Transcutaneous Pacing on Zoll Defibrillator Version 4 Related Documents SOP-Zoll defibrillator ; Phillips MRX SOP Dr Randal McRoberts

Similar documents
Reviewed Date: Supersedes (Policy #/description & date): Prepared by: Jacque Callis, RN Approved by: D.R. Johnson, MD

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2

Figure 2. Normal ECG tracing. Table 1.

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

RN-BC, MS, CCRN, FAHA

Cardioversion / Defibrillation / Transcutaneous Pacer Helpful Hints [ZOLL] 2018

Transcutaneous Pacing. Approval: Medical Director James Stubblefield, MD. Approval: EMS Director Michael Petrie

Early Defibrillation. Dr. M. Ravishankar

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

Cardiac Pacing. Learning outcomes. Introduction. The cardiac impulse - its formation and its failure CHAPTER. To understand:

OBJECTIVE. 1. Define defibrillation. 2. Describe Need and history of defibrillation. 3. Describe the principle and mechanism of defibrillation.

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

SARASOTA MEMORIAL HOSPITAL

Model 5392 EPG Temporary Pacer

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

TIP CARD. Model Temporary External Pacemaker

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Pacemakers 12/04. Pacemakers. 1. What is a pacemaker?

Pediatric pacemakers & ICDs:

Peri-operative management of pacemakers and implantable cardiac defibrillators

Ass. Prof. Tomon Thongsri, MD Buddhachinaraj Phitsanuloke Hospital

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

1. What additional information needs to be collected to properly treat this client?

Panorama. Arrhythmia Analysis Frequently Asked Questions

Electrical Interventions

Non-Invasive Transcutaneous Pacing

Indications The AED mode is to be used only on patients in cardiopulmonary arrest.

June 2009 CE. Site code # E-1209

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Project Title Temporary Pacemaker Training Simulator

Automated External Defibrillation Principle of Early Defibrillation States that all BLS personnel be trained, equipped and allowed to operate a if

1 Cardiology Acute Care Day 22 April 2013 Arrhythmia Tutorial Course Material

1-Epinephrine 2-Atropine 3-Amiodarone 4-Lidocaine 5-Magnesium

MINI MASSAGER. Relaxation,Anywhere, Anytime

COALINGA STATE HOSPITAL. NURSING POLICY AND PROCEDURE MANUAL SECTION Emergency Procedures POLICY NUMBER: 716. Effective Date: March 3, 2007

T.E.N.S (Transcutaneous Electrical Nerve Stimulation)

Chapter 80 Implantable Cardiac Devices

NORTH OF ENGLAND CARDIOVASCULAR NETWORK (NECVN)

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

STANDARD OPERATING PROCEDURE (SOP)

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

Permanent Pacemaker Implantation Post Cardiac Surgery: A Cautionary Tale

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS

MONITORING PATIENTS WITH A TEMPORARY EXTERNAL EPICARDIAL PACEMAKER PURPOSE POLICY STATEMENTS SITE APPLICABILITY PRACTICE LEVEL/COMPETENCIES

ECG Monitoring, Defibrillation and Synchronized Cardioversion with Hands-Free Electrodes

Defibrillator. BiomedGuy

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

CORONARY ARTERIES HEART

EXTERNAL TEMPORARY PACEMAKERS

Addendum: User Guide AutoPulse Resuscitation System Model 100 with Defibrillator Interface

Defibrillators TEC-8300K series. Improving quality of resuscitation

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

Dual Chamber Temporary External Pacemaker

Subcutaneous implantable cardioverter defibrillator insertion for preventing sudden cardiac death

Mini Pulse Electronic Stimulator

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

WHY IS FIRST AID IMPORTANT?

TEMPORARY PACEMAKERS HINTS ( DUAL CHAMBER 5392 PACER)

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Electrocardiography for Healthcare Professionals

Icd 10 for pacemaker pocket infection

Emergency Department Management of Patients with Implantable Cardioverter Defibrillators

AWAY Model # RTLAGF-900 REV

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

Adult Advanced Cardiovascular Life Support 2015 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular

ICD Implantation Patient Information

QUICK SETUP GUIDE SECULIFE DFBASE

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

Perioperative Management of Cardiac Implantable Devices

Cardiac Resynchronisation Therapy Patient Information

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Pediatric Cardiac Arrest General

Pacing Lead Implant Testing. Document Identifier

New and Future Trends in EMS. Ron Brown, MD, FACEP Paramedic Lecture Series 2018

7 Cedar Street, Suite 202 Sudbury, ON P3E 1A

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Supplemental Material

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

Improving quality of resuscitation. Defibrillators TEC-5600 series

SIX PACK ABS Item No INSTRUCTION MANUAL. Read entire manual before operating this product. Use only as directed.

BEDSIDE ECG INTERPRETATION

Arrhythmias. Pulmonary Artery

INTERNAL CARDIOVERSION. Lancashire & South Cumbria Cardiac Network

1. Normal sinus rhythm 2. SINUS BRADYCARDIA

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

Pacing Codes and Modes Concepts

Kadlec Regional Medical Center Cardiac Electrophysiology

Revised 3/3/2008 References provided on last slide

TASER and In-Custody Deaths

Finally, a pacemaker may be either permanent or temporary, which will also factor into your code selections.

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Temporary Pacemakers

Transcription:

Emergency Medical Retrieval Service (EMRS) www.emrs.scot.nhs.uk Standard Operating Procedure Public Distribution Title Transcutaneous Pacing on Zoll Defibrillator Version 4 Related Documents SOP-Zoll defibrillator ; Phillips MRX SOP Author Dr Randal McRoberts Reviewer Dr Stephen Hearns THE PHILLIPS MRX DEVICE (DEFAULT MONITOR FOR EMRS) HAS A SEPARATE SOP WHICH INCLUDES A PACING SECTION. THIS SOP PURELY REFERS TO THE ZOLL DEVICE. Aims This document discusses the transcutaneous pacing facilities using the Zoll defibrillator currently in use with EMRS Background Patients in complete heart block may require temporary pacing transcutaneously prior to undergoing formal permanent pacemaker (PPM) insertion at a definitive care centre. Unless a functional transvenous pacing wire has been inserted at the referring site, the patient may require transcutaneous pacing (TCP) by EMRS during transport to definitive care. The E series Zoll (manual) defibrillator/pacing devices currently used as a backup monitor by EMRS have been cleared for use on Military aircraft and SAS-A & SAS-B helicopters. Application EMRS Team Members SAS Paramedics SOP- Transcutaneous Pacing 1

Patients appropriate for retrieval team activation Patients in complete heart block or those patients whose bradycardia demands measures beyond that of drug intervention to achieve adequate cardiac output. Advice to GP/Hospital referrer prior to team arrival: Arrange for transvenous pacing if equipment & expertise available Support heart rate and blood pressure according to the current ALS algorithm for bradycardia Continuous ECG/SpO2/Heart Rate/BP monitoring 12 lead ECG & repeat at 30min intervals Consider brady-arrhythmia may be part of ACS and treat accordingly Look for electrolyte abnormalities and treat accordingly If transcutaneous pacing is available and is required, institute its use with sedation for patient comfort as required Medical management on scene The patient should be fully assessed on arrival. The treatment instituted to this point by the referring centre should be noted. 1. Resuscitate as necessary according to ALS guidelines 2. If the patient has had transvenous or transcutaneous pacing, the following should be checked: The effectiveness of this intervention i.e. that the pacing is achieving both electrical and mechanical capture and that the patient s clinical condition reflects this 12 lead ECG Any bloods/investigations if done already (eg: Troponin; U&E) If transvenous: The position of the pacing wire on the CXR. Ensure no immediate complication of the procedure (eg: Pneumothorax) If transcutaneous: The condition/length of use of the pads (replace if have been used for 8hours of continuous pacing) Position of pads Front & back positioning of pads is optimal for pacing Patient comfort check for need for sedation/analgesia to achieve effective pacing SOP- Transcutaneous Pacing 2

Having decided clinically on the need for transcutaneous pacing, the following steps should be taken when setting up the Zoll E series defibrillator/pacer device: a) Dry and prepare patient s chest for application of Stat-Padz AND 3 (or 5) Lead ECG. Both are needed to pace in either Demand or Standby mode. On the rare occasion that asynchronous pacing is used, the ECG will not be applied. b) Explain to the patient that it feels uncomfortable during the pacing period c) Check stat padz multi-function electrodes (MFE) expiry date d) Connect the MFE cable to the Zoll device multi-function cable (white opaque connector on MFE to red connector on Zoll) e) Apply the MFE to the patient as per the instructions on the packaging. The pads should be placed in the anterior-posterior orientation for pacing. If AP positioning not possible then consider apex-sternum positioning (less effective for pacing). Ensure adhesion to skin. f) If the MFE pads are not making good contact with the patient, the messages CHECK PADS and POOR PAD CONTACT are alternately displayed and the energy will not be delivered. g) If a short circuit exists between the MFE pads, the message DEFIB PAD SHORT is displayed. h) The following steps can be applied to optimise the set-up of the device for pacing: SOP- Transcutaneous Pacing 3

Step 1 The Pacer (Green) mode is accessed by turning the Selector Switch counterclockwise Milliamps (ma) are the unit of pacing energy No AED capability or ANALYZE button can be used in pacing mode Step 3 Turn the Pacer Output dial to adjust the level of discharged milliamps. If capture is achieved, the ECG will have a wide complex reflecting ventricular contraction following the thin Pacing spike marker Step 2 Pacer markers (PM) indicate the rate set to attempt to capture the ventricle. Default settings of 70 Paces Per Minute (PPM) and 0 ma are displayed upon access of Pacer Mode To increase or decrease pacer marker rate, (PM) turn the Pacer Rate Dial i) Once electrical and mechanical capture has been confirmed, dial the ma up 10% from capture threshold as a safety margin The 4:1 button may be pushed at anytime to allow for review of the underlying rhythm. The Zoll device can perform 3 different types of pacing: 1) Demand Pacing: Most frequent form of ventricular pacing. The Pacing rate is set above patient s rate (or lack thereof) and the Pacer Output dial is turned to increase the ma in attempt to obtain capture and pace the ventricles. 2) Stand-by Pacing: Setting the Pacing rate and Pacer output at a back-up rate less than a patient s intrinsic heart rate. The Pacing rate will initially be set above the patient s heart rate and pacer output (ma) is increased to achieve 100% capture. The Pacing rate is then decreased to desired rate below the patient s intrinsic heart rate. Should the HR drop, the stand-by pacer will initiate impulses and begin to pace. 3) Asynchronised Pacing: Rarely used. This form of pacing is performed when no ECG electrodes can be placed due to burns, trauma or interference. The async on/off softkey button is pressed and async mode is displayed. No Pacing spike or electrical capture will be seen on the screen. Mechanical capture will only be proven, by palpating a pulse if one is achieved SOP- Transcutaneous Pacing 4

Triage The normal referral pathways for the referring site should be followed where possible and the local cardiology unit capable of permanent pacemaker insertion should be the destination of choice. In the situation where a patient may have had an acute coronary syndrome, that patient may require PCI and as such, must be triaged to a centre capable of providing this. Bibliography 1. ALSG website algorithm for brady-arrhythmia: http://www.resus.org.uk/pages/bradalgo.pdf 2. Zoll website for instruction manual for E series: http://www.zoll.com.au/products/e_series/ SOP- Transcutaneous Pacing 5