PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES

Similar documents
MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

RP-HPLC method development and validation of Rilpivirine

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

Pelagia Research Library

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

A Validated Stability Indicating RP-HPLC Method for Simultaneous Estimation of Valsartan and Clinidipine Combined Tablet dosage forms

Validated RP- HPLC Method for the Quantitative Estimation of Valsartan in Bulk and Pharmaceutical Dosage Forms

World Journal of Pharmaceutical Research

UV-Spectrophotometric methods for estimation of Valsartan in bulk and tablet dosage form

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR CILOSTAZOL IN TABLET DOSAGE FORM

Scholars Research Library

Development of a Validated RP-HPLC Method for the Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Journal of Chemical and Pharmaceutical Research

vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15

Pelagia Research Library

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

ISSN (Print)

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

J Pharm Sci Bioscientific Res (4): ISSN NO

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

Research and Reviews: Journal of Pharmaceutical Analysis

International Journal of Pharmacy and Pharmaceutical Sciences. Research Article

Development and Validation of Stability Indicating HPLC method for Determination of Eperisone HCL in Bulk and in Formulation

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR THE ESTIMATION OF VALSARTAN IN PURE AND TABLET DOSAGE FORM BY RP-HPLC METHOD

AMERICAN JOURNAL OF BIOLOGICAL AND PHARMACEUTICAL RESEARCH

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

Development and Validation of Stability Indicating HPTLC Method for Estimation of Seratrodast

HPLC-UV Determination of Abacavir Sulphate in Pharmaceutical Dosage Forms

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Rao and Gowrisankar: Stability-indicating RP-HPLC Method for Pseudoephedrine, Ambroxol and Desloratadine

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

Simple and stability indicating RP-HPLC assay method development and validation lisinopril dihydrate by RP-HPLC in bulk and dosage form

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Available online Research Article

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

Abstract. G. D. Patil 1, P. G. Yeole 1, Manisha Puranik 1 and S. J. Wadher 1 *

STABILITY INDICATING HPLC METHOD FOR DETERMINATION OF RIMONABANT

International Journal of Pharma and Bio Sciences

A stability indicating RP-HPLC method for simultaneous estimation of darunavir and cobicistat in bulk and tablet dosage form

Journal of Chemical and Pharmaceutical Research

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

1. DRUG PROFILE. management of hypertension. It may also be used in patients with heart failure who are

Pelagia Research Library. Spectrophotometric method for simultaneous estimation of Valsartan and Hydrochlorothiazide in combined tablet dosage form

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Int. J. Pharm. Sci. Rev. Res., 30(1), January February 2015; Article No. 32, Pages:

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES

Validated UV Spectrophotometric Method Development And Stability Studies Of Acamprosate Calcium In Bulk And Tablet Dosage Form

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

International Journal of Farmacia

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (

International Journal of Drug Research and Technology

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

Corresponding Author:

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

Stress Degradation Studies And Validation Method For Quantification Of Aprepitent In Formulations By Using RP-HPLC

A New RP-HPLC Method Development and Validation for Simultaneous estimation of Telmisartan and Pioglitazone in Pharmaceutical Dosage Form

INTRODUCTION. safety and efficacy throughout all phases of its shelf life, including storage. In

Asian Journal of Research in Chemistry and Pharmaceutical Sciences

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

Method Validation for Simultaneous Estimation of Prednisolone and Abiraterone Acetate by RP-HPLC

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Available online Research Article

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Introductionn Ilaprazole (ILA) is

Journal of Chemical and Pharmaceutical Research, 2018, 10(3): Research Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM

Pelagia Research Library

Available online at Scholars Research Library

RP-HPLC Method for the Simultaneous Estimation of Sitagliptin Phosphate and Metformin Hydrochloride in Combined Tablet Dosage Forms

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ASSAY AND DISSOLUTION OF METOPROLOL SUCCINATE EXTENDED RELEASE TABLETS

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Accelerated Stability Studies on Valacyclovir Hydrochloride by RP-HPLC

Development of RP-HPLC Method for Estimation of Valsartan and Hydrochlorothiazide in Tablets

Method Development And Validation Of Losartan Potassium And Hydrochlorothiazide In Comined Dosage Form By RP-HPLC

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF DEXAMETHASONE AND GRANISETRON IN COMBINED DOSAGE FORMS

International Journal of Applied Pharmaceutical Sciences and Research

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

UV SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF ATENOLOL AND LOSARTAN POTASSIUM BY Q-ANALYSIS


Transcription:

PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES A NEW RP-HPLC METHOD FOR THE DETERMINATION OF VALSARTAN IN BULK AND ITS PHARMACEUTICAL FORMULATIONS WITH IT S STABILITY INDICATIVE STUDIES Arabinda Patnaik* 1, Malikarjuna Shetty 1, Subash Sahoo 1, Diptish Kumar Nayak 2, S.K Veliyath 3 1 Saraswati College of Pharmaceutical sciences, Yethbarpally, Hyderabad 2 Lachoo Memorial College of Science and Technology, Pharmacy Wing, Jodhpur. 3 Moonray Institute Of Pharmaceutical Sciences, Shadanagar, Hyderabad ABSTRACT A simple, precise, accurate, economical and reproducible HPLC method for estimation of Valsartan in tablet dosage form has been developed. Quantitative HPLC was performed with SHIMADZU LC2010c HT with class-10vp Software with UV-Visible Detector (SPD-IOA), PDA Detector (PDA-10A) PUMP (LC-IOAT) and (LC-IOATvp). Microbondapak, C 18, 5 m, 25cmx4.6mm i.d column was used in the study. The mobile phase of Methanol: phosphate buffer of ph3 (65:35) were used in this study. The conditions optimized were: flow rate (1 ml/minute), wavelength (210 nm) and run time was 20 min. Retention time was found to be 6.22 min. The linearity was found to be in the concentration range of 10-100 g/ml. The developed method was evaluated in the assay of commercially available tablets, Valzar and Valtan tablet containing 40 and 80 mg of Valsartan respectively. The amount of drug in tablet was found to be 40.35 and 79.34 mg/tab for the two brand. Results of analysis were validated statistically and by recovery studies. The recovery studies 99.35 % was indicative of the accuracy of proposed method. The precision was calculated as repeatability, inter and intraday variation (%RSD) for the drug. By using the method, stability of the drug has been studied. Key words: Valsartan, RP-HPLC, PDA Detector, Assay INTRODUCTION It is necessary to find the content of each drug either in bulk or single or combined dosage forms for purity testing. It is also essential to know the concentration of the drug and it s metabolites in biological fluids after taking the dosage form for treatment. www.pharmasm.com IC VALUE 4.01 43

The scope of developing and validating an analytical method is to ensure a suitable method for a particular analyte more specific, accurate and precise [1]. The main objective for that is to improve the conditions and parameters, which should be followed in the development and validation. According to the literature survey [2-5] it was found that few analytical methods such as (RP-HPLC [5], HPLC [6], UV-Visible analysis [3,7] and LC-MS [4] ) were reported for the estimation of Valsartan. The objective of the proposed method is to develop simple and accurate methods for the determination of Valsartan by RP-HPLC [5] method in pharmaceutical dosage forms & it s stability indicative studies. Valsartan is chemically, N-(1-oxopentyl)-N-{[2 -(1H-tetrazol-5-yl)[1,1 - biphenyl]-4-yl]methyl}-l-valine [8] is a antihypertensive drug [9], which is non-peptide potent highly selective, orally active [10]. It is also used in Congestive Heart failure (CHF), & Post Myocardial Infarction (MI). It acts as antagonist at the angiotensin II AT 1 - receptors [11]. MATERIALS AND METHOD Instruments and Reagents The chromatographic separation was performed on SCHIMADZU LC2010c HT (Autosampler) with Winchrom Software with Isocratic--Gradient with UV-Visible Detector (SPD-IOA), PDA Detector (PDA-10A), PUMP (LC-IOAT). Phenomenex ODS (C 18 ) RP Column, 250 mm x 4.6 mm has been used as a stationary phase. P H Analyzer (ELICO), Electronic Balance (AFCOSET), Ultra Sonicator (ENERTECH) has been used in the work. Valsartan Active Pharmaceutical Ingredient (API) & marketed product under brand name Valtan-80 was collected from Cipla pharmaceutical ltd. & Valzar-40 Torrent pharmaceutical limited. Methanol & water of HPLC grade were taken from Standard reagents, Hyderabad. Ammonium dihydrogen phosphate from S.D Fine chemicals, Mumbai. Another commercial formulation of valzar-40 Torrent pharmaceutical limited. Optimised Chromatographic conditions The mobile phase of Methanol: potassium dihydrogen phosphate buffer (0.1M, ph 3.0) (65:35) were used in this study. The conditions optimized were: flow rate (1 ml/minute), wavelength (210 nm, selected after using PDA detector), injection volume 20 www.pharmasm.com IC VALUE 4.01 44

μl and run time was 20 min. Retention time was found to be 6.22 min. Microbondapak, C 18, 5 m, 25cmx4.6mm i.d column was used in the study. Preparation of Standard Drug Solutions Standard stock solution of a concentration of 100 μg/ml of Valsartan was prepared by using methanol. Preparation of mobile phase The mobile phase used in this analysis consists of a mixture of Buffer (ammonium dihydrogen phosphate, 0.1M) and methanol in a ratio of 35:65 ph of the solution adjusted to 3.0 A typical chromatogram obtained by using the optimal chromatographic conditions as shown below. Figure 1 HPLC spectrum of Valsartan (100 ppm) in optimized conditions (RT 6.22 min.) Preparation of Calibration Curves Calibration curve was prepared by taking appropriate aliquots of standard valsartan stock solution in different 10 ml volumetric flask and diluted up to the mark with methanol to obtain the final concentrations of 10, 20, 30, 40, 50, 60, 70,80, 90, 100 μg/ml of valsartan. The calibration curve has been shown below. Standard solutions (n=6) were injected, the sample volume was 20 μl with a flow rate of 1.0 ml/min. www.pharmasm.com IC VALUE 4.01 45

Figure 2 Calibration curve of.valsartan Table 1: Results for construct the calibration curve CONC.(µg/ml) MEAN AUC (n=6) 10 814419 20 1484959 30 2400297 40 3333914 50 4191306 60 5000594 70 5734003 80 6669431 90 7400941 100 8334291 Degradation/ Stability studies This is one type of accelerated stability studies that helps us determining the fate of the drug that is likely to happen after a long time storage, within a very short time as compare to the real time or long term stability testing. The various degradation pathways studied are acid hydrolysis, basic hydrolysis, thermal degradation and oxidative degradation 1. Acid hydrolysis: www.pharmasm.com IC VALUE 4.01 46

An accurately weighed 10 mg. of pure drug was transferred to a clean & dry 10 ml volumetric flask. To which 0.1 M Hydrochloric acid was added & make up to the mark & kept for 24 hrs. from that 1 ml was taken in to a 10 ml volumetric flask & make up to the mark with methanol, than injected into the HPLC system against a blank of HCl & methanol ( after all optimized conditions ) Figure 3 Chromatogram showing degradation in 0.1 M HCl 2. Basic hydrolysis An accurately weighed 10 mg. of pure drug was transferred to a clean & dry 10 ml volumetric flask. To which 0.1 M Sodium hydroxide was added & make up to the mark & kept for 24 hrs. from that 1 ml was taken in to a 10 ml volumetric flask & make up to the mark with methanol, than injected into the HPLC system against a blank of. NaOH and methanol ( after all optimized conditions ) Figure 4 Chromatogram showing degradation in 0.1 M NaOH www.pharmasm.com IC VALUE 4.01 47

3. Oxidation with (3%) H 2 O 2 : An accurately weighed 10 mg. of pure drug was transferred to a clean & dry 10 ml volumetric flask. To which 3% Hydrogen Peroxide was added, make up to the mark & kept for 24 hrs. from that 1 ml was taken in to a 10 ml volumetric flask & make up to the mark with methanol, than injected into the HPLC system against a blank of. H 2 O 2 and methanol ( after all optimized conditions ) Figure 5 Chromatogram showing degradation in 3% H 2 O 2 4. Thermal degradation An accurately weighed 10 mg. of pure drug was transferred to a clean & dry 100 ml volumetric flask, make up to the mark with methanol & was maintained at 50 0 C. for 24 hrs. than injected into the HPLC system against a blank of methanol ( after all optimized conditions ) Figure 6 Chromatogram showing thermal degradation 5. Photolytic Degradation: Approximately 10 mg. of pure drug was taken in a clean & dry Petridis. It was kept in a UV cabinet at 254 nm wavelength for 24 hours without interruption. Accurately www.pharmasm.com IC VALUE 4.01 48

weighed 1 mg. of the UV exposed drug was transferred to a clean & dry 10 ml. volumetric flask. First the UV exposed drug was dissolved in methanol & make up to the mark. than injected into the HPLC system against a blank of methanol ( after all optimized conditions ) Figure 7 Chromatogram showing photolytic degradation RESULTS & DISCUSSION Results of degradation studies: The results of the stress studies indicated the specificity of the method that has been developed. Valsartan was degraded only in 3% H 2 O 2 & temperature stress conditions. The result of forced degradation studies are given in the following table. Table 2: Results of force degradation studies of Valsartan API. Stress condition Time Assay of active substance Assay of degraded products Mass Balance (%) Acid Hydrolysis (0.1 M HCl) 24Hrs. 98.36 ----------- 98.36 Basic Hydrolysis (0.I 24Hrs. 98.32 ----------- 98.32 M NaOH) Oxidation(3% H 2 O 2 ) 24Hrs. 77.15 22.05 99.20 Thermal Degradation 24Hrs. 81.36 16.93 98.29 (50 0 C) UV (254nm) 24Hrs. 98.79 ---------- 98.78 www.pharmasm.com IC VALUE 4.01 49

Method validation Accuracy : Recovery study: To determine the accuracy of the proposed method, recovery studies were carried out by adding different amounts (80%, 100%, and 120%) of pure drug of valsartan were taken and added to the pre-analyzed formulation of concentration 10 g/ml. From that percentage recovery values were calculated. Precision : Repeatability The precision of each method was ascertained separately from the peak areas & retention times obtained by actual determination of five replicates of a fixed amount of drug. Valsartan (API) The percent relative standard deviation were calculated for valsartan Intra-assay & inter-assay: The intra & inter day variation of the method was carried out & the high values of mean assay & low values of standard deviation & % RSD (% RSD < 2%) within a day & day to day variations for valsartan revealed that the proposed method is precise Linearity & Range : The calibration curve showed good linearity in the range of 10 100 µg/ml, for valsartan (API) with correlation coefficient (r 2 ) of 0.999 (Fig. 02). A typical calibration curve has the regression equation of y = 83907x - 78449 for valsartan. Method Robustness: Influence of small changes in chromatographic conditions such as change in flow rate ( 0.1ml/min), Temperature ( 2 0 C), Wavelength of detection ( 2nm) & methanol content in mobile phase ( 2%) studied to determine the robustness of the method are also in favour of (Table-4, % RSD < 2%) the developed RP-HPLC method for the analysis of valsartan ( API). LOD & LOQ: The Minimum concentration level at which the analyte can be reliable detected (LOD) & quantified (LOQ) were found to be 0.02 & 0.06 µg/ml respectively. Specificity & stability in analytical solution: www.pharmasm.com IC VALUE 4.01 50

The results of specificity indicated that the peak was pure in presence of degraded sample. It is important to mention here that the valsartan (API) was stable in solution form up to 24 hrs at 25 0 C. The results of linearity, precision, inter & intraday assays, method robustness, LOD, LOQ, specificity and stability in analytical solution established the validation of the developed RP-HPLC method for analysis of valsartan. Table 3: Summary of validation parameters by rp-hplc method Validation parameters VALSARTAN Specificity % interference <0.5 % Range (µg/ml) Linear range 10-100 μg/ml Working range 0.02-100 μg/ml Target range 44,55,60.5 μg/ml Target concentration 55 μg/ml Accuracy (% Recovery) 80, 100, 120 98.94667, 99.76, 99.37667 Precision (% RSD) Repeatability 0.134 Intra day 0.86 Inter day 0.87 LOD (µg/ml) 0.02 LOQ (µg/ml) 0.06 ASSAY OF VALSARTAN IN DOSAGE FORM: Assay was performed as described in previous chapter. Results obtained are tabulated below: Table 4: Assay of Valsartan tablets Brand name of tablets Labeled amount of Drug (mg) Mean ( SD) amount (mg) found by the proposed Mean ( SD) Assay (n = 6) method (n=6) Valzar 40 40.35 ( 0.06) 100.88 ( 0.48) Valtan 80 79.34 ( 0.04) 99.18 ( 0.04) www.pharmasm.com IC VALUE 4.01 51

The assay of valzar and valtan tablets containing valsartan was found to be 100.88 % and 98.18 % as per the method. CONCLUSION The proposed method is simple, sensitive and reproducible and hence can be used in routine for determination valsartan in bulk as well as in pharmaceutical preparations. Statistical analysis of the results has been carried out revealing high accuracy and good precision. REFERENCES 1. Rockville M D, United States Pharmacopoeia; United States Pharmacopoeial Convention Inc, 25th Edn., 2002 ; 1 : 2150. 2. María del Rosario Brunetto, Yaritza Contreras, Sabrina Clavijo, Dina Torres, Yelitza Delgado, Fernando Ovalles, Carlos Ayala, Máximo Gallignani, José Manuel Estela and Víctor Cerdà Martin: Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection. Journal of pharmaceutical and biomedical analysis. 2009 ; 1 : 1873-1876 3. Zong-Zhu Piao, Eung-Seok Lee, Huyen Thi Thanh Tran and Beom-Jin Lee: Improved analytical validation & pharmacokinetics of valsartan using HPLC & UV detection. Arch Pharm 2008 ; 1 : 1055-1059, 4. Koseki Nozomu, Kawashita Hiroto, Hara Hisanori, Niina Miyuki, Tanaka Makoto, Kawai Ryosei, Nagae Yusuke, Masuda Naoki: A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of valsartan in human plasma. Journal of Pharmaceutical and Biomedical Analysis. 2007 ; 1 : 1769-1774 5. DF Tian, XL Tian, T Tian, ZY Wang, FK Mo: Simultaneous determination of valsartan and hydrochlorothiazide in tablets by RP-HPLC. Indian Journal of Pharmaceutical Sciences 2008 ; 1 : 372-374 6. Koçyiğit-Kaymakçoğlu B, Unsalan S and Rollas S: Determination and validation Ketoprofen, Pantoprazole and Valsartan together in human plasma by hig performance liquid chromatography. Pharmazie.2006; 61: 586-589. www.pharmasm.com IC VALUE 4.01 52

7. Tatar S and Sağlík S: Comparison of UV- and second derivativespectrophotometric and LC methods for the determination of Valsartan in pharmaceutical formulation. J Pharm Biomed Anal. 2002; 30: 371-375. 8. Budavri S, The Merck Index; 12th Edn; Merk & Co, Inc., Whitehouse Station, NJ,1996, 1691 9. Crisscione L, Gasparo M D, Buhlamayer P, Whitebread S, Ramjoune and Wood J: Br J Pharmacol., 1993, 110, 761-771. 10. Criscione L, Bradlely W A, Buhlmayer P, Whitebread S, Glazer R P, Lloyd P, Mueller M and Gasparo M D: Comparison of Valsartan With Candesartan on Their Possible Protection From Atherosclerosis J Clin Basic Cardiol 2001; 4: 297 11. Thurmann P V: Expert Opin Pharmacother., 2000, 1, 337-350 For Correspondence: Arabinda Patnaik, s/o- Prasanna Kumar Patnaik, Laxmi Nivas, Godabarisha Nagar Main Lane, Berahampur, Ganjam, Orissa, Pin-760001 Phone No.: +91-901430214 Email: aravindapatnaik@gmail.com www.pharmasm.com IC VALUE 4.01 53