Comparative Study of Arterial Compliance Using Invasive and Noninvasive Blood Pressure Waveform

Similar documents
Changes in Blood Pressure and Vascular Physiology: Markers for Cardiovascular Disease

Which method is better to measure arterial stiffness; augmentation index, pulse wave velocity, carotid distensibility? 전북의대내과 김원호

TODAY S TOPIC Blood Pressure & Pulse Wave Measurement Combined in One Procedure Re-classification of Risk Patients

The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography

Cardiovascular Diseases Detecting via Pulse Analysis

EVALUATION OF NONINVASIVE PULSE TRANSIT TIME METHODOLOGIES FOR DIAGNOSIS OF HYPERTENSION DANIEL JOHN BADGER. A thesis submitted to the

Impedance Cardiography (ICG) Method, Technology and Validity

A GUIDE TO OUR NIBP TECHNOLOGY

Determination of age-related increases in large artery stiffness by digital pulse contour analysis

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

Diverse Techniques to Detect Arterial Stiffness

The Conduit Artery Functional Endpoint (CAFE) study in ASCOT

IS PVR THE RIGHT METRIC FOR RV AFTERLOAD?

Blood Pressure Monitor PASESA

Coronary artery disease (CAD) risk factors

Carotid and radial pulse feature analysis with EMFi sensor

Cigarette smoking is one of the most important avoidable

Pulse wave velocity, augmentation index and arterial age in students

Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

Relationship between Radial and Central Arterial Pulse Wave and Evaluation of Central Aortic Pressure Using the Radial Arterial Pulse Wave

Clinical application of Arterial stiffness. pulse wave analysis pulse wave velocity

Various Indices of Arterial Stiffness: Are They Closely Related or Distinctly Different?

Chapter 01. General introduction and outline

Special Lecture 10/28/2012

Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination

(received 23 September 2004; accepted 18 October 2004)

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

An Indian Journal FULL PAPER ABSTRACT KEYWORDS. Trade Science Inc.

Estimation of arterial pulse wave velocity with a new improved Tissue Doppler method

3 Aging, Arterial Stiffness,

APPLICATION OF PHYSICAL METHODS FOR DETERMINATION OF FUNCTIONAL PARAMETERS OF ARTERIES IN RHEUMATIC PATIENTS

A chronic increase in blood pressure is a major risk factor for cardiovascular disease, whereas reducing

Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis

A Simulation for Estimation of the Blood Pressure using Arterial Pressure-volume Model

Low fractional diastolic pressure in the ascending aorta increased the risk of coronary heart disease

Nomogram of the Relation of Brachial-Ankle Pulse Wave Velocity with Blood Pressure

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME

External Oscillatory Blood Pressure - EOBPTM

Blood Pressure Estimation Using Photoplethysmography (PPG)

Mechanisms of heart failure with normal EF Arterial stiffness and ventricular-arterial coupling. What is the pathophysiology at presentation?

QUIZ 1. Tuesday, March 2, 2004

Dynamic measures of arterial stiffness in a rodent model

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Cardiovascular disease is the major

Cover Page. The handle holds various files of this Leiden University dissertation

PULSE WAVE VARIABILITY WITHIN TWO SHORT-TERM MEASUREMENTS. David Korpas, Jan Halek

Impedance Cardiography (ICG) Application of ICG for Hypertension Management

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

Blood Pressure Determination Using Analysis of Biosignals

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

Arterial Age and Shift Work

Topic 6: Human Physiology

Fondazione C.N.R./Regione Toscana G. Monasterio Pisa - Italy. Imaging: tool or toy? Aortic Compliance

EFFECTS OF CHANGES IN WEIGHT, BODY COMPOSITION, FITNESS AND PHYSICAL ACTIVITY ON AORTIC WAVE VELOCITY IN OVERWEIGHT AND OBESE ADULTS.

CONSIDERATIONS ABOUT THE LUMPED PARAMETER WINDKESSEL MODEL APPLICATIVITY IN THE CARDIOVASCULAR SYSTEM STRUCTURE

Summary. Introduction

The augmentation index (AI) is the ratio of the ejection

The Value of a BP Determination Method Using a Novel Non-Invasive BP Device against the Invasive Catheter Measurement

Test-Retest Reproducibility of the Wideband External Pulse Device

Key words: Second derivative of plethysmogram, Plethysmogram, Arterial distensibility, Atherosclerosis

Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D.

Arterial stiffness index: A new evaluation for arterial stiffness in elderly patients with essential hypertension

Estimation of pressure pulse amplification between aorta and brachial artery using stepwise multiple regression models

John Feely deceased. Received 21 October 2008 Revised 5 June 2009 Accepted 28 June 2009

Arterial Stiffness: pathophysiology and clinical impact. Gérard M. LONDON Manhès Hospital Fleury-Mérogis/Paris, France

PRELIMINARY STUDIES OF LEFT VENTRICULAR WALL THICKNESS AND MASS OF NORMOTENSIVE AND HYPERTENSIVE SUBJECTS USING M-MODE ECHOCARDIOGRAPHY

Η σημασία της αρτηριακής σκληρίας στην εκτίμηση της διαστολικής δυσλειτουργίας στην υπέρταση. Θεραπευτικές παρεμβάσεις

IB TOPIC 6.2 THE BLOOD SYSTEM

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

Arterial stiffness and central BP as goals for antihypertensive therapy in pre- and elderly. Piotr Jankowski

Feasibility of Aortic Pulse Pressure and Pressure Wave Velocity MRI Measurement in Young Adults

Cut-Off Value of the Ankle-Brachial Pressure Index at Which the Accuracy of Brachial-Ankle Pulse Wave Velocity Measurement is Diminished

Blood Pressure Laboratory

INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS

Estimated Pulse Wave Velocity Calculated from Age and Mean Arterial Blood Pressure

Validation of a New Index for Estimating Arterial Stiffness: Measurement of the QPV Interval by Doppler Ultrasound

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea

Oscillometric pressure pulse waveforms: their current and prospective applications in biomedical instrumentation

Basic Approach to the Echocardiographic Evaluation of Ventricular Diastolic Function

Departments of Cardiology and Vascular Surgery Michaelidion Cardiac Center University of Ioannina, Greece

37 1 The Circulatory System

Special Lecture 11/08/2013. Hypertension Dr. HN Mayrovitz

Disclosures. Afterload on the PV loop. RV Afterload THE PULMONARY VASCULATURE AND ASSESSMENT OF THE RIGHT VENTRICLE

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG

Development of 4D dynamic simulation tool for the evaluation of left ventricular myocardial functions

ARTERIAL STIFFNESS AND CORONARY ARTERY DISEASE

The Circulatory System. Lesson Overview. Lesson Overview The Circulatory System

IB TOPIC 6.2 THE BLOOD SYSTEM

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 1, July 2014

Central Blood Pressure

Relationship between Arterial Stiffness and the Risk of Coronary Artery Disease in Subjects with and without Metabolic Syndrome

The arterial system has a dual function:

The Seventh Report of the Joint National Committee on

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

Managing cardiovascular risk with SphygmoCor XCEL

Local control of large arteries buffering function: role of the vascular smooth muscle.

boso Germany PAOD! The crucial Premium-quality risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system!

Comparison between pulse wave velocities measured using Complior and measured using Biopac

Transcription:

Journal of Biomedical Engineering and Technology, 2017, Vol. 5, No. 1, 25-29 Available online at http://pubs.sciepub.com/jbet/5/1/5 Science and Education Publishing DOI:10.12691/jbet-5-1-5 Comparative Study of Arterial Compliance Using Invasive and Noninvasive Blood Pressure Waveform I-Lu Chen, Yashbir Singh, Wei-Chih Hu * Department of Biomedical Engineering, Chung Yuan Christian University, Zhongli, Taiwan *Corresponding author: weichihhu@cycu.edu.tw Abstract Most of the epidemiological studies have shown a good relationship between blood pressure and manifestation of cardiovascular diseases (CVD). CVD has become a very common health condition that exhibits significant changes in distensibilility, compliance, and elastic modulus of the arterial vascular system. The main causes of this disease are the spreading of fats and cholesterols which initiate the damaging of endothelium, decreasing wall buffering capacity, and hardening of the arteries eventually leading to severe narrowing. We compared data from invasive and non-invasive blood pressure wave form. Using the Windkessel model, to estimate the arterial compliance as vascular index, we used data after the aortic valve closed to the end-diastolic point of blood pressure waveforms, utilized Bland-Altman difference plot, T-test, box whisker plot and scatter diagram. We analyzed physiological real data and investigated the correlation between the non-invasive and invasive blood pressure wave form. Non-invasive compressive pulse waveforms can be used to assess the total compliance of the arterial blood pressure waveforms of the invasive aorta that indicates the buffering of muscle and adipose tissue. Keywords: cardiovascular disease, arterial compliance, Windkessel model, non-invasive blood pressure waveform Cite This Article: I-Lu Chen, Yashbir Singh, and Wei-Chih Hu, Comparative Study of Arterial Compliance Using Invasive and Noninvasive Blood Pressure Waveform. Journal of Biomedical Engineering and Technology, vol. 5, no. 1 (2017): 25-29. doi: 10.12691/jbet-5-1-5. 1. Introduction In current times, cardiovascular diseases (CVD) have become the foremost component of mortality statistics in the world [1,2]. It is estimated that approximately 78% of deaths and 86% morbidity are caused because of CVD worldwide. Reports suggest that CVD will be the global health burden by 2020 [3,4]. This disease follows an asymptomatic phase of development which builds up in the body silently over a period of time without any major sign on an individual s health [5]. Many recent studies demonstrated the relationship between biological aging and arteriosclerosis towards the risk of cardiovascular diseases, such as hypertension, hypercholesterolemia, and end-stage renal failure. With aging, the arterial wall thickness and dilation, lengthening become less compliant and increases pulse wave velocity which result in wave reflections [6,7]. The extensive changes in the inner wall of the artery, affects the elasticity of fibers which are responsible for vessel distensiblility. The rising curiosity of non-invasive arterial compliance detection led many researchers to work in the field and put forth methods to estimate the arterial compliance. Prior research of cardiovascular structure and function is based on invasive intra-arterial cannulation to get the arterial pulse wave [8]. The change in arterial pulse wave is a passive consequence of increase in the blood pressure. In physiology, compliance (C) = dv/dp (Ratio of the change in volume (dv) resulting from change in pressure (dp)). Compliance represents the slope of the pressure-volume relationship [9,10]. In the context of an electric circuit, this is analog as to the Windkessel model that simulates blood pressure dynamics in the systemic arteries [11]. When stiffness occur then wide pulse pressure, systolic hypertension, and increased cardiovascular risk increase, because wide pulse pressure and systolic hypertension are late indicators of the arteriosclerotic process. There is important attention to develop more sensitive compliance measurements that can determine premature vascular stiffening at an earlier stage [12]. In this work, we aimed to scrutinize a method of evaluating arterial compliance using non-invasive blood pressure waveform which could be a prevailing method for medical science. Here, we used a dataset which is examined under the supervision of a physician on standardized conditions and we subsequently implemented a mathematical approach. This research work proved that a noninvasive method for the detection of blood pressure is significantly and more precise, compared for the invasive approach. 2. Method The overall framework in this paper has been majorly grouped into various categories, namely, Study population, data extraction, algorithm implementation, waveform computation and experimental architecture.

26 Journal of Biomedical Engineering and Technology 2.1. Study Population All study protocols are approved by the Institutional Review Board of Taipei Veterans General Hospital (IRB) and adhered to the principles of the Declaration of Helsinki [Table 1]. Table 1. Physiological Data Characteristics Subjects(n=15) L-brachial(cm) 47.73±4.22 blood pressures,(mmhg) NTG before NTG after Systolic Blood pressure 134.6±18.55 123.13±13.37 Mean Blood Pressure 88.33±10.56 85.33±10.19 Diastolic Blood Pressure 76.4±9.65 72.47±8.73 Heart rate (BPM) 58.33±15.99 50.93±11.43 2.2. Data Extraction In this step, we extracted data from a non-invasive vascular screening device (Colin VP2000, Omron, Japan) (Figure 1) that measures non-invasively blood pressure [13] which supports early detection and diagnosis of arteriosclerosis. Figure 1. Non-invasive Vascular Screening Device, (Colin VP2000, Omron, Japan): This device provides indices of PWV (pulse wave velocity) and pulse waveforms, which is applicable for detection and diagnosis of arteriosclerosis. The conditions of patients must the Circumference of arm 16-38 cm In case of invasive blood pressure data acquisition, we used a Millar catheter (Figure 2) which consists of a dual pressure sensor [14]. This device can capture invasive blood pressure waveform of two arterial positions simultaneously. Figure 2. Invasive blood pressure data acquisition (Millar catheter): There is dual pressure sensor. This device captures two different arterial position of the invasive blood pressure waveform. 2.3. Algorithm Implementation We use the Windkessel model to estimate the arterial compliance (decay constant) as a vascular index using data after aortic valve close to the end diastolic point of blood pressure waveforms [11] t t Pt ( ) = Pt ( 0) e RC = Pt ( 0) e α (i) P (t): Blood pressure value at time (t), P (t0): Blood pressure value at time (t0), t: time (t); R: Resistance of the blood vessel; C: compliance; α: Decay constant 2.4. Waveform Computation We used an algorithm (equation (i)) to calculate blood pressure wave data. We have already used noninvasive data from Oscillometer and pulse volume recording (PVR); invasive data was taken from aorta and bronchial artery (Figure 3). After getting data, we propose invasive and non-invasive degree of arterial compliance using a Bland- Altman difference plot [15], t-test [16], box whisker plot [17] and scatter diagram [18]. 2.5. Experimental Architecture We took a group of 15 patients for this experiment; the purpose of this study was explained and written consent was taken from them. After that we measured simultaneously invasive and non-invasive blood pressure waveform signal with Oscillometer and Millar catheter, before and after applying nitro-glycerin drug (NTG). Figure 3. Assessment section for invasive and noninvasive: In this graph blue line represents the blood pressure waveform and red line is the assessment section (Condition is aortic valve closed) that is decay constant α

Journal of Biomedical Engineering and Technology 27 3. Results 3.1. Estimation of Decay Constant We evaluated the time decay constant for arterial compliance of the aorta and the upper arm artery at the time end of the diastolic blood pressure using pulsator. The relationship is compared between arterial compliance and times constants. By using invasive and non-invasive waveforms, we analyze arterial compliance index, which is used to assess the degree of compliance (Figure 4, Table 3). The arterial compliance of invasive and non-invasive type of blood pressure waveform was evaluated before and after taking NTG [Table 2]. NTG is a coronary dilator that expands the coronary artery to improve the blood flow, oxygen supply and reduce the heart load [19]. Firstly, it is assumed that the arterial compliance can be estimated through the invasive aortic blood pressure waveform; when we estimated blood pressure waveform using pulsator, then it reflects the arterial compliance [Figure 5]. The characteristics of the invasive blood pressure waveform can be used to replace the invasive blood pressure waveform that estimates arterial compliance. If both previous hypotheses are considered true, it can be prove that the arterial compliance estimated using a noninvasive cuff waveform, can be used as a predictor of hardening arteries. Correlation evaluation between Invasive and Non-invasive data: The arterial compliance of the invasive brachial blood pressure waveform is highly correlated with the arterial compliance of the invasive aortic blood pressure waveform (R 2 = 0.8351, P <0.0001), the invasive upper arm arterial blood pressure waveform can be replace to invasive aortic blood pressure waveform (R 2 = 0.1235, R 2 = 0.1076, P <0.0001), noninvasive and invasive aortic blood pressure waveforms, brachial arterial blood pressure waveforms are also shown significant correlation (Table 4). Table 2. This table exhibits mean time decay constant for arterial compliance of blood pressure waveforms Waveform\C Decay NTG before mean±sd NTG after mean±sd Aortic -0.6070±0.1297-0.5378±0.1246 Brachial -0.5811±0.1106-0.5275±0.0773 artcuff -0.1892±0.0685-0.15227±0.0792 Table 3. Mean time decay constant for arterial compliance of blood pressure waveforms Waveform\C Decay NTG before mean±sd NTG after mean±sd Aortic -0.6070±0.1237-0.5378±0.1214 Brachial -0.5811±0.1039-0.5275±0.0736 Artcuff -0.1892±0.0446-0.1523±0.0640 Figure 4. Evaluation of Decay constant: This graph is plotted magnitude vs time which is X and Y axis respectively. The peak of waveform is mean arterial pressure (MAP), before MAP 50% of magnitude is called time for finding systolic blood pressure, After MAP 80% magnitude time for finding diastolic pressure. Blue color waveform is aortic time decay constant, green is brachial artery decay constant and red color waveform is the non-invasive decay constant Figure 5. Comparison between invasive and non-invasive wave form: In this graph, green colour is showing brachial, red is aortic which is invasive. In non-invasive, we used two different filter for getting pressure waveform which is Blue and brown colour line. After MAP 80% magnitude time, we took noninvasive waveform, selected 5 waveform for the calculation of decay constant and 75 points from each signals of 15 patients

28 Journal of Biomedical Engineering and Technology Table 4. The correlation coefficient is for noninvasive vs invasive arterial compliance of blood pressure waveforms. Waveform\R 2 NTG before NTG after Aortic vs Brachial 0.8351 0.7586 Aortic vs non invasive 0.1235 0.0337 Brachial vs noninvasive 0.1076 0.0961 4. Discussion Arterial compliance is the primary determining factor of aortic input impedance. It has been shown that increase in oxygen consumption, leads to the development of left ventricular hypertrophy and increasing ventricular after load. It directly affects the amplitude of the incident pressure wave and the timing of wave reflections [20,21]. Previous studies suggest that assessing of the arterial compliance using invasive way was more precise [25]. Most of the methods have been used to estimate compliance, but to date there are no longitudinal studies that relate abnormal compliance [24]. According to clinical data, arterial compliance was estimated by in-vitro methods using excised arteries. In-vivo (invasive) methods of determining compliance frequently use pulse contour analysis and require catheterization [22]. The other invasive technique for estimating compliance was intravascular ultrasound. With this technique, pressure and area are considered simultaneously. Pulse wave velocity (PWV) uses the concept that hard arteries and produce faster pulse wave transmission. While transcutaneous ultrasound techniques are limited by the ability of the ultrasound method to accurately image the anterior and posterior arterial wall. Each technique has own limitations; but in this study we performed analysis with physiological real data and find a better correlation to the non-invasive and invasive blood pressure wave form [23,24,25]. The arterial compliance was estimated by using the invasive brachial arterial blood pressure waveform and non-invasive pressure pulse waveform which is helpful to estimate the invasive aorta and invasive upper arm artery blood pressure waveform arterial compliance. It can be seen that the arterial compliance estimated by the invasive brachial arterial blood pressure waveform is very close to the total arterial compliance estimated by using the invasive aortic blood pressure waveform [25,26]. In this experiment, we selected the end of the diastolic waveform which is invasive aorta, brachial artery blood pressure waveform. There are two waveforms in the diastolic performance which are almost parallel, indicating that the two end of the diastolic waveform were similar. We found a high correlation of arterial compliance [Table 4] [Figure 5]. The arterial compliance estimated by using non-invasive pulsator waveforms is lower than the values estimated by the other two waveforms because the non-invasive pulsator waveform is captured using a cuff that contains a buffer of the performance such as compliance [Figure 5] [25]. And there are other tissues between the arteries and the cuff, so the non-invasive blood pressure waveform in the diastolic performance should include the superior arm artery arterial compliance, muscle and adipose tissue buffer, and the airbag itself compliance [25]. In contrast to the performance of the NTG drug, the effects of the drug itself on the blood vessels, as shown. We used the exponential decay constant of the blood pressure waveform in the exponential linear function. Non-invasive compressive pulse waveforms can be used to assess the total compliance of the arterial blood pressure waveforms of the invasive aorta to indicate noninvasive vasculature waveforms, contain the buffering of muscle and adipose tissue [25,26]. An arterial algorithm can be used directly on the electronic sphygmomanometer, so that subjects can measure arterial compliance immediately, and doctors can get the patient's daily condition so it has a great potential in homecare or domestic applications. Acknowledgments We are thankful to Department of Biomedical engineering, Chung Yuan Christian University, Taiwan and special thanks to Yuan-Ta Shih, Hao-Min Cheng and Chen-Huan Chen (Department of Medical Research and Education, Taipei Veterans General Hospital, No. 201, Sec. 2, Shih- Pai Rd, Taipei, Taiwan.) for providing the Medical data to perform the study. References [1] Beaglehole R., Yach D. Globalization and the Prevention and Control of Non-Communicable Disease: The Neglected Chronic Diseases of Adults. Lancet. 2003; 362: 903-8. [2] Mbewu, A. D. "Can Developing Country Systems Cope with the Epidemics of Cardiovascular Disease?" Paper presented at the Heart Health Conference, New Delhi, India, 1998. [3] Murray, C. J., and A. Lopez. The Global Burden of Disease. Washington, DC: World Bank, 1996. [4] Reddy K. S., Yusuf S. Emerging Epidemic of Cardiovascular Disease in Developing Countries. Circulation. 1998; 97: 596-601 [5] Mesquita, E. T., & Jorge, A. J. L. Understanding asymptomatic diastolic dysfunction in clinical practice. Arquivos brasileiros de cardiologia, 2013, 100(1), 94-101. [6] Seeman, T. E., McEwen, B. S., Rowe, J. W., & Singer, B. H. Allostatic load as a marker of cumulative biological risk: MacArthur studies of successful aging. Proceedings of the National Academy of Sciences, 2001, 98(8), 4770-4775. [7] Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L.,... & Benetos, A. Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients. Hypertension, 2001, 37(5), 1236-1241. [8] Romagnoli, S., Ricci, Z., Quattrone, D et al. Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study. Critical Care, 2014, 18(6), 644. [9] O rourke, M. F. Vascular impedance: the relationship between pressure and flow. Arterial function in health and disease, 1982, 94-132. [10] OROURKE, M., Avolio, A. P., Lauren, P. D., & Yong, J. AGE- RELATED-CHANGES OF ELASTIN LAMELLAE IN THE HUMAN THORACIC AORTA. In Journal of the American College of Cardiology (Vol. 9, No. 2, pp. A53-A53). 1987, 655. [11] Westerhof, N., Lankhaar, J. W., & Westerhof, B. E.The arterial windkessel. Medical & biological engineering & computing, 2009, 47(2), 131-141. [12] Manning, T. S., Shykoff, B. E., & Izzo, J. L.Validity and reliability of diastolic pulse contour analysis (windkessel model) in humans. Hypertension, 2002, 39(5), 963-968. [13] Tanaka, S., & Yamakoshi, K. Ambulatory instrument for monitoring indirect beat-to-beat blood pressure in superficial temporal artery using volume-compensation method. Medical and Biological Engineering and Computing, 1996, 34(6), 441-447.

Journal of Biomedical Engineering and Technology 29 [14] Schock, R. B., Williams, J., & Walters, D. A. U.S. Patent No. 7,229,403. Washington, DC: U.S. Patent and Trademark Office, 2007. [15] Wilkinson, I. B., Fuchs, S. A., Jansen, I. M., Spratt, J. C., Murray, G. D., Cockcroft, J. R., & Webb, D. J. Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis. Journal of hypertension, 1998, 16(12), 2079-2084. [16] Zimmerman, D. W. Teacher s corner: A note on interpretation of the paired-samples t test. Journal of Educational and Behavioral Statistics, 1997, 22(3), 349-360. [17] Benjamini, Y. Opening the Box of a Boxplot. The American Statistician, 1988, 42(4), 257-262. [18] Brinton, T. J., Cotter, B., Kailasam, M. T., Brown, D. L., Chio, S. S., O Connor, D. T., & DeMaria, A. N. Development and validation of a noninvasive method to determine arterial pressure and vascular compliance. The American journal of cardiology, 1997, 80(3), 323-330. [19] Cohen, M. V., Downey, J. M., Sonnenblick, E. H., & Kirk, E. S. The effects of nitroglycerin on coronary collaterals and myocardial contractility. Journal of Clinical Investigation, 1973, 52(11), 2836. [20] Kannel, W. B., & Stokes, J. I. I. I. Hypertension as a cardiovascular risk factor. Handbook of hypertension, 1985, 6, 15-34. [21] Kannel, W. B., Gordon, T., & Schwartz, M. J. Systolic versus diastolic blood pressure and risk of coronary heart disease: the Framingham study. The American journal of cardiology, 27(4), 1971, 335-346. [22] Knaevelsrud, T., & Framstad, T. Measurement of arterial blood pressure in the sow. A comparison between an invasive and an automatic oscillometric method. Veterinary Anaesthesia and Analgesia, 1992, 19(1), 10-12. [23] Bodey, A. R., Young, L. E., Bartram, D. H., Diamond, M. J., & Michell, A. R. A comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in anaesthetised dogs, using tail and limb cuffs. Research in veterinary science, 1994, 57(3), 265-269. [24] Borow, K. M., & Newburger, J. W. Noninvasive estimation of central aortic pressure using the oscillometric method for analyzing systemic artery pulsatile blood flow: comparative study of indirect systolic, diastolic, and mean brachial artery pressure with simultaneous direct ascending aortic pressure measurements. American heart journal, 1982, 103(5), 879-886. [25] Liu, B., Qiu, P., Chen, H., & Li, Q. Comparison of simultaneous invasive and non-invasive measurements of blood pressure based upon MIMIC II database. Artery Research, 2014, 8(4), 209-213. [26] Cheng, H. M., Lang, D., Pearson, A., & Worthley, S. G. Measurement Accuracy of Non-invasively Obtained Central Blood Pressure: A Systematic Review and Meta-analysis. JBI Database of Systematic Reviews and Implementation Reports, 2011, 9(52), 2166-2214.