Straumann Original Clinical Review. General Information

Similar documents
The difference is obvious. Original components by Straumann

More than a Ti-base. Your trusted link between implant and restoration. Straumann Variobase C. Variobase for CEREC becomes Variobase C

More than pure esthetics. The natural and strong solution.

More than a beautiful smile. A new quality of life with dental implants.

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

Straumann Dental System Indication-based prosthetic workflow. Technical Information

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

Patient information on Straumann Dental Implants. More than a dental implant. A confident smile.

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Product Information. Straumann Novaloc. A reliable connection that endures.

Guidance for. implant removal. Straumann Dental Implant System

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

Straumann PURE Ceramic Implant System Discover natural PURE white. Love your smile. Product Information

Straumann PURE Ceramic Implant Monotype Discover natural PURE white. Love your smile. Product Information

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

the way to straumann cares abutments

Straumann. This is a real breakthrough. Roxolid implant, make the restoration, then go home and sleep well at night.

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

More than an implant. A sense of trust. Straumann Dental Implant System

More than an implant. A sense of trust.

Straumann Guided Adapter. Basic information on. the Straumann Guided Adapter

Straumann Basic Guided Surgery Cassette. More than a simple cassette. A smart Guided Surgery solution.

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

Straumann SmartOne. Stage 4 Af terc are and maintenance. Step 2 Maintenance visit

Straumann Dental Implant System. Fax Order Form Collection.*

Straumann CARES Prosthetics. More than efficiency. Cost-effective workflow solutions.

More than a short implant.

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

Standard Plus Implant

CPD Article ISSUE 33. Proud of our History, Looking Forward to the Future

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE


Product Information. Straumann CARES Scan & Shape Turn into digital.

Straumann CARES Prosthetics More than efficiency. Cost-effective workflow solutions. Product Information

3. Guarantee conditions

Mechanical and technical risks in implant therapy.

Straumann SLActive. More than a unique implant surface. Maximizing treatment success and predictability.

CPD Article ISSUE 42. Proud of our History, Looking Forward to the Future

More than a fixed rehabilitation.

Implant osseointegration and successful restoration

Training & Education Solution. Straumann Smart Immerse to succeed. DISCOVER THE WORLD OF IMPLANT DENTISTRY WITH US.

Straumann CARES Prosthetics. More than efficiency. Cost-effective workflow solutions.

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Bridging the Gap Between Original and Multi-Platform Systems.

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

More than creating smiles. Restoring confidence. Company profile

STRAUMANN CARES CUSTOMIZED PROSTHETIC SOLUTIONS

Objectives: Previous studies that evaluated the torque needed for removing dental

Restoring Straumann implants. with Locator abutments.

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

Straumann n!ce Turn time spent milling into time spent smiling. Quick Guide

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

Straumann ProClean Cassette. Uncompromised hygiene. Ready for action.

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

SPECIALIST IN CUSTOMIZED PROSTHETICS

SCREW LOOSENING has been reported as

Straumann Roxolid. More than solid Roxolid. Reducing invasiveness.

User Manual Complete Prosthetic Kit (CPK)

WHERE CREATIVITY MEETS TECHNOLOGY E CREATECH EXCELLENCE. State-of-the-art technology for your prostheses

Rock-solid fit. A connection you can depend on. Internal Hex with Friction-Fit

Laboratory Solutions. Optimization By Design

straumann Guided surgery Access to the Digital Experience

Straumann Screw-retained Prosthetics

JD Implant: 10 reasons for the best choice

Straumann ProClean Cassette. Basic Information on the

Zfx GenTek Genuine Restorations and Open Digital Workflows. Easy, fast, genuine.

For technical assistance: Tel Working time: 8.30 am pm

Straumann PURE. Ceramic Implant. Clinical Review

Product Information. Straumann CARES Scan & Shape Turning into digital solutions.

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Guided surgery manual

CHECK-UP Determination of Impression type & Method after implant placement

Straumann Guarantee. Straumann

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

Overcoming and Preventing Dental Implant Complications: Abutment Fracture Case Report

Stock Prosthetic Guide 2014

seamless connections

Patient information on the treatment of gum disease. More than 2 million patients treated. Saving teeth for more than 20 years Straumann Emdogain

» For multi-unit restorations -

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

Straumann CARES Intraoral Scanner. Capture each note.

A retrospective study on separate single-tooth implant restorations to replace two or more consecutive. maxillary posterior teeth up to 6 years.

FlexLink TiBase. Sustainable Aesthetic Solution

Creating emergence profiles in immediate implant dentistry

More than a denture. A new and natural-looking smile.

G03: Complications 12/7/2013 8:00AM 4:30PM

2. STRAUMANN PRODUCTS COVERED BY THE STRAUMANN GUARANTEE. Abutment attached to an implant* Replacement with equivalent ceramic abutment**

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Implant Restorations: A Step-By-Step Guide

NobelParallel Conical Connection Product overview

3D-Guide. Scanbody for high-precision implant position transfer INTERNATIONAL PATENT BENEFITS: APPLICATION: TECHNICAL DETAILS:

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

Being the partner of choice

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Transcription:

Straumann Original Clinical Review General Information

Perfect, precise components match Proven mechanical performance Long-term clinical effect

PROVEN MECHANICAL PERFORMANCE A number of studies have investigated the difference between original and non-original abutments and came to interesting conclusions. In a study by Kim et al., screw loosening was assessed by comparing three different non-original abutments with the originals manufactured by Straumann. All abutments were mounted onto Straumann Tissue Level Implants and then tested in an in vitro fatigue test environment. In two of the three non-original systems, the test resulted in fractures of either the implant or the abutment. Only one of the non-original abutment systems survived the test, although with significant lost torque. Only the original Straumann abutment did not show any loosening or fracture of the abutment in this test environment. Therefore, the authors recommended the use of both implant and abutment manufactured by the same company so as to prevent abutment screw fracture (Kim et al., 2012). In another study, Gigandet et al. evaluated the rotational misfit of original implant-abutment connections compared to non-original abutments. CADCAM-manufactured original and non-original abutments from two manufacturers were tested, each connected to the Straumann reduced-diameter implants. The study demonstrated a significantly higher rotational misfit for the abutments of one of the tested third-party manufacturers on Straumann implants compared to the original Straumann implant-abutment system. The test could not be performed on the abutments of the second third-party manufacturer since all abutments were oversized and did not fit properly into the Cross- Fit connection of the Straumann implants. The authors further concluded that non-original abutments differ from originals with regards to the design of the connecting surface, shape, dimensions and material. Non-original abutments also present a higher rotational misfit that may eventually lead to fracture of the implant or the abutment (Gigandet et al., 2014). The micro-mobility of the implant-abutment interface for original and nonoriginal abutments was recently evaluated (Keilig et al., 2013). Standard CADCAM Straumann abutments and abutments from two third-party manufacturers were mounted on Straumann implants and subjected to a fatigue test. The

authors demonstrated that the mobility of the implant-abutment interface varied significantly in non-original abutments compared to original components. While in the best case, non-original abutments demonstrated micro-mobility comparable to the original, in some micro-mobility was higher. Thus, the authors concluded that the use of original components offers higher predictability in precision fit. The subject of non-original abutments was also studied by Mattheos et al. The authors investigated the morphological micro-features of three commercially available abutments (one original and two from systems claiming compatibility) loaded on the Straumann regular neck implant. They reported that, although the tight contact in the implant shoulder was similar in all three investigated abutments, the engagement of the internal connection as well as the anti-rotation elements were compromised in the compatible abutments. Such differences may in fact lead to serious consequences in the long-term stability of the prosthesis (Matheos at al., 2015). Original Straumann abutment Compatible abutment Fig. 1 Examples of an area of tight (left) and non-tight (right) contact between abutment and implant shoulder. The abutments were torqued on original Straumann RN implants. Courtesy of Dr N. Mattheos In addition, there are case reports of situations where patients with non-original components sought help following technical and biological complications with their implant-borne prosthesis that had been made elsewhere in the world. Very often, third-party components showed visible morphological differences compared to original components. The mechanical properties and clinical performance can be significantly affected by these differences (Mattheos et al., 2012).

The studies presented above point to higher rotational misfit, stronger effect of screw loosening and greater variance in precision fit of non-original components when compared to the corresponding original components. All these differences may result in unexpected failure and can even have an adverse effect upon clinical performance. DID YOU KNOW? No long-term clinical data exist for the non-original components and therefore, their long-term performance has not been proven. LONG-TERM CLINICAL EFFECT Although most long-term clinical studies in dental implantology assess the performance of the endosteal implant itself, there are a number of studies that have documented the performance of the prosthetic components including the abutments. Wittneben et al. presented a 10-year retrospective analysis of the rate of mechanical complications in prosthetic restorations. The authors assessed prosthetic restorations in all 388 surviving Straumann Tissue Level Implants. They found that after 10 years, only 3 % (n = 13) of the secondary prosthetic components showed complications (Fig. 2). These reported complications included: loosening of the occlusal screw in 2.5 % (n = 10) of cases and fracture of the occlusal screw or loosening/fracture of the abutments in less than 1 % (n = 3) of cases (Wittneben et al., 2014). Complications 3 % n = 13 Success 97 % n = 375 n = 388 Fig. 2 97 % success rate for Straumann original secondary prosthetic components (Wittneben et al., 2014).

Another prospective 10-year clinical study reported only 1.5 % (n = 2) mechanical complications of the prosthetic parts in 132 dental implants (one loose assembly screw which was observed twice in one patient (Fig. 3)). No fractures of abutments, abutment screws, or assembly screws were documented during the 10 years of functioning (Fischer et al., 2013). Mech. complications 1.5 % n = 2 Success 98.5 % n = 130 n = 132 Fig. 3 10-year success rate of 98.5 % for Straumann prefabricated prosthetic secondary components (Fischer et al., 2013). Finally, in a 20-year study, in partially edentulous patients, the performance of 95 Straumann implants was documented by Chappuis et al. Mechanical complications related to prefabricated components were observed in only 3 % (n = 3) of cases (Fig.4). These included a fractured abutment in a fixed dental prosthesis with cantilever in one patient, and screw loosening in two patients (Chappuis et al., 2013). Mech. complications 3 % n = 3 Success 97 % n = 92 n = 95 Fig. 4 20-year success rate of 97 % for Straumann prefabricated prosthetic secondary components (Chappuis et al., 2013). As presented above, use of original prosthetic components provides reproducible high stability of the implant - abutment connection. It also minimizes a risk of any mechanical complications and guarantees long-term clinical performance of the implant.

PERFECT, PRECISE COMPONENTS MATCH DID YOU KNOW? In recent years, an increasing number of third-party manufacturers have copied prosthetic components and claim compatibility with those of the original implant systems. At first glance, the design of non-original abutments seems to be equivalent to the corresponding originals. In fact, however, there are differences that cannot be seen, but that can only be perceived in a cross-section examination of the implant-abutment system. Moreover, there are parameters that demonstrate why these non-original abutments are never 100 % identical to the originals. Every manufacturer defines the exact dimensions and tolerances for the production of its implants, abutments as well as for the implant-abutment connection. These tolerances are not known to any of the manufacturers of non-original abutments, therefore they need to determine the dimensions of the original implant-abutment interface by measuring the individual parts. This may lead to serious consequences as regards the performance of non-original abutments. DID YOU KNOW? An abutment which does not match perfectly into the implant can potentially lead to loosening of the screws of the abutment and, subsequently, to fracture of the abutment, screw or even the implant (Kano et al., 2006). 1 2 3 4 Features of the original implant abutment interface that contribute to long lasting therapeutic success. Features Benefits 1 Conical screw head No peak stresses 2 Radial contact surfaces Precise guidance 3 Tight conical implant-abutment interface Sealed connection 4 Deep implant-abutment engagement High stability

REFERENCES Kano SC, Binon P, Bonfante G, Curtis DA. Effect of casting procedures on screw loosening in UC- LA-type abutments. J Prosthodont. 2006 Mar-Apr;15(2):77-81. Kim SK, Koak JY, Heo JS, Taylor TD, Ryoo S, Lee SY: Screw loosening with interchangeable abutments in internally connected implants after cycling loading. Int J Oral Maxillofac Implants 2012; 27:42-47 Gigandet M, Bigolin G, Faoro F, Bürgin W, Brägger U. Implants with Original and Non-original Abutment Connections. Clin Implant Dent Relat Res. 2014 Apr;16(2):303-11 Keilig L, Berg J, Söhnchen P, Kocherovskaya, Bourauel C. Micro-mobility of the implant/abutment interface for original and third-party abutments a combined experimental and numerical study (Poster presented at the EAO 2013, Dublin, submitted) Wittneben JG, Buser D, Salvi GE, Bürgin W: Complication and failure rates with implant-supported fixed dental prostheses and single crowns: A 10 y retrospective study. Clin Implant Dent Relat Res. 2014 Jun;16(3):356-64. Fischer K, Stenberg T.: Prospective 10-year cohort study based on a randomized, controlled trial (RCT) on implant-supported full-arch maxillary prostheses. part II: prosthetic outcomes and maintenance. Clin Implant Dent Relat Res. 2013, Aug;15(4):498-508. Chappuis V, Buser R, Brägger U, Bornstein MM, Salvi GE, Buser D.: Long-term outcomes of dental implants with a titanium plasma-sprayed surface: a 20-year prospective case series study in partially edentulous patients. Clin Implant Dent Relat Res. 2013 Dec;15(6):780-90. Mattheos N, Janda MS. Exotic encounters with dental implants: managing complications with unidentified systems Aust Dent J. 2012 Jun;57(2):236-42. Mattheos N, Li X, Zampelis A, Ma L, Janda M. Investigating the micromorphological differences of the implant-abutment junction and their clinical implications: a pilot study. Clin Oral Implants Res. 2015 Mar 9. International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 www.straumann.com Institut Straumann AG, 2017. All rights reserved. Straumann and/or other trademarks and logos from Straumann mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. 490.258/en/B/00 01/17