JuggerKnot Soft Anchor 1.0 mm Mini

Similar documents
JuggerKnot Soft Anchor 1.0 mm Mini

JuggerKnot Soft Anchor 1.0 mm Mini. Scapholunate Ligament Repair/Reconstruction. Brochure and Surgical Technique

JuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair

JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair

Femoral Fixation for ACL Reconstruction. Surgical Protocol by Mark Gittins, D.O.

JuggerKnot and JuggerKnotless Soft Anchor. All-Inclusive Brochure

DermaSpan Acellular Dermal Matrix. Reinforcement of Ruptured Posterior Tibial Tendon Repair. Surgical Protocol by Charles Zelen, DPM, FACFAS

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

MCL Reconstruction Surgical Protocol by Tarek Fahl, M.D.

HIP ARTHROSCOPY BROCHURE

Lateral Ankle Ligamentous Instability. Surgical Technique by Jeffrey Nacht, M.D.

SureLock All-Suture Anchor System

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

3.0 mm Cannulated Screw System. Surgical Technique

ToggleLoc Inline Device

ComposiTCP Anchor with BroadBand Tape

ToggleLoc. Fixation Device. Surgical Technique. Femoral Fixation for ACL Reconstruction SPORTS MEDICINE. Surgical Protocol by Mark Gittins, D.O.

BTB ACL Reconstruction with the ToggleLoc Fixation Device with ZipLoop Technology. Surgical Technique by James R. Andrews, M.D.

Biomet Multi-Axial Correction (MAC) System Correction Atlas

DVR Crosslock Distal Radius Plating System. Product Brochure

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

Biologically-Assisted ACL Reconstruction. Surgical Technique

Peanut Growth Control Plating System

Coracoid Bone Conserving Acromioclavicular Joint Reconstruction using ToggleLoc Device with ZipLoop Technology

Signature Personalized Patient Care

StageOne. Shoulder Cement Spacer Molds. Surgical Technique

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

with ACL Reconstruction Single Tibial Tunnel Double Bundle Surgical Protocol by Eric McCarty, M.D.

OSS Modular Arthrodesis System. Assembly Guide

CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique

Medial Portal ACL Reconstruction

Hip Arthroscopy. All Inclusive Brochure

Taperloc Complete Hip System. Surgical Technique

Platelet Separation Kit

CoAxial Spray Kit. Simplifying the Application of Platelet-Rich Plasma onto Graft Material. Surgical Technique

Vanguard. Total Knee System

Arthroscopic and Mini-Open Rotator Cuff Repair. using JuggerKnot Soft Anchor 2.9 mm with ALLthread Knotless PEEK-Optima Anchor Surgical Technique

Midfoot Repair. Surgical Protocol by Stuart Miller, M.D.

Correction System. Surgical Technique

ACL Reconstruction Single Tibial Tunnel Double Bundle

The AperFix II System

OSS Orthopedic Salvage System Compress Device. Surgical Technique

Platelet Separation Kit

Surgical Protocol written by Keith Lawhorn, M.D.

Arthroscopic and Mini-Open Rotator Cuff Repair

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D.

G7 ACETABULAR SYSTEM. beautifully. efficient.

Thumb UCL Repair with InternalBrace Ligament Augmentation. Surgical Technique. Thumb UCL Repair with InternalBrace Augmentation

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

ToggleLoc Fixation Device with ZipLoop Technology

ACL Reconstruction Medial Portal

CrossTIE. PIP Arthrodesis Implant. surgical technique ordering information PEEK IMPLANTS PEEK IMPLANTS ALLOGRAFT IMPLANTS CROSSTIE INSERTER

Ulnar Collateral Ligament Injuries of the Thumb Game Keeper s Thumb A Patient's Guide to Ulnar Collateral Ligament Injuries of the Thumb

Silicone PIP, MCP & MCP-X (PreFlex)

CableFIX Xpress Carpometacarpal Fixation System. Operative technique

Correction System. Surgical Technique

Surgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6

Surgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6

Features. The hollow core can be filled with autograft or allograft bone.

FastFrame External Fixation System. Damage Control Surgical Technique

Technique Guide. VersiTomic. ReelX STT Double-Row Achilles G-Lok. J. Martin Leland III, M.D. J. Martin Leland III, M.D. Proximal Biceps Tenodesis

Surgical Technique Guide

SternaLock Blu PRIMARY CLOSURE SYSTEM

NEUFLEX MCP/PIP FINGER JOINT IMPLANT SYSTEMS SURGICAL TECHNIQUE. This publication is not intended for distribution in the USA.

Precautionary Statement ( )

StageOne Knee Cement Spacer Molds. Surgical Technique

Flexible Fragment Fixation. Surgical Technique

Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Vault Reconstruction System. Meet Your Match

FINGER INJURIES. Chapter 24, pgs ,

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

Arcos Modular Femoral Revision System

Comprehensive Reverse Shoulder System

Biomet. Vision Pin-To-Bar System. Surgical Technique. Calcaneal Reduction Frame

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

MIS Cemented Tibial Component

Transfemoral Amputation

MULTIFIX S Knotless Implants

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Surgical Technique Carpal Fusion

MSP TM Metatarsal Shortening System. Surgical Technique

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE

Correction System. Surgical Technique

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

Surgical Protocol by E. Lyle Cain, M.D. and Jeffrey R. Dugas, M.D. of the American Sports Medicine Institute

Silicone Finger Implant

GRAVITY Plantar Plate Repair System SURGIC AL TECHNIQUE

FLH /11

Acu-Loc Wrist Spanning Plate System. Surgical Technique

Clover Staple. Surgical Technique

DFS Hip Distractor. Surgical Technique

Metacarpophalangeal Joint Implant Arthroplasty REHABILITATION PROTOCOL

Peanut Growth Control Plating System

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant

Transcription:

JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Surgical Technique Surgical Protocols by Mark Rekant, M.D. A. Lee Osterman, M.D.

One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical care is to provide the right solution for each individual patient. This requires clinical mastery, a human connection between the surgeon and the patient, and the right tools for each situation. At Biomet, we strive to view our work through the eyes of one surgeon and one patient. We treat every solution we provide as if it s meant for a family member. Our approach to innovation creates real solutions that assist each surgeon in the delivery of durable personalized care to each patient, whether that solution requires a minimally invasive surgical technique, advanced biomaterials or a patient-matched implant. When one surgeon connects with one patient to provide personalized care, the promise of medicine is fulfilled.

The JuggerKnot Soft Anchor 1.0 mm Mini represents the next generation of suture anchor technology. The 1.0 mm deployable anchor is completely suture-based and the first of its kind. With over 75,000 anchors sold, the award-winning JuggerKnot Soft Anchor is now designed specifically for hand and wrist procedures. The new configuration includes two T-28 tapered needles to aid in soft tissue reattachment. The JuggerKnot Soft Anchor 1.0 mm Mini is indicated for: Repair/Reconstruction of collateral ligaments Scapholunate ligament reconstruction Ulnar or lateral collateral ligament reconstruction Flexor and extensor tendon at the PIP, DIP, and MCP joints for all digits. 100% suture anchor Available with either #2-0 or #3-0 suture #1 MaxBraid Suture Polyester Sleeve 26 lbs of pull-out strength for #2-0 suture and 20 lbs of pull-out strength for #3-0 suture 1 Sleeve protector eliminates need for drill guide Two T-28 tapered needles Drill hole is only 1 mm 1. Data on file at Biomet, Inc. Bench testing results are not indicative of clinical performance.

JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Figure 1 Patient Prep Injured extremity is prepped and draped in the usual sterile fashion. Esmarch bandage is utilized for extremity exsanguination. Inflate tourniquet to 250 mm Hg. Incision Centered over the Metacarpal/Phalangeal joint make a curvilinear S shaped incision extending approximately 3 4 centimeters (Figure 1). This brochure demonstrates the surgical technique and post operative care protocol utilized by Mark Rekant, M.D. and A. Lee Osterman, M.D. Biomet as the manufacturer of this device does not practice medicine and does not recommend this device or technique. Each surgeon is responsible for determining the appropriate device and technique to utilize on each individual patient. 2

Figure 2 Figure 3 Elevate the thick skin flaps. Identify the dorsal ulnar sensory branch to thumb and mobilize and retract volarly or dorsally. Be sure to protect the nerve. Expose and identify the adductor aponeurosis (Figure 2). Prepare the UCL for Reattachment Incise the adductor aponeurosis leaving a 2 3 mm cuff of tissue dorsally (Figure 3). Care should be taken to preserve the dorsal capsule layer. Mobilize soft tissues to allow for retraction of the extensor tendon dorsally and the adductor aponeurosis volarly. This will allow exposure and full mobilization of the torn Ulnar Collateral Ligament (UCL). This ligament typically avulses distally from base of the proximal phalanx in a proximal direction. The UCL should now be fully prepared for reattachment. 3

JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Figure 4 Figure 5 Anchor Placement Determine placement of the first JuggerKnot anchor. The bone origin for reattachment should be at the base of the proximal phalanx (Figure 4). The isometric point should be roughed with bone rongeur to promote healing of the UCL to bone. A similar process can be performed for avulsions of the UCL from the metacarpal head using the ligament origin as the point of reference. Open a sterile packed JuggerKnot implant and using the enclosed step drill, prepare the pilot hole by inserting the step drill to the stop or full depth (Figure 5). To reach full depth it is preferred to drill at an angle as perpendicular to the bone surface as possible. This is important for full deployment of the anchor. 4

Figure 7 Figure 8 Figure 6A Figure 6 Figure 9 Figure 10 Anchor Placement (Cont.) Locate pilot hole with tip of JuggerKnot inserter (Figure 6A). The angle of insertion must be the same trajectory as the pilot hole. Failure to do this could prevent insertion and deployment of the anchor. Apply gentle pressure to the JuggerKnot inserter to start advancement of anchor (Figure 6, 6A). Unscrew lure lock to release sutures and pull foam tab to release needles (Figure 9). Remove JuggerKnot inserter by gently pulling straight up on the handle. This will separate the anchor from the inserter, leaving the anchor in the pilot hole (Figure 10). Advance the inserter until the clear JuggerKnot guide sleeve has retracted to the handle completely (Figure 7). Note: At this point, do not pull up on the handle to set anchor (Figure 8). 5

JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Figure 11B Figure 11A Figure 11C Figure 12 Anchor Placement (Cont.) Set the anchor by lightly pulling back on both strands of suture (Figures 11A /11B). The 2-0 or 3-0 suture should move back and forth freely within the all-suture anchor (Figure 11C). Reattach the UCL Using the attached needles, re-attach the UCL utilizing a horizontal mattress stitch technique (Figure 12). This will allow for tensioning of the ulnar collateral ligament (UCL) to the cortical bone surface. 6

Figure 13 Figure 14 Closure Repair the adductor aponeurosis with 4-0 resorbable suture (Figure 13). Deflate the tourniquet and irrigate the wound. Hemostasis is assured with electrocautery bipolar. Post Operative Care For rehabilitation, immobilize the thumb MP joint for six weeks with a hand based removable thermoplastic splint or short arm thumb spica cast. Repair the skin incision (Figure 14) and apply a short arm splint. 7

JuggerKnot Soft Anchor 1.0 mm Mini Ulnar Collateral Ligament (UCL) Repair of the Thumb Implants JuggerKnot Soft Anchor 1.0 mm Mini with 2-0 Suture Part Number Description Size 912076 912080 JuggerKnot Soft Anchor 1.0 mm Mini 2-0 Needles with Drill-Single JuggerKnot Soft Anchor 1.0 mm Mini 2-0 with Needles 10pk 2-0 Suture 2-0 Suture JuggerKnot Soft Anchor 1.0 mm Mini with 3-0 Suture Part Number Description Size 912082 912084 JuggerKnot Soft Anchor 1.0 mm Mini 3-0 Needles with Drill-Single JuggerKnot Soft Anchor 1.0 mm Mini 3-0 with Needles 10pk 3-0 Suture 3-0 Suture Instruments JuggerKnot Soft Anchor 1.0 mm Mini 2-0 Part Number Description Size 912077* JuggerKnot Soft Anchor 1.0 mm Mini Step Drill (Sterile) 1.0 mm *Provided as a backup since each JuggerKnot Soft Anchor 1.0 mm Mini is packages with a sterile step drill.

This material is intended for health care professionals and the Biomet sales force only. Distribution to any other recipient is prohibited. All content herein is protected by copyright, trademarks and other intellectual property rights owned by or licensed to Biomet Inc. or its affiliates unless otherwise indicated. This material must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Biomet. Check for country product clearances and reference product specific instructions for use. For complete product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the package insert and Biomet s website. This technique was prepared in conjunction with a licensed health care professional. Biomet does not practice medicine and does not recommend any particular orthopedic implant or surgical technique for use on a specific patient. The surgeon is responsible for determining the appropriate device(s) and technique(s) for each individual patient. Not for distribution in France. Legal Manufacturer Biomet Sports Medicine 56 East Bell Drive P.O. Box 587 Warsaw, Indiana 46581 USA Authorised Representative Biomet UK Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA UK 0086 2014 Biomet Sports Medicine Form No. BMET0676.0-GBL REV0614 www.biomet.com