Paravalvular leaks (PVL) are common

Similar documents
Transcatheter Closures for Fistula Tract and Paravalvular Leak after Mitral Valve Replacement and Tricuspid Annuloplasty

Successful Percutaneous Closure of Mitral Bioprosthetic Paravalvular Leak Using Figulla ASD Occluder

Transcatheter Trans-Apical Closure of Paravalvular Mitral and Aortic Leaks Using a New Device: First in Man Experience

For Personal Use. Copyright HMP 2013

Percutaneous atrial septal defect closure with the Occlutech Figulla Flex ASD Occluder.

Treatment of Inter-MitraClip Regurgitation Due to Posterior Leaflet Cleft by Use of The Amplatzer Vascular Plug II device

Atrial Septal Defect Closure. Stephen Brecker Director, Cardiac Catheterisation Labs

Para-valvular Leak Closure

TEE Essential in Paravalvular Leak Closure and Pseudoaneurysm Repair. Gerard T Wilkins

Transcatheter closure of the patent ductus arteriosus using the new Amplatzer duct occluder: Initial clinical applications in children

First Transfemoral Aortic Valve Implantation In Bulgaria - Crossing The Valve With The Device Is Not Always

Hybrid Muscular VSD Closure in Small Weight Children

Percutaneous VSD closure

JOINT MEETING 2 Tricuspid club Chairpersons: G. Athanassopoulos, A. Avgeropoulou, M. Khoury, G. Stavridis

Para-valvular Leak Closure

Bioprosthetic Mitral Valve Dysfunction: Innovation and Evolution of a New Therapeutic Technique

2 Brigham and Women s Hospital, Boston, MA.

Subacute left ventricular outflow tract obstruction after transapical closure of a mitral paravalvular leak in the region of the aortomitral curtain

TCTAP C-217 Bilateral Pulmonary Arterio Venus Fistula Managed by Vascular Plugs and Coil Manotosh Panja 1 1 BelleVue Clinic, India

PERCUTANEOUS TRANSCATHETER CLOSURE OF PARAVALVULAR LEAK

Transcatheter closure of patent foramen ovale using the internal jugular venous approach

IMAGES. in PAEDIATRIC CARDIOLOGY. Abstract

Repair or Replacement

Conflict of Interests

Διαδερμική θεραπεία των παραβαλβιδικών διαφυγών Σ.Ράμμος

Transcatheter closure of paravalvular leaks using a paravalvular leak device a prospective Polish registry

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

AMPLATZER Septal Occluder

INTEGRATING ECHOCARDIOGRAPHY WITH CATHETER INTERVENTIONS FOR CONGENITAL HEART DISEASE. Krishna Kumar SevenHills Hospital, Mumbai, India

IMAGES. in PAEDIATRIC CARDIOLOGY

Structural Heart Disease: Setting the Stage for Success

Type Size AP/PS RP/RS Qp/Qs. Ia Resistive <0.3 < Ib Resistive <0.3 < IIa Resistive <0.5 >2

(Ann Thorac Surg 2008;85:845 53)

For Personal Use. Copyright HMP 2013

Jian Fang 1, Shaobo Xie 2, Lunchao Ma 2, Chao Yang 2. Original Article

DISCLOSURE. Mitral ViV: why? Mitral Valve- in- Valve: Procedural Image Guidance with TEE, a Must Have or Nice to Have? UW Medicine NONE.

ΔΙΑΧΕΙΡΙΣΗ ΑΣΘΕΝΩΝ ΜΕ ΜΕΣΟΚΟΛΠΙΚΗ ΕΠΙΚΟΙΝΩΝΙΑ ΖΑΧΑΡΑΚΗ ΑΓΓΕΛΙΚΗ ΚΑΡΔΙΟΛΟΓΟΣ ΗΡΑΚΛΕΙΟ - ΚΡΗΤΗ

Outline 9/17/2016. Advances in Percutaneous Mitral Valve Repair and Replacement. Scope of the Problem and Guidelines

Percutaneous occluder device closure through femoral vein guidance by transthoracic echocardiography in adult atrial septal defect patients

Transesophageal Echocardiography in Children: An Interactive Session on Common Congenital Cardiac Defects

Transcatheter paravalvular leak closure and hemolysis a prospective registry

Successful Transfemoral Edwards Sapien Aortic. Valve Implantation in a Patient with Previous. Mitral Valve Replacement

Journal of the American College of Cardiology Vol. 33, No. 5, by the American College of Cardiology ISSN /99/$20.

PROSTHETIC VALVE BOARD REVIEW

TAVR: Echo Measurements Pre, Post And Intra Procedure

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

ATRIAL SEPTAL CLOSURE AND LEFT ATRIAL APPENDAGE OCCLUSION: INDICATIONS AND GUIDANCE ECHOCARDIOGRAPHY IN INTERVENTIONAL CARDIOLOGY

Atrial Septal Defects

Portico (St. Jude Medical Inc, St.

Transcatheter Aortic Valve Replacement

Surgical placement of a cardiac prosthetic valve improves

Mitral regurgitation (MR) is the second most

Transcatheter aortic valve replacement with intracardiac echocardiography from the right internal jugular vein

When Does 3D Echo Make A Difference?

Delayed Infective Endocarditis with Mycotic Aneurysm Rupture below the Mechanical Valved Conduit after the Bentall Procedure

Options for my no option Patients Treating Heart Conditions Via a Tiny Catheter

Implantation of Cardioverter Defibrillator After Percutaneous Closure of Atrial Septal Defect

Title of image and video article Sub-Acute Leaflet Thrombosis: A Reversible Cause of Aortic Stenosis

Atrial fibrillation (AF), one of the

Clinicians and Facilities: RESOURCES WHEN CARING FOR WOMEN WITH ADULT CONGENITAL HEART DISEASE OR OTHER FORMS OF CARDIOVASCULAR DISEASE!!

Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septa1 Defect Closure

Perventricular Closure of Muscular VSD

Complicated Percutaneous Repair of a Paravalvular Mitral Leak. Dr. K Kam Resident Specialist Division of Cardiology, PWH M&T (Courtesy: Prof.

Edwards Sapien. Medtronic CoreValve. Inoperable FDA approved High risk: in trials. FDA approved

Echo Evaluation of a Mitral Valve Prostheses Sunday, February 14, :50 2:10 PM 20 min

How should I treat a percutaneous posteromedial mitral periprosthetic paravalvular leak closure in a bioprosthesis with no radiopaque ring?

Update on Percutaneous Therapies for Structural Heart Disease. William Thomas MD Director of Structural Heart Program Tucson Medical Center

Transcatheter CoreValve valve-in-valve implantation in a stentless porcine aortic valve for severe aortic regurgitation

Cite this article as:

Outcomes of Mitral Valve Repair for Mitral Regurgitation Due to Degenerative Disease

During the last few years, adult

Effect of Valve Suture Technique on Incidence of Paraprosthetic Regurgitation and 10-Year Survival

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

Tayyar Gökdeniz, Emre Ertürk, M. Ali Astarcıoğlu, Sabahattin Gündüz, A. Çağrı Aykan, A. Emrah Oğuz, Zübeyde Bayram, Mustafa Yıldız, N.

Diversion of the inferior vena cava following repair of atrial septal defect causing hypoxemia

Transcatheter Aortic Valve Implantation Procedure (TAVI)

Percutaneous Therapy for Calcific Mitral Valve Disease

Mitral Regurgitation

Case 47 Clinical Presentation

Successful percutaneous treatment of late-onset femoral pseudoaneurysm after transcatheter, aortic valve implantation procedure

What is TAVR? Transcatheter Aortic Valve Replacement

Acute dissections of the descending thoracic aorta (Debakey

Echocardiographic Evaluation of Aortic Valve Prosthesis

Transcatheter Heart Valve. Replacement. With the Edwards SAPIEN 3. for Patients & Caregivers

Percutaneous mitral valve repair/replacement. Jan Van der Heyden MD, PhD St.Antonius Hospital Nieuwegein

Case submission for CSI Asia-Pacific Case 2

Minimalist Transcatheter Aortic Valve Replacement (MA-TAVR)

HOW IMPORTANT ARE THESE ECHO MEASUREMENTS ANYWAY?

Transcatheter Mitral Valve for fmr: The Era of Too Many Options

Transcatheter closure of right coronary artery fistula to the right ventricle

Paravalvular leak (PVL) is a rare but important

April 16, 09:00-09:15 중앙대학교 윤신원

Original Date: October 2009 TRANSESOPHAGEAL (TEE) ECHO Page 1 of 6

Paediatrica Indonesiana

Treatment of Bio-Prosthetic Valve Deterioration Using Transcatheter Techniques

Cardiac Radiology In-Training Test Questions for Diagnostic Radiology Residents

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type.

ICE: Echo Core Lab-CRF

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Transcription:

Case Report Hellenic J Cardiol 2014; 55: 342-347 Paravalvular Aortic Prosthetic Valve Leak Closure: Technical Aspects of the Percutaneous Approach Stavros Hadjimiltiades 1, Antonis Ziakas 1, Vasilis Grosomanidis 2, Haralambos Karvounis 1, George Misias 3, Kyriakos Anastasiadis 3, John Styliadis 1 1 Department of Cardiology, 2 Department of Anesthesiology, 3 Department of Cardiothoracic Surgery, AHEPA University Hospital, Thessaloniki, Greece We describe the successful closure of an aortic paravalvular bioprosthetic valve leak with the simultaneous percutaneous deployment of two vascular plugs. Key words: Prosthetic paravalvular leaks, paravalvular defect closure, vascular plug II. Manuscript received: August 22, 2012; Accepted: August 2, 2013. Address: Stavros Hadjimiltiades Department of Cardiology AHEPA University Hospital 1 Stilponos Kyriakidi St. Thessaloniki, Greece e-mail: stavros@otenet.gr Paravalvular leaks (PVL) are common following surgical valve replacement. Systematic evaluation with transesophageal echocardiography (TEE) revealed that paravalvular leaks with trivial or mild regurgitation are present at hospital discharge in up to 17.6% of all cases after aortic valve replacement and in 22.6% of all cases after mitral valve replacement. 1 The available data confirm that new regurgitant jets can develop during follow up, even without the occurrence of endocarditis. 2 Clinically significant paravalvular leaks that warrant repair occur in 1-4% of patients with prosthetic valves. 3 It is well-known that heart valve reoperations are associated with a high but variable operative risk. 4,5 Percutaneous treatment of paravalvular prosthetic regurgitation has emerged as a safe and less invasive alternative, with feasibility demonstrated in case reports and two large series 6,7 but an estimated 64.5% 3-year survival, with mortality mainly related to the presence of significant residual paravalvular regurgitation and comorbidities. 8 In this study, one fourth of the patients were left with moderate to severe residual regurgitation and only one half had improvement of hemolytic anemia. This procedure is infrequently performed and the technical information that is gained is very important for the future development of closure devices and the effective use of existing devices in paravalvular defect closure. Considering the increasing number of percutaneous aortic valve implantations, with their associated higher incidence of paravalvular leaks, it is likely that this procedure will become much more frequently performed. Case presentation A 71-year-old male patient, hypertensive, diabetic on oral medications, underwent coronary artery bypass surgery and aortic valve replacement for severe three-vessel disease and moderate aortic stenosis. The valve was a bioprosthetic Edwards Perimount 21 mm valve. The patient improved significantly after the operation, but one and a half months later he was admitted to another hospital with pulmonary edema, after which he was incapacitated with dyspnea on minimal exertion. On transthoracic 342 HJC (Hellenic Journal of Cardiology)

Paravalvular Aortic Prosthetic Valve Leak Closure echocardiography, he had preserved left ventricular function and an aortic prosthetic valve in a stable position, but with severe paravalvular regurgitation. A 2D transesophageal echocardiogram revealed a crescent shaped defect (Figure 1). There was no clinical or laboratory evidence of endocarditis. A coronary angiogram demonstrated patency of the left internal thoracic artery to the left anterior descending artery, and patency of the vein grafts to the diagonal, obtuse marginal and right coronary arteries. An aortogram confirmed the presence of severe aortic regurgitation. Review of the 2D TEE revealed only one paravalvular jet through an oblong defect, on the posterior side of the non-coronary part of the ring. Based on the contour of the color flow at end-diastole, the defect was measured at 5-6 mm at its widest part and 14 mm at its longest (Figure 1). There was a space of at least 8 mm between the valve ring and the aortic sinus wall. We decided to close the defect percutaneously, with simultaneous deployment of two Amplatzer vascular plug II devices (St Jude Medical), 8 mm in diameter (Figure 2). Repeat surgery to repair the defect was an initial option, but with a Society of Thoracic Surgeons mortality score of 4.4%, and a mortality and morbidity score of 26.1%, 9 the cardiothoracic team insisted on a percutaneous approach. The procedure was performed 5 months after the initial operation, with the patient under general anesthesia and the use of 2D TEE. The patient was premedicated with aspirin, clopidogrel and heparin, and antibiotics for endocarditis prophylaxis. The patient was in sinus rhythm with a complete right bundle branch block pattern on the electrocardiogram; a pacemaker wire was positioned in the right ventricle as a precaution. Two Arrow 7F 45 cm sheaths (St Jude Medical) were used for better support and were inserted through the right and left femoral arteries. Two multipurpose (MP) 6F guide catheters with the standard length of 100 cm (Launcher, Medtronic) were positioned through the paravalvular defect into the left ventricle using the child and mother technique, achieving a smooth transition and thus avoiding the edge of the guiding catheter catching on the rims of the defect. A multipurpose 5F angiographic catheter 125 cm in length (Cordis), was inserted into the 6F guide catheter over a 0.035 polymer-covered nitinol wire (Terumo Medical). We selected the multipurpose angiographic catheter for the posteriorly located defect, but depending on the location of the defect another tip shape could have been selected: e.g. 5.5 mm 14 mm Figure 1. Two-dimensional transesophageal echocardiogram at the level of the aortic valve with color flow at end-diastole delineates a crescent shaped defect in the non-coronary part of the aortic ring. The defect was measured to be 5-6 mm at its widest part and less than 14 mm at its longest. The black asterisks mark the three struts of the bioprosthetic valve. LA left atrium, AV aortic valve. Figure 2. The Amplatzer Vascular Plug II device, which was used in our case, is cylindrical with discs on either side of the main part of the plug, each connected by a thin waist to the main part, permitting the device to be pulled against the valve ring. Amplatz left or right. The defect was crossed with the two wires oriented posteriorly in the right anterior oblique projection, but the location of the wires outside the valve ring was verified in cranial views. The angiographic catheters were advanced into the left ventricle and, with the angiographic catheter and wire as support, the guiding catheters were telescoped one by one into the left ventricle, with no need for a stiffer wire support. LA AV (Hellenic Journal of Cardiology) HJC 343

S. Hadjimiltiades et al The two vascular plug II 8 mm devices were advanced one by one and the discs, the first of the three segments of the device, were deployed in the left ventricle. It is worth mentioning that the advancement of the device through the last part of the 6F guiding catheter was extremely difficult, possibly because of friction in the angulated part of the catheter or in an unapparent compression of the catheter at the level of the valve ring. One disk was pulled until resistance was felt and it was presumably anchored at one end of the defect. The device was fully deployed but remained under tension, until the other device was similarly fully deployed and then both devices were pushed. The 2D echocardiogram in multiple projections, with the devices still attached to their delivery cables, did not reveal any paravalvular regurgitation jets. Contrast dye injection through the guiding catheters revealed a small amount of leakage around the posterior device disc, the one that was fully deployed first, and leakage through the valve. After careful consideration the devices were released (Figure 3). A repeat aortogram revealed only mild aortic regurgitation. The 2D TEE, after the release of the devices, revealed only one small jet (Figure 4). No conduction abnormalities were observed during the procedure. The patient was discharged on aspirin and clopidogrel for at least a 6-month period. A month later the patient remained asymptomatic and a new TEE revealed trivial paravalvular regurgitation. There was no laboratory evidence of hemolysis, with LDH levels and haptoglobin levels in the normal range and a stable hemoglobin level. Discussion Figure 3. Right anterior and cranial view of the prosthetic aortic valve after deployment and release of the two 8 mm Amplatzer Vascular Plug II devices. The arrows point to the waist between the discs, on the ventricular side, and the deformed main parts of the devices, which close the defect. RC right coronary cusp part of the ring; LC left coronary cusp part of the ring. 0 45 180 LA AV The ability to close a paravalvular prosthetic valve leak percutaneously is very appealing to both the patient and the cardiac surgeon. Since its first inception by Hourihan in 1992, 10 an increasing number of published reports have demonstrated the feasibility of the percutaneous closure of these periprosthetic defects (Table 1). The devices that have been mainly used belong to the Amplatzer family of nitinol mesh occluders. These devices (atrial septal occluder, ventricular septal occluder, duct occluder, vascular plug II) are not designed for this specific task: i.e. plugging holes of different shapes between the edge of a prosthetic valve ring and the surrounding tissue, which is potentially prone to tearing. Nonetheless, in a large percentage of patients, the use of appropriately sized devices or multiple smaller devices resulted in a significant reduction of regurgitation and hemolysis, 6,7 with improved results over the follow-up period due to thrombosis and endothelization of the device. 22 On the other hand, in a number of patients, the results were not satisfactory, because of the device s inability to conform to the shape of the defect, or extension of the defect due to the cylindrical shape of the devices and their self expanding nature, 18,20 or worsening of hemolysis because of the high velocity LC RC LA P +52.2-52.2 cm/s Figure 4. Two-dimensional transesophageal echocardiogram at the level of the aortic valve (AV) with color flow at mid-diastole, demonstrating a small residual paravalvular defect with trivial flow. LA left atrium. 344 HJC (Hellenic Journal of Cardiology)

Paravalvular Aortic Prosthetic Valve Leak Closure Table 1. Published reports of percutaneous aortic paravalvular leak (PVL) closures, mainly with the Amplatzer devices, including unsuccessful cases reported by surgeons. The number of mitral PVL closures is also included in the reports. Author (reference) Year # patients # leaks Device/s Clinical success Hourihan 10 1992 4 A (4) Double umbrella 3/4 Webb 11 2005 1 A (1) Duct occluder 1/1 Pate 12 2006 10 M (9) A (1) Duct occluder 1/1 Dussaillant GR 13 2006 1 A (1) Duct occluder 1/1 Hein R 14 2006 21 M (13) A (8) Duct occluder - mvsd 8/8 Shapira Y 15 2007 11 M (10) A (3) mvsd pvsd 2/3 Hildick-Smith D 16 2007 1 A (1) mvsd occluder 1/1 Kahn A 17 2008 1 A (1) Vascular plug 1/1 Bairaktaris A 18 2008 3 M (1) A (2) Duct occluder 0/2 Philips S 19 2009 1 A (1) ASD occluder 1/1 Castedo E 20 2009 1 A (1) Vascular plug 0/1 Alonso-Briales JH 21 2009 8 M (4) A (4) Duct occluder 2/4 Hammerstingl C 22 2009 1 A (1) VPIII vascular plug 1/1 Neitlspach F 23 2010 5 M (4) A (1) VPIII vascular plug 1/1 Smolka G24 2010 3 M (1) A (2) VPII vascular plug 2/2 Hoffmayer K 25 2011 1 A (1) mvsd occluder, VPII 1/1 Sharma M 26 2011 1 A (1) Duct occluder 1/1 Ruiz 6 2011 43 M (38) Duct occluder A (11) mvsd occluder 8/11 VPIII vascular plug Sorajje P 7 2011 126 M (124) A (30) VPII vascular plug 22/30 Guzman MAP 27 2011 51 M (57) A (9) VPIII vascular plug 9/9 Gökoğlan Y 28 2012 1 A (1) Duct occluder 1/1 Trayer T 29 2012 2 A (2) VPII vascular plug 2/2 A (88) 71/88 M mitral, A aortic, mvsd muscular ventricular septal defect, pvsd perimembranous ventricular septal defect, ASD atrial septal defect. Figure 5. The Amplatzer Vascular Plug III device is oblong, with the disc on the ventricular side (retrograde deployment), protruding by 2 mm with no waist, imposing some limitations on device sizing. jet crossing through the device or through a residual defect. 6,14 A purpose-specific device, the Amplatzer vascular plug III (St Jude Medical) has been evaluated in a few patients, but has shown no clear clinical advantage over the other devices in the aortic position (Table 1). This device is oblong with short rims (Figure 5), better suited for crescent-shaped defects, but the deployment is more demanding because the device has to be oriented appropriately and larger delivery catheters are required; in addition the device is held in place mainly by compression of the body of the device by the rims of the defect, offering better sealing, with the danger of defect extension and unstable seating. The Amplatzer duct occluder and the ventricular defect occluder, with a similar mechanism of retention, have been used successfully, but have a stiffer and wider mesh and incorporate a polyester fabric. (Hellenic Journal of Cardiology) HJC 345

S. Hadjimiltiades et al The vascular plug II has a tight mesh with thin nitinol wires similar to the vascular plug III, but has a thin waist between the disc that holds the device on the ventricular side and a conformable body that plugs the defect from the aortic side (Figure 2). This provides more secure retention, probably with less danger of extending the defect, as compared to a device that expands inside the defect. The use of two devices side by side in crescent shaped defects, as seen in our case, requires smaller delivery catheters across the defect, may pose less of a problem in interfering with the valve function as compared to a single larger device, and seems to be effective in this type of defect. We opted to deploy the two devices simultaneously for three reasons: a faster procedure, a more symmetrical deployment of the devices, and avoidance of a step approach that would have made the selection of a second device difficult, without the availability of continuous 3D echocardiography. 23,25 Conclusion Percutaneous closure of paravalvular aortic prosthetic leaks with the Amplatzer vascular plug II, although not ideal, can be an effective and safe procedure, but one that requires meticulous preparation in selecting the size of the closure device. The simultaneous deployment of two smaller devices seems to be a fast technique that is well adapted to oblong defects. References 1. Ionescu A, Fraser AG, Butchart EG. Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography. Heart. 2003; 89: 1316-1321. 2. Jindani A, Neville EM, Venn G, Williams BT. Paraprosthetic leak: a complication of cardiac valve replacement. J Cardiovasc Surg (Torino). 1991; 32: 503-508. 3. Schaff HV, Carrel TP, Jamieson WR, et al. Paravalvular leak and other events in silzone-coated mechanical heart valves: a report from AVERT. Ann Thorac Surg. 2002; 73: 785-792. 4. Miller DL, Morris JJ, Schaff HV, Mullany CJ, Nishimura RA, Orszulak TA. Reoperation for aortic valve periprosthetic leakage: identification of patients at risk and results of operation. J Heart Valve Dis. 1995; 4: 160-165. 5. Leontyev S, Borger MA, Davierwala P, et al. Redo aortic valve surgery: early and late outcomes. Ann Thorac Surg. 2011; 91: 1120-1126. 6. Ruiz CE, Jelnin V, Kronzon I, et al. Clinical outcomes in patients undergoing percutaneous closure of periprosthetic paravalvular leaks. J Am Coll Cardiol. 2011; 58: 2210-2217. 7. Sorajja P, Cabalka AK, Hagler DJ, Rihal CS. Percutaneous repair of paravalvular prosthetic regurgitation: acute and 30- day outcomes in 115 patients. Circ Cardiovasc Interv. 2011; 4: 314-321. 8. Sorajja P, Cabalka AK, Hagler DJ, Rihal CS. Long-term follow-up of percutaneous repair of paravalvular prosthetic regurgitation. J Am Coll Cardiol. 2011; 58: 2218-2224. 9. STS Risk Calculator [Internet]. Chicago: The Society of Thoracic Surgeons. Available from: http://www.sts.org/sections/ stsnationaldatabase/riskcalculator/ 10. Hourihan M, Perry SB, Mandell VS, et al. Transcatheter umbrella closure of valvular and paravalvular leaks. J Am Coll Cardiol. 1992; 20: 1371-1377. 11. Webb JG, Pate GE, Munt BI. Percutaneous closure of an aortic prosthetic paravalvular leak with an Amplatzer duct occluder. Catheter Cardiovasc Interv. 2005; 65: 69-72. 12. Pate GE, Al Zubaidi A, Chandavimol M, Thompson CR, Munt BI, Webb JG. Percutaneous closure of prosthetic paravalvular leaks: case series and review. Catheter Cardiovasc Interv. 2006; 68: 528-533. 13. Dussaillant GR, Romero L, Ramírez A, Sepúlveda L. Successful percutaneous closure of paraprosthetic aorto-right ventricular leak using the Amplatzer duct occluder. Catheter Cardiovasc Interv. 2006; 67: 976-980. 14. Hein R, Wunderlich N, Robertson G, Wilson N, Sievert H. Catheter closure of paravalvular leak. EuroIntervention. 2006; 2: 318-325. 15. Shapira Y, Hirsch R, Kornowski R, et al. Percutaneous closure of perivalvular leaks with Amplatzer occluders: feasibility, safety, and shortterm results. J Heart Valve Dis. 2007; 16: 305-313. 16. Hildick-Smith D, Behan MW, De Giovanni J. Percutaneous closure of an aortic paravalvular leak via the transradial approach. Catheter Cardiovasc Interv. 2007; 69: 708-710. 17. Khan A, Ruygrok PN, Nakpathomkun P, Gerber IL. Percutaneous transcatheter obliteration of aortic paravalvular leak. N Z Med J. 2008; 121: 80-82. 18. Bairaktaris A, Haas NA, Seifert D, et al. Pitfalls in catheterbased interventions to treat paravalvular leaks. J Thorac Cardiovasc Surg. 2008; 136: 1076-1077. 19. Phillips SA, Thompson A, Abu-Halimah A, Crenshaw MH, Zhao DX, Pretorius M. Percutaneous closure of aortic prosthetic paravalvular regurgitation with two amplatzer septal occluders. Anesth Analg. 2009; 108: 437-438. 20. Castedo E, Serrano-Fiz S, Oteo JF, Ramis S, Martinez P, Ugarte J. Failure of percutaneous closure of prosthetic, aortic paravalvular leak. Ann Thorac Surg. 2009; 88: 1327-1329. 21. Alonso-Briales JH, Muñoz-García AJ, Jiménez-Navarro MF, et al. Closure of perivalvular leaks using an Amplatzer occluder. Rev Esp Cardiol. 2009; 62: 442-446. 22. Hammerstingl C, Werner N, Nickenig G. Symptomatic paravalvular leakage after mechanical aortic valve replacement in a critically ill patient: why not just plug the hole? Eur J Echocardiogr. 2009; 10: 576-578. 23. Nietlispach F, Johnson M, Moss RR, et al. Transcatheter closure of paravalvular defects using a purpose-specific occluder. JACC Cardiovasc Interv. 2010; 3: 759-765. 24. Smolka G, Ochała A, Jasiński M, Pysz P, Biernat J, Gasior Z. Percutaneous treatment of periprosthetic valve leak in patients not suitable for reoperation. Kardiol Pol. 2010; 68: 369-373. 346 HJC (Hellenic Journal of Cardiology)

Paravalvular Aortic Prosthetic Valve Leak Closure 25. Hoffmayer KS, Zellner C, Kwan DM, et al. Closure of a para-valvular aortic leak: with the use of 2 AMPLATZER devices and real-time 2- and 3-dimensional transesophageal echocardiography. Tex Heart Inst J. 2011; 38: 81-84. 26. Sharma M, Tseng E, Schiller N, Moore P, Shunk KA. Closure of aortic paravalvular leak under intravascular ultrasound and intracardiac echocardiography guidance. J Invasive Cardiol. 2011; 23: E250-254. 27. Guzman MAP, Dutary JR, Hernandez-Antolin R, Almeria C, Gorgadze T, Garcia E. Percutaneous closure of paravalvular leaks with Amplatzer Vascular Plug III device: immediate and midterm results. J Am Coll Cardiol. 2011; 57: E1685. 28. Gökoğlan Y, Demirkol S, Kurt IH, et al. Percutaneous effective closure of severe aortic prosthetic paravalvular leak using Amplatzer duct occluder device with the guidance of 3D TEE. Anadolu Kardiyol Derg. 2012; 12: 181-182. 29. Trayer T, Kovach R, George JC. Percutaneous paravalvular leak closure in the aortic position. Cath Lab Digest. 2012; 3: 24-28. (Hellenic Journal of Cardiology) HJC 347