EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

Similar documents
TOTAL KNEE SYSTEM WHEN INNOVATION AND INTUITION ALIGN.

Analysis of factors affecting range of motion after Total Knee Arthroplasty

INSTRUMENTS. Design Rationale

INSTRUMENTS. Product Rationale

Distal Cut First Femoral Preparation

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

Total Knee Original System Primary Surgical Technique

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

OrthoMap Express Knee Product Guide. OrthoMap Express Knee Navigation Software 2.0

itotal Customized POSTERIOR-STABILIZED knee replacement system

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

Stefan Rahm MD University Hospital Balgrist

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

ANTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Anterior Reference Surgical Technique

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Extramedullary Tibial Preparation

Intramedullary Tibial Preparation

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

POSTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Posterior Reference Surgical Technique

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

KneeAlign System Surgical Technique Guide

TOTAL KNEE ARTHROPLASTY (TKA)

Rotaglide+ TM. Total Knee System Product overview

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

Presented By Dr Vincent VG An MD BSc (Adv) MPhil Dr Murilo Leie MD Mr Joshua Twiggs BEng Dr Brett A Fritsch MBBS FRACS (Orth) FAOrthA.

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases

COMPUTER ASSISTED ROBOTIC TOTAL KNEE ARTHROPLASTY

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

Computer Navigation in TKA The role of Robotic Surgery. Christos Yiannakopoulos, M.D., Ph.D.

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

Single Axis Revision Knee System

Operative Technique. Constrained Condylar. The Right Track It s not just a road we re on, it s a trail we re blazing.

LAMINA SPREADER SURGICAL TECHNIQUE

The PinTrace system. medical robotics

Dora Street, Hurstville 160 Belmore Road, Randwick

Zimmer Segmental System

With over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world.

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

Aesculap Orthopaedics Columbus MIOS

Personalized Solutions. Portfolio Brochure

Knee Revision. Portfolio

OPERATIVE TECHNIQUE SKS Total Knee Replacement

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

Masterclass. Tips and tricks for a successful outcome. E. Verhaven, M. Thaeter. September 15th, 2012, Brussels

Bone Preservation Stem

15-Year Follow-up Study of Total Knee Arthroplasty in Patients With Rheumatoid Arthritis

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

Technique Manual Technique Manual Rev. A 01/11/2011

SURGICAL TECHNIQUE VISUALIZE FEMORAL FIXATION 360 GRAFT TO BONE CONTACT INCREASED PULL-OUT STRENGTH

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

Corporate Medical Policy

Resurfacing Distal Femur. Orthopaedic Salvage System

Simplifying the Most Clinically Proven 1 Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation

OPERATING MANUAL AND TECHNIQUE GUIDE FOR TITANIUM FEMORAL AND TIBIAL NAILING SYSTEMS

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013

Knee Replacement Implants

Patient Specific Instruments. Surgical Technique

Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

NexGen Complete Knee Solution. Cruciate Retaining (CR) and Revision Instrumentation Surgical Technique for Cruciate Retaining Augmentable (CRA) Knees

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

PINTRACE method. Navigation with or without robot assistance. The PinTrace method is based entirely on robotassisted

Robotic Surgery. What Robotic Surgery Isn't!

DOWNLOAD OR READ : TECHNIQUES IN REVISION HIP AND KNEE ARTHROPLASTY PDF EBOOK EPUB MOBI

CS 3600 / CS 3600 ACCESS A SMARTER WAY TO SCAN INTRAORAL SCANNING

Mako. Total Knee with Triathlon. Surgical protocol

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

Proven Gen-Flex Revision Knee System. Surgical Protocol

Abramsohn Retractor 1

TOTAL KNEE ARTHROPLASTY SYSTEM

Mako Partial Knee Patellofemoral

BIOTECH FUTURE KNEE Minimal Invasive (and classic) Surgical Technique

Total Knee Replacement: 12 Years Retrospective Review and Experience

Complications of Total Knee Arthroplasty

TRK REVISION KNEE Surgical Technique

Quadriceps sparing total knee replacement

The power of simplicity

Zimmer Gender Solutions Natural-Knee Flex System

Transtibial PCL Reconstruction. Surgical Technique. Transtibial PCL Reconstruction

Zimmer NexGen Rotating Hinge Knee Primary/ Revision

Mr Aslam Mohammed FRCS, FRCS (Orth) Consultant Orthopaedic Surgeon Specialising in Lower Limb Arthroplasty and Sports Injury

The prosthetic implant of MBA Optetrak in the treatment of knee osteoarthritis: 5 years of experience

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

Resurfacing Patellar Preparation

Biomechanical Effects of Femoral Component Axial Rotation in Total Knee Arthroplasty (TKA)

BRAINLAB ORTHOPEDICS SOFTWARE SOLUTIONS TO IMPROVE PATIENT CARE

PROPHECY INBONE. Preoperative Navigation Guides

Patient-specific bicompart mental knee resurfacing system

Surgical Technique Final Trial Reduction and Component Implantation of

Think isometry Feel balance

Transcription:

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

The year 2010 marked Exactech s silver aiversary and 25 years of mobility. As a company founded by an orthopaedic surgeon and a biomedical engineer, Exactech has a unique perspective on product development. Our orthopaedic implants, surgical instrumentation and biologic solutions are designed with a primary goal of improving patient outcomes. Exactech GPS is a user-friendly new technology that is redefining the way orthopaedic surgery is plaed and performed. This non-intrusive, computer-based system is designed to provide fast, accurate, visual displays within the sterile field while taking up minimal space in the operating room. The touch screen puts anatomical landmark verification within arm s reach. Personalized for surgeon preferences and patient indications, Exactech GPS can guide the entire O.R. staff through each case, improving workflow and supporting bone reconstruction and soft tissue balancing objectives. Exactech GPS guided, personalized surgery is designed to be a powerful addition to your surgical team that supports your goal of achieving accuracy and reproducibility in total joint arthroplasty. Although computer assisted surgery, mechanical instrumentation and other surgical technologies have increased accuracy and reliability in total knee arthroplasty, alignment and rotational outliers continue to occur. No one system has addressed the parameters of affordability, optimization of O.R. time, ease of use, accuracy and intra-operative adjustability to be truly successful by industry standards until now. GPS Navigation Custom Cutting Blocks Robotics Ease of Use Affordability O.R. Efficiency Intra-operative Adjustability Soft Tissue Management Accuracy 1

Exactech GPS is the ultimate addition to your surgical team. Ergonomically designed for ease of use, the system requires minimal assembly. Similar to a GPS touch screen in a car, data is presented in a clear way, guiding your entire surgical team throughout each individual case. From simplified and faster surgical protocols to improved workflow and flexibility, Exactech GPS fully integrates into your operating room, blending into the surgical environment. Pre-established, customizable surgical protocols are designed to save time and increase efficiency, guiding your team throughout each case and allowing you to focus on the patient. Unlike other systems, Exactech GPS provides you with real-time virtual vision and anatomical landmark verification all within arm s reach in the sterile field. Get There Faster. Less complex system than conventional navigation Simplified, faster surgical protocols Reduced number of traditional instruments Non-intrusive integration into your operating room Exactech GPS is designed to become a dependable member of your surgical team with its precise guidance through your total joint arthroplasty surgeries. Not only is the screen easy to read for your entire team, but the data presentation, including mechanical axis values and resection levels, can be preplaed to your preferred sequence, landmarks and references. 2 3

You decide the approach. GPS helps you get there. Exactech GPS is personalized for surgeon preferences and patient indications, providing the ultimate flexibility that can adapt to any surgical scenario. The state-of-the-art technology supports a comprehensive array of soft tissue strategies and allows you to customize and pre-plan surgeries that fit your surgical philosophy. With Exactech GPS, you can easily adjust intra-operatively, balance flexion and extension gaps and plan component placement before performing resections. Exactech GPS eliminates the need for costly pre-operative diagnostic imaging. Simplified intra-operative adjustability Easy determination of flexion and extension gaps Soft tissue management compatibility Component up- and down-sizing Maintain Total Control. The Surgeon Profiler can be fully customized, simplifying and optimizing each surgical step. Preferences such as surgical sequence, implant style, soft tissue balancing methods and pre- and post-operative kinematics are streamlined with the Surgeon Profiler technology. And to ensure the ultimate ease of use, your Exactech GPS-certified representative will be able to assist you every step of the way. 4 5

You know your surgery. GPS will help streamline your protocols. Exactech GPS provides accurate, real-time feedback of anatomical and mechanical alignment landmarks throughout surgery. Based on your surgical preferences, anatomical landmark registration is performed intra-operatively with clear, automated data displayed within seconds. Whether you are performing a cruciate retaining or posterior stabilized knee, Exactech GPS supports your surgical preferences with bone reconstruction and soft tissue balancing objectives, including defined component sizing, and rotational and mechanical alignment. Real-time feedback of anatomical and mechanical landmarks Intra-operative registration based on your preference Supports precise component sizing and rotation Enjoy Precision Handling. Exactech GPS uses a contemporary infrared camera and active tracker technology that features simplified data presentation in a close operating distance within the sterile field. Reference points on both the distal femur and proximal tibia are pre-established on the Surgeon Profiler with your Exactech GPS representative, enabling you to select only the reference points that align with your surgical preferences. 6 7

With decades of clinical success and proven outcomes for patients around the world, Exactech offers a full line of Optetrak implants and streamlined instrumentation that address your concerns for contact stress, patellar tracking, polyethylene wear, joint stability and bone preservation in total knee arthroplasty. All from a company that is focused on improving the quality of life for individuals by maintaining their activity and independence. The Exactech GPS system, combined with the clinically proven Optetrak knee, addresses the latest emerging trends in total knee arthroplasty. With proven long-term patient outcomes and 91-99 percent survival rates, 1-11 the Optetrak knee has been evolving and improving since its foundation that started more than 30 years ago. The total knee design was developed at the Hospital for Special Surgery in New York based on the solid foundation of the Total Condylar, Insall/Burstein and Insall/Burstein II. Combined with Exactech GPS unique technology, the system is designed for optimal and consistent results for your total knee surgeries. Experience Custom Fit. You determine the best course for your patients. GPS can help provide a custom-fit knee with less pain, faster recovery and a less invasive approach. Optetrak CR Slope Optetrak Logic PS 8 9

A B A B Display Unit Ergonomically designed, easy-to-read touch screen within arm s reach in the operative field Surgeon Profiler Customizable software can be pre-plaed according to surgeon preference and patient indications D C E C D Control Unit Computer system features a unique anatomical landmark registration technology that is designed for accuracy at short distances Pointer Tracker Active tracker allows the surgeon to move through the software with its forward and backward button E Active Tracker Technology Active trackers provide real-time anatomical registration displayed on the touch screen Exactech GPS Instrumentation 521-10-00 External Tracker Fixator with 0-degree Attachment 521-10-30 External Tracker Fixator with 30-degree Attachment 521-10-45 External Tracker Fixator with 45-degree Attachment 521-40-05 Femoral GPS Base Positioning Template LEM (Lateral Extra-Medullary) 521-11-04 3.5 mm Hexagonal Screwdriver 521-30-01 Exactech GPS Tibial Block Base, Left 521-30-02 Exactech GPS Tibial Block Base, Right 521-40-01 Exactech GPS Femoral Block Base, Central 521-11-00 Exactech GPS Adjustable Module 521-11-01 Exactech GPS Cutting Block 521-40-02 Exactech GPS Femoral Distal Cutting Block 521-40-03 Exactech GPS Femoral 4-in-1 Positioning Guide 521-30-03 Exactech GPS Tibial Base Positioning Template 521-30-04 Exactech GPS Tibial EM Coupler Coector, Base Positioning Template 521-40-05 Exactech GPS Femoral Base Positioning Template, Lateral EM 521-40-06 Exactech GPS Femoral IM Coupler Coector, Base Positioning Template 521-11-02 Exactech GPS Blade Drill Guide A10007 Exactech GPS Disposable Kit Box (Starter Key, Sterile Batteries, Sterile Drape) References 1. Ranawat CS, Fly WF Jr, Saddler S, Hansraj KK, Maynard MJ. Long-term results of the total condylar knee arthroplasty: A 15-year survivorship study. Clin Orthop.1993;286:94-102. 2. Gill GS, Joshi AB, Mills DM. Total condylar knee arthroplasty: 16- to 21-year results. Clin Orthop. 1999;367:210-5. 3. 3. Insall JN, Lachiewicz PF, Burstein AH. The posterior stabilized condylar prosthesis: a modification of the Total Condylar design. Two-to four-year clinical experience. J Bone Joint Surg. 1982;64-A:1317-23. 4. Stern SH, Insall JN. Posterior stabilized prosthesis: results after follow-up of nine to 12 years. J Bone Joint Surg. 1992;74-A(7): 980-6. 5. Aglietti P, Buzzi R, De Felice R, Giron F. The Insall/Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up. J Arthroplasty. 1999;14(5):560-5. 6. Scuderi GR, Insall JN, Windsor RE, Moran MC. Survivorship of cemented knee replacements. J Bone Joint Surg Br. 1989;71(5):798-803. 7. Vince KG, Insall JN, Kelly MA. The total condylar prosthesis: 10- to 12-year results of a cemented knee replacement. J Bone Joint Surg Br. 1989;71(5):793-7. 8. Font-Rodriquez DE, Scuderi GR, Insall JN. Survivorship of cemented total knee arthroplasty. Clin Orthop. 1997;(345):79-86. 9. Robinson RP. Comparison of clinical results of the third, fourth and fifth generations of the Hospital for Special Surgery prosthetic knee implant. Presented at the Pesylvania Orthopaedic Society, Fall 1999. Farmington, PA. 10. Edwards J, Gradisar I Jr, Nadaud M, Kovacik M, Askey M. Eight and one-half year clinical experience with the Optetrak total knee prosthesis. Presented at the American Academy of Orthopaedic Surgeons. February 2004. 11. Robinson RF. Five-year follow-up of primary Optetrak posterior stabilized total knee arthroplasties in osteoarthritis. J Arthroplasty. 2005 Oct;20(7):927-31. Exactech is proud to have offices and distributors around the globe. For more information about Exactech products available in your country, please visit www.exac.com. 2011 EXACTECH, INC. ISO 13485 CERTIFIED 352-377-1140 1-800-EXACTECH www.exac.com 712-26-20 GPS Brochure 0211 *+$712-26-200*