery in patients with EON. In our results, as the thickness of the remaining GCIPL increased and the damage to the GCIPL decreased during 6 months of follow-up, the possibility of visual acuity recovery before permanent retinal ganglion cell death increased. That result suggests the importance of preventing early axonal damage and further deterioration, particularly before ganglion cell death, for long-term visual recovery. This finding could be helpful to other researchers investigating therapeutic targets and devising a cure for EON in the future. In a previous study of EON, Zoumalan et al. 11 observed 79% of mean loss in temporal cprnfl thickness, and the proportion of nerve fiber loss was greater in temporal cprnfl thickness than in nasal, inferior, and superior cprnfl thickness in subjects with acute and persistent vision loss. In relation to visual acuity, those authors emphasized the

Vision Recovery Predictor in Ethambutol Optic Neuropathy IOVS j April 2018 j Vol. 59 j No. 5 j 2107 FIGURE 2. Peripapillary retinal nerve fiber layer (cprnfl), macular RNFL, and ganglion cell layer plus inner plexus layer (GCIPL) thickness during ethambutol-induced optic neuropathy progression. temporal segmental loss of the cprnfl in EON, which is related to the papillomacular bundle. Based on their results, the nasal GCIPL could be expected to correlate with visual acuity because it is directly adjacent to the papillomacular bundle. However, contrary to our expectation, only the temporal inner GCIPL showed a significant correlation with visual recovery. This result can be explained by the severity of EON expressed in the segmental damage regarding the GCIPL. In patients with significant temporal thinning of the GCIPL, significant nasal thinning of the GCIPL was also observed. Thus, the nasal GCIPL might commonly have been damaged. Therefore, further GCIPL thinning at the temporal location could indicate more severe axonal damage and the process of global atrophy. Thus, temporal GCIPL thinning could be related to poorer visual acuity and become a reflection of the severity of EON. Moreover, any change in temporal structural loss should be carefully considered in EON since the axonal damage caused by EMB toxicity might not be limited to the papillomacular bundle. Early GCIPL thinning that is present at symptom onset commonly precedes cprnfl changes that increase at symptom onset and subsequently normalize at 6 months 10 ; we would thus recommend using the temporal GCIPL over the cprnfl or mrnfl as an anatomic marker to predict visual acuity improvement in early-phase EON. FIGURE 3. A scatter plot of the relationship between inner temporal GCIPL measurements and the amount of visual acuity recovery at 12 months after discontinuation of drug.

Vision Recovery Predictor in Ethambutol Optic Neuropathy IOVS j April 2018 j Vol. 59 j No. 5 j 2108 TABLE. The Descriptive Statistics of All Subjects Variable EON, n ¼ 21 Mean 6 SD Age, y (range) 59 6 12 (33 77) Sex, M/F 9/12 Visual acuity, logmar First visit 0.83 6 0.43 1 month after EMB stoppage 0.99 6 0.42 3 months after EMB stoppage 0.82 6 0.52 6 months after EMB stoppage 0.69 6 0.42 12 months after EMB stoppage 0.38 6 0.54 Refractive error, prism diopter 1.69 6 2.26 Color vision, HRR/no. of test plates 0.24 6 0.41 Number of OCT examinations, n 1 exam 9 2 exams 6 3 exams 3 4 exams 3 In addition to the GCIPL thickness itself, the amount of temporal GCIPL loss during 6 months was also negatively associated with the amount of vision recovery at 12 months. To predict vision improvement, careful checkups are required not only for initial GCIPL thickness in early-stage EON, but also for the amount of temporal GCIPL change according to disease progression. In cases with considerable loss of the temporal GCIPL in early-stage EON, we recommend careful observation of the progressive loss of the temporal GCIPL because of the possibility of further visual loss and a reduced possibility of vision recovery. The daily dosage of EMB ranged from 15 to 22.8 mg/kg in EON patients. It was consistent with that in a previous study reporting that EMB may cause optic neuropathy if the daily dosage exceeds 15 mg/kg. 18 Among other factors, duration of EMB and initial BCVA were also correlated with visual prognosis in this study. Initial visual acuity was negatively correlated with the amount of vision recovery. Similar to previous studies reporting a correlation between the duration of EMB and the risk of toxicity, 19,20 we found that the duration of EMB could affect visual prognosis. In contrast, a 10-year study reported that no obvious prognostic factors including duration of EMB and initial BCVA were found to facilitate vision recovery. 5 Hence, regarding clinical factors, further wellcontrolled studies are required to predict visual acuity recovery. It is of note that EON continued to progress even after stoppage of EMB. We found that visual acuity significantly decreased within 1 month after stoppage of EMB, then gradually improved after 1 month. Similar to this result, much research work has demonstrated reversal of the toxicity induced by EMB after 1 month of stoppage of the drug, and recovery may occur as late as 1 year after discontinuation of EMB. 21 During the early progression phase after stoppage of EMB, it is very challenging to predict patients visual prognosis. According to the results of the present study, early evaluation of GCIPL damage may provide important information to clinicians about vision recovery in this confusing early period. In addition, our results suggest that EMB toxicity may not be limited to the papillomacular bundle; thus we direct clinician attention to a careful evaluation not only of nasal GCIPL damage (regarding the papillomacular bundle), but also of temporal GCIPL damage, which may seem relatively less important. This study has the following limitations. First, this was a retrospective, single-center study, and the sample size was relatively small. Because our results are retrospective, we could not determine the threshold of EMB dosage, and clinicians should use caution in uniform application to patients with EON. Second, long-term evaluation between clinical factors and retinal thickness could not be performed. Since the plan was immediately stop ethambutol and regular observation after EON diagnosis, most patients with a short follow-up were managing their tuberculosis in a hospital nearer to their hometown, thus were referred to the hospital again. Third, the relationships between retinal thickness and other visual factors including color vision and visual field defects were not analyzed. Therefore, prospective studies are needed to verify our results. Acknowledgments Disclosure: J.-Y. Lee, None; J.H. Choi, None; K.-A. Park, None; S.Y. Oh, None References 1. Sadun AA, Wang MY. Ethambutol optic neuropathy: how we can prevent 100,000 new cases of blindness each year. J Neuroophthalmol. 2008;28:265 268. 2. Lee EJ, Kim SJ, Choung HK, Kim JH, Yu YS. Incidence and clinical features of ethambutol-induced optic neuropathy in Korea. J Neuroophthalmol. 2008;28:269 277. 3. Ezer N, Benedetti A, Darvish-Zargar M, Menzies D. Incidence of ethambutol-related visual impairment during treatment of active tuberculosis. Int J Tuberc Lung Dis. 2013;17:447 455. 4. Boman G, Calissendorff B. A case of irreversible bilateral optic damage after ethambutol therapy. Scand J Respir Dis. 1974; 55:176 180. 5. Chen SC, Lin MC, Sheu SJ. Incidence and prognostic factor of ethambutol-related optic neuropathy: 10-year experience in southern Taiwan. Kaohsiung J Med Sci. 2015;31:358 362. 6. Kumar A, Sandramouli S, Verma L, Tewari HK, Khosla PK. Ocular ethambutol toxicity: is it reversible? J Clin Neuroophthalmol. 1993;13:15 17. 7. Tsai RK, Lee YH. Reversibility of ethambutol optic neuropathy. JOculPharmacolTher. 1997;13:473 477. 8. Chan RY, Kwok AK. Ocular toxicity of ethambutol. Hong Kong Med J. 2006;12:56 60. 9. Kim U, Hwang JM. Early stage ethambutol optic neuropathy: retinal nerve fiber layer and optical coherence tomography. Eur J Ophthalmol. 2009;19:466 469. 10. Han J, Byun MK, Lee J, Han SY, Lee JB, Han SH. Longitudinal analysis of retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in ethambutol-induced optic neuropathy. Graefes Arch Clin Exp Ophthalmol. 2015;253: 2293 2299. 11. Zoumalan CI, Agarwal M, Sadun AA. Optical coherence tomography can measure axonal loss in patients with ethambutol-induced optic neuropathy. Graefes Arch Clin Exp Ophthalmol. 2005;243:410 416. 12. Chai SJ, Foroozan R. Decreased retinal nerve fibre layer thickness detected by optical coherence tomography in patients with ethambutol-induced optic neuropathy. Br J Ophthalmol. 2007;91:895 897. 13. Gumus A, Oner V. Follow up of retinal nerve fiber layer thickness with optic coherence tomography in patients receiving anti-tubercular treatment may reveal early optic neuropathy. Cutan Ocul Toxicol. 2015;34:212 216.

Vision Recovery Predictor in Ethambutol Optic Neuropathy IOVS j April 2018 j Vol. 59 j No. 5 j 2109 14. Balducci N, Savini G, Cascavilla ML, et al. Macular nerve fibre and ganglion cell layer changes in acute Leber s hereditary optic neuropathy. Br J Ophthalmol. 2016;100:1232 1237. 15. Vieira LM, Silva NF, Dias dos Santos AM, et al. Retinal ganglion cell layer analysis by optical coherence tomography in toxic and nutritional optic neuropathy. J Neuroophthalmol. 2015; 35:242 245. 16. Kim JH, Lee HS, Kim NR, Seong GJ, Kim CY. Relationship between visual acuity and retinal structures measured by spectral domain optical coherence tomography in patients with open-angle glaucoma. Invest Ophthalmol Vis Sci. 2014; 55:4801 4811. 17. Moster SJ, Moster ML, Scannell Bryan M, Sergott RC. Retinal ganglion cell and inner plexiform layer loss correlate with visual acuity loss in LHON: a longitudinal, segmentation OCT analysis. Invest Ophthalmol Vis Sci. 2016;57:3872 3883. 18. Rennie IG. Clinically important ocular reactions to systemic drug therapy. Drug Saf. 1993;9:196 211. 19. Chen HY, Lai SW, Muo CH, Chen PC, Wang IJ. Ethambutolinduced optic neuropathy: a nationwide population-based study from Taiwan. Br J Ophthalmol. 2012;96:1368 1371. 20. Talbert Estlin KA, Sadun AA. Risk factors for ethambutol optic toxicity. Int Ophthalmol. 2010;30:63 72. 21. Menon V, Jain D, Saxena R, Sood R. Prospective evaluation of visual function for early detection of ethambutol toxicity. Br J Ophthalmol. 2009;93:1251 1254.